Design and Analysis of Battery Thermal Management Systems

Thermal management of battery cell packs is a critically needed technology. The purpose of this work is to design new and improved Battery Thermal Management Systems (BTMS) for use in electric airplanes. The BTMS should be 3D printable and hold twelve to sixteen 18650 batteries. To minimize aircraft’s weight, an actively air-cooled battery pack was chosen to avoid the excess weight of water-cooled and phase change material (PCM) cooled packs. As a result, significant changes were made to remove all metal in the pack and replace it with lower density polymer matrix composites (PMCs) which can be additively manufactured. Two air cooled battery pack configurations (traditional propeller fans & bladeless fans) were designed, modeled, and compared. These packs were first modeled in SolidWorks 2021 3D CAD, then imported into COMSOL MultiPhysics to be studied using the “Heat Transfer in Solids and Fluids” module. The design with the bladeless fans eliminated the need to use high conductivity heavy metal to remove unwanted thermal energy. These bladeless fans were designed entirely out of PMCs. This thermal pack design weighs 0.04 kg less than that of the traditional propeller fans design and has increased the battery pack energy density by 8.25 Wh/kg.

Thermal Management System for Battery Packs↗

Thermal Analysis on Large Format Lithium-Ion Batteries in Thermal Runaway

Lithium-ion (Li-ion) batteries can deliver electrical power across a large range of applications, and large format versions of these batteries are common in aerospace for their low mass and energy dense properties. Li-ion cells usage has increased as they are more power dense than fuel cells and have overall higher performance over lead-acid/NiCd batteries. However, Li-ion cells can experience Thermal Runaway (TR) via electro-chemical, mechanical, or thermal abuse. TR is a phenomenon where the stored energy in a cell is rapidly released along with vented gases and other effluents. A cell is generally determined to be in TR if its internal heat generation has surpassed its ability to dissipate that heat. If a Li-ion cell enters TR, propagation within the battery may occur. Propagation is the chain reaction that can occur to nearby cells due to a cell that has entered TR initially. Understanding a battery’s susceptiveness to propagation is necessary to evaluate risks associated with TR phenomenon. To determine if a battery is designed in a sufficient manner to prevent battery propagation if single cell TR occurs, testing and thermal analysis of the battery must be conducted. The presentation for TFAWS 2026 will cover considerations for battery TR thermal analysis, such as: testing methods, influences on the cells, failure mechanisms, and TR parameters. This presentation will include a walkthrough of an example battery TR thermal analysis, and the results thereof.

Lithium Ion Batteries↗

A thermal analysis of a spirally wound battery using a simple mathematical model

A two-dimensional thermal model for spirally wound batteries has been developed. The governing equation of the model is the energy balance. Convective and insulated boundary conditions are used, and the equations are solved using a finite element code called TOPAZ2D. The finite element mesh is generated using a preprocessor to TOPAZ2D called MAZE. The model is used to estimate temperature profiles within a spirally wound D-size cell. The model is applied to the lithium/thionyl chloride cell because of the thermal management problems that this cell exhibits. Simplified one-dimensional models are presented that can be used to predict best and worst temperature profiles. The two-dimensional model is used to predict the regions of maximum temperature within the spirally wound cell. Normal discharge as well as thermal runaway conditions are investigated.

Evans, T. I.↗

Operationally Responsive Space Standard Bus Battery Thermal Balance Testing and Heat Dissipation Analysis

The focus of this paper will be on the thermal balance testing for the Operationally Responsive Space Standard Bus Battery. The Standard Bus thermal design required that the battery be isolated from the bus itself. This required the battery to have its own thermal control, including heaters and a radiator surface. Since the battery was not ready for testing during the overall bus thermal balance testing, a separate test was conducted to verify the thermal design for the battery. This paper will discuss in detail, the test set up, test procedure, and results from this test. Additionally this paper will consider the methods taken to determine the heat dissipation of the battery during charge and discharge. It seems that the heat dissipation for Lithium Ion batteries is relatively unknown and hard to quantify. The methods used during test and the post test analysis to estimate the heat dissipation of the battery will be discussed.

