Search NASA⌕ Search

SEARCH · Search NASA

Results for “benchmark dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

bmdrc: Python package for quantifying phenotypes from chemical exposures with benchmark dose modeling

Though chemical exposures are known to potentially have negative impacts on health, including contributing to chronic diseases such as cancer, the quantitative contribution of risk is not fully understood for every chemical. A commonly used approach to quantify levels of risk is to measure the proportion of organisms (such as a total number of zebrafish on a plate or mice in a cage) with abnormal behavioral responses or morphology at increasing concentrations of chemical exposure. A particular challenge with processing the proportional data from these assays is the appropriate estimation of chemical concentration levels that result in malformations or acute toxicity, as these values typically vary between experimental measurements. The recommended approach by the Environmental Protection Agency (EPA) is to fit benchmark dose curves with specific filters and model fitting steps, which are crucial to properly processing the proportional data. Several tools exist for the fitting of benchmark dose response curves, but none are standalone Python libraries built to process both morphological and behavioral data as proportions with all the EPA recommended filters, filter parameters, models, and model parameters. Thus, here we present the benchmark dose response curve (bmdrc) Python library, which was built to closely follow these EPA guidelines with helpful visualizations of filters and fitted model curves, and reports for reproducibility purposes. bmdrc is open-source and has demonstrated utility as a support package to an existing web portal for information on chemicals (https://srp.pnnl.gov). Our package will support any toxicology analysis where the response is a proportional value at increasing levels of a concentration of a chemical or chemical mixture.

Superfund↗

Benchmark Dose Analysis of DNA Damage Biomarker Responses Provides Compound Potency and Adverse Outcome Pathway Information for the Topoisomerase II Inhibitor Class of Compounds

Genetic toxicology data have traditionally been utilized for hazard identification to provide a binary call for a compound's risk. Recent advances in the scientific field, especially with the development of high‐throughput methods to quantify DNA damage, have influenced a change of approach in genotoxicity assessment. The in vitro MultiFlow® DNA Damage Assay is one such method which multiplexes γH2AX, p53, phospho‐histone H3 biomarkers into a single‐flow cytometric analysis (Bryce et al., [2016]: Environ Mol Mutagen 57:546–558). This assay was used to study human TK6 cells exposed to each of eight topoisomerase II poisons for 4 and 24 hr. Using PROAST v65.5, the Benchmark Dose approach was applied to the resulting flow cytometric datasets. With “compound” serving as covariate, all eight compounds were combined into a single analysis, per time point and endpoint. The resulting 90% confidence intervals, plotted in Log scale, were considered as the potency rank for the eight compounds. The in vitro MultiFlow data showed a maximum confidence interval span of 1Log, which indicates data of good quality. Patterns observed in the compound potency rank were scrutinized by using the expert rule‐based software program Derek Nexus, developed by Lhasa Limited. Compound sub‐classification and structural alerts were considered contributory to the potencies observed for the topoisomerase II poisons studied herein. The Topo II poison Adverse Outcome Pathway was evaluated with MultiFlow endpoints serving as Key Events. The step‐wise approach described herein can be considered as a foundation for risk assessment of compounds within a specific mode of action of interest. Environ. Mol. Mutagen. 2020. © 2020 Wiley Periodicals, Inc.

Wheeldon, Ryan P.↗

A New Shutdown Dose Rate Benchmark Problem for Representative Fusion Applications

