Search NASA⌕ Search

SEARCH · Search NASA

Results for “bifacial PV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Bifacial PV: De Tudo um Pouco

A tecnologia fotovoltaica evolui constantemente, e desde aproximadamente 2017 os modulos bifaciais chegaram para ficar. A mudanca, que foi simples em termos de fabricacao das celulas PERC, oferece um grande ganho na producao de energia. E por isso que agora representam 75% das novas usinas centralizadas dos Estados Unidos. Nesta palestra, vou apresentar a pesquisa de PV bifacial no NREL, onde temos um campo de 75 kW com 5 tecnologias bifaciais comerciais ao lado dos equivalentes monofaciais (mesmas celulas), com dados open-source desde 2019. Vou falar sobre o que estamos observando em relacao a performance, degradacao, o posicionamento dos sensores de irradiacao, sombreamento e efeitos de borda (edge effects). Para terminar, apresentarei nova pesquisa sobre a otimizacao do albedo e agriPV, e compartilharei novidades nas ferramentas de modelagem bifacial e AgriPV desenvolvidas pelo NREL.

bifacial↗

A New Chapter in Solar: Bifacial PV from Emerging Topic to Core Curriculum

Associated with the new edition of the bifacial PV book, this talk reviews the transition of bifacial PV from niche innovation to standard practice, including progress in modeling and performance evaluation, and ongoing challenges in reliability, new applications, and fleet repowering.

14 SOLAR ENERGY↗

Comparative Analysis of Rear Irradiance Modeling Methods for Bifacial PV Systems on Single-Axis Trackers Under Varying Albedo Conditions

This study compares three rear-side irradiance modeling methods for bifacial PV systems on single-axis trackers: (i) the 2D View Factor (VF) model in PVsyst(R), (ii) the open-source PVFactors VF model, and (iii) the Ray Tracing (RT) technique using bifacial_radiance. Simulations were benchmarked against field measurements from a pilot PV plant with rear-side sensors at the torque tube height. Results show that all models underestimated the non-uniformity of rear irradiance along the module length and overestimated the total rear irradiance incident on the module. However, since bifacial gain represents only a fraction of the system's total energy, the resulting energy yield differences among methods remained within +- 2 % of measured values, which is typical for such simulations. While the overall energy impact is limited, this study characterizes the specific limitations of each modeling approach, supporting further improvements in bifacial PV performance assessment methods.

14 SOLAR ENERGY↗

Field Study of Nighttime Leakage Currents in Bifacial PV Modules: Correlation with Atmospheric Electric Field Data

Leakage currents measured on PV modules in the field originate from a potential difference between the modules' frame and the cells. They can be a relative indicator of Potential-Induced Degradation (PID) severity, especially when comparing the same module design in a different environment. As modules are not operating at night, no leakage current should be observed but our team has reported several events of nighttime leakage currents on bifacial PV modules. These events have been firstly observed during a thunderstorm that are characterized by strong atmospheric electrical field values. This lead us to believe that nighttime leakage currents could originate from the atmospheric electric charges. In this paper, we correlate nighttime leakage currents measured on bifacial PV modules with field mill data to identify the origin of nighttime leakage currents. Our results show that so far, no leakage currents at night occur when the atmospheric electric field is between 0 and 150–200 V/m (standard value for fair weather). As soon as the atmospheric electric field is out of this range, leakage currents are observed with or without rain involved. This suggests a transport of charged particles from the atmosphere to the modules' frame. A combination of heavy rain with strong atmospheric electric field results into high nighttime leakage currents with a magnitude up to 8 times higher than what observed during the day with -1500V applied. This is explained by an easier transport of the charged particles through the water droplets. Based on these results, leakage currents observed during the day might not be only due to the inherent potential difference between the frame and the cells depending on the atmospheric electric field activity. We believe that it should be taken into account in PID studies.

