Probing Thermal Transport in Fluidized Bed Using Modulated Photothermal Radiometry

Abstract In concentrated solar power (CSP) applications, fluidized bed is a promising approach for high heat transfer coefficient (HTC) solar receivers and heat exchangers. However, the complexity of multiphase mixing has made it difficult to characterize and analyze the heat transfer mechanism. This paper presents an experimental study on simultaneously characterizing heat transfer in both the near-wall and the bulk regions of a fluidized bed using modulated photothermal radiometry (MPR). The MPR is a non-contact frequency-domain technique using an intensity-modulated laser as the heat source and surface infrared emission as thermometry. The thermal penetration depth of the laser heating is varied by controlling its modulation frequency, and thus the measurement can resolve the near-wall and the bulk thermal resistances. With the MPR technique, we measured fluidized silica sands with a mean size of 164 μm in a vertical channel of 6 mm depth. Our results show that the near-wall thermal resistance is substantially increased with increasing gas velocity, which partially offsets the benefit of higher HTC brought by stronger particle mixing during the fluidization. We also used the MPR to quantify the improvement in particle-wall heat transfer in an inclined channel. We found that an 8° inclination towards the heat exchanging side led to a lower near-wall thermal resistance and a higher HTC at high gas velocities. This work demonstrates that the MPR technique is a useful tool to quantify the important near-wall thermal resistance from a bulk particle bed, which not only advances our understanding of heat transfer in fluidized beds, but may also contribute to the design of fluidized bed heat exchangers with higher HTC.

14 SOLAR ENERGY↗

Hardware-in-the-Loop Test Bed and Test Methodology for Microgrid Controller Evaluation

Increasing penetration levels of distributed energy resources are making the deployment of microgrids more feasible. Controllers that operate such microgrids are key to realizing the objectives of the microgrid owner or operator and there is a need to evaluate microgrid controller performance prior to field deployment. This paper describes a controller hardware-in-the-loop and power hardware-in-the-loop microgrid controller test bed that was designed and constructed to evaluate the capabilities of a microgrid controller for a proposed campus microgrid. This paper also presents a test methodology to evaluate microgrid controller functionality, and it describes how the controller was assessed through the application of different test scenarios. Results from the testing are presented to provide insight into the capabilities of the test bed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensitivity Analysis of Particle-In-Cell Modeling Parameters in Settling Bed, Bubbling Fluidized Bed and Circulating Fluidized Bed

The objective of the work presented is to perform a preliminary sensitivity analysis of particle-in-cell (PIC) model parameters when applied to settling bed, bubbling fluidized bed, and circulating fluidized bed simulations. These examples correspond to widely different flow conditions commonly seen in chemical engineering applications. Simulations were performed using the PIC method in the open-source software Multiphase Flow with Interphase eXchanges (MFiX) developed by the National Energy Technology Laboratory (NETL). As part of the non-intrusive uncertainty quantification (UQ) analysis, simulation campaigns were generated using Nodeworks. Sampling locations or settings for PIC model parameters were determined using the Latin Hypercube method. Response surfaces were created using radial basis functions (RBF), and Sobol’ indices were estimated to quantify the influence of model parameters on the quantities of interest (QoI). This study marks a first step towards systematically determining optimal ranges for model parameters used in MFiX-PIC. Based on limited experience, it is expected that these values would depend strongly on flow conditions. Given the complexity of the multiphase flow systems under analysis, a non-intrusive UQ based approach is used to identify the most influential parameters in each case. This prior knowledge will help in proposing an effective design of experiments (DoE) and determine optimal parameters through techniques such as deterministic or Bayesian calibration, which will be pursued in the future.

42 ENGINEERING↗

Enriched hydrogen production over air and air-steam fluidized bed gasification in a bubbling fluidized bed reactor with CaO: Effects of biomass and bed material catalyst

