Search NASA⌕ Search

SEARCH · Search NASA

Results for “battery voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High voltage battery cell scanner development

Battery cell voltage scanners have been previously used in low voltage spacecraft applications. In connection with future missions involving an employment of high-power high voltage power subsystems and/or autonomous power subsystem management for unattended operation, it will be necessary to utilize battery cell voltage scanners to provide battery cell voltage information for early detection of impending battery cell degradation/failures. In preparation for such missions, a novel battery cell voltage scanner design has been developed. The novel design makes use of low voltage circuit modules which can be applied to high voltage batteries in a building block fashion. A description is presented of the design concept and test results of the high voltage battery cell scanner, and its operation with an autonomously managed power subsystem is discussed.

Lepisto, J. W.↗

Performance of Li-Ion Cells Under Battery Voltage Charge Control

A study consisting of electrochemical characterization and Low-Earth-Orbit (LEO) cycling of Li-Ion cells from three vendors was initiated in 1999 to determine the cycling performance and to infuse the new technology in the future NASA missions. The 8-cell batteries included in this evaluation are prismatic cells manufactured by Mine Safety Appliances Company (MSA), cylindrical cells manufactured by SAFT and prismatic cells manufactured by Yardney Technical Products, Inc. (YTP). The three batteries were cycle tested in the LEO regime at 40% depth of discharge, and under a charge control technique that consists of battery voltage clamp with a current taper. The initial testing was conducted at 20 C; however, the batteries were cycled also intermittently at low temperatures. YTP 20 Ah cells consisted of mixed-oxide (Co and Ni) positive, graphitic carbon negative, LIPF6 salt mixed with organic carbonate solvents. The battery voltage clamp was 32 V. The low temperature cycling tests started after 4575 cycles at 20 C. The cells were not capable of cycling. at low temperature since the charge acceptance at battery level was poor. There was a cell in the battery that showed too high an end-of-charge (EOC) voltage thereby limiting the ability to charge the rest of the cells in the battery. The battery has completed 6714 cycles. SAFT 12 Ah cells consisted of mixed-oxide (Co and NO positive, graphitic carbon negative, LiPF6 salt mixed with organic carbonate solvents. The battery voltage clamp was for 30.8 V. The low temperature cycling tests started after 4594 cycles at 20 C. A cell that showed low end of discharge (EOD) and EOC voltages and three other cells that showed higher EOC voltages limited the charge acceptance at the selected voltage limit during charge. The cells were capable of cycling at 10 C and 0 C but the charge voltage limit had to be increased to 34.3 V (4.3 V per cell). The low temperature cycling may have induced poor chargeability since the voltage had to be increased to achieve the required charge input. The battery has completed 6226 cycles. MSA 10 Ah cells consisted of Co oxide positive, graphitic carbon negative, LiPF6 salt mixed with organic carbonate solvents. The battery voltage clamp was 30.8 V. The low temperature cycling tests were started after 2182 cycles at 20 C. The cells were capable of cycling at 10 C and 0 C. Like SAFT, the voltage limit on charge had to be increased to 36 V (4.5 V per cell). There was a cell (cell S/N 13) in the battery that showed poor performance features such as low EOD voltage and high EOC voltage. The battery has completed 3441 cycles. A reconditioning procedure that consisted of C15 charge to a taper current of C/100 and C/20 discharge improved the voltage behavior of SAFT and MSA cells with no significant effect on YTP cells. We have demonstrated that the charge operation with VT clamp at battery rather than at cell level is feasible for onboard Li-Ion battery operation.

Rao, Gopalakrishna M.↗

Reliable low-cost battery voltage indicator for light aircraft and automobiles

Voltage indicator fits into cigarette lighter socket and utilizes light emitting and Zener diodes to display three levels of battery voltage. Indicator is superior to typical conventional electrical system indicators in that it gives a positive discrete indication of battery voltage. It is simple, inexpensive, and rugged.

Miller, R. L.↗

COTS Li-Ion Cells in High Voltage Batteries

Testing at NASA JSC and COMDEV shows that Commercial Off the Shelf (COTS) Li Ion cells can not be used in high voltage batteries safely without considering the voltage stresses that may be put on the protective devices in them during failure modes.

