Search NASA⌕ Search

SEARCH · Search NASA

Results for “balloons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of the EarthSHAB Stratospheric Solar Hot Air Balloon Flight Prediction Model Using Balloon Trajectory Data

Abstract The heliotrope is a solar balloon design which is constructed out of painter’s plastic, and the exterior is coated in charcoal powder. Darkening the plastic gives the balloon a high solar absorptance, which allows it to ascend into the lower stratosphere and float for hours at a time. The balloons have previously been used to lift scientific instruments into the stratosphere to study chemical explosions, earthquakes, and stratospheric aerosols. They have also been proposed as a platform for planetary exploration. Flight predictions are crucial to preflight planning to reduce safety risks and meet flight objectives. However, there exists a wide range of possible flight paths due to varying environmental conditions and solar balloon configurations. EarthSHAB is one such software that was designed to support flight planning using the weather forecasts and balloon properties to predict the flight path of a solar balloon. We compare EarthSHAB-simulated flight paths to a set of observed flight paths for the 3.5-m diameter heliotrope design called the “Cloudskimmer.” Using the criteria that the modeled paths must fall within 5% of the observations to be considered successful, we found that EarthSHAB successfully predicted the Cloudskimmer ascent rate and average float altitude 10% and 90% of the time, respectively. We also found that the average difference in the observed and predicted landing locations was 97 km and landing times were 54 ± 38 min. Significant deviations between the observed and predicted ascent rates and excursions at float were found to be associated with heavy payloads and convective cloud development, respectively. Significance Statement Solar balloons are used to lift scientific instruments into the lower stratosphere for hours at a time to study chemical explosions, earthquakes, stratospheric aerosols, and more. The flight paths of solar balloons can be difficult to predict due to variability in their design and surrounding environment. We evaluate the accuracy of EarthSHAB, a software that predicts the altitude profile and horizontal trajectory of a solar balloon using inputs such as the weather, balloon size, and balloon mass. Our results suggest that for the balloon design used in this study, EarthSHAB is best suited for modeling the behavior of balloons with lightweight payloads that do not fly within or directly above clouds.

Lien, Jessica M. [Sandia National Laboratories, Al↗

Balloon-Assisted Chemoembolization Using a Micro-Balloon Catheter Alongside a Microcatheter for a Hepatocellular Carcinoma with a Prominent Arterioportal Shunt: A Case Report

Although transcatheter arterial chemoembolization is one of the established treatments for hepatocellular carcinoma (HCC), it is difficult to treat HCCs with prominent arterioportal (AP) shunts because anticancer drugs and embolic materials migrate into the non-tumorous liver through the AP shunts and may cause liver infarction. We developed a novel method of balloon-assisted chemoembolization using a micro-balloon catheter alongside a microcatheter simultaneously inserted through a single 4.5-Fr guiding sheath, comprising proximal chemoembolization with distal arterial balloon occlusion. We applied this method to treat an HCC with a prominent distal AP shunt induced by previous proton beam therapy and achieved successful chemoembolization without non-tumorous liver infarction under temporal balloon occlusion of a distal AP shunt.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Randomized Freeway Stent Study: Drug-Eluting Balloons Outperform Standard Balloon Angioplasty for Postdilatation of Nitinol Stents in the SFA and PI Segment