Gasification is one of the methods of generating biopower or biofuels from biomass waste. In this study, a benchscale fluidized bed reactor was used for biomass air and air-steam gasification. Gasification was performed under constant operating conditions (~780 °C, equivalence ratio = ~0.32) to investigate the effect of biomass (switchgrass, pine residues) and bed materials (sand, CaO+ sand, Al 2 O 3 , and CaO + Al 2 O 3 ). All gasification products, such as synthesis gas (syngas), contaminant gases, tar, and biochar (solid) were comprehensively analyzed. The composition of biomass significantly impacted CO and H 2 yield from volatile combustible matter and fixed carbon. Further, the presence of CaO made the condition favorable for the water-gas shift (WGS) reaction combined with the CO 2 carbonation reaction, which increased H 2 concentration. Additional steam with CaO increased H 2 concentration closer to 50% (N 2 free condition) through the combination reactions of steam hydrocarbon reforming and WGS by producing 44 g H 2 /kg dry biomass and 143 g CO /kg dry biomass . The usage of steam reduced the overall yield of contaminant gases, whereas the usage of CaO or Al 2 O 3 decreased the amount of gasification tar by approximately 5.8–6.5 g tar /kg dry biomass . In conclusion, this study can provide valuable experimental data for biomass waste to produce better quality syngas.

08 HYDROGEN↗

Acoustic Monitor for Particle Size and Bed Friction in a Carbonate Fluidized Bed at High Temperature - 18014

Previous work has shown that acoustic spectra of fluidized bed pressure fluctuations show many useful bed properties [1-3]. This current work further explores the use of acoustic monitors for an 18' diameter, 66-74'' height fluidized bed at >640 deg. C. This process denitrates and agglomerates an injected sodium/aluminum nitrate aqueous simulant and produces at steady-state a denitrated product of 200-300 micron sodium carbonate/aluminate particles. The fluidized bed shows characteristic acoustic resonances around 1-2 Hz in the FFT (Fast Fourier Transform) of pressure fluctuations for each of three taps at fluidized bed heights of 12'', 39'', and 58''. The acoustic resonance spectra depend on a bed friction that once calibrated, monitors the HMPD (harmonic mass mean particle diameter or Sauter mean diameter) along with other important bed properties. This fluidized bed operates at high temperature with an evolving HMPD that can be steady state with an appropriate superficial spatial velocity (SSV). The acoustic FFT integrated power spectrum, IPS, of pressure fluctuations represents the bed-friction damped RMS (root mean square) pressure fluctuations at each tap. The transition from a static to fluidized bed at each bed height occurs when the damped bed RMS pressure fluctuations are greater than the static head (the FFT zero Hz designated zero Hz proportional to FFT zero Hz) at that bed height. A bed will de-fluidize and become static at a bed height when bed friction completely dampens the RMS pressure fluctuations, which occurs for decreasing particle size among other factors. The ratio IPS/zero Hz then provides a continuous monitor of bed friction damping as well as particle size as the HMPD. Since HMPD and bed friction damping are both very important parameters for fluidized particle beds, the acoustic HMPD and bed friction damping both provide very useful monitors for fluidized bed operation. Such acoustic monitors have shown that they are especially sensitive to the presence of very fine particles in the bed of less than 50 microns diameter. Acoustic monitors for particle size and bed friction damping will be very useful in any fluidized bed, especially fluidized beds where particle size changes. The fluidized bed friction damping depends on many other bed properties besides particle size such as bed height, density, SSV, void fraction, gas viscosity, and fluidization scheme and so acoustic bed friction should also be useful for monitoring other bed properties besides particle size. In fact, the change in the static bed friction slope with SSV upon fluidization follows the Ergun function and reveals a minimum fluidization velocity for each HMPD. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal enhancement cartridge heater modified (TECH Mod) tritium hydride bed development, Part 1 - Design and fabrication

The Savannah River Site (SRS) tritium facilities have used first generation (Gen1) LaNi{sub 4.25}Al{sub 0.75} (LANA0.75) metal hydride storage beds for tritium absorption, storage, and desorption. The Gen1 design utilizes hot and cold nitrogen supplies to thermally cycle these beds. Second and third generation (Gen2 and Gen3) storage bed designs include heat conducting foam and divider plates to spatially fix the hydride within the bed. For thermal cycling, the Gen2 and Gen3 beds utilize internal electric heaters and glovebox atmosphere flow over the bed inside the bed external jacket for cooling. The currently installed Gen1 beds require replacement due to tritium aging effects on the LANA0.75 material, and cannot be replaced with Gen2 or Gen3 beds due to different designs of these beds. At the end of service life, Gen1 bed desorption efficiencies are limited by the upper temperature of hot nitrogen supply. To increase end-of-life desorption efficiency, the Gen1 bed design was modified, and a Thermal Enhancement Cartridge Heater Modified (TECH Mod) bed was developed. Internal electric cartridge heaters in the new design to improve end-of-life desorption, and also permit in-bed tritium accountability (IBA) calibration measurements to be made without the use of process tritium. Additional enhancements implemented into the TECH Mod design are also discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Corrosion properties of powder bed fusion additively manufactured 17-4 PH stainless steel