Here, this work introduces a new benchmark problem for calculating shutdown dose rates (SDDRs) aimed at fusion reactor applications. The model is designed to represent a simplified version of a typical ITER port plug. The responses of interest include neutron flux, gamma flux, and gamma SDDR at 12 different locations scattered throughout the port. This article outlines the geometry specifications of the problem, provides material definitions for the components, specifies the required responses to be calculated, and presents the source definition information. The need for this benchmark arises from the limited availability of publicly accessible references, with only one benchmark representing the typical dimensions and materials found in fusion systems. This existing benchmark has been cited extensively, reflecting the demand within the scientific community to test both established and novel workflows for SDDR calculations. However, since its presentation at a conference in 2011, the results have become increasingly well known. Moreover, the absence of formal publication and peer review has led to the details of this benchmark being extracted from secondary sources, such as subsequent studies that reference it. As a result, analysts are left with significant flexibility in interpreting the key parameters, which can be adjusted to account for unknown systematic errors, ultimately reproducing the already well-known responses. This new benchmark serves as an updated version of that earlier work, with the aim of providing a more reliable description of the materials and their impurities, which is crucial for assessing activation and subsequent gamma emission. Additionally, it seeks to provide a geometry that more closely represents an ITER port plug. The improvements in the problem definition will lead to a more reproducible benchmark problem, while also presenting the radiation transport community with a completely new challenge. The results will be published in a future article to allow analysts adequate time to analyze this problem independently.

Benchmark↗

The Superfund Research Program Analytics Portal: linking environmental chemical exposure to biological phenotypes

The OSU/PNNL Superfund Research Program represents a longstanding collaboration to quantify Polycyclic Aromatic Hydrocarbons (PAHs) at various superfund sites in the Pacific Northwest and assess their potential impact on human health. To link the chemical measurements to biological activity, we describe the use of the zebrafish as a high-throughput developmental model of human exposure that provides quantitative measurements of the biological ramifications of exposure to toxicants. Toward this end, we have linked over 150 PAHs found at Superfund sites to the effect of these same chemicals in zebrafish, creating a rich dataset that links environmental exposure to biological response. To quantify this response, we have implemented a dose-response modelling pipeline to calculate benchmark dose parameters which enable potency comparison across over 500 chemicals and 10 zebrafish-specific phenotypes. Our portal provides public access to this dataset via an interactive web site designed to support exploration and re-use of these data by the scientific community at http://srp.pnnl.gov.

Gosline, Sara JC↗

PNNL Superfund Research Program Analytics (srpAnalytics Data Release v.1.0)

The OSU/PNNL superfund Research Program represents a longstanding collaboration to quantify Polycyclic Aromatic Hydrocarbons at various superfund sites in the Pacific Northwest and assess their potential impact on human health. To link the chemical measurements to biological activity, we describe the use of the zebrafish as a high-throughput developmental model of human exposure that provides quantitative measurements of the biological ramifications of exposure to toxicants. The PNNL Superfund have implemented a dose-response modelling pipeline to calculate benchmark dose parameters that enable the comparison of potency across chemicals and phenotypes. Our portal provides public access to this dataset and an interactive web site designed to enable exploration and re-use of this data by the scientific community at http://srp.pnnl.gov.

59 BASIC BIOLOGICAL SCIENCES↗

PNNL Superfund Research Program Analytics (srpAnalytics Data Release v.1.0)

The OSU/PNNL superfund Research Program represents a longstanding collaboration to quantify Polycyclic Aromatic Hydrocarbons at various superfund sites in the Pacific Northwest and assess their potential impact on human health. To link the chemical measurements to biological activity, we describe the use of the zebrafish as a high-throughput developmental model of human exposure that provides quantitative measurements of the biological ramifications of exposure to toxicants. The PNNL Superfund have implemented a dose-response modelling pipeline to calculate benchmark dose parameters that enable the comparison of potency across chemicals and phenotypes. Our portal provides public access to this dataset and an interactive web site designed to enable exploration and re-use of this data by the scientific community at http://srp.pnnl.gov.