Purpose: The prospective randomized multicenter Freeway study evaluated the possible hemodynamic and clinical benefits of primary stent insertion followed by percutaneous transluminal angioplasty (PTA) with drug-eluting balloons (DEB) over post-stent insertion PTA with standard balloons in the treatment of symptomatic femoropopliteal arteriosclerotic lesions. Methods: In total, 204 patients in 13 centers in Germany and Austria were enrolled and randomized to primary stenting followed by either FREEWAY™ drug-eluting balloon or standard PTA balloon angioplasty. The primary endpoint was the rate of clinically driven target lesion revascularization (TLR) at 6 months; the secondary endpoints include TLR rate at 12 months and primary patency, shift in Rutherford classification, ankle–brachial index (ABI) and major adverse events (MAE) at 6 and 12 months. Lesion characteristics and vessel patency were analyzed by an independent and blinded corelab. Results: At 6-month and 12-month follow-up, TLR rate was lower in the DEB arm compared to standard PTA but did not reach statistical significance (4.1% vs. 9.0% p = 0.234 and 7.9% vs. 17.7% p = 0.064, respectively). Primary patency was significantly better for patients treated with the DEB at 6 months (90.3% vs. 69.8% p = 0.001) and 12 months (77.4% vs. 61.0% p = 0.027). Improvement in Rutherford classifications was likewise significantly better for patients in the DEB group at 6 (94.9% vs. 84.3% p = 0.027) and 12 months (95.5% vs. 79.9% p = 0.003). The percentage of patients with an improved ABI of 1.0–1.2 was significantly higher in the DEB group compared to the PTA group at 6 months (55.3% vs. 35.3%; p = 0.015) but without significant difference at 12 months (48.2% vs. 32.9%; p = 0.055). At 6 months, rate of major adverse events (MAE) was 1% in both arms, and at 12 months 2.2% for the DEB and 3.8% for the PTA group. Conclusion: The Freeway Stent Study shows that the usage of DEB as a restenosis prophylaxis seems to be safe and feasible. The 12-month follow-up results give a clear sign in favor of the DEB group.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Efficacy of Paclitaxel Drug-Eluting Balloon Angioplasty Versus Standard Balloon Angioplasty in Stenosis of Native Hemodialysis Arteriovenous Fistulas: An Analysis of Clinical Success, Primary Patency and Risk Factors for Recurrent Dysfunction

Purpose: To investigate the efficacy of paclitaxel drug-eluting balloons (PEB) versus standard balloon angioplasty (BA) in stenosis of native hemodialysis arteriovenous fistulas (AVFs). Materials and Methods: A total of 96 patients with ESRD (mean ± SD age 57.0 ± 9.1 years, 63.5% were males) who underwent endovascular treatment with PEB angioplasty (n = 32) and BA (n = 64) for a dysfunctional native AVF were included. Clinical success, complications, primary patency and postoperative recurrence parameters were recorded in each group. Results: Primary patency rate at 6 months was significantly higher in PEB than in BA group (96.9 vs. 20.3%, p < 0.001), while the two groups had similar primary patency rates at 9 months (66.8 vs. 50.0%) and 12 months (6.3% for each). No significant difference was noted between PEB and BA groups in terms of the rate (21.9% and. 31.3%), time (median 220 vs. 152.5 days) and reasons (reocclusion in 18.8 vs. 28.1%) for dysfunction recurrence as well as the number of recurrent treatments. AVF dysfunction recurrence was more likely in younger age AVF (median 4 vs. 23 months, p < 0.001 in PEB, and 8.5 vs. 20.5 months p = 0.001 in SBA) and in AVF ≤ 6 months in both SBA and PEB groups (71.4 vs. 12.0%, p = 0.005 in PEB, 40.0 vs. 2.3%, p < 0.001). Conclusion: In conclusion, our findings emphasize favorable safety and efficacy of PEB and BA in the management of dysfunctional hemodialysis AVFs with similar rates of post-PTA recurrence of AVF dysfunction. Nonetheless, there was a nonsignificant tendency for lower rate and a delay for recurrent dysfunction in patients treated with PEB and a significant association younger AVF age with an increased risk of post-PTA recurrence of AVF dysfunction. Level of Evidence: 3, Retrospective cohort study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two-Year Mortality After Angioplasty of the Femoro-Popliteal Artery with Uncoated Balloons and Paclitaxel-Coated Balloons—A Pooled Analysis of Four Randomized Controlled Multicenter Trials