Marley, Mike↗

Characterization of the physico-chemical properties of polymeric materials for aerospace flight

Electrodes and electrolytes of nickel cadmium sealed batteries were analyzed. Different thermal analysis of negative and positive battery electrodes was conducted and the temperature ranges of occurrence of endotherms indicating decomposition of cadmium hydroxide and nickel hydroxide are identified. Atomic absorption spectroscopy was used to analyze electrodes and electrolytes for traces of nickel, cadmium, cobalt, and potassium. Calibration curves and data are given for each sample analyzed. Instrumentation and analytical procedures used for each method are described.

Rock, M.↗

Thermal-Fluid Analysis of a Liquid-Cooled Battery Module for Electrified Aircraft

The development of safe, energy-dense batteries is critical to advancing hybrid electric and fully electrified aircraft propulsion. Achieving this capability requires a thermal management system that can maintain battery performance and safety under demanding operational conditions. The objective of this project is to support the maturation of next-generation lithium-ion batteries for electrified aircraft by conducting performance testing on integrated battery modules, specifically a 2-cell series configuration module housed within an aluminum enclosure. Designed to operate at a nominal 7.2 V with discharge rates up to 2.5C, the module will eventually be used to power an electric motor and DC-DC converter, generating substantial thermal loads that must be effectively managed to increase the usable energy and power density of electrified aircraft. To address these thermal challenges, this study presents the development and thermal-fluid analysis of a liquid-cooled thermal management system. While the full aircraft architecture utilizes an eight-string configuration, the present work evaluates a representative single-string water coolant loop to characterize baseline performance. The active cooling loop circulates water through a reservoir, pump, the battery module, and a variable area flow meter. Key performance metrics including component-level temperatures, mass flow rates, and pressure drops are quantified across the loop. Across discharge rates ranging from 0.5C to 2.5C, the active thermal loop consistently and effectively removed heat from the module, validating the design approach and confirming readiness for further development. The validated thermal performance indicates a path toward scalable battery modules that could enable energy and power dense systems for hybrid electric aircraft.

Electrified Aircraft↗

Development and Application of a Novel Calorimetry Technique for the Study of Lithium-Ion Cell Thermal Runaway

Lithium-ion battery technology is widely used and is attractive due to demonstrated specific energies in the 200-300 W-hr/kg range. The excellent, mass-efficient energy storage capability of lithium-ion batteries has led to their use on many aerospace platforms. However, lithium-ion batteries can exhibit thermal runaway behavior wherein stored electrochemical energy is released rapidly as a result of thermal or mechanical failure, electrochemical abuse, internal or external short circuiting. A single cell undergoing thermal runaway within a battery has the potential to induce thermal runaway in adjacent cells if heat dissipation is not properly managed and can result in a catastrophic failure of the battery. Designing batteries that are resistant to thermal runaway propagation requires an understanding of, not only, total energy yield but also the means by which that energy is liberated from the cell. While Accelerating Rate Calorimetry and other techniques provide total thermal runaway energy yield, they do not provide the fractional breakdown of energy liberated via conduction through the cell casing from that which is vented from the cell as hot gases and effluents. Such data are needed to inform battery thermal design and analysis. To measure the total energy yield, the fraction conducted through the cell casing, and the fraction lost due to gases and effluents, NASA developed Fractional Thermal Runaway Calorimetry (FTRC). Two calorimeters have been developed and demonstrated, the Small-format- and Large-format Fractional Thermal Runaway Calorimeters (S-FTRC and L-FTRC, respectively). The technique has been successfully applied to small- and large-format cells (2.4-3.5 Ah and >100 Ah capacity, respectively) and has given new insights into Li-ion cell thermal runaway. Development of the calorimeters is discussed and results from the initial thermal runaway testing campaigns are presented.