Davies, Francis↗

Performance of Li-Ion Cells Under Battery Voltage Charge Control

Li-ion cells manufactured by YTP, SAFT, and MSA have completed 6714, 6226, and 3441 cycles, respectively. An increase in the charge voltage limit was required in all cases to maintain the discharge voltage. SAFT and MSA cells were capable of cycling at -10 C and 0 C with an increase in the charge voltage limit, whereas Yardney cells could not be cycled. Reconditioning improved the discharge voltage of SAFT and MSA cells; it is important to note that the effect has been temporary as in Ni-H and Ni-Cd batteries. It was demonstrated that the charge operation with VT clamp at battery rather than at cell level is feasible. Continuation of testing depends on the health of the cells and on the funding situation.

Vaidyanathan, Hari↗

Safety Performance of Small Lithium-Ion Cells in High Voltage Batteries

Topics covered include: Small-cell EAPU work done by NASA-JSC & COM DEV; Looking at safety features (short circuit protection - PTCs); Early tests showed that long strings do not withstand short circuit; a) Some PTCs experience large negative voltages; b) Destructive results. Solution: group cells into shorter substrings, with bypass diodes Work included: a) Tests with single cells shorted; b) Tests with single cells with imposed-negative voltages; c) 6s, 7s and 8s string shorts; and d) Tests with protection scheme in place, on 12s and 41s x 5p.

Cowles, Philip R.↗

Safe, High Power / Voltage Battery Design Challenges

NASA seeks safe, high performing battery module designs that can deliver 3C discharge rates continuously, achieve 160 Wh/kg, and is passively propagation resistant to a single cell thermal runaway event. One solution is presented that uses a patented oscillating heat pipe technology for thermal management. Combined with light weight packaging and a new commercially available gas permeable vent port, all 5 preliminary safety tests results performed to date are showing ample margins.

High power↗

Battery Cell Voltage Sensing and Balancing Using Addressable Transformers

A document discusses the use of saturating transformers in a matrix arrangement to address individual cells in a high voltage battery. This arrangement is able to monitor and charge individual cells while limiting the complexity of circuitry in the battery. The arrangement has inherent galvanic isolation, low cell leakage currents, and allows a single bad cell in a battery of several hundred cells to be easily spotted.

Davies, Francis↗

GPS on-orbit battery performance

Three batteries designed for the GPS system were evaluated. The batteries were wired together, and during the eclipse period were discharged through parallel diodes into a boost converter which then boosted the battery voltage up to the totally regulated bus voltage. Each battery, with a system life of approximately five years, had its own charger. During testing the battery was maintained or used on trickle charge. Data are presented for the battery capacity during the reconditioning. Raw data for each eclipse period and calculations for the average discharge voltage for each battery are given. Thermal cycling for one of the batteries and reconditioning cycles and regimes for all of the batteries are discussed. A reconditioning discharge curve is also given. The problem of temperature cycling in one of the batteries was resolved by redesigning the battery radiator system.

Kasten, J. L.↗

Appearance of second plateau voltage

Batteries used in TIROS N and NOAA A spacecraft were performance tested. Voltage levels are plotted in a series of graphs. Cell packs from four different manufacturers are evaluated for depth of charge.

Halpert, G.↗

Update of the IUE battery in-flight performance

The in-flight performance data of two 17-cell, 6-ampere-hour nickel cadmium spacecraft batteries are presented covering 22 months of operation. Fluctuations in the battery voltage and the battery temperature are presented for spacecraft movement throughout a beta range of 0 to 130 deg. The battery discharge voltages during the peak eclipse seasons, daily seasons, and daily eclipse periods are noted. Finally, the spacecraft data are compared to data from a 6-ampere-hour test pack and test flight data.

Tiller, S. E.↗

The 20 kW battery study program

Six battery configurations were selected for detailed study and these are described. A computer program was modified for use in estimation of the weights, costs, and reliabilities of each of the configurations, as a function of several important independent variables, such as system voltage, battery voltage ratio (battery voltage/bus voltage), and the number of parallel units into which each of the components of the power subsystem was divided. The computer program was used to develop the relationship between the independent variables alone and in combination, and the dependent variables: weight, cost, and availability. Parametric data, including power loss curves, are given.

