Search NASA⌕ Search

SEARCH · Search NASA

Results for “battery EMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Application of Cyber-Informed Engineering for Protecting BESS

This white paper synthesizes an array of crucial grid services provided by BESS technology, assesses its architecture and communications, and presents a case study for analysis against the principles introduced by Cyber-Informed Engineering (CIE). Furthermore, in walking through the analysis, this paper presents a framework to evaluate risks and solutions when considering BESS components. Asset owners and buyers could perform this analysis to assess their BESS product implementations, alternative inverter-based resources (IBR), and energy management systems (EMS). Battery systems fulfill various roles contingent on the unique market demands and the specific challenges presented by regional grid infrastructures. These roles also vary due to the differing utility models for ownership and operation, which are adapted to meet regional and local capabilities and requirements. Concerns have been raised regarding the potential for adversaries to exploit knowledge of battery operational patterns to orchestrate decisive attacks. However, the security of operational data for these systems may not be the primary vulnerability, as much of this information is already well-understood within the community. Applying a modest degree of subject matter expertise can often yield valuable predictions regarding how a battery will respond under certain conditions, such as grid emergencies, high or low-temperature days, Public Safety Power Shutoff (PSPS) events, and outages. The operational characteristics of batteries are well-documented, and their capabilities, including the risks associated with misoperation and the resulting consequences, are published and understood within the industry. CIE practices represent the next step in gaining functional assurance and providing an acceptable level of risk, regardless of whether a battery vendor can support a trusted and validated supply chain. While this issue has exacerbated supply chain challenges, it is not an isolated condition. This foreign supply route is the primary source of BESS for the U.S. market. Significant efforts are underway through the Bipartisan Infrastructure Law (BIL) to change that. Still, strategic short-term operational mitigations are needed to ensure the security of our operational technology (OT) systems, which are enhanced by instilling trust and are separate from vendors implementing CIE principles.

25 ENERGY STORAGE↗

Trapping and imaging dynamic battery nanointerfaces via electrified cryo-EM

The electrified interface between a liquid and a solid underpins diverse phenomena, from ion-transfer during battery operation to action potentials enabling biological communication. However, conventional tools are blind to the nanoscale dynamics of this metastable interface. Here, we leverage electrified cryo–electron microscopy (eCryo-EM), a technique that rapidly freezes and kinetically traps these dynamic, nonequilibrium states during battery operation for nanoscale characterization. Collective snapshots of the electrified interface at controlled time intervals quantifies early-stage growth kinetics of the solid electrolyte interphase (SEI), a passivation film that governs electron and ion transport. Unexpectedly, the diffusivity of charged species of the two SEI films with differing chemistry and performance are estimated to be within 10% of the other, indicated by the slope of their diffusion-limited SEI growth regimes. Instead, the slope of the reaction-limited SEI growth regimes differs by a factor of 3, suggesting that lowered reactivity of the high-performance electrolyte is largely responsible for its high coulombic efficiency.

Science & Technology - Other Topics↗

Ion-Depleted Microenvironments During Lithium Deposition Revealed by Operando Freezing Cryogenic Electron Microscopy

Local structures and chemistry at active electrochemical interfaces are critical to determining safety, lifetime, and energy density in lithium metal batteries and other devices, but they are challenging to characterize at the nanoscale. We address this issue by developing operando freezing cryogenic electron microscopy (cryo-EM) to preserve battery interfaces in an active state for subsequent high-resolution characterization. We find that ion-depleted microenvironments form locally in the electrolyte adjacent to the lithium deposition interface in lithium metal batteries and are linked to heterogenous growth morphologies. These depleted environments arise locally even under conditions for which ion depletion is not predicted at steady state; this provides a mechanistic explanation for why dangerous lithium morphologies can still propagate in such systems and lead to thermal runaway. Operando freezing cryo-EM thus provides a method to directly visualize nanoscale heterogeneities that arise locally at electrochemical interfaces and play key roles in device failure.

CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS,E↗

Freeze It or Leave It? Evaluating the Role of Cryo-Electron Microscopy in Battery Research

Cryogenic electron microscopy (cryo-EM) continues to gain prominence in materials science, particularly in battery research where it has enabled high-resolution, multimodal characterization of electrode materials and interfaces that otherwise degrade quickly under electron beam irradiation. But as anyone who has attempted cryo-EM techniques knows, freezing comes at a cost; cryo-EM experiments are time-consuming, highly sensitive, and carry an increased risk of artifacts due to issues such as frost contamination. Thus, when planning new characterization of battery materials or other beam-sensitive samples, it is critical to consider whether (and which) cryo-EM techniques are appropriate, based on study goals and an understanding of electron beam-sample interactions. Here we review such considerations for battery materials to elucidate the questions of when, why, and how to freeze to achieve high-quality characterization.

