Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam broadening”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Phase-Only Beam Broadening of Contiguous Uniform Subarrayed Arrays

In modern antenna systems, beam broadening of subarrayed arrays provides continuous coverage of a wide angular extent in a cost-effective manner. While many methods have been published that address beam broadening of traditional (non-subarrayed) arrays, there is a knowledge gap in the published literature with respect to efficient beam broadening of contiguous uniform subarrayed arrays. This article presents efficient methods for beam broadening of contiguous uniform subarrayed arrays where the excitation of each element is not individually controlled, but the elements of the array are grouped together as subarrays to have the same element excitations. Particularly, this article focuses on phase-only optimization to preserve maximum power output. Additionally, three modilied iterative Fourier transform (IFT) methods and one genetic algorithm (GA) are presented to efliciently search the vast solution space of possible phase settings for a solution that satislies the desired broadened pattern. These methods are evaluated on idealized 1 x 40 and 1 x 80 linear arrays with live element subarrays and 40 x 40 and 80 x 80 element rectangular arrays with 5 x 5 element subarrays. The proposed modilied IFT methods are found to be faster than the GA approach, while the GA approach only offers a few percentage points of better effectiveness.

42 ENGINEERING↗

Experimental study of energy-dependent angular broadening of MeV electron beams for high-resolution imaging in thick samples

In scanning transmission electron microscopy (STEM), spatial resolution is primarily influenced by the projected size of the electron probe within the specimen. In thin samples, a large semi-convergence angle enables a tightly focused beam and sub-nanometer resolution. However, in thick specimens, resolution is fundamentally limited by transverse beam broadening from multiple large-angle scattering events—for example, a probe with 10 mrad angular divergence can broaden by ∼100 nm over a 10 μm path. Since this broadening scales inversely with beam energy, MeV-STEM offers a promising route for high-resolution imaging in thick materials. To quantitatively assess this effect, we performed high-precision measurements at UCLA’s PEGASUS beamline, characterizing beam divergence and intensity profiles for 3–8 MeV electrons transmitted through a wedged-silicon sample of varying thickness. Our results reconcile discrepancies among analytical models and validate Monte Carlo simulations. Here, we find that increasing beam energy from 3.0 to 5.8 MeV reduces angular broadening by a factor of 2.6, with diminishing returns observed at 7.6 MeV. These findings provide a quantitative framework for optimizing MeV-STEM parameters in high-resolution imaging of thick biological and microelectronic specimens, and for guiding beam energy selection in other advanced imaging modes beyond STEM.

36 MATERIALS SCIENCE↗

Resolving ECRH deposition broadening due to edge turbulence in DIII-D

Microwave heat pulse propagation experiments have demonstrated a correlation between millimeter-scale turbulence and deposition profile broadening of electron cyclotron (EC) waves on the DIII-D tokamak. In a set of discharges in DIII-D, a variation in edge density fluctuations on the mm-scale is associated with 40%–150% broader deposition profiles, expressed in terms of normalized minor radius, as compared with equilibrium ray tracing. The 1D power profile is determined from transport analysis of the electron temperature response to EC power modulation using perturbative analysis with a square wave power modulation at 20–70 Hz, producing a series of Fourier harmonics that are fit collectively to resolve transport. Fitting an integrated heat flux expressed in the Fourier basis of the modulation to diffusive, convective, and coupled transport terms in a linear model can resolve the broadened EC deposition width from the power perturbation to resolve a broadening in each case. The best fit degree of beam broadening observed scales approximately linearly with the Doppler backscattering measured fluctuation level in the steep gradient region. Quantifying the effect of edge fluctuation broadening on EC current drive power needs of future devices will require 3D full-wave codes that can be validated on the current generation of machines. These DIII-D experiments provide a quantitative measure of fluctuation effects and a dataset to benchmark full-wave simulations that can model and eventually predict nonlinear effects neglected by 1D equilibrium beam and ray tracing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Millimeter-wave beam scattering and induced broadening by plasma turbulence in the TCV tokamak

The scattering of millimeter-wave beams from electron density fluctuations and the associated beam broadening are experimentally demonstrated. Using a dedicated setup, instantaneous deflection and (de-)focusing of the beam due to density blobs on the beam path are shown to agree with full-wave simulations. The detected time-averaged wave power transmitted through the turbulent plasma is reproduced by the radiative-transfer model implemented in the WKBeam code, which predicts a ~50% turbulence-induced broadening of the beam cross-section. Finally, the role of core turbulence for the considered geometry is highlighted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples

Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.

