Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam supply”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Brookhaven National Laboratory electron beam ion source for RHIC

As part of a new heavy ion preinjector that will supply beams for the Relativistic Heavy Ion Collider and the National Aeronautics and Space Administration Space Radiation Laboratory, construction of a new electron beam ion source (EBIS) is now being completed. This source, based on the successful prototype Brookhaven National Laboratory Test EBIS, is designed to produce milliampere level currents of all ion species, with q/m = (1/6)-(1/2). Among the major components of this source are a 5 T, 2-m-long, 204 mm diameter warm bore superconducting solenoid, an electron gun designed to operate at a nominal current of 10 A, and an electron collector designed to dissipate {approx} 300 kW of peak power. Careful attention has been paid to the design of the vacuum system, since a pressure of 10{sup -10} Torr is required in the trap region. The source includes several differential pumping stages, the trap can be baked to 400 C, and there are non-evaporable getter strips in the trap region. Power supplies include a 15 A, 15 kV electron collector power supply, and fast switchable power supplies for most of the 16 electrodes used for varying the trap potential distribution for ion injection, confinement, and extraction. The EBIS source and all EBIS power supplies sit on an isolated platform, which is pulsed up to a maximum of 100 kV during ion extraction. The EBIS is now fully assembled, and operation will be beginning following final vacuum and power supply tests. Details of the EBIS components are presented.

43 PARTICLE ACCELERATORS↗

Deep-learning-based domain adaptation for cavity fault prediction at Jefferson Laboratory

Superconducting radio-frequency (SRF) cavities are the core components of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab, providing high-power electron beams for nuclear physics experiments. The facility comprises 418 SRF cavities, and any fault in these cavities can lead to interruptions in the electron beam supply. Cavity faults are the leading cause of beam trips in CEBAF. Predicting and mitigating those faults before onset can help maintain normal operation. Existing models face challenges in distinguishing between normal and fault signals when changes occur in the underlying time-series data, from changes in control software, operational parameters, or the environment. This work proposes a deep learning domain adaptation model that leverages transfer learning to address fault prediction challenges by improving accuracy. The model is trained and fine-tuned using a dataset collected for faulty and normal operation using a data acquisition system in CEBAF. Our deep learning-based domain adaptation model achieves a prediction accuracy of 89.61% of the fault and normal signals. The developed model effectively predicts normal running signals compared to the baseline approach without domain adaptation. This capacity is essential for the fault prediction task in the CEBAF because of heavily imbalanced data containing vast amounts of normal signals. The model performs well for predicting faults several hundred milliseconds before the fault onset compared to other models where no adaptation is applied. Incorporating deep learning-based domain adaptation techniques will significantly improve the fault prediction performance.

Rahman, Md Monibor [Old Dominion Univ., Norfolk, V↗

SU-E-T-594: Preliminary Active Scanning Results of KHIMA

Purpose: To verify the design criteria on heavy ion beam irradiation, developing a proto type active scanning system was purposed. The active scanning system consists of scanning magnet, power supplies, beam monitors, energy modulation system, and irradiation control system. Methods: Each components of the active scanning system was designed for carbon beam first. For the fast ramping a laminated yoke was purposed. To measure incoming dose and profile, a plate and strip type of ion chambers were designed. Also, ridge filter and range shifter was manufactured. And, the scanning system was modified to adopt 45 MeV of proton beam because of the absence of carbon ion beam in Korea. The system was installed in a beam line at MC-50, KIRAMS. Also, the irradiation control system and planning software was provided. Results: The scanning experiment was performed by drawing KHIMA logo on GaF film. The logo was scanned by 237 scanning points through time normalized intensity modulation. Also, a grid points scanning was performed to measure the scanning resolution and intensity resolution. Conclusion: A prototype active scanning system was successfully designed and manufactured. Also, an initial experiment to print out a drawing on GaF film through the scanning system was completed. More experiments would be required to specify the system performance.