25 ENERGY STORAGE↗

Cryogenic EM Across Length Scales for Li Metal Anode Batteries

An interfacial understanding is necessary for developing strategies to commercialize high-energy density rechargeable lithium metal anode batteries, as currently, the lithium anode/electrolyte interface is unstable with prolonged cycling. We have used several strategies to improve the cycling performance of lithium metal anodes, including reducing the parasitic reactions between lithium metal and the electrolyte, and improving the electrodeposited lithium metal morphology. These strategies have generated unconclusive electrochemical data, that has required the need for nanoscale interfacial characterization of these solid-liquid interfaces. Our team has used the cryogenic transfer workflow developed by Leica in collaboration with cryo-SEM/FIB tools by Thermo Fisher Scientific to cross-section lithium metal anodes and intact coin cell batteries to observe the interfacial structures, lithium morphology, and failure mechanisms relative to changes in electrode contract pressure and electrolyte chemistry. Cross-sectional SEM images and EDS maps of the lithium metal anodes have provided a better understanding of the electrodeposited lithium morphology, quantity of 'dead' lithium metal, and quantity of solid electrolyte interphase material that has formed alongside the lithium metal. In understanding lithium metal battery failure at the system level, we used a cryogenic stage in a laser plasma FIB to cross-section through the coin cell's cap for imaging/mapping the entire battery stack under cryogenic conditions. The tools, methods, and results of these studies will be detailed in this presentation.

characterization↗

Operando Freezing Cryogenic Electron Microscopy of Active Battery Materials

Abstract Understanding structural and chemical evolution of battery materials during operation is critical to achieving safe, efficient, and long-lasting energy storage. Cryogenic electron microscopy (cryo-EM) has become a valuable tool in battery characterization, leveraging low temperatures to improve stability of sensitive materials under electron beam irradiation. However, typical cryo-EM sample preparations leave extended time between the electrochemical point of interest and ex situ freezing of samples, during which active structures may relax, degrade, or otherwise evolve. Here, we detail a method for operando freezing cryo-EM to preserve and characterize native electrode and interfacial structures that arise during battery cycling, based on an operando plunge freezer and cold sample removal process. We validate the method on multiple electrode materials and quantify and discuss the freezing rate achieved. Operando freezing cryo-EM can be used to directly visualize transient features that arise at active electrochemical interfaces, to enable deeper understanding of structural evolution and interfacial chemistry in batteries and other electrochemical systems.

25 ENERGY STORAGE↗

Improving the Freight Productivity of a Heavy-Duty, Battery Electric Truck by Intelligent Energy Management

This project aimed to enhance the range and reduce the operating costs of battery electric Class 8 trucks traveling over 250 miles daily. This was achieved through the development and implementation of an intelligent-Energy Management System (i-EMS) that leverages vehicle and operations data, physics-aware machine learning algorithms, and vehicle-to-cloud (V2C) connectivity. The project hypothesized that advanced machine learning algorithms and real-time data analytics could significantly improve the energy efficiency and range of these trucks. Key objectives included developing a physics-aware machine learning algorithm, implementing an i-EMS with V2C connectivity and physics-aware spatial data analytics (PSDA), and validating the system’s effectiveness with fleet partners HEB Companies and Murphy Logistics. Extensive data collection from vehicle operations, including vehicle characteristics, road conditions, and payload, was conducted. A machine learning algorithm was developed to predict energy consumption and enable proactive decision-making. The i-EMS was implemented on two Volvo VNR BEVs, with operators receiving charging and routing recommendations. Charging stations were installed at depot locations in Texas and Minnesota, with an additional on-route charger in Minnesota. Significant findings included a 14% range improvement for Murphy Logistics on a highway-driving eco-route and a 22% range improvement for HEB Companies on a city-driving eco-route. The i-EMS utilized rule-based methods and physics-based algorithms to predict and reduce energy consumption, with real-time monitoring and analysis through V2C connectivity enabling proactive decision-making. The project demonstrated the feasibility and economic viability of battery electric Class 8 trucks for long-haul operations, showcasing the potential of physics-aware machine learning in optimizing energy management. The successful implementation of the i-EMS in real-world scenarios validates its practical application and effectiveness, paving the way for the widespread adoption of battery electric vehicles in the freight transportation industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrified Operando -Freezing of Electrocatalytic CO 2 Reduction Cells for Cryogenic Electron Microscopy