OSU-PNNL Superfund Research Program Center SRP↗

Aristolochic acid-induced genotoxicity and toxicogenomic changes in rodents

Aristolochic acid (AA) is a group of structurally related nitrophenanthrene carboxylic acids found in many plants that are widely used by many cultures as traditional herbal medicines. AA is a causative agent for Chinese herbs nephropathy, a term replaced later by AA nephropathy. Evidence indicates that AA is nephrotoxic, genotoxic, and carcinogenic in humans; and it also induces tumors in the forestomach, kidney, renal pelvis, urinary bladder, and lung of rats and mice. Therefore, plants containing AA have been classified as carcinogenic to humans (Group 1) by the International Agency for Research on Cancer. In our laboratories, we have conducted a series of genotoxicity and toxicogenomic studies in the rats exposed to AA of 0.1–10 mg/kg for 12 weeks. Our results demonstrated that AA treatments induced DNA adducts and mutations in the kidney, liver, and spleen of rats, as well as significant alteration of gene expression in both its target and nontarget tissues. AA treatments altered mutagenesis- or carcinogenesis-related microRNA expression in rat kidney and resulted in significant changes in protein expression profiling. We also applied benchmark dose (BMD) modeling to the 3-month AA-induced genotoxicity data. The obtained BMDL10 (the lower 95% confidence interval of the BMD 10 that is a 10% increase over the background level) for AA-induced mutations in the kidney of rats was about 7 μg/kg body weight per day. This review constitutes an overview of our investigations on AA-induced genotoxicity and toxicogenomic changes including gene expression, microRNA expression, and proteomics; and presents updated information focused on AA-induced genotoxicity in rodents.

59 BASIC BIOLOGICAL SCIENCES↗

Genotoxicity evaluation using primary hepatocytes isolated from rhesus macaque ( Macaca mulatta )

Non-human primates (NHPs) have played a vital role in fundamental, pre-clinical, and translational studies because of their high physiological and genetic similarity to humans. We report a method to isolate primary hepatocytes from the livers of rhesus macaques (Macaca mulatta) after in situ whole liver perfusion. Isolated primary macaque hepatocytes (PMHs) were treated with various compounds known to have different pathways of genotoxicity/carcinogenicity and the resulting DNA damage was evaluated using the high-throughput CometChip assay. The comet data were quantified using benchmark dose (BMD) modeling and the BMD50 values for treatments of PMHs were compared with those generated from primary human hepatocytes (PHHs) in our previous study. The results showed that despite varying CYP450 enzyme activities, PMHs had the same sensitivity and specificity as PHHs in detecting four indirect-acting (i.e., requiring metabolic activation) and seven direct-acting genotoxicants/carcinogens, as well as five non-carcinogens that are negative or equivocal for genotoxicity in vivo. The BMD50 estimates and their confidence intervals revealed species differences for DNA damage potency, especially for direct-acting compounds. The present study provides a practical method for maximizing the use of animal tissues by isolating primary hepatocytes from NHPs. Our data support the use of PMHs as a reliable surrogate of PHHs for evaluating the genotoxic hazards of chemical substances for humans.

59 BASIC BIOLOGICAL SCIENCES↗

Short-Term Transcriptomic Points of Departure Are Consistent with Chronic Points of Departure for Three Organophosphate Pesticides across Mouse and Fathead Minnow

New approach methods (NAMs) can reduce the need for chronic animal studies. Here, we apply benchmark dose (concentration) (BMD(C))–response modeling to transcriptomic changes in the liver of mice and in fathead minnow larvae after short-term exposures (7 days and 1 day, respectively) to several dose/concentrations of three organophosphate pesticides (OPPs): fenthion, methidathion, and parathion. The mouse liver transcriptional points of departure (TPODs) for fenthion, methidathion, and parathion were 0.009, 0.093, and 0.046 mg/Kg-bw/day, while the fathead minnow larva TPODs were 0.007, 0.115, and 0.046 mg/L, respectively. The TPODs were consistent across both species and reflected the relative potencies from traditional chronic toxicity studies with fenthion identified as the most potent. Moreover, the mouse liver TPODs were more sensitive than or within a 10-fold difference from the chronic apical points of departure (APODs) for mammals, while the fathead minnow larva TPODs were within an 18-fold difference from the chronic APODs for fish species. Short-term exposure to OPPs significantly impacted acetylcholinesterase mRNA abundance (FDR p-value <0.05, |fold change| ≥2) and canonical pathways (IPA, p-value <0.05) associated with organism death and neurological/immune dysfunctions, indicating the conservation of key events related to OPP toxicity. Together, these results build confidence in using short-term, molecular-based assays for the characterization of chemical toxicity and risk, thereby reducing reliance on chronic animal studies.