14 SOLAR ENERGY↗

Bifacial PV Module Energy Modeling Validation Study

The cost delta between monofacial and bifacial photovoltaic (PV) modules was decreasing in 2018 when this study was initially proposed, making bifacial modules an attractive offering. However, there were limited field studies available that could be considered utility-scale representative, and PV module manufacturers were stating large ranges for the expected energy yield improvements of bifacial technology. This generated uncertainties regarding bifacial performance gains and the actual LCOE (levelized cost of energy). There was also relatively low confidence in the industry’s energy modeling tools’ ability to accurately predict bifacial energy yield, meaning that early adopters of bifacial modules were not able to fully account for the increased energy yield in their energy and financial models. The intent of this project was to provide the solar industry with greater certainty on the energy yield gains of bifacial modules and provide higher confidence in the ability for different energy modeling software to model bifacial PV site performance. Achieving this would allow for bifacial technology to become bankable (i.e. accepted by Independent Engineers, site financiers and other PV site stakeholders), offering a step change in PV site performance that had not been seen since the widespread adoption of the single-axis tracker. Over the course of this study other economic factors including a significant tariff exemption for bifacial modules resulted in accelerated adoption of bifacial technology throughout the US utility scale solar segment. The number of early adopters increased rapidly, and with many investors accepting this module choice the question of bifacial bankability was seemingly answered faster than expected. However, PVEL’s study has still achieved significant accomplishments in demonstrating the accuracy of bifacial modeling across three different software platforms. The results of this study have shown that the mean biased error (MBE) between the field data and the predicted values from all three software platforms were aligned with a maximum MBE of 1.3% and a minimum MBE of -1.8%.

14 SOLAR ENERGY↗

Validating Irradiance Models for High-Latitude Vertical Bifacial Photovoltaic Systems

Bifacial photovoltaic systems oriented vertically facing east-west are an emerging design, targeting production in morning and afternoon hours and providing competitive annual energy yield to traditional south-tilted modules for high latitude locations. The accuracy of existing bifacial PV models when modules are oriented vertically has yet to be examined in detail. Here, we compare four bifacial PV irradiance models in ~150 locations between 15-80 degrees N on the utility-scale, finding higher inter-model deviations for vertical PV systems than south-tilted across all latitudes less than 75 degrees N. We validate model-predicted irradiance with test-site data collected in Golden, Colorado and Fairbanks, Alaska for E-W vertical and south-tilted arrays. View factor models agree with E-W vertical test-site data in Golden with RMSE=15%. Modelling error increases for the Alaskan test-site to RMSE values between 21-30%, driven in part by high albedo measurement uncertainty during snowy months.

bifacial↗

Presenting a Model to Predict Changing Snow Albedo for Improving Photovoltaic Performance Simulation

As photovoltaic (PV) deployment increases worldwide, PV systems are being installed more frequently in locations that experience snow cover. The higher albedo of snow, relative to the ground, increases the performance of PV systems in northern and high-altitude locations by reflecting more light onto the PV modules. Accurate modeling of the snow’s albedo can improve estimates of PV system production. Typical modeling of snow albedo uses a simple two-value model that sets the albedo high when snow is present, and low when snow is not present. However, snow albedo changes over time as snow settles and melts and a binary model does not account for transitional changes, which can be significant. Here, we present and validate a model for estimating snow albedo as it changes over time. The model is simple enough to only require daily snow depth and hourly average temperature data, but can be improved through the addition of site-specific factors, when available. We validate this model to quantify its ability to more accurately predict snow albedo and compare the model’s performance against satellite imagery-based methods for obtaining historical albedo data. In addition, we perform modeling using the System Advisor Model (SAM) to show the impact of changes in albedo on energy modeling for PV systems. Overall, our albedo model has a significantly improved ability to predict the solar insolation on PV modules in real time, especially on bifacial PV modules where reflected irradiance plays a larger role in energy production.