Purpose: In view of a recent meta-analysis reporting increased mortality following angioplasty with paclitaxel-coated devices in peripheral arteries, we performed a patient-level 2-year mortality analysis based on pooled original data of four randomized controlled trials (THUNDER, FEMPAC, PACIFIER and CONSEQUENT). Methods and Results: Clinical data of four randomized controlled trial were pooled to assess 2-year mortality following paclitaxel-coated balloon (PCB) angioplasty compared to angioplasty without paclitaxel (control group). A logistic regression model was applied to identify potential predictors of mortality. At two years, 13 of 185 (7.0%) patients had died in the control group and 16/184 (8.7%) in the PBC group, p = 0.55. Kaplan–Meier analysis revealed no significant difference from all-cause death at 2 years (log rank p = 0.54). Causes of death were well balanced between the groups with no pattern or trend in favour of any specific causes in the PBC group. Logistic regression revealed that treatment groups (controls or PBC) were not a predictor of 2-year mortality. The only predictor for mortality was patient age ≥ 75 years. The delivered paclitaxel doses per patient were not significantly different in patients that died and those who did not die during the 24-month follow-up (5.300 ± 4.224 μg vs. 6.248 ± 4.629 μg, p = 0.433). Conclusions: Based on original patient-level data of four pooled randomized controlled trials, we found no increase in 2-year mortality in patients treated with PCB compared to control patients treated with uncoated balloons. Causes of death were well balanced between PCB and control patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Change in Imaging Findings on Angiography-Assisted CT During Balloon-Occluded Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma

PurposeTo evaluate changes in imaging findings on CT during hepatic arteriography (CTHA) and CT during arterial portography (CTAP) by balloon occlusion of the treated artery and their relationship with iodized oil accumulation in the tumor during balloon-occluded transcatheter arterial chemoembolization (B-TACE).MethodsBoth B-TACE and angiography-assisted CT were performed for 27 hepatocellular carcinomas. Tumor enhancement on selective CTHA with/without balloon occlusion and iodized oil accumulation after B-TACE were evaluated. Tumorous portal perfusion defect size on CTAP was compared with/without balloon occlusion. Factors influencing discrepancies between selective CTHA with/without balloon occlusion and the degree of iodized oil accumulation were investigated.ResultsAmong 27 tumors, tumor enhancement on selective CTHA changed after balloon occlusion in 14 (decreased, 11; increased, 3). In 18 tumors, there was a discrepancy between tumor enhancement on selective CTHA with balloon occlusion and the degree of accumulated iodized oil, which was higher than the tumor enhancement grade in all 18. The tumorous portal perfusion defect on CTAP significantly decreased after balloon occlusion in 18 of 20 tumors (mean decrease from 21.9 to 19.1 mm in diameter; p = 0.0001). No significant factors influenced discrepancies between selective CTHA with/without balloon occlusion. Central area tumor location, poor tumor enhancement on selective CTHA with balloon occlusion, and no decrease in the tumorous portal perfusion defect area on CTAP after balloon occlusion significantly influenced poor iodized oil accumulation in the tumor.ConclusionsTumor enhancement on selective CTHA frequently changed after balloon occlusion, which did not correspond to accumulated iodized oil in most cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solar Hot Air Balloons for Terrestrial and Planetary Atmospheres

The first solar hot air balloon was constructed in the early 1970s (Besset, 2016). Over the following decades the Centre National d'Etudes Spatiales (CNES) developed the Montgolfiere Infrarouge (MIR) balloon, which flew on solar power during the day and infrared radiation from the Earth's surface at night (Fommerau and Rougeron, 2011). The balloons were capable of flying for over 60 days and apparently reached altitudes of 30 km at least once (Malaterre, 1993). Solar balloons were the subject of a Jet Propulsion Laboratory study that performed test flights on Earth (Jones and Wu 1999) and discussed their mission potential for Mars, Jupiter, and Venus (Jones and Heun, 1997). The solar balloons were deployed from the ground and dropped from hot air balloons; some were altitude controlled by means of a remotely-commanded air valve at the top of the envelope. More recently, solar balloons have been employed for infrasound studies in the lower stratosphere (see Table 1). The program began in 2015, when a prototype balloon reached an altitude of 22 kilometers before terminating just prior to float (Bowman et al., 2015). An infrasound sensor was successfully deployed on a solar balloon during the 2016 SISE/USIE experiment, in which an acoustic signal from a ground explosion was captured at a range of 330 km (Anderson et al. 2018; Young et al. 2018). This led to the launch of a 5-balloon infrasound network during the Heliotrope experiment (Bowman and Albert, 2018). The balloons were constructed by the researchers themselves at a materials of less than $50 per envelope.

