Proton beam position measurement in air using a BPM

A Beam Position Monitor (BPM) is potentially useful to measure the position and phase of the beam in air in a non-destructive way. An air-gap BPM in experiments, such as beam-induced radioactive waste management and dynamic radiography applications, where a so-called air gap is needed, can be utilized to measure the beam position and phase. In this study, a stripline BPM was used in the air-gap of an 800 MeV proton beam transport line. The downstream end of the primary beamline exit window was made of a thin aluminum plate and allowed the beam to travel 1.2 m in ambient air before re-entering into a vacuum drift section. Such a configuration was arranged to examine the BPM effectiveness in atmospheric temperature and pressure where ionization of air occurs. In this study, a high energy (800 MeV), high current (0.6 A beam peak current/pulse) proton beam of 5 mm radius was transported in the air. The beam position relative to the axis was measured by detecting the signature of the beam in a nanosecond scale. This nanosecond scale detection ability was useful to identify other signals such as plasma effects. The BPM signals were processed at a frequency of 201 MHz; thus, one gets a stronger response in a stripline pattern as it was used in this study instead of a dot-type BPM. Experimental data show that the BPM works well in air, but ionization of air or plasma formation could not be measured over the BPM signal. The design, construction, and performance of a BPM in air environment are presented.

43 PARTICLE ACCELERATORS↗

Beam Position Monitor: Sensors, Calibration and Analysis [Slides]

A beam position monitor (BPM) provides information on electron beam current and position, essential to meeting the performance requirements for the Scorpius accelerator as laid down in FR1.1 –FR1.8 and FR2.2. The critical elements in employing BPM’s to meet those requirements are design of the sensor, design of calibration equipment for the sensor, and design of methods to record and process data.

43 PARTICLE ACCELERATORS↗

EIC ESR beam position monitors thermal and thermomechanical study preliminary design

The Electron Ion Collider (EIC) Electron Storage Ring (ESR) Beam Position Monitors (BPM) are designed to monitor the electron beam orbit position on a turn-by-turn and bunch-by-bunch basis in the vacuum chamber. Large variations in ESR fill pattern and bunch intensity imposes a large dynamic range on the BPM system design. And given the large ESR beam current - up to 2.5 A with 1160 x 20 nC bunches – the heating by synchrotron radiation (SR) and beam impedance is a significant concern. The high energy of the electrons – up to 18 GeV – leads to scat tering of the SR that produces high radiation doses and as sociated heating of structures away from the SR impact area. Because of this intense heating, and stringent position stability requirements, an in-depth engineering analysis was carried out. This paper will review the analysis made of the preliminary design and its main outcomes.

43 PARTICLE ACCELERATORS↗

Thermal simulation of the HSR arc BPM Module for EIC

The Electron Ion Collider (EIC) Hadron Storage Ring (HSR) will reuse most of the existing superconducting magnets from the RHIC storage ring. However, the existing stripline beam position monitors (BPM) used for RHIC will not be compatible with the planned EIC hadron beam parameters that include higher intensity, shorter bunches, and some operational scenarios with large radial offsets of the beam in the vacuum chamber. To address these challenges, the existing RHIC stripline BPMs will be shielded, and a new BPM design using button pick-ups and integrated in a new vacuum interconnect/bellows assembly that will be installed adjacent to the existing BPMs. A thermal analysis of the new arc BPM housing and button pick-up design has been conducted to assess the effects caused by beam induced resistive wall heating and signal propagation through the button pick-up cables for several operational scenarios. This report will describe the analysis results to quantify the heat transfer and temperature distribution that can be expected on the new HSR cryogenic arc BPM housings, button pick-ups, and cryo-signal cables.

43 PARTICLE ACCELERATORS↗

Initial PIP-II Beam Current Monitor Fault Case Analyses & Beam Position Monitor Linearity Studies in CST Studio Suite

The use of non-invasive sensors & systems to measure particle beam characteristics is a crucial part of modern accelerator control systems due to their ability to return real time beam data while minimizing negative effects on beam quality. To ensure that one can be reasonably confident these sensors will behave as desired upon be-ing implemented within the beamline, simulations pre-dicting the performance of these sensors under beamline conditions can be used as a valuable tool for checking sensor functionality without a physical test bench. This paper details the design, testing, and results of two sensor models developed using CST Studio Suite soft-ware designed to mimic two sensors to be implemented within the PIP-III beamline: an elliptical, large-aperture beam position monitor (BPM) for which vertical & hori-zontal position signal linearity was analyzed, and an AC current transformer (ACCT) beam current monitor (BCM) used to search for potential fault cases within the BCM and beam pipe flange gaps. Special focus is given to the discovery of linearity variations within the BPM and the use of frequency domain techniques in the BCM fault case analyses.