The corrosion susceptibility of a laser powder bed fusion (LPBF) additively manufactured alloy, UNS S17400 (17-4 PH), was explored compared to conventional wrought material. Microstructural characteristics were characterized and related to corrosion behavior in quiescent, aqueous 0.6 M NaCl solutions. Electrochemical measurements demonstrated that the LPBF 17-4 PH alloy exhibited a reduced passivity range and active corrosion compared to its conventional wrought counterpart. Lastly, a micro-electrochemical cell was employed to further understand the effects of the local scale and attributed the reduced corrosion resistance of the LPBF material to pores with diameters ≥ 50 µm.

36 MATERIALS SCIENCE↗

Hexagonal boron nitride catalyst in a fixed-bed reactor for exothermic propane oxidation dehydrogenation

Hexagonal boron nitride (h-BN) with high thermal conductivity is potentially an effective catalyst for highly exothermic propane oxidative dehydrogenation (ODH) reaction. Here, we report our experimental and theoretic studies of such a catalyst for propane ODH in a fixed-bed reactor. Based on the computational fluid dynamics calculation (CFD) results, the catalyst bed temperature increases by less than 1 degrees C in the h-BN catalyst bed which is much smaller than that (8 degrees C) in the VOx/gamma-Al2O3 catalyst bed at a similar propane conversion (25%) using a micro-tubular reactor with a diameter of 6 mm. Even in an industrially relevant reactor with an inner diameter of 60 mm, a uniform temperature profile can still be maintained using the h-BN catalyst bed due to its excellent thermal conductivity as opposed to a temperature gradient of 47 degrees C in the VOx/gamma-Al2O3 catalyst bed. The results reported here provide useful information for potential application of h-BN catalyst in propane ODH. (C) 2018 Elsevier Ltd. All rights reserved.

Tian, jinshu↗

Modeling and Analysis of Coupled Flow Through Packed Beds as a Diagnostic Tool for Packed Bed Reactor Health - 17172

