Search NASA⌕ Search

SEARCH · Search NASA

Results for “battery electric equipment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Fastrack Suborbital Platform for Microgravity Applications

The FASTRACK suborbital experiment platform has been developed to provide a capability for utilizing 2.5-5 minute microgravity flight opportunities anticipated from the commercial suborbital fleet (currently in development) for science investigations, technology development and hardware testing. It also provides "express rack" functionality to deliver payloads to ISS. FASTRACK fits within a 24" x 24" x 36" (61 cm x 61 cm x 91.4 cm) envelope and is capable of supporting either two single Middeck Locker Equivalents (MLE) or one double MLE configuration. Its overall mass is 300 lbs (136 kg), of which 160 lbs (72 kg) is reserved for experiments. FASTRACK operates using 28 VDC power or batteries. A support drawer located at the bottom of the structure contains all ancillary electrical equipment (including batteries, a conditioned power system and a data collection system) as well as a front panel that contains all switches (including remote cut-off), breakers and warning LEDs.

Levine, H. G.↗

STS-106 Crew Activities Report/Flight Day 06 Highlights

On this sixth day of the STS-106 Atlantis mission, the flight crew, Commander Commander Terrence W. Wilcutt, Pilot Scott D. Altman, and Mission Specialists Daniel C. Burbank, Edward T. Lu, Richard A. Mastracchio, Yuri Ivanovich Malenchenko, and Boris V. Morukov are seen participating in several outfitting and transferring activities. Burbank and Morukov replace batteries in Zarya, while Lu and Malenchenko install three batteries and electrical equipment inside the Zvezda Service Module. Footage of Wilcutt participating in an interview concludes the events of the day.

Source record↗

Design description of the Schuchuli Village photovoltaic power system

A stand alone photovoltaic (PV) power system for the village of Schuchuli (Gunsight), Arizona, on the Papago Indian Reservation is a limited energy, all 120 V (d.c.) system to which loads cannot be arbitrarily added and consists of a 3.5 kW (peak) PV array, 2380 ampere-hours of battery storage, an electrical equipment building, a 120 V (d.c.) electrical distribution network, and equipment and automatic controls to provide control power for pumping water into an existing water system; operating 15 refrigerators, a clothes washing machine, a sewing machine, and lights for each of the homes and communal buildings. A solar hot water heater supplies hot water for the washing machine and communal laundry. Automatic control systems provide voltage control by limiting the number of PV strings supplying power during system operation and battery charging, and load management for operating high priority at the expense of low priority loads as the main battery becomes depleted.

Ratajczak, A. F.↗

STS-106 Crew Activities Report/Flight Day 07 Highlights

On this seventh day of the STS-106 Atlantis mission, the flight crew, Commander Commander Terrence W. Wilcutt, Pilot Scott D. Altman, and Mission Specialists Daniel C. Burbank, Edward T. Lu, Richard A. Mastracchio, Yuri Ivanovich Malenchenko, and Boris V. Morukov are seen participating in several outfitting activities. Burbank and Morukov remove and replace a fourth battery in Zarya. Lu and Malenchenko finish installing the third and final battery and other electrical equipment inside the Zvezda Service Module. While Altman and Wilcutt perform a series of jet firings, Altman is shown as he narrates a tour of the Zvezda Service Module. Scenes also include Lu and Malenchenko unpacking the Russian-made Orlan space suits, Burbank and Wilcutt participating in an interview, and a beautiful night shot of the International Space Station (ISS) and Atlantis complex above the Earth.

Source record↗

Design and fabrication of a photovoltaic power system for the Papago Indian village of Schuchuli (Gunsight), Arizona

A stand alone photovoltaic power system for installation in the Papago Indian village of Schuchuli is being designed and fabricated to provide electricity for village water pumping and basic domestic needs. The system will consist of a 3.5 kW (peak) photovoltaic array; controls, instrumentations, and storage batteries located in an electrical equipment building and a 120 volt dc village distribution network. The system will power a 2 HP dc electric motor.

Bifano, W. J.↗

Thermal control system for Space Station Freedom photovoltaic power module

The electric power for Space Station Freedom (SSF) is generated by the solar arrays of the photovoltaic power modules (PVM's) and conditioned, controlled, and distributed by a power management and distribution system. The PVM's are located outboard of the alpha gimbals of SSF. A single-phase thermal control system is being developed to provide thermal control of PVM electrical equipment and energy storage batteries. This system uses ammonia as the coolant and a direct-flow deployable radiator. This paper presents the description and development status of the PVM thermal control system.

Hacha, Thomas H.↗

Thermal control system for Space Station Freedom photovoltaic power module

The electric power for Space Station Freedom (SSF) is generated by the solar arrays of the photovoltaic power modules (PVM's) and conditioned, controlled, and distributed by a power management and distribution system. The PVM's are located outboard of the alpha gimbals of SSF. A single-phase thermal control system is being developed to provide thermal control of PVM electrical equipment and energy storage batteries. This system uses ammonia as the coolant and a direct-flow deployable radiator. The description and development status of the PVM thermal control system is presented.