14 SOLAR ENERGY↗

Chemosaturation Percutaneous Hepatic Perfusion (CS-PHP) with Melphalan: Evaluation of 2D-Perfusion Angiography (2D-PA) for Leakage Detection of the Venous Double-Balloon Catheter

Purpose: To evaluate the feasibility of 2D-perfusion angiography (2D-PA) for detecting leakage of the double-balloon catheter used for chemosaturation percutaneous hepatic perfusion (CS-PHP). Materials and Methods: Overall, 112 CS-PHP (09/2015-09/2018) in 52 patients were retrospectively screened for leakage alongside the double-balloon catheter on standard venograms. Finally, 18 procedures with visually detected leakage were included. Fifteen consecutive procedures without leakage served as control. To evaluate 2D-PA for leakage detection, the acquired digital subtraction venograms were post-processed. For each balloon, two different target ROIs were evaluated to assess a possible impact of localization and shape of the ROIs. Time to peak (TTP), peak density (PD), area under the curve (AUC), and ratios of target ROI/reference ROIs (PD{sub tROI}/PD{sub REF}; AUC{sub tROI}/AUC{sub REF}; and TTP{sub tROI}/TTP{sub REF}) were calculated. Results: Leakages were located as follows: 15/18 cranial and 3/18 caudal. At the cranial balloon both ROIs showed a significant decrease in PD{sub tROI}/PD{sub REF} and AUC{sub tROI}/AUC{sub REF} (ROI1: p < 0.0001; p < 0.0001; ROI2: p < 0.0001; p < 0.0001) and a significant increase in TTP{sub tROI}/TTP{sub REF} (ROI1: p = 0.0009; ROI2: p = 0.0003) after double-balloon correction. Following balloon adjustment, the 2D-PA ratios (PD and AUC) of the tested ROIs differed significantly (p < 0.05). The inter-individual comparison of the 2D-PA parameters of the group with leakage before balloon correction and the non-leakage group showed significantly different 2D-PA values for the cranial balloon in both ROIs (p < 0.05). No significant differences were found for the caudal balloon. Conclusion: 2D-PA provides a feasible tool for detecting leakages alongside the cranial portion of the double-balloon catheter used in CS-PHP. The shape and position of the ROIs used to assess perfusion and flow have an impact on the measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Balloon Tag Manufacturing Technique for Sensor Fish and Live Fish Recovery

Fish may experience injuries and mortality when they pass through hydraulic conveyances at hydropower dams, even if these conveyances are designed to be fish-friendly, such as downstream bypass systems, modified spillways and turbines. The main methods used to study fish passage conditions in hydraulic structures involve direct, in situ testing using Sensor Fish technology and live fish. Sensor Fish data helps identify physical stressors and their locations in the fish passage environment, while live fish are assessed for injuries and mortality. Balloon tags, which are self-inflating balloons attached externally to Sensor Fish and live fish, aid in their recovery after passing through hydraulic structures. This article focuses on the development of balloon tags with varying numbers of dissolvable, vegetable-based capsules containing a mixture of oxalic acid, sodium bicarbonate powders, and water at two different temperatures. Our research determined that balloon tags with three capsules, injected with 5 mL of water at 18.3 °C, consistently achieved the desired balloon volume. These tags had a mean inflation volume of 114 cm 3 with a standard deviation of 1.2 cm 3 . Among the balloon tags injected with water at 18.3 °C, it was observed that the two-capsule balloon tags took the longest time to reach full inflation. In addition, the four-capsule balloon tags demonstrated a faster inflation start time, while the three-capsule balloon tags demonstrated a faster deflation start time. Overall, this approach proves to be effective for validating the performance of new technologies, improving turbine design, and making operational decisions to enhance fish passage conditions. Importantly, it serves as a valuable tool for research and field evaluations, aiding in the refinement of both the design and operation of hydraulic structures.

