Search NASA⌕ Search

SEARCH · Search NASA

Results for “bias field”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Bias-field equalizer for bubble memories

Magnetoresistive Perm-alloy sensor monitors bias field required to maintain bubble memory. Sensor provides error signal that, in turn, corrects magnitude of bias field. Error signal from sensor can be used to control magnitude of bias field in either auxiliary set of bias-field coils around permanent magnet field, or current in small coils used to remagnetize permanent magnet by infrequent, short, high-current pulse or short sequence of pulses.

Keefe, G. E.↗

Robust Skyrmion Shift Device Through Engineering the Local Exchange-Bias Field

Magnetic skyrmions are topologically protected spin structures, offering great promise as information carriers for future spintronic devices. However, a series of challenges, such as unreliable skyrmion motion, pinning effects, and a weak read-out signal, prevent the development of skyrmionic applications. The recently demonstrated capability to engineer the local exchange-bias field (LEBF) in an exchange biased composite, provides solutions to these challenges. By exploiting LEBF, we design and analyze a robust skyrmion shift device. LEBF-induced magnetic domain walls form the boundary of the device channel, and LEBF potential wells are implemented in the channel for positioning skyrmions. Based on simulations with comprehensive models, we demonstrate the proposed device has the advantages of (i) localizing the skyrmions in the absence of current, (ii) suppressing skyrmion annihilation during transport, (iii) promoting steady skyrmion motion, (iv) enhancing the skyrmion velocity, and (v) magnifying the read-out signal. Our results form the basis for the design of robust skyrmion devices through LEBF engineering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

IRAS galaxies versus POTENT mass - Density fields, biasing, and Omega

A comparison of the galaxy density field extracted from a complete redshift survey of IRAS galaxies brighter than 1.936 Jy with the mass-density field reconstructed by the POTENT procedure from the observed peculiar velocities of 493 objects is presented. A strong correlation is found between the galaxy and mass-density fields; both feature the Great Attractor, part of the Perseus-Pisces supercluster, and the large void between them. Monte Carlo noise simulations show that the data are consistent with the hypotheses that the smoothed fluctuations of galaxy and mass densities at each point are proportional to each other with the 'biasing' factor of IRAS galaxies, b(I), and that the peculiar velocity field is related to the mass-density field as expected according to the gravitational instability theory. Under these hypotheses, the two density fields can be related by specifying b(I) and the cosmological density parameter, Omega.

Dekel, Avishai↗

Disorder-induced time effect in the antiferromagnetic domain state of Fe 1+ y Te

Herein we report on temperature-dependent soft X-ray absorption spectroscopy (XAS) measurements utilizing linearly polarized synchrotron radiation to probe magnetic phase transitions in iron-rich Fe 1+y Te (y ≈ 0.12). X-ray magnetic linear dichroism (XMLD) signals, which sense magnetic ordering processes at surfaces, start to increase monotonically below the Néel temperature T N = 57 K. This increase is due to a progressive bicollinear antiferromagnetic (AFM) alignment of Fe spins of the monoclinic Fe 1+y Te parent phase. This AFM alignment was achieved by a [1 0 0]-oriented biasing field favoring a single-domain state during cooling across T N . Our specific heat and magnetization measurements confirm the bulk character of this AFM phase transition. On longer time scales, however, we observe that the field-biased AFM state is highly unstable even at the lowest temperature of T = 3 K. After switching off the biasing field, the XMLD signal decays exponentially with a time constant τ = 1506 s. The initial XMLD signal is restored only upon repeating a cycle consisting of heating and field-cooling through T N . We explain the time effect by a gradual formation of a multi-domain state with 90° rotated AFM domains, promoted by structural disorder, facilitating the motion of twin-domains. Significant disorder in our Fe 1+y Te sample is evident from our X-ray diffraction and specific heat data. The stability of magnetic phases in Fe-chalcogenides is an important material property, since the Fe(Te 1-x Se x ) phase diagram shows magnetism intimately connected with superconductivity.

36 MATERIALS SCIENCE↗

Optically pumped, radio-frequency atomic magnetometry with feedback stabilization

An optically pumped, atomic magnetometer incorporates a feedback system for stabilizing the magnetic bias field and suppressing unwanted background fields. The magnetic bias field is applied to a vapor cell containing host atoms of two different species, each of which resonates at a different Larmor frequency when both are subjected to the same magnetic bias field. One species provides the feedback for stabilizing the bias field, thereby creating a stabilizing magnetometer portion that nulls out the unwanted background fields. The other species provides magnetic field detection or signal reception on a radio communication frequency of interest, thereby creating a signal magnetometer portion that permits detection of the signal at the radio communication frequency.