Hacha, Thomas H.↗

Nickel-hydrogen battery integration study for the Multimission Modular Spacecraft

A study has been performed to determine the feasibility of using nickel-hydrogen batteries as replacements for the nickel-cadmium batteries currently used for energy storage in the Multimission Modular Spacecraft under a contract with NASA Goddard Space Flight Center. The battery configuration was selected such that it meets volumetric and mounting constraints of the existing battery location, interfaces electrically with existing power conditioning and distribution equipment, and maintains acceptable cell operating temperatures. The battery contains 21, 50 ampere-hour cells in a cast aluminum structural frame. Cells used in the battery design are those developed under the Air Force's Aero Propulsion Laboratory funding and direction. Modifications of the thermal control system were necessary to increase the average output power capability of the Modular Power Subsystem.

Mueller, V. C.↗

Battery Reinitialization of the Photovoltaic Module of the International Space Station

The photovoltaic (PV) module on the International Space Station (ISS) has been operating since November 2000 and supporting electric power demands of the ISS and its crew of three. The PV module contains photovoltaic arrays that convert solar energy to electrical power and an integrated equipment assembly (IEA) that houses electrical hardware and batteries for electric power regulation and storage. Each PV module contains two independent power channels for fault tolerance. Each power channel contains three batteries in parallel to meet its performance requirements and for fault tolerance. Each battery consists of 76 Ni-Hydrogen (Ni-H2) cells in series. These 76 cells are contained in two orbital replaceable units (ORU) that are connected in series. On-orbit data are monitored and trended to ensure that all hardware is operating normally. Review of on-orbit data showed that while five batteries are operating very well, one is showing signs of mismatched ORUs. The cell pressure in the two ORUs differs by an amount that exceeds the recommended range. The reason for this abnormal behavior may be that the two ORUs have different use history. An assessment was performed and it was determined that capacity of this battery would be limited by the lower pressure ORU. Steps are being taken to reduce this pressure differential before battery capacity drops to the point of affecting its ability to meet performance requirements. As a first step, a battery reinitialization procedure was developed to reduce this pressure differential. The procedure was successfully carried out on-orbit and the pressure differential was reduced to the recommended range. This paper describes the battery performance and the consequences of mismatched ORUs that make a battery. The paper also describes the reinitialization procedure, how it was performed on orbit, and battery performance after the reinitialization. On-orbit data monitoring and trending is an ongoing activity and it will continue as ISS assembly progresses.

Hajela, Gyan↗

Balloon platform for extended-life astronomy research

A configuration has been developed for a long-life balloon platform to carry pointing telescopes weighing as much as 80 pounds (36 kg) to point at selected celestial targets. A platform of this configuration weighs about 375 pounds (170 kg) gross and can be suspended from a high altitude super pressure balloon for a lifetime of several months. The balloon platform contains a solar array and storage batteries for electrical power, up and down link communications equipment, and navigational and attitude control systems for orienting the scientific instrument. A biaxial controller maintains the telescope attitude in response to look-angle data stored in an on-board computer memory which is updated periodically by ground command. Gimbal angles are computed by using location data derived by an on-board navigational receiver.

Ostwald, L. T.↗

Design and Development of a 200-kW Turbo-Electric Distributed Propulsion Testbed

The National Aeronautics and Space Administration (NASA) Armstrong Flight Research Center (AFRC) (Edwards, California) is developing a Hybrid-Electric Integrated Systems Testbed (HEIST) Testbed as part of the HEIST Project, to study power management and transition complexities, modular architectures, and flight control laws for turbo-electric distributed propulsion technologies using representative hardware and piloted simulations. Capabilities are being developed to assess the flight readiness of hybrid electric and distributed electric vehicle architectures. Additionally, NASA will leverage experience gained and assets developed from HEIST to assist in flight-test proposal development, flight-test vehicle design, and evaluation of hybrid electric and distributed electric concept vehicles for flight safety. The HEIST test equipment will include three trailers supporting a distributed electric propulsion wing, a battery system and turbogenerator, dynamometers, and supporting power and communication infrastructure, all connected to the AFRC Core simulation. Plans call for 18 high performance electric motors that will be powered by batteries and the turbogenerator, and commanded by a piloted simulation. Flight control algorithms will be developed on the turbo-electric distributed propulsion system.

distributed↗

Automation concepts for large space power systems

A study was undertaken to develop a methodology for analyzing, selecting, and implementing automation functions for multi-hundred-kW photovoltaic power systems intended for manned space station. The study involved identification of generic power system elements and their potential faults, definition of automation functions and their resulting benefits, and partitioning of automation functions between power subsystem, central spacecraft computer, and ground. Automation to a varying degree was concluded to be mandatory to meet the design and operational requirements of the space station. The key drivers are indefinite lifetime, modular growth, high performance flexibility, a need to accommodate different electrical user load equipment, on-orbit assembly/maintenance/servicing, and potentially large number of power subsystem components. Functions that are good candidates for automation via expert system approach includes battery management and electrical consumables management.