Lithium-Ion Cell↗

Validation of Modified Wine-Rack Thermal Design for Nickel-Hydrogen Batteries in Landsat-7 Spacecraft Thermal Vacuum Test and in Flight

A heritage wine-rack thermal/mechanical design for the nickel-hydrogen batteries was the baseline at the Landsat-7 Preliminary Design Review. An integrated thermal and power analysis of the batteries performed by the author in 1994 revealed that the maximum cell-to-cell gradient was 6.6 C. The author proposed modifying the heritage wine-rack design by enhancing heat conduction from cells to cells, and from cells to battery frame. At the 1995 Intersociety Energy Conversion Engineering Conference (IECEC), the author presented a paper on methods of modifying the wine-rack design. It showed that the modified wine-rack option, which uses a metallic filler, could reduce the maximum cell-to-cell temperature gradient to 1.30 C, and could also reduce the maximum cell temperature by as much as 80 C. That design concept was adopted by the Landsat7 Project Office, and a design change was made at the Critical Design Review. Results of the spacecraft thermal vacuum and thermal balance tests, and temperature data in flight show that the temperatures of the battery cells are very uniform. The maximum cell-to-cell gradient is 1.50 C. They validate the modified wine-rack thermal design.

Choi, Michael K.↗

A high power lithium thionyl chloride battery for space applications

A high power, 28 V, 330 A h, active lithium thionyl chloride battery has been developed for use as main and payload power sources on an expendable launch vehicle. Nine prismatic cells, along with the required electrical components and a built-in heater system, are efficiently packaged resulting in significant weight savings over presently used silver-zinc batteries. The high rate capability is achieved by designing the cells with a large electrochemical surface area and impregnating an electrocatalyst, polymeric phthalocyanine, into the carbon cathodes. Passivation effects are reduced with the addition of sulfur dioxide into the thionyl chloride electrolyte solution. The results of conducting a detailed thermal analysis are utilized to establish the heater design parameters and the thermal insulation requirements of the battery. An analysis of cell internal pressure and vent characteristics clearly illustrates the margins of safety under different operating conditions. Performance of fresh cells is discussed using polarization scan and discharge data at different rates and temperatures. Self-discharge rate is estimated based upon test results on cells after storage. Results of testing a complete prototype battery are described.

Shah, Pinakin M.↗

25th Space Simulation Conference. Environmental Testing: The Earth-Space Connection