60 APPLIED LIFE SCIENCES↗

R&D for a Soft X-Ray Free Electron Laser Facility

Several recent reports have identified the scientific requirements for a future soft x-ray light source, and a high-repetition-rate free-electron laser (FEL) facility that is responsive to these requirements is now on the horizon. R&D in some critical areas is needed, however, to demonstrate technical performance, thus reducing technical risks and construction costs. Such a facility most likely will be based on a CW superconducting linear accelerator with beam supplied by a high-brightness, high-repetition-rate photocathode electron gun operating in CW mode, and on an array of FELs to which the accelerated beam is distributed, each operating at high repetition rate and with even pulse spacing. Dependent on experimental requirements, the individual FELs can be configured for either self-amplified spontaneous emission (SASE), seeded, or oscillator mode of operation, including the use of high-gain harmonic generation (HGHG), echo-enhanced harmonic generation (EEHG), harmonic cascade, or other configurations. In this White Paper we identify the overall accelerator R&D needs, and highlight the most important pre-construction R&D tasks required to value-engineer the design configuration and deliverables for such a facility. In Section 1.4 we identify the comprehensive R&D ultimately needed. We identify below the highest-priority requirements for understanding machine performance and reduce risk and costs at this pre-conceptual design stage. Details of implementing the required tasks will be the subject of future evaluation. Our highest-priority R&D program is the injector, which must be capable of delivering a beam with bunches up to a nanocoulomb at MHz repetition rate and with normalized emittance {le} 1 mm {center_dot} mrad. This will require integrated accelerating structure, cathode, and laser systems development. Cathode materials will impact the choice of laser technology in wavelength and energy per pulse, as well as vacuum requirements in the accelerating structure. Demonstration experiments in advanced seeding techniques, such as EEHG, and other optical manipulations to enhance the FEL process are required to reduce technical risk in producing temporally coherent and ultrashort x-ray output using optical seed lasers. Success of EEHG in particular would result in reduced development and cost of laser systems and accelerator hardware for seeded FELs. With a 1.5-2.5 GeV linac, FELs could operate in the VUV-soft x-ray range, where the actual beam energy will be determined by undulator technology; for example, to use the lower energy would require the use of advanced designs for which undulator R&D is needed. Significant reductions in both unit costs and accelerator costs resulting from the lower electron beam energy required to achieve lasing at a particular wavelength could be obtained with undulator development. Characterization of the wakefields of the vacuum chambers in narrow-gap undulators will be needed to minimize risk in ability to deliver close to transform limited pulses. CW superconducting RF technology for an FEL facility with short bunches at MHz rate and up to mA average current will require selection of design choices in cavity frequency and geometry, higher order mode suppression and power dissipation, RF power supply and distribution, accelerating gradient, and cryogenics systems. R&D is needed to define a cost and performance optimum. Developments in laser technology are proceeding at rapid pace, and progress in high-power lasers, harmonic generation, and tunable sources will need to be tracked.

43 PARTICLE ACCELERATORS↗

Design Studies for a VUV--Soft X-ray Free-Electron Laser Array

Several recent reports have identified the scientific requirements for a future soft X-ray light source [1, 2, 3, 4, 5], and a high-repetition-rate free-electron laser (FEL) facility responsive to them is being studied at Lawrence Berkeley National Laboratory (LBNL) [6]. The facility is based on a continuous-wave (CW) superconducting linear accelerator with beam supplied by a high-brightness, high-repetition-rate photocathode electron gun operating in CW mode, and on an array of FELs to which the accelerated beam is distributed, each operating at high repetition rate and with even pulse spacing. Dependent on the experimental requirements, the individualFELs may be configured for either self-amplified spontaneous emission (SASE), seeded highgain harmonic generation (HGHG), echo-enabled harmonic generation (EEHG), or oscillator mode of operation, and will produce high peak and average brightness x-rays with a flexible pulse format ranging from sub-femtoseconds to hundreds of femtoseconds. This new light source would serve a broad community of scientists in many areas of research, similar to existing utilization of storage ring based light sources. To reduce technical risks and constructioncosts, accelerator research, development, and design studies at LBNL target the most critical components and systems of the facility. We are developing a high-repetition-rate low-emittance electron gun, high quantum efficiency photocathodes, and have embarked on design and optimization of the electron beam accelerator, FEL switchyard, and array of FELs. We continue our work on precision timing and synchronization systems critical for time-resolved experiments using pump-probe techniques.