Imamura, M. S.↗

A Multiphysics Study to Improve Specific Energy of Primary Batteries for Low Temperature Operation for Deep Space Missions

Several lander missions on the outer planets such as Europa, Enceladus, and Titan require electrical power to operate scientific and communication equipment. The traditional power generation methods, such as a photovoltaic array, are not feasible as their efficiency drops significantly at these vast distances. The novel radioisotope power systems are not practical today based on current lander designs and the effectiveness of these systems. To perform in situ science on distant planets, a high specific energy battery (>700 Wh/kg) needs to operate for about 480 hours under cold temperatures (-40C or 0C) [1]. While a primary battery such as Li-CFx can provide high specific energy at room temperature, its specific capacity decreases significantly at low temperatures. One of the causes for this drop is low ion and electrical conductivity, and slower reaction kinetics. Slower transport and facile kinetics lead to an increase in the battery’s resistance and higher voltage drops during the cell operation, thus reducing specific capacity. Both the transport and kinetics show a strong dependence on temperature. Thus, a small temperature rise can lead to an increase in the reaction rate and ion conductivity; since the temperature, cell resistance, and specific capacity are interdependent. A conventional battery model accounts for ohmic, thermodynamic, and, electrochemical, and chemical decomposition heating. The ohmic heating can be controlled by designing a resistive microstructure and varying the ratios of the active materials [2]. The kinetics can be improved by increasing the surface area, reducing the particle size, or adding a catalyst. These parameters are often optimized to achieve high specific energy at room temperatures. A similar optimization study is not available at low temperatures and for a primary (high specific energy) battery. For this presentation, we will explore the effect of geometrical, microstructural, and material properties on optimal specific capacity at low temperatures through multiphysics simulations. The ion transport resistance depends on the porosity and the tortuosity of an electrode and the separator.

M. Mehta↗

Power processing

Processing of electric power has been presented as a discipline that draws on almost every field of electrical engineering, including system and control theory, communications theory, electronic network design, and power component technology. The cost of power processing equipment, which often equals that of expensive, sophisticated, and unconventional sources of electrical energy, such as solar batteries, is a significant consideration in the choice of electric power systems.

Schwarz, F. C.↗

HEPP - A low temperature Heat Pipe Experiment Package developed for flight on-board the Long Duration Exposure Facility /LDEF/

The Heat Pipe Experiment Package (HEPP) is designed to provide a flight evaluation system for low temperature heat pipes. The HEPP will be flown aboard the Long Duration Exposure Facility which will be launched and retrieved as part of the Space Shuttle program. The experiment contains two heat pipes: an axially grooved fixed conductance heat pipe and a liquid blockage thermal diode. A phase change material canister is also integrated with a radiant cooler system. Additional hardware consists of supporting electrical equipment, including electronics for signal conditioning and command functions, a data recorder, and a hermetically sealed battery which powers the experiment. A thermal model was developed to simulate the behavior of the HEPP and a ground test program was conducted to verify the predicted performance of the equipment.

Suelau, H. J.↗

DSCS 3 life test progress report

Life test considerations for a spacecraft power supply system, a battery system, designed for synchronous communication satellites for the Defense Satellite Communication System are described. The following equipment specifications considered in the life tests were: the nickel cadmium cells; bus conductors; diodes; battery casings; electric discharges; voltage drops; pressure, and temperature measurements. Battery performance data collected during eclipse periods is presented in tabular form.

Thierfelder, H. E.↗

A solar photovoltaic power system for use in Antarctica

A solar photovoltaic power system was designed and built at the NASA Lewis Research Center as part of the NASA/NSF Antarctic Space Analog Program. The system was installed at a remote field camp at Lake Hoare in the Dry Valleys, and provided a six-person field team with electrical power for personal computers and printers, lab equipment, lighting, and a small microwave oven. The system consists of three silicon photovoltaic sub-arrays delivering a total of 1.5 kWe peak power, three lead-acid gel battery modules supplying 2.4 kWh, and an electrical distribution system which delivers 120 Vac and 12 Vdc to the user. The system was modularized for ease of deployment and operation. Previously the camp has been powered by diesel generators, which have proven to be both noisy and polluting. The NSF, in an effort to reduce their dependence on diesel fuel from both an environmental and cost standpoint, is interested in the use of alternate forms of energy, such as solar power. Such a power system also will provide NASA with important data on system level deployment and operation in a remote location by a minimally trained crew, as well as validate initial integration concepts.

Kohout, Lisa L.↗