Schwindt, Peter D. D.↗

All-optical, Microwave-free NV-Diamond Magnetometer for Weak Magnetic Field Environments

Sensitive nitrogen-vacancy (NV) magnetometry typically requires a bias field to lift the spin level degeneracy and has commonly utilized microwave sources to selectively manipulate the sensor's spin state. However, this external bias field and microwave sources may perturb the sample of interest or be incompatible with operational conditions. Here, we demonstrate an all-optical, microwave-free NV-diamond magnetometer in the presence of weak or no bias magnetic field (<20 G). We experimentally measure photoluminescence spectra using diamonds with varying NV concentrations; and numerically simulate matching features due to cross-relaxation between NVs. Our results pave the way towards a sensitive probe to study magnetic systems that can be disrupted by microwave signals and can only tolerate weak bias magnetic field.

Ung, Kristine↗

Study of the Dependence on Magnetic Field and Bias Voltage of an AC-Biased TES Microcalorimeter

At SRON we are studying the performance of a Goddard Space Flight Center single pixel TES microcalorimeter operated in the AC bias configuration. For x-ray photons at 6keV the AC biased pixel shows a best energy resolution of 3.7eV, which is about a factor of 2 worse than the energy resolution observed in identical DC-biased pixels. To better understand the reasons of this discrepancy, we investigated the detector performance as a function of temperature, bias working point and applied magnetic field. A strong periodic dependence of the detector noise on the TES AC bias voltage is measured. We discuss the results in the framework of the recent weak-link behaviour observed inTES microcalorimeters.

Bandler, Simon↗

Study of the Dependency on Magnetic Field and Bias Voltage of an AC-Biased TES Microcalorimeter

At SRON we are studying the performance of a Goddard Space Flight Center single pixel TES microcalorimeter operated in an AC bias configuration. For x-ray photons at 6 keV the pixel shows an x-ray energy resolution Delta E(sub FWHM) = 3.7 eV, which is about a factor 2 worse than the energy resolution observed in an identical DC-biased pixel. In order to better understand the reasons for this discrepancy we characterized the detector as a function of temperature, bias working point and applied perpendicular magnetic field. A strong periodic dependency of the detector noise on the TES AC bias voltage is measured. We discuss the results in the framework of the recently observed weak-link behaviour of a TES microcalorimeter.

Gottardi, L.↗

Skyrmion-Based Programmable Logic Device with Complete Boolean Logic Functions

A skyrmionic programmable logic device (SkrPLD) with complete Boolean logic functions is proposed and analyzed by micromagnetic simulations. The SkrPLD is based on an antiferromagnet/ferromagnet bilayer structure, in which the antiferromagnetic layer supports the interfacial Dzyaloshinskii–Moriya interaction and the out-of-plane exchange bias field for stabilizing a zero-field skyrmion. By varying the local exchange bias field, artificial pinning sites are introduced for trapping the skyrmions. Depending on the input currents and the initial position of skyrmions at different pinning sites, different logic functions can be realized. Micromagnetic simulations show that the proposed SkrPLD has robust performance even under thermal fluctuations and inhomogeneity effects. Our work can provide insights for the design of programmable spin logic devices.

74 ATOMIC AND MOLECULAR PHYSICS↗

A current access, self-structured, multilayered bubble domain memory

Preliminary experimental results are reported on a self-structured, multilayer bubble memory with buried data layer. Stripe domains are used to move carrier bubbles by magnetostatic coupling. An expression is derived for that coupling as a function of thickness of the GGG separation layer. Experimental values of coupling are given as a function of bias field. An expression for stripe curvature as a function of bias field is derived. The performance of seven different current access stripe propagation circuits is reported.

Stermer, R. L., Jr.↗

Stripe stabilization in vertical Bloch line memory

Long, partial rectangular grooves have been made to reside below the stripe-confinement groove on a garnet surface, in order to stabilize minor loop stripes in a vertical Bloch-line memory. The test chip contained, in addition to either 10 or 20 minor-loop grooves, 10 read/write gate grooves and a major line groove; both 10 and 20 micron groove periods were tested. As the bias field was gradually decreased, bubbles began to stripe out. These stripes were stable at bias fields in the 70-80 Oe range. When stripes escaped from the groove, the even occurred from the end which does not face a read/write gate groove.