Rouzky, A. R.↗

PIP-II Beam Current Monitor Fault Case & Beam Position Monitor Linearity Studies in CST Studio

The use of non-invasive sensors & systems to measure particle beam characteristics is a crucial part of modern accelerator control systems. As such, simulations predicting the behavior of these sensors are essential for guiding beamline control system design. This poster details the results returned by two beam sensor models created using CST Studio software: the signal linearity of an elliptical beam position monitor (BPM), and the fault cases of an AC current transformer (ACCT) beam current monitor (BCM).

Rouzky, Adam↗

Design and Development of the PIP-II Stripline Beam Position Monitor

• Designed a stripline Beam Position Monitor (BPM) for the PIP-II accelerator to ensure precise proton beam alignment under ultra-high vacuum (UHV) conditions • Developed a mechanically robust and manufacturable assembly, including a cylindrical housing, electrodes, flange interfaces, and internal supports • Achieved high safety margins under pressure loading, using finite element analysis (FEA), while

Avalos Angel, Alejandro [Northern Illinois U.]↗

LBNL BPM Firmware (CAL-BPM) v1.0

CAL-BPM is the firmware code base of the Advanced Light Source (ALS) Beam Position Monitor (BPM) Field Programmable Gate Array (FPGA) based electronics.

Norum, William↗

Improved Beam Loss Accounting with Fast Data Acquisition (DAQ) Chassis

Identifying the source of beam loss events in the CE-BAF accelerator can be a challenging task. However, with our new prototype system, this task becomes more effi-cient. The system, developed in the fall of 2022, utilizes a dispersive beam position monitor (BPM) and the exist-ing switched electrode electronics BPM hardware. Previ-ously a commercial off-the-shelf data acquisition (DAQ) system was employed to capture BPM wire signals at a sample rate of 20 kS/s. The fast shutdown signal triggered the system, which disables the beam at the injector. Analysis of beam position and energy variation before a beam loss event was used to determine if the beam loss event was associated with an energy transient. The proto-type system, implemented using National Instruments hardware and LabVIEW® software, relied on a software trigger. Manual post-processing was required to ascertain whether the fault was due to an un-tripped cavity with a gradient or phase transient. This work focuses on deploying a Fast DAQ Chassis to monitor BPM hardware in real time and during beam loss events. This system was originally developed and in-stalled in CEBAF to monitor the time-domain RF control signals in the legacy analog RF systems. This technology was leveraged to also monitor BPM signals. As the new system employs a hardware trigger, developing tools to automatically identify faults linked to energy transients unrelated to cavity faults will be straightforward. This paper will discuss the project's initial updates, underlin-ing the crucial role of each member of our team in this achievement

Tiskumara, J.↗

Electron bunch position determination using a high frequency button beam position monitor in the AWAKE facility

The AWAKE facility uses novel proton beam-driven plasma wakefields to accelerate electron bunches over 10m of Rubidium plasma. Precise monitoring of 2 diverse beam types necessitates an electron beam position monitor (BPM) working in a frequency regime of tens of GHz. A high frequency conical button-style BPM with a working regime of up to 40 GHz has been investigated as a way to discriminate the electromagnetic fields of 19 MeV, 4 ps electron bunches propagating spatially and temporally together with a 400 GeV, 170 ps proton bunch in the AWAKE common beamline. The sensitivity of the HF BPM to the electron beam position is determined under various beam conditions, with both electrons and protons, and integration with a TRIUMF front-end is discussed.