Topics covered include: Methods of Helium Injection and Removal for Heat Transfer Augmentation; The ESA Large Space Simulator Mechanical Ground Support Equipment for Spacecraft Testing; Temperature Stability and Control Requirements for Thermal Vacuum/Thermal Balance Testing of the Aquarius Radiometer; The Liquid Nitrogen System for Chamber A: A Change from Original Forced Flow Design to a Natural Flow (Thermo Siphon) System; Return to Mercury: A Comparison of Solar Simulation and Flight Data for the MESSENGER Spacecraft; Floating Pressure Conversion and Equipment Upgrades of Two 3.5kw, 20k, Helium Refrigerators; Affect of Air Leakage into a Thermal-Vacuum Chamber on Helium Refrigeration Heat Load; Special ISO Class 6 Cleanroom for the Lunar Reconnaissance Orbiter (LRO) Project; A State-of-the-Art Contamination Effects Research and Test Facility Martian Dust Simulator; Cleanroom Design Practices and Their Influence on Particle Counts; Extra Terrestrial Environmental Chamber Design; Contamination Sources Effects Analysis (CSEA) - A Tool to Balance Cost/Schedule While Managing Facility Availability; SES and Acoustics at GSFC; HST Super Lightweight Interchangeable Carrier (SLIC) Static Test; Virtual Shaker Testing: Simulation Technology Improves Vibration Test Performance; Estimating Shock Spectra: Extensions beyond GEVS; Structural Dynamic Analysis of a Spacecraft Multi-DOF Shaker Table; Direct Field Acoustic Testing; Manufacture of Cryoshroud Surfaces for Space Simulation Chambers; The New LOTIS Test Facility; Thermal Vacuum Control Systems Options for Test Facilities; Extremely High Vacuum Chamber for Low Outgassing Processing at NASA Goddard; Precision Cleaning - Path to Premier; The New Anechoic Shielded Chambers Designed for Space and Commercial Applications at LIT; Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar; Thermal (Silicon Diode) Data Acquisition System; Aquarius's Instrument Science Data System (ISDS) Automated to Acquire, Process, Trend Data and Produce Radiometric System Assessment Reports; Exhaustive Thresholds and Resistance Checkpoints; Reconfigurable HIL Testing of Earth Satellites; FPGA Control System for the Automated Test of MicroShutters; Ongoing Capabilities and Developments of Re-Entry Plasma Ground Tests at EADS-ASTRIUM; Operationally Responsive Space Standard Bus Battery Thermal Balance Testing and Heat Dissipation Analysis; Galileo - The Serial-Production AIT Challenge; The Space Systems Environmental Test Facility Database (SSETFD), Website Development Status; Simulated Reentry Heating by Torching; Micro-Vibration Measurements on Thermally Loaded Multi-Layer Insulation Samples in Vacuum; High Temperature Life Testing of 80Ni-20Cr Wire in a Simulated Mars Atmosphere for the Sample Analysis at Mars (SAM) Instrument Suit Gas Processing System (GPS) Carbon Dioxide Scrubber; The Planning and Implementation of Test Facility Improvements; and Development of a Silicon Carbide Molecular Beam Nozzle for Simulation Planetary Flybys and Low-Earth Orbit.

Packard, Edward↗

Coupling Fractional Thermal Runaway Calorimetry (FTRC) Results with Statistical Analysis Methods

Important factors to consider when optimizing Lithium-ion (Li-ion) battery thermal management systems, from a battery safety perspective, include the total energy released during a single cell thermal runaway (TR) event and the fraction of the total energy that is released through the cell casing versus through the ejecta material. A fractional thermal runaway calorimeter (FTRC) was used to examine the TR behavior of the following 18650-format Li-ion cells: (1) Molicel 18650-J, (2) LG 18650-HG2, (3) Samsung 18650-30Q, (4) 3.35 Ah LG 18650 test cell, (5) Sony 18650-VC7, and (6) LG 18650-MJ1. These cells were intentionally selected to represent a variety of manufacturers, chemistries, capacities, and safety features. Because of the large number of random and non-random variables associated with the FTRC results, a linear regression model, developed using engineering statistical methods, was utilized to provide final interpretation of the TR behavior for each cell type and design variable combination.

Walker, William↗

Aerothermal Shape Optimization of Actively-Cooled Battery Packs using Conjugate Heat Transfer

Thermal management for battery is important for electric aircraft because battery temperature is critically important to vehicle safety, and it also has direct impact on the efficiency of the battery system. Because ambient air is a readily available resource for aircraft, this paper considers an active cooling concept with forced convection of ambient air through the battery pack. Conjugate heat transfer analysis is used to solve the coupled aero-thermal problem, which consists of a finite-volume computational fluid dynamics solver for the fluid domain, and a conduction heat transfer solver for the solid domain. A mixed Neumann and Dirichlet boundary condition is developed for the fluid-solid interface, which allows the solid domain to completely submerge in the fluid domain. A gradient-based optimization method is adopted, and the discrete adjoint approach implemented in DAFoam is used to efficiently compute the gradients. The aero-thermal coupling for primal analysis and gradient computation is handled using the OpenMDAO-based MPhys framework. A constant heat source is prescribed for the battery cells, and the battery shape (design variable) is optimized to minimize cooling pump power and battery weight (composite objective function) while keeping the battery temperature below a threshold (constraint). The optimized design achieves a 44.6% and 1.5% reduction in the cooling pump power and battery weight, respectively, and the maximal temperature constraint is satisfied. This work has the potential to reduce battery-pack weight, improve performance, and reduce the weight of thermal management systems for electric vertical take-off and landing aircraft.