Pike, Christopher (ORCID:0000000155888033)↗

Susceptibility to polarization type potential induced degradation in commercial bifacial p-PERC PV modules

Potential induced degradation (PID) is a reliability issue affecting photovoltaic (PV) modules, mainly when PV strings operate under high voltages in hot/humid conditions. Polarization-type PID (PID-p) has been known to decrease module performance quickly. PID-p can be reduced or recovered under the light in some cases, but this effect, as expected, would be less pronounced on the rear side of bifacial PV modules receiving lower irradiance. As bifacial PV modules are projected to dominate the PV market within the next 10 years, it is crucial to understand the PID-p issue in bifacial modules better. In this study, we performed indoor PID testing to induce PID-p on 14 commercial bifacial p-PERC modules with three different module constructions from three manufacturers. Here, four rounds (+ve and –ve polarities for front and rear sides) of PID testing are done at 25°C, 54% relative humidity (RH) for 168 h using the aluminum foil method. Each module side (front cell side and back cell side) is tested individually under both negative and positive voltage bias. The results show that the highest degradation of 32% in maximum power (Pmax) at standard test conditions (1000 W/m 2 ) and 51% at low irradiance (200 W/m 2 ) has been observed in some cases. Recovery under sunlight is also done, and outcomes show a near-complete recovery in Pmax. This study presents an extensive experimental methodology and a detailed analysis to systematically and simultaneously/sequentially evaluate multiple construction types of bifacial modules to the PID-p susceptibility and recovery.

14 SOLAR ENERGY↗

Sequential Stress Identifies Processing Defects in Bifacial Photovoltaic Modules That Limit Durability

Here, we use sequential stress to investigate hurdles to bifacial photovoltaic (PV) module durability from lamination defects. We test mini-modules with glass/glass (G/G) and glass/transparent-backsheet (G/TB) constructions using either ethylene vinyl acetate or polyolefin elastomer (POE) based encapsulants under a modified IEC 63209-2 sequential stress. This sequence includes multiple iterations of damp heat (DH200), full spectrum light exposure (A3), thermal cycling (TC50), and humidity/freeze (HF10). We compare indoor stress with outdoor exposure. Results show similar relative trends in degradation after a year outdoors compared to our first stress cycle. Subsequent stress cycles impart more severe damage than outdoor exposure for the short outdoor duration used here. Edge-pinch lamination defects in G/G mini-modules limit durability causing delamination and cell cracks. Conversely, we observe greater degradation in G/TB mini-modules compared to G/G in the later stages of the stress sequence when the backsheets are directly exposed to UV-containing light. Our results highlight: 1) the utility of sequential stress testing to uncover degradation modes in bifacial PV, 2) implications of using mini-modules for testing PV quality, and 3) the importance of lamination defects that must be avoided to ensure durability as the industry adopts G/G or G/TB packaging.

14 SOLAR ENERGY↗

Catching Rays: How Bifacial_Radiance Sheds Light on the Future of Solar PV

The challenge of energy transition is immediate and immense, with current projections targeting 75 TW of photovoltaics (PV) capacity globally by 2050. Alongside the rapid deployment is the "solar-coaster" ride the PV industry experiences with evolving technologies and novel installation methods. In 2016, NREL developed bifacial_radiance, a python open-source modeling tool for bifacial PV. This tool is a wrapper of the raytracing engine Radiance, which you all know better than us at this workshop. Bifacial_radiance integrates the many characteristics of common PV systems to model irradiance on both the front and rear sides of bifacial PV technology - a technology that now represents 75% of utility-scale deployment in the US. Bifacial_radiance has been pivotal for understanding bifacial system performance, shading, and edge effects, and now agrivoltaics research. It has also helped develop simplified models used in PV due diligence tools for optimizing new deployments or evaluating the performance of existing projects. Now, it's the go-to comparison tool for many university, and industry-developed systems modeling tools, and a pivotal tool for further research in photovoltaics. This talk will cover the needs bifacial_radiance addresses as an open-source tool, its development path, and the opportunity for any raytracer to shine light on the solar industry through research and practical application of modeling in regular site installations and novel setups like agrivoltaics and vertical panels at high latitudes (and even the South Pole!).

agrivoltaics↗

PV Durability at Scale: Assessing Bifacial and TOPCon Field Performance

Recent field performance results of TOPCon and PERC Bifacial modules are presented based on small-scale deployments at NLR, and a selection of 3rd-party residential data. Bifacial PERC degradation rates are a median of -1 % / yr with bifacial TOPCon modules at a similar rate of -1.1 %/yr over the first couple of years. Comparable PERC Monofacial modules have a degradation rate of -0.5%/yr. Some TOPCon modules exhibited an indoor dark metastability effect which requires recovery by light soaking or UV exposure prior to IV curve measurement. Further monitoring is needed to confirm the long-term stability of TOPCon modules.