The ability to freeze and stabilize reaction intermediates in their metastable states and obtain their structural and chemical information with high spatial resolution would be very powerful to unravel the fundamentals in many important materials technologies such as catalysis and batteries. Here, we develop an electrified operando-freezing methodology for the first time to preserve these metastable states under electrochemical reaction conditions for cryogenic electron microscopy (cryo-EM) imaging and spectroscopy. Using Cu catalysts for CO 2 reduction as a model system, we observe restructuring of the Cu catalyst in a CO 2 atmosphere while the same catalyst remains intact in an air atmosphere at the nanometer scale. Furthermore, we discover the existence of single valance Cu (1+) state and C-O bonding at the electrified liquid-solid interface of the operando-frozen samples, which are key reaction intermediates that traditional ex situ measurements fail to detect. Finally, this work highlights our novel technique to study the local structure and chemistry of electrified liquid-solid interfaces, which has broad impact for many electrochemical reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resolving three-dimensional nanoscale heterogeneities in lithium metal batteries with cryoelectron tomography

Current direct observation of sensitive battery materials and interfaces primarily relies on two-dimensional (2D) imaging, leaving out their three-dimensional (3D) relationship. Here, in this study, we used cryoelectron tomography (cryo-ET) to visualize the lithium metal anode in 3D at nanometer resolution and cryoelectron microscopy (cryo-EM) to reveal atomic details in local regions. We imaged both freshly prepared and calendar-aged Li metal anodes to reveal the development of LiH in Li dendrites and the Li-LiH interface, as well as the development of the solid-electrolyte interphase (SEI). Using a convolutional neural network-based technique, the 3D arrangement of Li metal, along with nanoscale LiH and Cu heterogeneities in dendrites, was visualized and annotated. In longer-term calendar aging, we observed more substantial LiH growth accompanied by extended SEI growth. Our results show that the growth of LiH and the extended SEI during battery calendar aging are temporally and spatially separate processes.

LiH↗

Nonsolvating Fluoroaromatic Cosolvent Enabled Long-Term Cycling of High-Voltage Lithium-Ion Batteries with Organosulfur Electrolytes

Here, the structure–activity relationships of nonsolvating cosolvents for organosulfur-based electrolyte systems were revealed. The performance of nonsolvating dilutant fluorobenzene (FB) was compared to various fluorinated ether dilutants in high-voltage electrolytes containing a concentration of 1.2 M LiPF 6 dissolved in fluoroethylene carbonate (FEC), ethyl methyl sulfone (EMS), and the dilutant. In a high-voltage and high-loading LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) full cell configuration, the organosulfur-based electrolyte containing FB dilutant enabled superior electrochemical performance compared to the electrolytes using other nonsolvating fluorinated ether formulations. Moreover, the FB-containing electrolyte exhibited the highest ionic conductivity and lowest viscosity among all organosulfur-based electrolytes containing nonsolvating dilutant. These improvements are attributed to the enhanced physical properties of electrolyte and lithium-ion mobility. Furthermore, by employing first-principles simulations, the observed suppression of side reactions at high voltage is linked to FB’s lower reactivity toward singlet dioxygen, which is likely produced at the NMC interface. Overall, FB is considered an excellent diluent that does not impede cell operation by mass decomposition at the cathode.

25 ENERGY STORAGE↗

Solvent–Diluent Engineering of Normal-Concentration Organosulfur Electrolytes for High-Voltage Lithium-Ion Batteries

Enabling high‑voltage batteries depends critically on rational electrolyte design. Conventional carbonate electrolytes with LiPF 6 suffer from insufficient oxidative stability, motivating the use of lithium bis(fluorosulfonyl)imide (LiFSI) for its superior high‑temperature and high‑voltage performance. However, LiFSI is relatively costly, and its electrolytes often require high concentrations to suppress aluminum current collector corrosion in cathode architectures and to adequately passivate electrode interfaces. Here, a low‑concentration LiFSI electrolyte is realized by combining a high‑voltage organosulfur solvent, ethyl methyl sulfone (EMS), with a non‑solvating fluorinated diluent, fluorobenzene (FB). Extended cycling of LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) full cells to 4.5 V reveals substantial long‑term performance advantages over conventional carbonate electrolytes. Comparison with a popular cyclic sulfone, tetramethylene sulfone (TMS), shows that ring‑containing structures such as TMS strongly influence passivation behavior, ultimately limiting performance and narrowing the viable operating window. Overall, EMS is identified as a uniquely stable solvent for LiFSI‑based electrolytes operating at moderately high voltages.

Dato, Michael A. [Argonne National Laboratory (ANL↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