Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Neutral Atomic Beam Techniques for Diagnosis of Edge and Scrape-Off Layer Plasmas (2017-2019) [and subsequently titled] Neutral Atomic Beam Techniques for Diagnosis of Interior and Scrape-Off Layer Plasmas (2019-2022) (Final Report)

This is the Final Technical Report for the DOE Measurement Innovation grant DE-SC0017998 titled Neutral Atomic Beam Techniques for Diagnosis of Edge and Scrape-Off Layer Plasmas (2017-2019) and subsequently titled Neutral Atomic Beam Techniques for Diagnosis of Interior and Scrape-Off Layer Plasmas (2019-2022). The grant was funded by the Office of Fusion Energy Sciences (FES) for the period 1 September 2017 – 31 May 2022. Work performed through the grant has resulted in diagnostic innovations and new measurement capabilities that could improve understanding of magnetic equilibrium, edge localized modes in tokamaks, and bootstrap and Pfirsch-Schlüter currents in stellarators. We have performed simulations of a novel non-hydrogen beam-based diagnostic that would determine a local value (in the plasma) of the poloidal flux function by measuring the toroidal angle of the beam particles' velocity at a detector external to the plasma. The approach is similar to that of a Heavy Ion Beam Probe (HIBP), but would be able to operate with a smaller, more economical detection systems and, in doing so, may enable substantial extension of scenarios in which beam-based diagnostics are deployed. Key results include: Identification of the neutral and singly charged atoms that are most appropriate for use in the beam based diagnostic and the ionization cross-sections that are important for studying the plasma edge of a large device; Development of a promising geometry for operation in which the beam is injected horizontally near the torus midplane; Implementation of simulations using banana orbit trajectories of secondary beam ions to access plasma regions that are commonly in-accessible to an HIBP diagnostic, including sample volumes near the X-point of a diverted tokamak; Assessment of the ability of the diagnostic concept (originally developed under the assumption of, and reliant on, symmetry) to work in stellarators by performing simulations with both quasi-symmetric fields and non-quasi-symmetric fields; Measurement of noise levels with a prototype detector on a stellarator and exploration of techniques to minimize effects of noise on a diagnostic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The influence of the field setup on the dosimetry of abutted fields in single-isocenter half-beam techniques

Purpose: To study the influence of the field setup on the dosimetry at the junction in single-isocenter half-beam techniques. Methods: The dosimetry at the junction for a two-field setup with the gantry at zero was first evaluated with radiochromic films. A three-field setup, with an anterior field and two opposed lateral fields, was also analyzed for two different relative positions of the fields involved. In all cases, the dose increase at the central axis, called the junction dose, was measured. Results: Junction doses varied greatly with the setup. For the three-field setup, the junction dose differed from that obtained with the two-field setup, and it greatly depended on the relative position of the fields. When the anterior field was closer to the gantry than the lateral fields, a field gap occurred and the junction dose was negative. When the anterior field was farther from the gantry than the lateral fields, a field overlap was obtained and the junction dose was positive. The difference in the junction dose between the three-field setups was around 18% for the three accelerators evaluated. Conclusions: Having a uniform dose distribution for two fields at gantry 0 deg. does not guarantee a uniform distribution at other gantry angles. Junction doses are largely affected by the relative position of the radiation fields, which may have an impact in clinical practice. Therefore, any method aiming to assess or to optimize the dose homogeneity at the junction should take this effect into account.

60 APPLIED LIFE SCIENCES↗

Some interesting aspects of physisorption stay-time measurements obtained using molecular-beam techniques

Stay-time distributions have been obtained for Xe physisorbing on polycrystalline nickel as a function of the target temperature using a pulsed molecular-beam technique. Some interesting effects due to ion bombardment of the surface using He, Ar, and Xe ions are presented. Measured detector signal shapes are found to deviate from those predicted for first-order desorption with velocities corresponding to Maxwellian effusion at the surface temperature. Evidence is found for interaction between beam pulse adsorption and steady-state adsorption of beam species background atoms.

Wilmoth, R. G.↗

Crossed-beam technique for measuring horizontal winds

Three ground-based single-beam detectors determine wind vectors present within a given volume. Winds approximately constant near a selected height, blowing into or out of a 90 degree arc can be calculated with reasonably small error.