The US Department of Energy, Office of River Protection, is building the Waste Treatment and Immobilization Plant (WTP) in Richland, Washington, to immobilize the hundreds of millions of liters of radioactive waste stored at the Hanford Site in Washington state. The offgas generated during vitrification of these wastes requires treatment to remove and/or destroy chemical and radioactive hazardous components before release to the atmosphere. In particular, volatile and semi-volatile hydrocarbon components are to be catalytically oxidized to carbon dioxide and water, whereas nitrogen oxides (NOx) are to be catalytically reduced to nitrogen and water. These tasks are accomplished in a series of packed bed reactors. Achieving the requisite Destruction/Removal Efficiency (DRE) for each of the tracked components is highly dependent on the flow characteristics of the offgas through the packed beds. The flow kinetics may be monitored and characterized during the initial warm-up of the system. The gases, initially at 76 deg. C (169 deg. F), (a) flow through one side of a countercurrent heat exchanger to recover heat from the exiting gases (which have already passed through the catalytic beds), (b) are then further heated electrically to approximately 400 deg. C (750 deg. F; the preferred operating temperature of the Thermo Catalytic Oxidizer (TCO)), (c) pass through the TCO where the reduced components of the offgas are oxidized over a supported Pt catalyst bed, (d) are partially cooled to approximately 315 deg. C (600 deg. F) by addition of approximately 25% (by weight) diluted ammonia/air mixture, (e) pass through the Selective Catalytic Reducer (SCR) where the NOx components are converted to N{sub 2} and H{sub 2}O over a supported V2O{sub 5}/TiO{sub 2} catalyst bed, and (f) exit through the hot side of the countercurrent heat exchanger. The electrical heater is not powerful enough to raise the temperature of the offgas to the desired 400 deg. C without the contribution of the heat recovered in the heat exchanger. Moreover, the thermal mass of the beds and housings of the TCO and SCR require a significant input of thermal energy to reach the desired operating temperatures; the better part of a day is required to bring the unit from ambient temperatures to operating temperatures. Therefore, the temperature of the stream during the initial warm-up of the system at each point in the system is dependent upon the thermal mass, flow dispersion, and permeability of the components, quantified as characteristic/representative volumes and residence times. By monitoring the temperature of the offgas as it enters and exits each portion of the system during this warm-up period one may model the system as a series of small Continuously Stirred Tank Reactors (CSTR)s (referred to as 'CSTRlets') to explain the flow kinetics through the catalyst beds. These component CSTRlets are adjustable in size and number, that one may model the flow profile of the gases through the catalyst beds. For example, a single large CSTR will present an effluent temperature profile with a simple exponential decay shape. Concatenating more CSTRlets generate more complex sigmoidal responses. Concatenating one CSTRlet significantly larger than the others in the train also alters the shape of the effluent temperature profile, in a fashion not replicable by a train of equal-sized CSTRlets. The ultimate goal is to accurately emulate the entire system as a representative CSTRlet train. Once accomplished, this characterization may be used in subsequent warm-ups (following shutdown for catalyst maintenance, for example) or by an intentional step change in inlet offgas temperature to detect/diagnose anomalies in flow through the beds (e.g., channeling or partial blockage.) This work presents development of this model through analytical, calculational, and empirical means. - The analytic model is accomplished by Laplace transform analysis of each component to recover component process transfer functions. - The calculational portion is performed via brute force finite element calculation. - Fitting empirical data from the warm-up of the TCO skid allows one to select the hypothetical CSTRlet trains which best fit the TCO and SCR beds for the analytical and finite element calculations. The first portion of this paper presents the development of the analytical (Laplace space) model of the coupled system. Estimated values for the initial temperature, mass, specific heat, electrical heat, and relative quantities of the offgas, catalyst beds, stainless steel housings, and ammonia dilution stream are used to generate expected temperature profiles at several selected junctures of the system. The number and size of the component hypothetical CSTRlets are calculated from the analytical model and are used to predict temperature profiles at the exit of the system and at intermediate junctions between system components (where thermocouples are present in the actual unit.) The finite element calculations employ a series of CSTRlet volumes to produce a similar suite of temperature profiles, for comparison with the analytical model results. Finally, empirical data from the Factory Acceptance Test system warm-up are used to select and compare the results from each modeling strategy to select the CSTRlet train(s) which best model the behavior of the actual system. This work presents a novel method of system component characterization, of value to the WTP plant and similar vitrification facilities as well as chemical process industries unrelated to waste management. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using atomic layer deposited tungsten to increase thermal conductivity of a packed bed

This study investigated the effective thermal conductivity (k{sub eff}) of packed-beds that contained porous particles with nanoscale tungsten (W) films of different thicknesses formed by atomic layer deposition (ALD). A continuous film on the particles is vital towards increasing k{sub eff} of the packed beds. For example, the k{sub eff} of an alumina packed bed was increased by three times after an ∼8-nm continuous W film with 20 cycles of W ALD, whereas k{sub eff} was decreased on a polymer packed bed with discontinuous, evenly dispersed W-islands due to nanoparticle scattering of phonons. For catalysts, understanding the thermal properties of these packed beds is essential for developing thermally conductive supports as alternatives to structured supports.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A PROTOTYPE FOUR INCH SHORT HYDRIDE (FISH) BED AS A REPLACEMENT TRITIUM STORAGE BED

The Savannah River Site (SRS) tritium facilities have used 1st generation (Gen1) metal hydride storage bed assemblies with process vessels (PVs) fabricated from 3 inch nominal pipe size (NPS) pipe to hold up to 12.6 kg of LaNi{sub 4.25}Al{sub 0.75} metal hydride for tritium gas absorption, storage, and desorption for over 15 years. The 2nd generation (Gen2) of the bed design used the same NPS for the PV, but the added internal components produced a bed nominally 1.2 m long, and presented a significant challenge for heater cartridge replacement in a footprint limited glove-box. A prototype 3rd generation (Gen3) metal hydride storage bed has been designed and fabricated as a replacement candidate for the Gen2 storage bed. The prototype Gen3 bed uses a PV pipe diameter of 4 inch NPS so the bed length can be reduced below 0.7 m to facilitate heater cartridge replacement. For the Gen3 prototype bed, modeling results show increased absorption rates when using hydrides with lower absorption pressures. To improve absorption performance compared to the Gen2 beds, a LaNi{sub 4.15}Al{sub 0.85} material was procured and processed to obtain the desired pressure-composition-temperature (PCT) properties. Other bed design improvements are also presented.