59 BASIC BIOLOGICAL SCIENCES↗

FY21 Progress of the Oak Ridge Health Physics Research Reactor CAAS Benchmark Evaluation [Slides]

The FY21 version of the evaluation, focusing on element 57 dose at 3 meters, was presented at the ICSBEP Technical Review Group meeting in October 2021 and was not accepted for 2022 publication in the handbook. The main issue was identified and replacement of the element 57 neutron dose benchmark metric by neutron fluence (closer to what was measured) is required. A subgroup was formed, confident for the updated neutron fluence evaluation to be accepted in the ICSBEP handbook. The updated evaluation will be presented again at the 2022 ICSBEP TRG for publication in the 2023 handbook.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of an in vitro three-dimensional HepaRG spheroid model for genotoxicity testing using the high-throughput CometChip platform

Three-dimensional (3D) culture systems are increasingly being used for genotoxicity studies due to improved cell-to-cell interactions and tissue-like structures that are limited or lacking in 2D cultures. The present study optimized a 3D culture system using metabolically competent HepaRG cells for in vitro genotoxicity testing. 3D HepaRG spheroids, formed in 96- or 384-well ultra-low attachment plates, were exposed to various concentrations of 34 test articles, including 8 direct-acting and 11 indirect-acting genotoxicants/carcinogens as well as 15 compounds that show different genotoxic responses in vitro and in vivo. DNA damage was evaluated using the high-throughput CometChip assay with concurrent cytotoxicity assessment by the ATP assay in both 2D and 3D cultures. 3D HepaRG spheroids maintained a stable phenotype for up to 30 days with higher levels of albumin secretion, cytochrome P450 gene expression, and enzyme activities compared to 2D cultures. 3D spheroids also demonstrated a higher sensitivity than 2D cultures for detecting both direct- and indirect-acting genotoxicants/carcinogens, indicating a better prediction of in vivo genotoxicity responses. When DNA damage dose-response data were quantified using PROAST software, 3D spheroids generally had lower or similar benchmark dose values compared to 2D HepaRG cells and were more comparable with primary human hepatocytes. These results demonstrate that 3D models can be adapted to the CometChip technology for high-throughput genotoxicity testing and that 3D HepaRG spheroids may be used as a reliable and pragmatic in vitro approach to better support the hazard identification and risk assessment of potential human genotoxic carcinogens.

60 APPLIED LIFE SCIENCES↗

New Approach Methodology for Assessing Inhalation Risks of a Contact Respiratory Cytotoxicant: Computational Fluid Dynamics-Based Aerosol Dosimetry Modeling for Cross-Species and In Vitro Comparisons

Regulatory agencies are considering alternative approaches to assessing inhalation toxicity that utilizes in vitro studies with human cells and in silico modeling in lieu of additional animal studies. In support of this goal, computational fluid-particle dynamics models were developed to estimate site-specific deposition of inhaled aerosols containing the fungicide, chlorothalonil, in the rat and human for comparisons to prior rat inhalation studies and new human in vitro studies. Under bioassay conditions, the deposition was predicted to be greatest at the front of the rat nose followed by the anterior transitional epithelium and larynx corresponding to regions most sensitive to local contact irritation and cytotoxicity. For humans, simulations of aerosol deposition covering potential occupational or residential exposures (1–50 µm diameter) were conducted using nasal and oral breathing. Aerosols in the 1–5 µm range readily penetrated the deep region of the human lung following both oral and nasal breathing. Under actual use conditions (aerosol formulations >10 µm), the majority of deposited doses were in the upper conducting airways. Beyond the nose or mouth, the greatest deposition in the pharynx, larynx, trachea, and bronchi was predicted for aerosols in the 10–20 µm size range. Only small amounts of aerosols >20 µm penetrated past the pharyngeal region. Using the ICRP clearance model, local retained tissue dose metrics including maximal concentrations and areas under the curve were calculated for each airway region following repeated occupational exposures. These results are directly comparable with benchmark doses from in vitro toxicity studies in human cells leading to estimated human equivalent concentrations that reduce the reliance on animals for risk assessments.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

