Search NASA⌕ Search

SEARCH · Search NASA

Results for “blocked detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fourier-based methods for removing mesh anomalies from angle resolved photoemission spectra

Recent improvements to spatial resolution in angle-resolved photo-emission spectroscopy (ARPES) have made it common to perform measurements with a very brief dwell time, for the purpose of mapping the spectral function over large surface regions. However, rapid measurement modalities can suffer a grid-like intensity modulation due to a wire mesh that is typically placed in front of the ARPES detector to block stray electrons. Here, we explore Fourier-based methods that can effectively remove this artifact, and improve the quality of ARPES images obtained in rapid scanning modes. In conclusion, an open source software package is provided containing implementations of demonstrated algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System and method for determining absolute carrier-envelope phase of ultrashort laser pulses

A system for determining an absolute carrier-envelope phase (CEP) of ultrashort laser pulses includes a laser system for generating a laser beam including ultrashort optical pulses of a duration of less than 10 fs, an ultrabroadband quarter-wave plate configured to polarize the laser beam, and a gas jet emitting a continuous jet stream into the laser beam. The system includes focusing optics to adjust a focal spot of the laser beam to the gas jet, and a detector arrangement including a beam block and a microchannel plate (MCP) imaging detector, wherein the laser beam is directed to the detector arrangement. The method involves using angular streaking to determine the absolute CEP of both elliptically and linearly polarized light.

Li, Wen↗

Optical versus radiographic imaging and tomography: introduction to the ROADS feature issue

Optical imaging is an ancient branch of imaging dating back to thousands of years. Radiographic imaging and tomography (RadIT), including the first use of X-rays by Wilhelm Röntgen, and then, $γ$ -rays, energetic charged particles, neutrons, etc. are about 130 years young. The synergies between optical and radiographic imaging can be cast in the framework of these building blocks: Physics, Sources, Detectors, Methods, and Data Science, as described in Appl. Opt. 61, RDS1 (2022). Optical imaging has expanded to include three-dimensional (3D) tomography (including holography), due in to part the invention of optical (including infrared) lasers. RadIT are intrinsically 3D because of the penetrating power of ionizing radiation. Both optical imaging and tomography (OIT) and RadIT are evolving into even higher dimensional regimes, such as time-resolved tomography (4D) and temporarily and spectroscopically resolved tomography (4D + ). Further advances in OIT and RadIT will continue to be driven by desires for higher information yield, higher resolutions, and higher probability models with reduced uncertainties. Synergies in quantum physics, laser-driven sources, low-cost detectors, data-driven methods, automated processing of data, and artificially intelligent data acquisition protocols will be beneficial to both branches of imaging in many applications. These topics, along with an overview of the Radiography, Applied Optics, and Data Science virtual feature issue, are discussed here.

47 OTHER INSTRUMENTATION↗

Interface formation and Schottky barrier height for Y, Nb, Au, and Pt on Ge as determined by hard x-ray photoelectron spectroscopy

Development of a robust, thin, hole-blocking (n+) contact on high purity germanium (HPGe) has been the main challenge in the development of Ge-based radiation sensors. Yttrium has been reported to be a viable hole-blocking contact on HPGe, and detectors with low leakage have been fabricated. Niobium has also been considered as a potential hole-blocking contact due to its low work function. Here, we investigate interface chemistry and the Schottky barrier height of Y and Nb, as well as electron-blocking contacts Au and Pt, on Ge(100) surfaces using hard x-ray photoelectron spectroscopy. We find a barrier height of 1.05 ± 0.10 eV for Y/HPGe, confirming the formation of a hole-blocking barrier. For Nb/HPGe, the barrier height of 0.13 ± 0.10 eV demonstrates that the interface is not hole-blocking. The Schottky barrier of Au and Pt was found to be 0.45 ± 0.10 and 0.51 ± 0.10 eV, respectively.

36 MATERIALS SCIENCE↗

Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers

Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.