Source record↗

Battery Charge Equalizer with Transformer Array

High-power batteries generally consist of a series connection of many cells or cell banks. In order to maintain high performance over battery life, it is desirable to keep the state of charge of all the cell banks equal. A method provides individual charging for battery cells in a large, high-voltage battery array with a minimum number of transformers while maintaining reasonable efficiency. This is designed to augment a simple highcurrent charger that supplies the main charge energy. The innovation will form part of a larger battery charge system. It consists of a transformer array connected to the battery array through rectification and filtering circuits. The transformer array is connected to a drive circuit and a timing and control circuit that allow individual battery cells or cell banks to be charged. The timing circuit and control circuit connect to a charge controller that uses battery instrumentation to determine which battery bank to charge. It is important to note that the innovation can charge an individual cell bank at the same time that the main battery charger is charging the high-voltage battery. The fact that the battery cell banks are at a non-zero voltage, and that they are all at similar voltages, can be used to allow charging of individual cell banks. A set of transformers can be connected with secondary windings in series to make weighted sums of the voltages on the primaries.

Davies, Francis↗

HST Replacement Battery Initial Performance

The Hubble Space Telescope (HST) original Nickel-Hydrogen (NiH2) batteries were replaced during the Servicing Mission 4 (SM4) after 19 years and one month on orbit.The purpose of this presentation is to highlight the findings from the assessment of the initial sm4 replacement battery performance. The batteries are described, the 0 C capacity is reviewed, descriptions, charts and tables reviewing the State Of Charge (SOC) Performance, the Battery Voltage Performance, the battery impedance, the minimum voltage performance, the thermal performance, the battery current, and the battery system recharge ratio,

Krol, Stan↗

Limitations of Internal Protective Devices in High-Voltage/High-Capacity Batteries Using Lithium-Ion Cylindrical Commercial Cells

Most commercial cylindrical 18650 Lithium-Ion (Li-Ion) cells have two internal protective devices: the Positive Temperature Coefficient (PTC) and the Current Interrupt Device (CID). The PTC protects the cells under external short conditions and the CID protects the cells under overcharge conditions. While proven to be effective at the single cell and small-size battery levels, these devices do not always offer protection when used in high-voltage and high-capacity battery designs.

Limitations of Internal Protective Devices↗

Soft-short management and remediation in 10-year-old NiCds in Geo orbit

After 10 years in Geo orbit, during the spring 1993 eclipse season, soft shorts occurred in cells of two of the three batteries on the F2R spacecraft On battery #1, the cell soft short turned suddenly into a hard short; the resulting sudden 1.2V fall in battery voltage and rise in temperature was observed via telemetry. On battery #3, the deleterious impact of its soft short increased day by day, manifesting itself as a drop in battery voltage part-way through each eclipse, causing high loading on the remaining good battery. This paper reports how by planned charge management, including applying (against-the-book) overcharge ratios (C/D) exceeding 1.75, the battery #3 cell soft short was 'built down' until the cell voltage fade ceased. The problem with the battery #3 soft-shorted cell was fought with partial success throughout the latter half of the fall 93 season, and the lessons learned were applied to alleviate the problem during the spring 94 and fall 94 eclipse seasons. The life of the spacecraft was successfully prolonged until it was retired in March 1995.

Flordeliza, Nicanor A.↗

The Atmosphere Explorer power subsystem

The design and operation of the power subsystem for the Atmospheric Explorer spacecraft are discussed. The additional functional redundancy which was added in several component areas to improve the overall subsystem reliability is analyzed. The battery charging technique has been modified to include third electrode overcharge control. The automatic removal of all battery charge is provided to correct abnormally high battery voltages. An undervoltage detector has been added which removes all nonessential spacecraft loads when the battery voltage falls below a given level. All automatic functions can be over-ridden by ground command.

Obenschain, A.↗

Thin Rechargeable Batteries for CMOS SRAM Memory Protection

New rechargeable battery technology is described and compared with classical primary battery back-up of SRAM PC cards. Thin solid polymer electrolyte cells with the thickness of TSOP memory components (1 mm nominal, 1.1 mm max) and capacities of 14 mAh/sq cm can replace coin cells. The SRAM PC cards with permanently installed rechargeable cells and optional electrochromic low battery voltage indicators will free the periodic PC card user from having to 'feed' their PC cards with coin cells and will allow a quick visual check of stored cards for their battery voltage status.

Crouse, Dennis N.↗