PNNL-CompBio/bmdrc

Python library for the calculation of benchmark dose response curves

Degnan, David↗

Development and validation of fully open-source R2S shutdown dose rate capabilities in OpenMC *

We present the first fully open-source capabilities for shutdown dose rate (SDR) calculations of fusion energy facilities based on the Rigorous 2-Step (R2S) methodology. These capabilities have been implemented in the OpenMC Monte Carlo particle transport code, building on its existing capabilities while also leveraging new features that have been added to the code to support SDR calculations, such as decay photon source generation. Each of the individual physics components in the R2S workflow—neutron transport, activation, decay photon source generation, and photon transport—have been verified through code-to-code comparisons with MCNP6.2 and FISPACT-II 4.0. These comparisons generally demonstrate excellent agreement between codes for each of the physics components. The full cell-based R2S workflow was validated by performing a simulation of the first experimental campaign from the Frascati Neutron Generator (FNG) ITER dose rate benchmark problem from the Shielding INtegral Benchmark Archive and Database (SINBAD). For short cooling times, the dose calculated by OpenMC agrees with the experimental measurements within the stated experimental uncertainties. For longer cooling times, an overprediction of the shutdown dose was observed relative to experiment, which is consistent with previous studies in the literature. Altogether, these features constitute a combination of capabilities in a single, open-source codebase to provide the fusion community with a readily-accessible option for SDR calculations and a platform for rapidly analyzing the performance of fusion technology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation and verification of PyNE R2S with DAG-OpenMC

The mesh-based Rigorous-Two-Step (R2S) method has been widely used in the accurate estimation of the shutdown dose rate (SDR) of fusion systems. Several mesh-based R2S code has been implemented based on Monte Carlo particle transport code MCNP5 or DAG-MCNP5 and inventory calculation code such as FISPACT-II, ALARA or ACAB. Recently, the OpenMC, a community-developed Monte Carlo particle transport code, implemented the photon particle transport capability, which enables OpenMC to be used in R2S. In this paper, PyNE R2S is extended with the support of DAG-OpenMC, i.e., OpenMC with DAGMC. Modifications that allow PyNE to read the flux result in the state point file of OpenMC has been implemented to PyNE R2S workflow. A custom source routine of OpenMC that reads the photon source file from PyNE R2S and sampling photon particle in OpenMC photon transport has been implemented in OpenMC. With these modifications, PyNE R2S is now capable of performing R2S calculations with both DAG-MCNP5 and DAG-OpenMC. The ITER FNG dose rate benchmark problem has been used to validate the code. The FNG neutron source has been modified for neutron transport with DAG-OpenMC. The shutdown dose rate of 19 cooling times has been calculated and compared with the experimental data and the computational results of other R2S codes. The results of PyNE R2S with DAG-OpenMC show satisfactory agreement with the experimental data and other computational results. Therefore, we consider PyNE R2S with DAG-OpenMC is a reliable code to calculate the SDR of fusion systems.

fusion↗

Shutdown dose rate analysis with the Shift Monte Carlo radiation transport code and modular verification workflow