14 SOLAR ENERGY↗

Highly efficient bifacial single-junction perovskite solar cells

Bifacial photovoltaics (PV) harvest solar irradiance from both their front and rear surfaces, boosting energy conversion efficiency to maximize their electrical power production. For single-junction perovskite solar cells (PSCs), the performance of bifacial configurations is still far behind that of their state-of-the-art monofacial counterparts. Here, in this paper, we report on highly efficient, bifacial, single-junction PSCs based on the p-i-n (or inverted) architecture. We used optical and electrical modeling to design a transparent conducting rear electrode for bifacial PSCs to enable optimized efficiency under a variety of albedo illumination conditions. The bifaciality of the PSCs was about 91%–93%. Under concurrent bifacial measurement conditions, we obtained equivalent, stabilized bifacial power output densities of 26.9, 28.5, and 30.1 mW/cm 2 under albedos of 0.2, 0.3, and 0.5, respectively. We further showed that bifacial perovskite PV technology has the potential to outperform its monofacial counterparts with higher energy yields and lower levelized cost of energy (LCOE).

14 SOLAR ENERGY↗

Comparing Outdoor to Indoor Performance for Bifacial Modules Affected by Polarization-Type Potential-Induced Degradation

Bifacial photovoltaic (PV) modules have the advantage of using light reflected off of the ground to contribute to power production. Predicting the energy gain is challenging and requires complex models to do so accurately. Often, module degradation over time is neglected in models for the sake of simplicity or is underestimated. Comparing outdoor and indoor current–voltage (I–V) performance for bifacial modules is more challenging than for monofacial modules, as there are additional variables to consider such as rear albedo non-uniformity, cell mismatch, and their effects on temperature. This challenge is compounded when heterogeneous degradation modes occur, such as polarization-type potential-induced degradation (PID-p). To examine the effects of PID-p on I–V predictions using an empirical data-driven approach, 16 bifacial PERC modules are installed outdoors on racks with different albedo conditions. A subset is exposed to high-voltage biases of −1500 V or +1500 V. Outdoor data are traced at irradiance ranges of 150–250 W/m 2 , 500–600 W/m 2 , and 900–1000 W/m 2 . These curves are corrected using control module temperature, wire resistivity, and module resistance measured indoors. We examine several methods to transform indoor I–V curves to accurately, and more simply than existing methods, approximate outdoor performance for bifacial modules without and with varying levels of PID-p degradation. This way, bifacial performance modeling can be more accessible and informed by fielded, degraded modules. Distributions of percent errors between indoor and outdoor performance parameters and Mean Absolute Percent Errors (MAPEs) are used to assess method quality. Results including low-irradiance data (150–250 W/m 2 ) are discussed but are filtered for quantifying method quality as these data introduce substantial errors. The method with the most optimal tradeoff between low MAPE and analysis simplicity involves measuring the front side of a module indoors at an irradiance equal to plane-of-array irradiance plus the product of module bifaciality and albedo irradiance. This method gives MAPE values of 1–6.5% for non-degraded and 1.6–5.9% for PID-p degraded module performance.

14 SOLAR ENERGY↗

Bifacial_Radiance v0.4.2 [SWR-18-03]

The bifacial_radiance software contains a series of Python wrapper functions to make working with RADIANCE easier, particularly for the PV researcher interested in bifacial PV performance. For more information, check out our documentation, Tutorials in the form of Jupyter Notebooks, or refer to our Wiki and Issues page. Installation https://youtu.be/4A9GocfHKyM This video shows how to install the bifacial_radiance software and all associated software needed. More info on the Wiki. Instructions are also shown below. For detailed instructions of how to install bifacial_radiance, you can also refer to the installation guide. A GUI has been added in version 3.0. The GUI reads/writes all input parameters necessary to run a simulation, and runs the specified simulation by calling the correct functions with the specified parameters. So no need to use a journal or a script! But you still need to install following the procedure below.

Deline, Chris↗