Wu, J. C.↗

Tensor network study of the m = 1/2 magnetization plateau in the Shastry-Sutherland model at finite temperature

The two-dimensional infinite projected entangled pair state tensor network is evolved in imaginary time with the full update (FU) algorithm to simulate the Shastry-Sutherland model in a magnetic field at finite temperature directly in the thermodynamic limit. We focus on the phase transition into the m = 1/2 magnetization plateau, which was observed in experiments on SrCu 2 (BO 3 ) 2 . For the largest simulated bond dimension, the early evolution in the high-temperature regime is simulated with the simple update (SU) scheme and then, as the correlation length increases, continued with the FU scheme towards the critical regime. We apply a small symmetry-breaking bias field and then extrapolate towards zero bias using a simple scaling theory in the bias field. The combined SU + FU scheme provides an accurate estimate of the critical temperature, even though the results could not be fully converged in the bond dimension in the vicinity of the transition. Here, the critical temperature estimate is improved with a generalized scaling theory that combines two divergent length scales: One due to the bias, and the other due to the finite bond dimension. The obtained results are consistent with the transition being in the universality class of the two-dimensional classical Ising model. The estimated critical temperature is 3.5(2) K, which is well above the temperature 2.1 K used in the experiments.

2-dimensional systems↗

Chandra ACIS Observations of Jovian X-Ray Emission

On November 25 and 26, 1999, the Chandra X-ray spacecraft conducted a set of four 19,000 sec observations of Jupiter. The ACIS-S instrument configuration was used for its good low energy efficiency and spatial resolution. An anomalous response was obtained which was subsequently attributed to strong jovian infrared radiation penetrating the detector and piling up spurious events across the entire X-ray range. However, the pre-observation establishment of an offsetting bias field has allowed the recovery of data from that portion of Jupiter's disc which remained within the elevated portion of the bias field during the observation. This ranges from fewer than 3000 sec to the entire observing time for about 10% of the planet. Auroral emission is seen near both poles in each observation. The northern aurora ia overall more intense than the southern, consistent with prior Einstein and ROSAT Observatory results. The southern aurora shows more modulation with Jupiter's rotation than the northern. Spatial resolution has been improved by at least a factor of two over prior measurements but convincing evidence of structure has not been seen. Lower latitude emission, first observed by ROSAT, is confirmed with flux levels averaging more than a factor of five below peak auroral values. Pronounced variation in the observed emission has occurred over the observing period. The spectral response extends from 0.24 keV, below which noise dominates, to about 1.2 keV. For all four observations the spectrum is clearly enhanced between 0.45 and 0.85 keV. This is apparently unequivocal evidence that Jupiter's X-ray emission is the result of oxygen and perhaps sulfur ions precipitating into the planet's atmosphere, where they undergo charge exchange interactions. The identification of specific transitions lines in the spectrum is among the ongoing efforts. A bremsstrahlung component has not yet been identified.

Garmire, Gordon↗

Exchange bias switching in an antiferromagnet/ferromagnet bilayer driven by spin-orbit torque

Here the electrical manipulation of magnetization and exchange bias in antiferromagnet/ferromagnet thin films could be of use in the development of the next generation of spintronic devices. Current-controlled magnetization switching can be driven by spin-orbit torques generated in an adjacent heavy metal layer, but these structures are difficult to integrate with exchange bias switching and tunnelling magnetoresistance measurements. Here, we report the current-induced switching of the exchange bias field in a perpendicularly magnetized IrMn/CoFeB bilayer structure using a spin-orbit torque generated in the antiferromagnetic IrMn layer. By manipulating the current direction and amplitude, independent and repeatable switching of the magnetization and exchange bias field below the blocking temperature can be achieved. The critical current density for the exchange bias switching is found to be larger than that for CoFeB magnetization reversal. X-ray magnetic circular dichroism, polarized neutron reflectometry measurements and micromagnetic simulations show that a small net magnetization within the IrMn interface plays a crucial role in these phenomena.