36 MATERIALS SCIENCE↗

Broadening of microwave heating beams in the DIII-D tokamak by edge turbulence

Abstract We have demonstrated for the first time that turbulent plasma density fluctuations in the edge of the DIII-D tokamak are responsible for substantial broadening of an injected microwave beam by successful quantitative comparison between experimental observations and first principles 2D full-wave simulations. The broadening of the beam has important implications for control of tokamak discharges through localized electron cyclotron deposition needed for eliminating magnetohydrodynamic instabilities. This new predictive capability is mandatory to design & operate present & future tokamaks in such a way that microwave heating schemes achieve their intended objectives.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimize Electron Beam Energy toward In Situ Imaging of Thick Frozen Bio-Samples with Nanometer Resolution Using MeV-STEM

To optimize electron energy for in situ imaging of large biological samples up to 10 μm in thickness with nanoscale resolutions, we implemented an analytical model based on elastic and inelastic characteristic angles. This model has been benchmarked by Monte Carlo simulations and can be used to predict the transverse beam size broadening as a function of electron energy while the probe beam traverses through the sample. As a result, the optimal choice of the electron beam energy can be realized. In addition, the impact of the dose-limited resolution was analysed. While the sample thickness is less than 10 μm, there exists an optimal electron beam energy below 10 MeV regarding a specific sample thickness. However, for samples thicker than 10 μm, the optimal beam energy is 10 MeV or higher depending on the sample thickness, and the ultimate resolution could become worse with the increase in the sample thickness. Moreover, a MeV-STEM column based on a two-stage lens system can be applied to reduce the beam size from one micron at aperture to one nanometre at the sample with the energy tuning range from 3 to 10 MeV. In conjunction with the state-of-the-art ultralow emittance electron source that we recently implemented, the maximum size of an electron beam when it traverses through an up to 10 μm thick bio-sample can be kept less than 10 nm . This is a critical step toward the in situ imaging of large, thick biological samples with nanometer resolution.

36 MATERIALS SCIENCE↗

Optimize electron beam energy toward in-situ imaging of large thick bio-samples with nanometer resolution

To optimize electron energy toward in-situ imaging large bio-samples up to 10-μm thickness with nanoscale resolution, we implemented an analytical model based on elastic and inelastic characteristic angles 1. This model can be used to predict the transverse beam size broadening as a function of electron energy while the probe beam traverses through the sample. As result, the optimal choice of the electron beam energy can be realized. While the sample thickness is less than 10 μm, there exists an optimal electron beam energy below 10 MeV regarding a specific sample thickness. However, for samples thicker than 10 μm, the optimal beam energy is 10 MeV, and the ultimate resolution could become worse with the increase of the sample thickness.

43 PARTICLE ACCELERATORS↗

Design study of an edge current density diagnostic using new high-performance single-channel beam emission spectrometers at DIII-D

A novel Motional Stark Effect spectroscopy system has been designed for application at the DIII-D tokamak. The system is optimized for studies of the poloidal and toroidal magnetic field in the plasma pedestal region with frame rates of up to 10 kHz. Further, light from an existing high-photon-throughput collection lens is analyzed using four single-channel f/2.8 Czerny–Turner spectrometers that use custom-made lens systems instead of mirrors. Each spectrometer has two separate outgoing legs and is operated in a positive grating order, which allows for simultaneous observations of D-alpha and D-beta spectra. Forward modeling using the code FIDASIM shows a radial resolution of the system close to 0.6 cm and sufficiently good spectral resolution when masking the high throughput light collection lens in the horizontal direction to avoid overly strong Doppler broadening of beam emission lines. Moreover, a detailed sensitivity study considering realistic levels of readout and photon noise shows that the poloidal and toroidal magnetic field strengths can be inferred with an uncertainty of less than 1%, which will allow the inference of changes of the plasma current during transient events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Variable voltage electron microscopy: Toward atom-by-atom fabrication in 2D materials