Calculation of the shutdown dose rate is crucial for safe fusion reactor operations. The Rigorous-two-step (R2S) method is a method that requires connected neutron transport, activation, and gamma transport. Shift has integrated variance reduction with a deterministic solver Denovo, supports multiple geometry formats, and is scalable. These features make it an attractive transport solver choice for an R2S workflow. An R2S workflow for the Shift Monte Carlo code is developed and compared to the existing Oak Ridge National Laboratory Shutdown Dose Rate Code Suite (ORCS) workflow. Also, a Python framework for integrating two R2S workflows is developed to mix and match each step in the R2S workflow for improved collaboration and verification experience. In this study, results show that the Shift-Denovo R2S workflow and the ORCS workflow calculate the shutdown dose rate of the ITER Shutdown Dose Rate benchmark problem with an average relative error of 2.285%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview

From the countless critical experiments performed in the world during the past century, high-quality integral benchmarks experiments have been collected and gathered into the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook), managed by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Working Group. This information preservation and dissemination effort is crucial for reactor licensing as well as criticality and radiation transport modeling validation. This summary reports on the status of a tentative benchmark addition to the ICSBEP Handbook. The proposed benchmark arises from legacy operation data of the Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR). The HPRR was a small, unmoderated, unshielded fast burst reactor that was used for research in health physics and radiobiology as well as teaching and training. As part of a comprehensive investigation of the available HPRR operation data and characteristics, different possibilities for use of the valuable results were studied. A critical experiment benchmark evaluation was performed, analyzing data coming from sub-critical and critical operation of the HPRR during operator training, steady-state irradiation of samples and before critical bursts. The results of the evaluation do not satisfy for the ICSBEP standards as the benchmark relative standard uncertainty is of about 4% for k eff , and the relative difference between sample calculations and expected k eff results is of about 1.5%. Due to those unsatisfactory results, it was decided not to pursue critical experiments evaluation of the HPRR presently and to focus instead on shielding type data for the creation of a criticality accident alarm system (CAAS) and shielding category benchmark, which is currently very scarce in the ICSBEP handbook—especially concerning critical, pulsed assembly, or reactor operation data. Several dosimetry and shielding experiments from HPRR burst operation were evaluated, with different benchmark metrics as sulfur fluence, Element 57 dose, or neutron fluence at different distances and under different shield materials conditions. An evaluation focusing on the Element 57 neutron dose as a benchmark metric was submitted to the ICSBEP Technical Review Group (TRG) meeting in October 2021, and the inclusion of the evaluation in the ICSBEP Handbook was deferred. The main change proposed by the international experiment evaluation experts is to use the neutron fluence measured by Bonner spheres as a benchmark metric. This represents a quantity closer to that actually measured by the experimentalists of the HPRR compared to the Element 57 dose, which adds another step of data transformation, thus potentially adding uncertainty to the benchmark. The evaluation has been updated and will be submitted to the 2022 ICSBEP TRG meeting for inclusion in the 2023 edition of the ICSBEP Handbook. The evaluation is performed using the KENO and MAVRIC combination from the SCALE 6.2.4 code suite which was previously used in similar CAAS benchmarks to allow for the use of variance reduction techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

Computing material volume fractions on a superimposed mesh as applied to Monte Carlo particle transport simulations

Here, we present a newly implemented ray tracing algorithm in OpenMC for efficiently computing material volume fractions on superimposed meshes in complex geometries. By firing rays along each coordinate direction through the geometry, the approach accumulates track-length data in each mesh element, thereby determining the fractional composition of each material. Scaling studies on three different models—a random tetrahedra configuration, the Frascati Neutron Generator ITER dose rate benchmark, and a stellarator design—show excellent parallel performance, with nearly linear speedup on modern multi-threaded and distributed-memory systems. An analysis of the residual error relative to high-resolution reference solutions demonstrated that under optimal conditions it decreases as 1/R, where R is the number of rays fired, making it straightforward to achieve user-prescribed accuracy. This new functionality enables practical, mesh-based approaches for detailed nuclear analyses in production Monte Carlo workflows without resorting to expensive, fully conformal or unstructured meshing.

Monte Carlo↗