thermal management↗

Aerothermal Shape Optimization of Actively-Cooled Battery Packs Using Conjugate Heat Transfer

Thermal management for battery is important for electric aircraft because battery temperature is critically important to vehicle safety, and it also has direct impact on the efficiency of the battery system. Because ambient air is a readily available resource for aircraft, this paper considers an active cooling concept with forced convection of ambient air through the battery pack. Conjugate heat transfer analysis is used to solve the coupled aero-thermal problem, which consists of a finite-volume computational fluid dynamics solver for the fluid domain, and a conduction heat transfer solver for the solid domain. A mixed Neumann and Dirichlet boundary condition is developed for the fluid-solid interface, which allows the solid domain to completely submerge in the fluid domain. A gradient-based optimization method is adopted, and the discrete adjoint approach implemented in DAFoam is used to efficiently compute the gradients. The aero-thermal coupling for primal analysis and gradient computation is handled using the OpenMDAO-based MPhys framework. A constant heat source is prescribed for the battery cells, and the battery shape (design variable) is optimized to minimize cooling pump power and battery weight (composite objective function) while keeping the battery temperature below a threshold (constraint). The optimized design achieves a 44.6% and 1.5% reduction in the cooling pump power and battery weight, respectively, and the maximal temperature constraint is satisfied. This work has the potential to reduce battery-pack weight, improve performance, and reduce the weight of thermal management systems for electric vertical take-off and landing aircraft.

heat transfer↗

Investigating On-Orbit Attitude Determination Anomalies for the Solar Dynamics Observatory Mission

The Solar Dynamics Observatory (SDO) was launched on February 11, 2010 from Kennedy Space Center on an Atlas V launch vehicle into a geosynchronous transfer orbit. SDO carries a suite of three scientific instruments, whose observations are intended to promote a more complete understanding of the Sun and its effects on the Earth's environment. After a successful launch, separation, and initial Sun acquisition, the launch and flight operations teams dove into a commissioning campaign that included, among other things, checkout and calibration of the fine attitude sensors and checkout of the Kalman filter (KF) and the spacecraft s inertial pointing and science control modes. In addition, initial calibration of the science instruments was also accomplished. During that process of KF and controller checkout, several interesting observations were noticed and investigated. The SDO fine attitude sensors consist of one Adcole Digital Sun Sensor (DSS), two Galileo Avionica (GA) quaternion-output Star Trackers (STs), and three Kearfott Two-Axis Rate Assemblies (hereafter called inertial reference units, or IRUs). Initial checkout of the fine attitude sensors indicated that all sensors appeared to be functioning properly. Initial calibration maneuvers were planned and executed to update scale factors, drift rate biases, and alignments of the IRUs. After updating the IRU parameters, the KF was initialized and quickly reached convergence. Over the next few hours, it became apparent that there was an oscillation in the sensor residuals and the KF estimation of the IRU bias. A concentrated investigation ensued to determine the cause of the oscillations, their effect on mission requirements, and how to mitigate them. The ensuing analysis determined that the oscillations seen were, in fact, due to an oscillation in the IRU biases. The low frequencies of the oscillations passed through the KF, were well within the controller bandwidth, and therefore the spacecraft was actually following the oscillating biases, resulting in movement of the spacecraft on the order of plus or minus 20 arcsec. Though this level of error met the ACS attitude knowledge requirement of [35, 70, 70] arcsec, 3 sigma, the desire of the ACS and instrument teams was to remove as much of the oscillation as possible. The Kearfott IRUs have an internal temperature controller, designed to maintain the IRU temperature at a constant temperature of approximately 70 C, thus minimizing the change in the bias drift and scale factors of the mechanical gyros. During ground testing of the observatory, it was discovered that the 83-Hz control cycle of the IRU heaters put a tremendous amount of stress on the spacecraft battery. Analysis by the power systems team indicated that the constant charge/discharge on the battery due to the IRU thermal control cycle could potentially limit the life of the battery. After much analysis, the decision was made not to run the internal IRU heaters. Analysis of on orbit data revealed that the oscillations in the IRU bias had a connection to the temperature of the IRU; changes in IRU temperature resulted in changes in the amplitude and period of the IRU biases. Several mitigating solutions were investigated, the result of which was to tune the KF with larger IRU noise assumptions which allows the KF to follow and correct for the time-varying IRU biases.