42 ENGINEERING↗

Plasma Guns for Magnetized Fuel Targets for PJMIF

In plasma jet driven magneto-inertial fusion (PJMIF) an array of discrete supersonic plasma jets is used to form a spherically imploding plasma liner, which then compresses a magnetized plasma target to fusion conditions. With funding from ARPA-E’s ALPHA program and from Strong Atomics LLC, HyperJet Fusion Corp and HyperV Technologies Corp. previously developed the plasma guns required for an experimental demonstration of the plasma liner formation part of the concept. A 36-gun demonstration of an imploding spherical plasma liner is currently underway on the PLX facility at Los Alamos National Laboratory. This present project addresses the next step required for a complete PJMIF concept, i.e. developing the magnetized plasma target. We proposed to form the target by stagnating a number of magnetized plasma jets in the center of the target chamber. This is accomplished by adding a bias field coil to the plasma liner gun to form a magnetized plasma jet. This experimental development took place at HyperJet in a geometry replicating the bias field environment that will be seen on a PLX port so the results are directly transferrable to the PLX experiment. The objective of this effort was the technical development and characterization of a new magnetized plasma jet using a high-performance, high momentum flux, contoured-gap coaxial plasma gun appropriate for use on the next stage of the PLX experiment. Electromagnetic modeling of the coil indicated the coil was best placed around the aluminum tubes of the gun transmission line, rather than around the chamber port as originally proposed. This maximized field strength in the breech and yielded much better flux linkage between gun electrodes. A 30-turn coil was ultimately implemented, allowing long pulses that could diffuse through the metal walls on the timescale of interest. \machtwo modeling predicted that less capacitance in the main PFN could potentially improve plasma jet velocities due to better matching of the current to the smaller plasma mass and the existing electrode contour designed to suppress blowby. This proved true, as testing showed markedly improved performance when the original 600uF bank was reduced to 400uF. A number of diagnostics were built and/or upgraded in order to characterize the plasma jets, inluding laser interferomtery for density, photodiodes for velocity, Bdot probes for magnetic field measurements, a Triple probe for temperature measurements, and spectroscopy for impurity content. A plasma gun with the 30-turn magnet coil installed, a 70% reduction in gas valve plenum volume, and a 33% reduction in main PFN capacitance produced a dense, high velocity, well magnetized plasma jet. We met or exceeded virtually all of the plasma jet parameter goals. Peak velocity of 135 km/s exceeded the 100 km/s goal by 35%, while the peak density of over 1.0x10 15 cm -3 was 3.3 times the goal of >3.0x10 14 cm -3 . Shot-to-shot repeatability is excellent, with a jitter of less than 300ns observed on the arrival fronts of the photodiode signals from one shot to the next. Average plasma jet lengths of 33cm (at 120km/s) were slightly longer than the 20cm goal, but jets as short as 11.8cm were observed at 135km/s. Mass is much higher than the targeted goal, averaging 106ug per shot compared to 20ug. The magnetic field is still a bit lower than desired, with a maximum to date of ~811G, compared to the goal of 1000G. Average values, though, were typically in the 300-450G range, when measured further downstream after some expected in flight decay. Temperature measurements are still a work in progress. Increasing the B field and completing temperature measurements will be continued on into the ongoing BETHE project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Partially Grooved Domain Stabilization Structures for Vertical Bloch Line Memory

Bias field stability ranges were measured and numerically simulated for magnetic domains ingarnets stabilized by partially grooved rectangular and ring grooves. Simulation results agreefavorably with experimental results when finite slope effects of the groove walls are included. Asbias fields increase, rectangular and ring domains both destabilize through stripe head recession. Asbias fields decrease, destabilization in rectangular domains occurs by runout, while destabilization inring domains occurs by midstripe domain buckling. While ring domains are stable at lower biasfields than rectangular domains, bias field stability ranges are approximately equal. Hence, for thesame partial grooving depth, rectangular domains are preferred because they offer higher storagedensity potential in Vertical Block Line (VBL) storage arrays as long as bit propagation margins atstripe ends are sufficient.

Katti, R. R.↗

Low-frequency atomic electrometry

In a method of atomic electrometry, EIT spectroscopy is performed on host atoms of an alkali metal in a vapor cell. The EIT spectroscopy indicates a resonant energy of a probed Rydberg state of the host atoms. The vapor cell is exposed to an ambient electric field. A shift in the resonant energy as indicated by the EIT spectroscopy is observed and interpreted as a measurement of the ambient field. During the measurement of the ambient field, a bias electric field is generated inside the vapor cell by shining light into the vapor cell from a light source situated outside of the cell. The bias field is useful for increasing the sensitivity of the measurement.

Jau, Yuan-Yu↗