Heybey, W. H.↗

A feasibility study of using advanced external beam techniques to create a vaginal cuff brachytherapy-like endometrial boost plan

The purpose of this study was to explore the feasibility of using advanced external beam radiation therapy (EBRT) planning techniques for creating plans that could be used as a possible alternative for high-dose rate (HDR) vaginal cuff brachytherapy (VCBT) boost in treating endometrial cancer. The computed tomography (CT) images of a total of 4 female patients who had endometrial cancer treated with HDR-VCBT were selected for this study. A typical HDR-VCBT target volume, 0.5-cm-thick shell volume around the cylinder applicator in the prescribed treatment length was contoured and used as the planning target volume (PTV) in both the HDR VCBT and the EBRT VCBT-like plans. HDR-VCBT plans were made based on the clinical protocol, 6 Gy given at the cylinder surface. The EBRT plans were generated using either a 7-field intensity-modulated radiation therapy (IMRT) or a 2-arc volumetric-modulated arc therapy (VMAT) techniques for different cylinder sizes and treatment lengths, with the prescription dose of 5 Gy. Organs at risk (OARs) such as bladder, femoral heads, rectum, and sigmoid were also contoured and used in dosimetric evaluations. Dose-to-target metrics included mean dose, the dose covering 90% of target volume (D90) and the percentage of target volume covered by 90% of prescription dose (V90 or V13.5 Gy). Dose to OAR metrics included the maximum dose received by 0.1 cc (D0.1cc), 1.0 cc (D1.0cc), and 2.0 cc (D2.0cc) of OARs. These metrics were calculated and compared between all techniques. After the EBRT plans were normalized to achieve a comparable mean dose to target as HDR-VCBT, the EBRT plans were found to have superior target coverage and increased dose homogeneity compared with HDR-VCBT. V90s of EBRT plans were 95%, compared with 50% to 58% of the HDR plans. However, D0.1cc, D1.0cc, and D2.0cc of OARs were 2% to 38% lower in HDR-VCBT than in EBRT. Although HDR-VCBT plans demonstrated superior normal tissue sparing, both EBRT and HDR-VCBT plans produce plans that met clinical dose constraints on normal tissues. Advanced EBRT techniques such as IMRT and VMAT are capable of making plans, which closely resemble HDR-VCBT. Although the doses of OARs are greater in EBRT than in HDR-VCBT, the prescription dose coverage and dose homogeneity of the EBRT plans are greater than that of HDR-VCBT plans at the similar mean dose, and the OAR dose is still acceptable with EBRT plans. The detailed dosimetric approaches are provided in the study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Precise measurement of single carbon nanocoils using focused ion beam technique

We have developed a precise resistivity measurement system for quasi-one-dimensional nanomaterials using a focused ion beam. The system enables the resistivity of carbon nanocoils (CNCs) to be measured and its dependence on coil geometry to be elucidated. At room temperature, the resistivity of CNCs tended to increase with coil diameter, while that of artificially graphitized CNCs remained constant. These contrasting behaviors indicate coil-diameter-induced enhancement in structural disorder internal to CNCs. Low-temperature resistivity measurements performed on the CNCs revealed that electron transport through the helical axis is governed by the variable range hopping mechanism. The characteristic temperature in variable range hopping theory was found to systematically increase with coil diameter, which supports our theory that the population of sp{sup 2}-domains in CNCs decreases considerably with coil diameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A method for accurate zero calibration of asymmetric jaws in single-isocenter half-beam techniques

Purpose: To present a practical method for calibrating the zero position of asymmetric jaws that provides higher accuracy at the central axis and improves dose homogeneity in the abutting region of half-beams. Methods: Junction doses were measured for each asymmetric jaw using the double-exposure technique and electronic portal imaging devices. The junction dose was determined as a function of jaw position. The shift in the zero jaw position (or in its corresponding potentiometer readout) required to correct for the measured junction dose could thus be obtained. The jaw calibration was then modified to introduce the calculated shift and therefore achieve an accurate zero position in order to provide a relative junction dose that was as close to zero as possible. Results: All the asymmetric jaws from four medical linear accelerators were calibrated with the new calibration procedure. Measured relative junction doses at gantry 0 Degree-Sign were reduced from a maximum of {+-}40% to a maximum of {+-}8% for all the jaws in the four considered accelerators. These results were valid for 6 MV and 18 MV photon beams and for any combination of asymmetric jaws set to zero. The calibration was stable over a long period of time; therefore, the need for recalibrating is seldom necessary. Conclusions: Accurate calibration of the zero position of the jaws is feasible in current medical linear accelerators. The proposed procedure is fast and it improves dose homogeneity at the junction of half-beams, thus, allowing a more accurate and safer use of these techniques.

07 ISOTOPE AND RADIATION SOURCES↗

Uniform Beam Simulation Technique for Beam Scans and Machine Learning Studies at Fermilab

Fermilab's neutrino facilities, including NuMI and the upcoming LBNF, use proton beams to produce positively and negatively charged pions and kaons. Detailed simulations are necessary to study particle interactions and beam propagation. To efficiently analyze beam scan effects, we propose a technique to generate multiple simulation samples with high statistics. These samples can be used to develop beamline simulation based machine learning applications. In this technique, we generate a uniformly distributed single simulation data sample. We calculate Gaussian weights for each beam configurations and apply them to post-processing measurements. In this poster, we demonstrate the proposed simulation technique. This technique reduces simulation time and computing resources significantly.

Wickremasinghe, Athula↗