43 PARTICLE ACCELERATORS↗

Regularities of femtosecond filamentation in the case of superposition of Gaussian and annular laser beams

The self-action of high-power femtosecond laser beams with a radiation wavelength of 800 nm (formed by superposition of Gaussian and annular beams) in air is theoretically modelled. A detailed analysis of self-focusing and filamentation of this radiation is performed based on the numerical solution of the spectral equation of the unidirectional propagation of a wave packet with allowance for the nonlinearity of the medium, and by tracing averaged diffraction-optical rays. It is shown that, in terms of the diffraction-beam optics, the outer annulus forms a waveguide, which facilitates self-trapping of the central part of the combined beam, supplying the light energy to the filament. The spatial stability of this waveguide depends on the energy stored in the annulus and on the distance from the latter to the beam axis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design study of primary ion provider for RHIC-EBIS

Brookhaven National Laboratory (BNL) has developed the new pre-injector system, Electron Beam Ion Source (EBIS) for Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Design of primary ion provider is an essential problem since it is required to supply beams with different ion species to multiple users simultaneously. The laser ion source with a defocused laser can provide a low charge state and low emittance ion beam, and is a candidate for the primary ion source for RHIC-EBIS. We show a suitable design with appropriate drift length and solenoid, which helps to keep sufficient total charge number with longer pulse length. The whole design of primary ion source, as well as optics arrangement, solid targets configuration and heating about target, is presented.

43 PARTICLE ACCELERATORS↗

Design study of primary ion provider for relativistic heavy ion collider electron beam ion source

Brookhaven National Laboratory has developed the new preinjector system, electron beam ion source (EBIS) for relativistic heavy ion collider (RHIC) and National Aeronautics and Space Administration Space Radiation Laboratory. Design of primary ion provider is an essential problem since it is required to supply beams with different ion species to multiple users simultaneously. The laser ion source with a defocused laser can provide a low charge state and low emittance ion beam, and is a candidate for the primary ion source for RHIC-EBIS. We show a suitable design with appropriate drift length and solenoid, which helps to keep sufficient total charge number with longer pulse length. The whole design of primary ion source, as well as optics arrangement, solid targets configuration and heating about target, is presented.

43 PARTICLE ACCELERATORS↗

Desorption characteristics of selenium and tellurium thin films

The temperature-dependent desorption behavior of selenium and tellurium is investigated using a heated quartz crystal microbalance. Prior to heating the quartz crystal microbalance, selenium and tellurium films with varying thickness were deposited using thermal effusion cells in a molecular beam epitaxy system for subsequent determination of temperature-dependent mass loss of the deposited films. The desorption rate for tellurium was found to exhibit one sharp peak around 190°C, indicating the loss of the entire film irrespective of film thickness within a temperature window of 20°C, which was completely evaporated at 200°C. Similar experiments for selenium revealed that the thermal desorption took place via a two-stage process with a smaller portion of the material desorbing within an even narrower temperature window of 5°C at a much lower peak temperature of 65°C, while most selenium desorbed within a temperature range of 10°C around 90°C. This two-stage behavior indicated the presence of at least two chemically distinct selenium species or binding states. The direct and quantitative determination of the chalcogen desorption process provides important insights into the kinetics of chalcogenide-based film growth and is in addition of applied benefit to the research community in the area of Se/Te capping and decapping of air sensitive materials as it provides temperature ranges and rates at which full desorption is achieved. Our work furthermore points toward the need for a more detailed understanding of the chemical composition state of atomic and molecular beams supplied from thermal evaporation sources during growth.