The precisely focused electron beam (e-beam) in scanning transmission electron microscopy has been found to be a versatile tool for patterning matter on the atomic level and enabling atom-by-atom fabrication, however, beam-induced phenomena are known to be extremely sensitive to the e-beam energy and are closely correlated with the proximity of the knock-on threshold. Here we provide a method to control the energy transferred to the sample while facilitating much faster changes in accelerating voltages by maintaining a nearly constant temperature in the electron microscope lenses. We use this method to demonstrate in-situ nano-milling of a graphene film followed rapidly by “gentler” imaging at lower energy. Additionally, the insertion and controlled movement of silicon dopants in graphene is demonstrated by employing a different e-beam energy during each process. We believe the incorporation of variable e-beam energy will broaden the potential for atomic scale e-beam fabrication.

36 MATERIALS SCIENCE↗

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

The Primary Interaction Compton Couple algorithm for sorting GRETINA/GRETA interaction points

The Primary Interaction Compton Couple (PICC) algorithm is presented in this work. The algorithm is used to determine the first-interaction-point position for $γ$-ray events in GRETINA. The first-interaction-point position is crucial for in-beam $γ$-ray spectroscopy experiments with fast beams due to the effect of Doppler broadening on the in-beam energy resolution. The development of the algorithm and its performance compared to a tracking algorithm and the Main Interaction assumption is presented. The PICC algorithm is demonstrated with real data to outperform the $γ$-ray energy tracking algorithm used for comparison here and the Main Interaction assumption in first-interaction-point determinations.

GRETINA↗

Decoding the formation of hammerhead ion populations observed by Parker Solar Probe

Context. In situ observations by the Parker Solar Probe (PSP) have revealed new properties of the proton velocity distributions (VDs), including hammerhead features that suggest a non-isotropic broadening of the beams. Aims. The present work proposes a very plausible explanation for the formation of hammerhead proton populations through the action of a proton firehose-like instability triggered by the proton beam. Methods. We investigated a self-generated firehose-like instability driven by the relative drift of ion populations using a simplified moment-based quasi-linear (QL) theory. While simpler and faster than advanced numerical simulations, this toy model provided rapid insights and concisely highlighted the role of plasma micro-instabilities in relaxing the observed anisotropies of particle VDs in the solar wind and space plasmas. Results. The QL theory proposed here shows that the resulting transverse waves are right-hand polarized and have two consequences on the protons: (i) They reduce the relative drift between the beam and the core, but above all, (ii) they induce a strong perpendicular temperature anisotropy specific to the observed hammerhead ion beam. Moreover, the long-run QL results suggest that these hammerhead distributions are rather transitory states that are still subject to relaxation mechanisms, in which instabilities such as the one discussed here are very likely involved. This foundational work motivates future detailed studies using advanced methods.

Shaaban, Shaaban M. (ORCID:000000030465598X)↗

A Laser Frequency Transverse Modulation Might Compensate for the Spectral Broadening Due to Large Electron Energy Spread in Thomson Sources

Compact laser plasma accelerators generate high-energy electron beams with increasing quality. When used in inverse Compton backscattering, however, the relatively large electron energy spread jeopardizes potential applications requiring small bandwidths. We present here a novel interaction scheme that allows us to compensate for the negative effects of the electron energy spread on the spectrum, by introducing a transverse spatial frequency modulation in the laser pulse. Such a laser chirp, together with a properly dispersed electron beam, can substantially reduce the broadening of the Compton bandwidth due to the electron energy spread. We show theoretical analysis and numerical simulations for hard X-ray Thomson sources based on laser plasma accelerators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Toward monochromated sub-nanometer UEM and femtosecond UED