59 BASIC BIOLOGICAL SCIENCES↗

The Relationship Between Neutrophil–Lymphocyte Ratio and Primary Patency of Percutaneous Transluminal Angioplasty in Hemodialysis Arteriovenous Fistula Stenosis When Using Conventional and Drug-Eluting Balloons

ObjectiveThe aim of this study is to investigate the potential association of neutrophil–lymphocyte ratio (NLR) between primary patency of percutaneous transluminal angioplasty (PTA) in hemodialysis arteriovenous fistula stenosis and type (Conventional and Drug-Eluting) of balloons used in PTA.Material-MethodThis retrospective study consists of 78 patients with significant arteriovenous fistulas stenosis who were treated with PTA by using Drug-Eluting Balloon (DEB) (n = 29) or Conventional Balloon (CB) (n = 49). NLR was calculated from preinterventional blood samples. All patients were classified into two groups. Group A; primary patency <12 months (43/78), Group B; primary patency ≥12 months (35/78). Cox regression analysis and Kaplan–Meier method were used to determine respectively independent factors affecting the primary patency and to compare the primary patency for the two balloon types.ResultsNLR ratio and balloon type of the two groups were significantly different (p = 0.002, p = 0.010). The cut-off value of NLR was 3.18 for determination of primary patency, with sensitivity of 81.4 % and specificity of 51.4 %. Primary patency rates between PTA with DEB and CB displayed statistically significant differences (p < 0.05). The cut-off value was 3.28 for determination of 12-month primary patency with the conventional balloon group; sensitivity was 81.8 % and specificity was 81.3 %. There was no statistical relation between NLR levels and the drug-eluting balloon group in 12-month primary patency (p = 0.927).ConclusionIncreased level of NLR may be a risk factor in the development of early AVF restenosis after successful PTA. Preferring Drug-Eluting Balloon at an increased level of NLR can be beneficial to prolong patency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Contrast Agent Dilution on Ballon Deflation Time and Visibility During Tracheal Balloon Dilation: A 3D Printed Phantom Study

PurposeTo determine the effect of contrast medium dilution during tracheal balloon dilation on balloon deflation time and visibility using a 3-dimensional (3D) printed airway phantom.Materials and MethodsA comparison study to investigate balloon deflation times and image quality was performed using two contrast agents with different viscosities, i.e., iohexol and ioxithalamate, and six contrast dilutions with a 3D printed airway phantom.ResultsCompared to 1:0 concentration, 3:1, 2:1, 1:1, 1:2, and 1:3, contrast/saline ratios resulted in a 46% (56.2 s), 59.8% (73.1 s), 74.9% (91.6 s), 81.7% (99.8 s), and 83.5% (102 s) reduction for iohexol, respectively, and a 51.8% (54.7 s), 63.8% (67.6 s), 74.7% (79.2 s), 80.5% (85.3 s), and 82.4% (87.4 s) reduction for ioxithalamate, respectively, in the mean balloon deflation time, although at the expense of decreased balloon opacity (3.5, 6.9, 11.1, 12.4, and 13.9%, for iohexol, respectively, and 3.2, 6, 9.6, 10.8, and 12.4%, for ioxithalamate, respectively).ConclusionsUse of a lower viscosity contrast agent and higher contrast dilution is considered to be able to reduce balloon deflation times and then simultaneously decrease visualization of balloons. The rapid balloon deflation time is likely to improve the safe performance of interventional procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Studying the effect of drug-to-excipient ratio on drug release profile for drug coated balloons