36 MATERIALS SCIENCE↗

Stability theory of Knudsen plasma diodes

A stability theory is developed for a plasma diode in which an electron beam supplied from the emitter propagates without collisions in the self-consistent electric field against the immobile ion background. An integral equation for the amplitude of the perturbed field is deduced using the Q,G method for the regime without electron reflection from a potential barrier. Analytic solutions to this equation are obtained for a number of important particular cases, and the plasma dispersion properties are examined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High yield neutron generators using the DD reaction

A product line of high yield neutron generators has been developed at Adelphi technology inc. The generators use the D-D fusion reaction and are driven by an ion beam supplied by a microwave ion source. Yields of up to 5 Multiplication-Sign 10{sup 9} n/s have been achieved, which are comparable to those obtained using the more efficient D-T reaction. The microwave-driven plasma uses the electron cyclotron resonance (ECR) to produce a high plasma density for high current and high atomic ion species. These generators have an actively pumped vacuum system that allows operation at reduced pressure in the target chamber, increasing the overall system reliability. Since no radioactive tritium is used, the generators can be easily serviced, and components can be easily replaced, providing essentially an unlimited lifetime. Fast neutron source size can be adjusted by selecting the aperture and target geometries according to customer specifications. Pulsed and continuous operation has been demonstrated. Minimum pulse lengths of 50 {mu}s have been achieved. Since the generators are easily serviceable, they offer a long lifetime neutron generator for laboratories and commercial systems requiring continuous operation. Several of the generators have been enclosed in radiation shielding/moderator structures designed for customer specifications. These generators have been proven to be useful for prompt gamma neutron activation analysis (PGNAA), neutron activation analysis (NAA) and fast neutron radiography. Thus these generators make excellent fast, epithermal and thermal neutron sources for laboratories and industrial applications that require neutrons with safe operation, small footprint, low cost and small regulatory burden.

43 PARTICLE ACCELERATORS↗

Record of Decision: H - LEBT Design Modifications

The LAMP Conceptual Design (LCD) is described in the LAMP Conceptual Design Report. The proposed new configuration of the LAMP H - LEBT encompasses multiple changes to the LCD. The new configuration makes use of a single H - source to supply beam to all LANSCE user stations except IPF; this eliminates one of the H - sources in the LCD, and the associated pulsed merger magnet the use of two such sources required. The source current from the sole H - source is gated on a macropulse-by-macropulse basis using techniques demonstrated at SNS (Spallation Neutron Source), specifically, changes to the RF plasma drive power. A pulsed electrode system is used to match the beam into the LEBT transport line, variable on a macropulse-by-macropulse basis to match the source beam current.

43 PARTICLE ACCELERATORS↗

B.Gregory Lecture

Third series of "Gregory lectures" on the memory of B. Gregory (1919-1977), DG from 1965 to 1970. The first conference B. Gregory is presented by Professor V. Weisskopf, his predecessor. Chriss Greeg from Berkeley also speaks.

beam↗

Iron beam acceleration using direct plasma injection scheme

A new set of vanes of radio frequency quadrupole (RFQ) accelerator was commissioned using highly charged iron beam. To supply high intensity heavy ion beams to the RFQ, direct plasma injection scheme (DPIS) with a confinement solenoid was adopted. One of the difficulties to utilize the combination of DPIS and a solenoid field is a complexity of electro magnetic field at the beam extraction region, since biasing high static electric field for ion extraction, RFQ focusing field, and the solenoid magnetic field fill the same space simultaneously. To mitigate the complexity, a newly designed magnetic field clamps were used. The intense iron beam was observed with bunched structure and the total accelerated current reached 2.5 nC.

43 PARTICLE ACCELERATORS↗

New High Power Test Facility for VHF Power Amplifiers at LANSCE

A new test facility was designed and constructed at Los Alamos Neutron Science Center (LANSCE) for testing the Thales TH628 Diacrode{sup R} and TH781 tetrode power amplifiers. Anode power requirements for the TH628 are 28 kV DC, with peak currents of 190 Amperes in long pulses. A charging power supply was obtained by reconfiguring a 2 MW beam power supply remaining from another project. A traditional ignitron crowbar was designed to rapidly discharge the 88 kJ stored energy. The anode power supply was extensively tested using a pulsed tetrode switch and resistor load. A new Fast Protect and Monitor System (FPMS) was designed to take samples of RF reflected power, anode HV, and various tube currents, with outputs to quench the HV charging supply, remove RF drive and disable the conduction bias pulse to the grid of each tube during fault events. The entire test stand is controlled with a programmable logic controller (PLC), for normal startup sequencing and timing, protection against loss of cooling, and provision for operator GUI.