A preliminary design of a mega-electron-volt (MeV) monochromator with 10 –5 energy spread for ultrafast electron diffraction (UED) and ultrafast electron microscopy (UEM) is presented. Such a narrow energy spread is advantageous in both the single shot mode, where the momentum resolution in diffraction is improved, and the accumulation mode, where shot-to-shot energy jitter is reduced. In the single-shot mode, we numerically optimized the monochromator efficiency up to 13% achieving 1.3 million electrons per pulse. In the accumulation mode, to mitigate the efficiency degradation caused by the shot-to-shot energy jitter, an optimized gun phase yields only a mild reduction of the single-shot efficiency, therefore the number of accumulated electrons nearly proportional to the repetition rate. Inspired by the recent work of Qi et al. (Phys Rev Lett 124:134803, 2020), a novel concept of applying reverse bending magnets to adjust the energy-dependent path length difference has been successfully realized in designing a MeV monochromator to achieve the minimum energy-dependent path length difference between cathode and sample. Thanks to the achromat design, the pulse length of the electron bunches and the energy-dependent timing jitter can be greatly reduced to the 10 fs level. The introduction of such a monochromator provides a major step forward, towards constructing a UEM with sub-nm resolution and a UED with ten-femtosecond temporal resolution. The one-to-one mapping between the electron beam parameter and the diffraction peak broadening enables a real-time nondestructive diagnosis of the beam energy spread and divergence. The tunable electric–magnetic monochromator allows the scanning of the electron beam energy with a 10 –5 precision, enabling online energy matching for the UEM, on-momentum flux maximizing for the UED and real-time energy measuring for energy-loss spectroscopy. A combination of the monochromator and a downstream chicane enables “two-color” double pulses with femtosecond duration and the tunable delay in the range of 10 to 160 fs, which can potentially provide an unprecedented femtosecond time resolution for time resolved UED.

36 MATERIALS SCIENCE↗

Multi-pass cell spectral broadening at high pulse energies

We simulate experimental conditions for nonlinear spectral broadening and compression of multi-joule, sub-picosecond, and femtosecond laser systems focusing on 1 μm center wavelength. The spatial, spectral, and temporal properties of two distinct cases are investigated in detail. The first system is a short multi-pass cell with 0.1–0.5 J pulse energy operated at higher helium pressures, used to illustrate the transition between Kerr-effect induced spectral broadening and spectral broadening in plasma. The second case is a long ten-joule multi-pass cell operated at few Pascal pressure range. These examples cover the operational extent of plasma spectral broadening in a multi-pass cell. Here effects pertaining to plasma spectral broadening, including imperfect spatial beam profiles and initial non-zero nonlinear phase, are investigated, as well as scalability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Edge-Mediated Annihilation of Vacancy Clusters in Monolayer Molybdenum Diselenide (MoSe 2 ) under Electron Beam Irradiation

Here annihilation of vacancy clusters in monolayer molybdenum diselenide (MoSe2) under electron beam irradiation is reported. In situ high-resolution transmission electron microscopy observation reveals that the annihilation is achieved by diffusion of vacancies to the free edge near the vacancy clusters. Monte Carlo simulations confirm that it is energetically favorable for the vacancies to locate at the free edge. By computing the minimum energy path for the annihilation of one vacancy cluster as a case study, it is further shown that electron beam irradiation and pre-stress in the suspended MoSe2 monolayer are necessary for the vacancies to overcome the energy barriers for diffusion. The findings suggest a new mechanism of vacancy healing in 2D materials and broaden the capability of electron beam for defect engineering of 2D materials, a promising way of tuning their properties for engineering applications.

2D materials↗

Overcoming energy limitation in post-compression of picosecond pulses by free beam propagation in air and temporal pulse splitting and recombining

Cryogenically cooled diode-pumped Yb:YAG has been demonstrated to efficiently generate pulses of >1 J energy and several picoseconds duration at a kilohertz repetition rate. Pulse broadening and post-compression techniques capable of operating at these high pulse energies will expand the use of these lasers in applications requiring shorter pulses. Towards this goal, we demonstrate the post-compression of 5.5 ps pulses with energy in the 0.1 J range by spectral broadening of self-collimated large area beams in air. In proof-of-principle experiments, pulses of 65 mJ energy from a cryogenically cooled Yb:YAG laser were compressed to 1.1 ps after 65 m propagation in a compact setup in which the beam was folded using flat mirrors. Further energy scaling was demonstrated by combining this spectral broadening technique with temporal pulse splitting and recombining. 120 mJ pulses were split into two pulses and coherently recombined with 85% efficiency after 50 m of propagation in air to yield 1.4 ps pulses.

High Energy Laser↗