07 ISOTOPE AND RADIATION SOURCES↗

CFD-DEM study of effect of bed thickness for bubbling fluidized beds

The effect of bed thickness in rectangular fluidized beds is investigated through the CFD–DEM simulations of small-scale systems. Numerical results are compared for bubbling fluidized beds of various bed thicknesses with respect to particle packing, bed expansion, bubble behavior, solids velocities, and particle kinetic energy. Good two-dimensional (2D) flow behavior is observed in the bed having a thickness of up to 20 particle diameters. However, a strong three-dimensional (3D) flow behavior is observed in beds with a thickness of 40 particle diameters, indicating the transition from 2D flow to 3D flow within the range of 20–40 particle diameters. Comparison of velocity profiles near the walls and at the center of the bed shows significant impact of the front and back walls on the flow hydrodynamics of pseudo-2D fluidized beds. Hence, for quantitative comparison with experiments in pseudo-2D columns, the effect of walls has to be accounted for in numerical simulations.

42 ENGINEERING↗

Equivalent Test Bed in PSCAD and PSLF for Studying Advanced Power Systems Controller Performance

With increasing popularity of sustainable energy resources, research on power electronic-based renewable generation modeling is gaining impetus to enhance reliability of electric grids with high penetrations of renewable energy. A set of generic and public models for renewable energy are available in commercial positive sequence power system simulation software. However, advanced controller models applicable for renewable resources are typically not included in these tools. To ensure the integrity of the newly developed controller models for renewables in positive sequence simulators for large power systems, it is necessary to validate the dynamic performance of the proposed model with detailed electromagnetic models. This paper creates an equivalent test bed in PSCAD and PSLF for validating the performance of advanced controllers associated with renewable energy sources. To demonstrate the usefulness of the test-bed, a user-defined synthetic inertia (SI) controller model was developed in PSLF and validated through the proposed test bed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coarse-grained discrete particle simulations of particle segregation in rotating fluidized beds in vortex chambers [Discrete particle simulations of particle segregation in rotating fluidized beds in vortex chambers]

Vortex chambers allow the generation of rotating fluidized beds, offering high-G intensified gas-solid contact, gas-solids separation and solids-solids segregation. Focusing on binary particle mixtures and fixing the density and diameter of the heavy/large particles, transient batch CFD-coarse-grained DPM simulations were carried out with varying densities or sizes of the light/small particles to evaluate to what extent combining these three functionalities is possible within a vortex chamber of given design. Both the rate and quality of segregation were analyzed. Within a relatively wide density and size range, fast and efficient segregation takes place, with an inner and slower rotating bed of the lighter/small particles forming within the outer and faster rotating bed of the heavier/large particles. Simulations show that the contamination of the outer bed with lighter particles occurs more easily than contamination of the inner bed with heavier particles and increases with decreasing difference in size or density of the particles. Bubbling in the inner bed is observed with an inner bed of very low density or small particles. Porosity plots show that vortex chambers with a sufficient number of gas inlet slots have to be used to guarantee a uniform gas distribution and particle bed. Lastly, the flexibility of particle segregation in vortex chambers with respect to the gas flow rate is demonstrated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determination of prescription dose for Cs-131 permanent implants using the BED formalism including resensitization correction