Drug-coated balloons (DCB) have emerged as the alternative procedure for restenosis because of their ability to treat a variety of occlusion types with a uniform dose of anti-proliferative drugs. DCB are balloons coated with antiproliferative drugs encapsulated in a polymer matrix. There are several types of coating matrices used to produce DCB. In this study, the relationship between coating composition and drug release under physiologically relevant conditions was examined to understand how differences in coating composition impacts the drug transfer from the balloon surface to the simulated body fluids. To conduct the experiments, the balloons were coated with different paclitaxel (drug)-to-iopromide (excipient) ratios (3:1, 3:2 and 1:2) using an in-house developed micro-pipetting method. Scanning electron microscopy (SEM) images showed that the 3:1 PTX:IOP ratio produced a more uniform, crystalline microstructure with a thinner coating throughout the balloon surface compared to the other drug-to-excipient ratios. The 1:2 PTX:IOP ratio showed the least crystalline microstructure among the three ratios evaluated in this study. Three different drug elution conditions were tested. The amount of drug released to the medium was quantified by high performance liquid chromatography (HPLC). Our soaking study and submerge & deploy study showed that ~20% of the drug transferred to the target site under physiological conditions. A track and deploy method was performed using a “mock” artery, to simulate an in vitro environment. Coated balloons were passed through the mock artery to mimic tracking turns the balloon within the arteries during the angioplasty procedures. Seven elution samples were collected at different stages of the procedure. Finally, drug release results suggest that the higher excipient ratio helps to deliver the lipophilic drug to the target site under simulated conditions but causes higher drug loss during the balloon transfer process.

60 APPLIED LIFE SCIENCES↗

Joint UAS-Balloon Activities (JUBA) Field Campaign Report

Using internal investment funds within Sandia National Laboratories’ (SNL) Division 6000, the Joint UAS-Balloon Activity (JUBA) was a collaborative exercise between SNL Organizations 6533 and 6913 (later 8863) to demonstrate simultaneous flights of tethered balloons and unmanned aerial systems (UAS) on the North Slope of Alaska. JUBA UAS and tethered balloon flights were conducted within the Restricted Airspace associated with the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Climate Research Facility third ARM Mobile Facility (AMF3) site at Oliktok Point, Alaska. The Restricted Airspace occupies a two-nautical-mile radius around Oliktok Point. JUBA was conducted at the Sandia Arctic Site, which is approximately 2 km east-southeast of the AMF3. JUBA activities occurred from 08/08/17 and 08/10/17. Atmospheric measurements from tethered balloons can occur for a long duration, but offer limited spatial variation. Measurements from UAS could offer increased spatial variability. To understand how balloon and UAS activities could occur together, JUBA activities included the following: Developing aviation safety plans for the simultaneous, collocated operation of tethered balloons and UAS Adapting tethered balloon-based fiber optic distributed temperature sensing (DTS) measurements to a UAS platform Creating solutions to technical challenges such as: Developing a motor system to match the fiber deployment rate with the ascent/descent rate of the UAS Evaluating methods of identifying the surface in the DTS temperature profile Correlating simultaneous balloon and UAS DTS temperature measurements Assessing the effects of a fiber optic rotary joint on the DTS temperature measurements Determining what UAS-based sensors provided the best calibration source for the DTS temperature data.