Accelerator Design, Technology, and Operations↗

SU-E-T-532: Validation and Implementation of Model-Based Patient Specific Quality Assurance Using Mobius3D and MobiusFX in a Clinical Setting

Purpose: This work carries out the commissioning and validation of the Mobius3D and MobiusFX software tools, which can replace the time-consuming measurement-based patient specific quality assurance (PSQA). Methods: The beam model supplied by Mobius3D was validated against a 21EX linac's beam measured data. Complex patient (VMAT) plans using Eclipse treatment planning system (TPS) was used to test the consistency between Mobius3D (calculates dose using patient image and field data) and MobiusFx (calculates dose using treatment dynalog files). Dose difference and gamma analysis (3%/3mm) between Mobius3D and MobiusFx were used to assess treatment plan and treatment delivery consistency. An end-to-end test was performed to validate Mobius3D and MobiusFx against ion chamber measurements. Effect of the dosimetric leaf gap (DLG) on Mobius3D dose calculation was additionally investigated. Results: Mobius3D beam model parameters matched within 1%-3% with our beam measured data. A comparison of Mobius3D and MobiusFx dose matrices for VMAT planned prostate cases showed (0.33±0.07)% mean dose difference with gamma values above 95%. The end-to-end test showed dose differences of 1% between Mobius3D and MobiusFx. Dependence of Mobius3D dose calculation upon DLG was explored by introducing a ±0.5 mm change in the default value for DLG. This change resulted in agreement differences above 2% Conclusion: Use of reference beam data would appear to speed up commissioning process for the clinical implementation of Mobius3D. However, careful consideration is required when comparing the information provided by the software, since large dose variations can be seen when the proper parameters are not optimized. The plan and delivered dose were in good agreement; hence MobiusFx has the potential to significantly speed up the PSQA process and at the same time helps to verify treatment parameters that are not possible with measurement-based PSQA.

60 APPLIED LIFE SCIENCES↗

Short Circuit Detection and Voltage Sense for High Voltage Ionization Tube Power Supplies

Fermilab's PIP-II upgrade requires new rack-mounted power supplies for Beam Loss Monitor (BLM) ionization tubes compatible with the microTCA 4.1 standard, supporting high-side current measurement for short circuit detection, voltage sense telemetry, and low-side current measurement for beam loss readout. This work presents the design and preliminary schematic of such a supply. A resistive current sensing approach was chosen over inductive, optical, and Hall-effect alternatives for its independence from cable length and component availability. A 500 mΩ inline shunt steps the 2 kV common mode voltage down to roughly 70 V, producing a ~27 μV pulse during a short, which is amplified 500x, compared against a 14-bit DAC threshold, and latched to drive a fault line. Voltage sense steps the 2 kV output down at a 1V/1000V ratio, buffers it with a low bias current amplifier, and digitizes it via a 24-bit ADC over SPI. Onboard power is regulated from 12 V down to isolated 5 V and 3.3 V rails, with capacitive isolation on FPGA communication lines. Lumped parameter models were developed for the ionization tube (0.327 nF, 20 to 200 GΩ dynamic resistance) and the RG-58 coaxial cable to support the design. Component selection is complete and a preliminary schematic has been drawn in Altium Designer, forming the foundation for future prototyping and validation.

Yu, Kellen [Cornell U.]↗

Shielding calculations for the upgrade of the HFIR HB 2 beam line

Experimental facilities at the Oak Ridge National Laboratory's High Flux Isotope Reactor are being upgraded through the redesign of beam tubes supplying neutrons to those facilities. In support of the shield design for one of the beam lines HB-2, calculations were performed to determine dose rates outside the shielding as well as background radiation levels at various locations around the instrumentation. Low-power (10 % power) as well as full-power measurements were made at key locations, and calculated results were compared with corresponding measured results. This paper describes the calculations and compares the measured and calculated results. Most of the measured results, when normalized to the full-operating-power level, compared favorably with the calculated results. One differed by a factor of 2.5, and another differed by a factor of 6. Based on this agreement, one can infer that reasonable calculations for some three-dimensional shield designs can be performed using two-dimensional methods and two-dimensional approximations to the three-dimensional geometry. The results confirmed the adequacy of the design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