Purpose: The current widely used biological equivalent dose (BED) formalism for permanent implants is based on the linear-quadratic model that includes cell repair and repopulation but not resensitization (redistribution and reoxygenation). The authors propose a BED formalism that includes all the four biological effects (4Rs), and the authors propose how it can be used to calculate appropriate prescription doses for permanent implants with Cs-131. Methods: A resensitization correction was added to the BED calculation for permanent implants to account for 4Rs. Using the same BED, the prescription doses with Au-198, I-125, and Pd-103 were converted to the isoeffective Cs-131 prescription doses. The conversion factor F, ratio of the Cs-131 dose to the equivalent dose with the other reference isotope (F{sub r}: with resensitization, F{sub n}: without resensitization), was thus derived and used for actual prescription. Different values of biological parameters such as α, β, and relative biological effectiveness for different types of tumors were used for the calculation. Results: Prescription doses with I-125, Pd-103, and Au-198 ranging from 10 to 160 Gy were converted into prescription doses with Cs-131. The difference in dose conversion factors with (F{sub r}) and without (F{sub n}) resensitization was significant but varied with different isotopes and different types of tumors. The conversion factors also varied with different doses. For I-125, the average values of F{sub r}/F{sub n} were 0.51/0.46, for fast growing tumors, and 0.88/0.77 for slow growing tumors. For Pd-103, the average values of F{sub r}/F{sub n} were 1.25/1.15 for fast growing tumors, and 1.28/1.22 for slow growing tumors. For Au-198, the average values of F{sub r}/F{sub n} were 1.08/1.25 for fast growing tumors, and 1.00/1.06 for slow growing tumors. Using the biological parameters for the HeLa/C4-I cells, the averaged value of F{sub r} was 1.07/1.11 (rounded to 1.1), and the averaged value of F{sub n} was 1.75/1.18. F{sub r} of 1.1 has been applied to gynecological cancer implants with expected acute reactions and outcomes as expected based on extensive experience with permanent implants. The calculation also gave the average Cs-131 dose of 126 Gy converted from the I-125 dose of 144 Gy for prostate implants. Conclusions: Inclusion of an allowance for resensitization led to significant dose corrections for Cs-131 permanent implants, and should be applied to prescription dose calculation. The adjustment of the Cs-131 prescription doses with resensitization correction for gynecological permanent implants was consistent with clinical experience and observations. However, the Cs-131 prescription doses converted from other implant doses can be further adjusted based on new experimental results, clinical observations, and clinical outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TRITIUM IN-BED ACCOUNTABILITY FOR A PASSIVELY COOLED, ELECTRICALLY HEATED HYDRIDE BED

A PAssively Cooled, Electrically heated hydride (PACE) Bed has been deployed into tritium service in the Savannah River Site (SRS) Tritium Facilities. The bed design, absorption and desorption performance, and cold (non-radioactive) in-bed accountability (IBA) results have been reported previously. Six PACE Beds were fitted with instrumentation to perform the steady-state, flowing gas calorimetric inventory method. An IBA inventory calibration curve, flowing gas temperature rise ({Delta}T) versus simulated or actual tritium loading, was generated for each bed. Results for non-radioactive ('cold') tests using the internal electric heaters and tritium calibration results are presented. Changes in vacuum jacket pressure significantly impact measured IBA {Delta}T values. Higher jacket pressures produce lower IBA {Delta}T values which underestimate bed tritium inventories. The exhaust pressure of the IBA gas flow through the bed's U-tube has little influence on measured IBA {Delta}T values, but larger gas flows reduce the time to reach steady-state conditions and produce smaller tritium measurement uncertainties.

07 ISOTOPE AND RADIATION SOURCES↗

Testing of a 40-kWth Counterflow Particle-Supercritical Carbon Dioxide Narrow-Channel, Fluidized Bed Heat Exchanger

Particle-based primary heat exchangers (HXs) must deliver sCO2 fluid temperatures above 700°C to couple particle-based concentrating solar receivers and thermal energy storage (TES) sub-systems with efficient sCO2 power cycles. Particle-sCO2 HX designs have struggled to meet DOE cost targets (≤ $150/kWth) due to the amount of expensive nickel alloys necessary for manufacturing full-scale, particle-sCO2 HXs. Our team has demonstrated that mild bubbling fluidization of falling particles in a counterflow narrow-channel fluidized bed can reduce required HX surface area and thus, costs by increasing particle-wall heat transfer coefficients hT,w > 800 W m-2 K-1. This paper reports on the fabrication and testing of a stainless steel, particle-sCO2 HX with 12 fluidized-bed channels approximately 10.5 mm deep spaced between diffusion-bonded, micro-channel sCO2 plates. The HX with a core length of ≈0.56 m is fed with CARBOBEAD HSP particles through a short, fluidized freeboard zone just above the core. Testing to date in the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories has shown that parallel bed fluidization maintains uniform particle inventory across the instrumented channels. Heat transfer thermal duty between the particle and sCO2 flows exceeds 30 kWth with sCO2 inlet temperatures of 200ºC and particle inlet temperatures up to 440ºC and mass flow rates of 0.2 kg s-1 fluidized by counterflowing gas flow rates of 0.005 kg s-1. Tests at higher particle and sCO2 inlet temperatures (600ºC and 400ºC respectively) are targeted to achieve > 40 kWth with model-predicted overall heat transfer coefficients U > 400 W m-2 K-1.

14 SOLAR ENERGY↗