Vess, Melissa F.↗

Modeling Spacecraft Power Systems Using the SPACE Code

The NASA Glenn Research Center’s Power Architecture and Analysis Branch performs spacecraft electrical power system (EPS) performance analysis using the System Power Analysis for Capability Evaluation (SPACE) model. Accurately predicting EPS performance requires a wide range of inputs, including the spacecraft’s position, attitude, solar array temperature, load demand, and data on the EPS itself. By operating as a combined analysis tool with integrated orbit mechanics, attitude, shadowing, thermal, solar array, battery, and electrical component models, SPACE provides flexibility for the analyst to examine various scenarios without a time-consuming iterative process involving separate analysis tools and groups. SPACE also achieves short run times by tailoring the complexity of the included models, providing enough fidelity to ensure accurate EPS performance predictions without being bogged down by unnecessary detail. These advantages that SPACE has over similar power system models has contributed to its successful use on a variety of human spaceflight programs for over three decades, and makes it applicable across the development cycle from early conceptual design up through on-orbit operations.

Electrical Power System↗

Advanced Dependent Pressure Vessel (DPV) nickel-hydrogen spacecraft cell and battery design

The dependent pressure vessel (DPV) nickel-hydrogen (NiH2) battery is being developed as a potential spacecraft battery design for both military and commercial satellites. Individual pressure vessel (IPV) NiH2 batteries are currently flying on more than 70 Earth orbital satellites and have accumulated more than 140,000,000 cell-hours in actual spacecraft operation. The limitations of standard NiH2 IPV flight battery technology are primarily related to the internal cell design and the battery packaging issues associated with grouping multiple cylindrical cells. The DPV cell design offers higher specific energy and reduced cost, while retaining the established IPV NiH2 technology flight heritage and database. The advanced cell design offers a more efficient mechanical, electrical and thermal cell configuration and a reduced parts count. The internal electrode stack is a prismatic flat-plate arrangement. The flat individual cell pressure vessel provides a maximum direct thermal path for removing heat from the electrode stack. The cell geometry also minimizes multiple-cell battery packaging constraints by using an established end-plateltie-rod battery design. A major design advantage is that the battery support structure is efficiently required to restrain only the force applied to a portion of the end cell. As the cells are stacked in series to achieve the desired system voltage, this increment of the total battery weight becomes small. The geometry of the DPV cell promotes compact, minimum volume packaging and places all cell terminals along the length of the battery. The resulting ability to minimize intercell wiring offers additional design simplicity and significant weight savings. The DPV battery design offers significant cost and weight savings advantages while providing minimal design risks. Cell and battery level design issues will be addressed including mechanical, electrical and thermal design aspects. A design performance analysis will be presented at both the cell and battery level. The DPV is capable of delivering up to 76 Watt-hours per kilogram (Wh/kg) at the cell level and 70 Wh/kg at the full battery level. This represents a 40 percent increase in specific energy at the cell level and a 60 percent increase in specific energy at the battery level compared to current IPV NiH2 technology.