43 PARTICLE ACCELERATORS↗

LCLS RF Station Anomaly Candidates, SLAC, Nov 2020 to Dec 2020, Version 1

The data consists of radio-frequency (RF) station process variables (amplitude and amplitude-mean-out-of-tolerance bit) and beam position monitor (BPM) values for about a month of Linac Coherent Light Source (LCLS) time. The data is all from normal conducting hard X-ray operation. The dataset contains roughly 5000 anomaly “candidates.” For each candidate, we include 3.5 minutes of data from the 82 RF stations and ~20 seconds of data from 4 BPMs. We also include several CSV files with additional information and labels for each candidate.

43 PARTICLE ACCELERATORS↗

Diagnostics for PSR Upgrade

This report discusses the diagnostics upgrade plan for the PSR. The PSR diagnostics under discussion include beam position and phase monitor (BPPM), wirescanners, wall current monitors, bunch shape monitors, laser notchers, and diamond array detectors. Existing diagnostics at the PSR include beam position monitors (BPM), a wirescanner, and a wall current monitor. All existing diagnostics need modernization, as part of the PSR upgrade plan. Meanwhile, we will introduce minor changes to improve the existing setups, which will enhance the performance and the longevity of the diagnostics equipment and components in the upgraded PSR operation. On the other hand, new, advanced, and available diagnostic technologies at a high technology readiness level (TRL) can also be considered for implementation for the PSR upgrade. In this note, we go through all types of diagnostics, introducing their basic principle, operating status, and plans for the PSR upgrade.

43 PARTICLE ACCELERATORS↗

Fermilab Booster Beam Emittances from Quadrupole Modes Measured BPMs

The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and requires a lot of tuning to extract out the emittances. In this paper, an improved method where multiple BPMs are used together with better mathematical analysis is described. The BPM derived emittances are then compared with those measured by the Ion Profile Monitor (IPM). Surprisingly, the BPM measured emittances behave very well and are more realistic than those measured by the IPM.

43 PARTICLE ACCELERATORS↗

Beam Tuning Setups for Drift Tube Linacs

Various matching methods for tuning Drift Tube Linacs are overviewed. Special emphasis is on the methods utilizing signature phase scans with single and pairs of Beam Position Monitors (BPM) placed inside or outside of the tuned-up cavity, and that using a combination of phase scans with energy scans.

43 PARTICLE ACCELERATORS↗

LCLS RF Station Phase Anomaly Candidate Dataset

A public anomaly detection dataset constructed from RF station faults for phase at SLAC's LCLS (Linac Coherent Light Source). We have compiled a dataset of the RF station diagnostic phase data and the beam-position monitor (BPM) signals, alongside the hand labels, for a labeled study period. The dataset consists of two HDF5 files (one for train and one for test) containing the raw data, two CSV files containing information about the candidates. The CSV file for the test dataset also contains the label.

Liang, Jia [Stanford Univ., CA (United States). In↗

Fermilab Booster Beam Emittances from Quadrupole Modes Measured by BPMs

The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and requires a lot of tuning to extract out the emittances. In this paper, an improved method where multiple BPMs are used together with better mathematical analysis is described. The BPM derived emittances are then compared with those measured by the Ion Profile Monitor (IPM). Surprisingly, the BPM measured emittances behave very well and are more realistic than those measured by the IPM.

43 PARTICLE ACCELERATORS↗

Measurement of Beam Energy in the Fermilab's Linac taken at the transfer Line

Linac is the first machine in the Accelerator chain at Fermilab where 𝐻− particles are accelerated from 35 keV to 400 MeV and travel to the Booster where they are stripped. of the extra electrons to become protons. The Booster requires stable beam energy at injection. The Linac extraction energy tuning has been performed using two Beam Velocity Monitors (a.k.a Griffin detectors) to maintain stable relative energy between the Booster and the Linac. Our goal is to control the Linac energy parameters using Machine Learning techniques to increase reliability and quality of beam delivered from Linac. The first step is to understand the data from the Linac extraction diagnostics; and develop reliable, accurate methods for energy measurement and control before implementing machine learning. There were two methods of energy measurement implemented, and the results of these are compared. The first method was time of flight measurements using the Phase probes inside B eam Position Monitors (BPM) that provide the beam’s phase of arrival data. The second method used the relation between beam position data from the BPMs and dispersion values from the 400MeV MAD-X model to calculate momentum variation. The results of these two energy measurement methods compare well as the Linac energy is varied.