North Slope of Alaska, arctic processes, unmanned ↗

Report on ISR-1 High-Altitude Balloon Flight

To test small technologies at lower cost for space science applications, LANL has developed a small high altitude balloon payload that could, in the future, be regularly and inexpensively launched from LANL. A neutron detector, NEMO, was integrated to evaluate its performance in a space-like mixed-radiation environment and collect neutron data in the atmosphere. In collaboration with EES-14, a high-altitude balloon payload was launched from LANL Technical Area 51 on February 27, 2023 and April 17, 2023. For real-time geolocation, a SAM-M8Q M8 GNSS module was used to get position and time, and an Iridium RockBLOCK 9603 was used to communicate with the ground using the Iridium satellite fleet. These modules were all controlled using an Iteaduino Mega microcontroller board. Finally, a High Altitude Science Eagle Flight Computer with a temperature pressure sensor ran independently, writing data to an SD card. All of these modules were powered by a 5 mAh lithium polymer battery. The battery was attached to the bottom of the payload while the remaining electronics were embedded in the underside of the top of the payload. These modules were wired as seen in Figure 1-2. The Iteaduino Mega microcontroller board was programmed to use the RockBLOCK to send a message once every 10 minutes containing neutron and GPS data read off the NEMO and SAM M8Q, respectively. Once the message send attempt finished, the RockBLOCK would be slept for the rest of the 10 minute interval. The Eagle Flight Computer ran continuously throughout the flight, taking data every 6 seconds. The RockBLOCK message data was set up to be delivered from the Iridium satellite fleet to a website, where it was stored and parsed to create live maps and plots for analysis and balloon retrieval. The RockBLOCK message data was additionally configured to be sent to an email as a fail-safe. The payload was ground-tested successfully for over 50 hours, with multiple revisions occurring to best prepare for conditions at altitude and improve the software and firmware to fix any issues that cropped up with the data pipeline. Additional to the balloon payload, the flight had an attached iMet-4 radiosonde and Garmin T5 GPS Dog Collar. The radiosonde provided GPS and meteorological data. The T5 dog collar is used along with a Garmin Astro 430 to track the balloon at a range of up to 9 miles for retrieval. The balloon itself was initially a 1600 g meteorological balloon with an attached High Altitude Science parachute, both of which can be seen in Figure 1-3. After the first flight, the EES team swapped to a Rocketman parachute.

42 ENGINEERING↗

The impact of kinetic and global effects on ideal ballooning 2nd stable pedestals of conventional and low aspect-ratio tokamaks

The EPED model (Snyder et al 2011 Nucl. Fusion 51 103016) has had success in describing the pedestal structure of Type-I ELM and QH-mode plasmas in tokamaks, by combining kinetic ballooning mode (KBM) and peeling–ballooning (PB) constraints. Within EPED, the KBM constraint is often approximated by a technique using calculated ideal ballooning mode (IBM) thresholds, fit to a functional form designed to capture non-local effects. It has been noted that quantitative differences between local ideal MHD and gyro-kinetic (GK) ballooning stability can be larger at low aspect ratio. KBM critical pedestals are consistent with observations in initial studies on conventional and spherical tokamaks. In this work, the application of a reduced model for the calculation of the kinetic ballooning stability boundary is presented based on a novel and newly developed gyro-fluid system (GFS) code (Staebler et al 2023 Phys. Plasmas 30 102501). GFS is observed to capture KBMs in DIII-D as well as the NSTX pedestals, opening a route to integrating this model into EPED. Finally, high but finite $n$ global ballooning modes are observed to limit the access to the local 2nd stability and thus provide a transport mechanism that constrains the pedestal evolution with $β_{p,\textrm{ped}}$. The high $n$ global ballooning stability is approximated by its ideal MHD analog using ELITE. It is shown that nearly-local high $n$ modes with $k_yρ_s$ ~ $0.25 - 0.5$ can provide a proxy for the critical $β_{p,\textrm{ped}}$ when a 2nd stable access exists on DIII-D plasmas. The use of GFS and ELITE scaling in EPED provides improved agreement to EPED1 in an initial comparison with DIII-D pedestal data.

Anastopoulos Tzanis, Michail Savvas [Oak Ridge Nat↗

Modeling the Vertical Response of an Aeroseismometer Balloon System

Aeroseismometery is a novel, cutting edge capability that involves balloon based systems for detecting and geolocating sources of infrasound. The incident infrasound from a range of sources such as volcanos, earthquakes, explosions, supersonic aircraft impinges upon the balloon system causing it to respond dynamically. The dynamic response is post-processed to locate the infrasound source. This report documents the derivation of an analytical model that predicts the balloon dynamics. Governing equations for the system are derived as well as a transfer function relating the infrasound signal to the net force on the balloon components. Experimental measurements of the infrasound signals are convolved with the transfer function and the governing equations numerically time integrated to obtain predictions of the displacement, velocity and acceleration of the balloon system. The predictions are compared to the experimental measurements with good agreement observed. The derivation focuses only on the vertical dynamics of the balloon system. Future work will develop governing equations for the swinging response of the balloon to the incident infrasound.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