47 OTHER INSTRUMENTATION↗

Assessment of Blocking Contacts in Suppressing Polarization Effects in CsPbBr 3 Perovskite Detectors

The CsPbBr 3 perovskite has garnered significant attention as a room-temperature semiconductor for hard radiation detection due to straightforward synthesis, scalable crystal growth, low cost, and excellent energy resolution. However, despite these advantages, at ambient temperature, CsPbBr 3 devices may experience performance deterioration and irreversible failure due to “polarization” induced by electromigration of ions to electrical connections on the device. In this study, we tested several contact materials and their optimization deposition techniques to assess the stability of high-performance CsPbBr 3 γ-ray detectors. Metals, with low work functions (Ti, In, Sn, Sb, Pb, Bi, Al, Au, and TiC) and high-work-function (Au or Pt) contacts, were used to form different Schottky junctions using vacuum thermal evaporation, electron-beam evaporation, and sputtering methods. These detectors were tested in intermittent and continuous modes to assess their stability. Among the tested detectors, the Bi/CLB/Pt electrode configuration demonstrated superior stability, operating effectively for 11 months under periodic testing and 16 days under continuous testing. In contrast, other configurations functioned only for a few months under intermittent conditions. Upon incorporating a ~40-nm-thick TiC passivation layer on the anode side (Bi/TiC/CLB/Pt), the CLB device operated continuously for 36 days without degradation. In many cases, the failure mode of the devices was due to the degradation of the anode. Here, the chemical changes in the fresh and deteriorated anodes were characterized using scanning electron microscopy and energydispersive X-ray spectroscopy

CsPbBr3 perovskite↗

SALSA: a new versatile readout chip for MPGD detectors

The SALSA chip is a future readout ASIC foreseen for the MPGD detectors, developed in the framework of the EIC collider project, to equip the MPGD trackers of the EPIC experiment. It is designed to be versatile, to be adapted to other usages of MPGD detectors like TPC or photon detectors. It integrates a frontend block and an ADC for each of the 64 channels, associated to a configurable DSP processor meant to correct data and reduce the raw data flux to limit the output bandwidth. It will be compatible with the continuous readout foreseen for the EPIC DAQ, but will also work in a triggered environment. Several prototypes are already produced in order to qualify the different blocks of the chip, in particular the frontend, the ADC and the clock generation. The next 32-channel prototype is currently under development and is planed to be produced in 2025. In conclusion, the final prototype will be produced and tested from 2026 for a production of the SALSA chip at the horizon of 2027.

Data processing↗

Measuring Neutrino Oscillations in the NOvA and CHIPS Detectors.

NOvA is a long baseline neutrino experiment which uses muon neutrinos produced by the NuMI beam at the Fermi National Accelerator Laboratory to measure muon neutrino disappearance and electron neutrino appearance, among other analyses. The Far/Near Extrapolation analysis framework (FNEX) was used to measure muon neutrino disappearance using the events observed by NOvA while the NuMI beam was in Forward Horn Current configuration (i.e. this analysis uses neutrino data, not antineutrino data). The values of the parameters measured in this analysis are sin 2 θ 23 - 0.499$^{+0.098}_{-0.069}$ and Δm$^2_{32}$ - 2.454$^{+0.108}_{0.119}$ × 10 -3 eV, which is consistent with the results of NOvA’s main muon neutrino disappearance analysis using the experiment’s usual framework, known as CAF. The CHIPS detector is a water Cherenkov detector currently in construction. It will also use the NuMI beam to perform muon neutrino disappearance and electron neutrino appearance analyses. The necessary water clarity for a detector with a diameter of 25 m and a height of 6 m is discussed, as well as the results of testing water filtration systems. The filtration that will be used for the detector is a 10 µm carbon block filter and a 0.5 µm filter in series, with no reverse osmosis or ultraviolet sterilisation being used. This provides an attenuation length of 16.63 ± 0.25 m for light of 532 nm wavelength (green), so light with a wavelength of 405 nm (violet) would have an attenuation length of 133±2 m. The greatest possible distance between a PMT and any point in the detector’s volume is approximately 26 m, so 133 m is sufficient for the detector to measure Cherenkov light produced anywhere in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray and Particle Detection With the Si(Li) Tracker Module of the GAPS Experiment

Here, this work describes the architecture and the experimental results from the characterization of the lithium-drifted silicon (Si(Li)) detector module, which constitutes the building block of the tracker in the general antiparticle spectrometer (GAPS) experiment to search for dark matter. The instrument is designed for the identification of low-energy cosmic anti-nuclei (antiprotons, antideuterons, and antihelium) to be performed during an Antarctic long-duration balloon flight scheduled for late 2025. The GAPS Si(Li) tracker, that is the core of the instrument, is the assembly of 252 modules, each comprised of four Si(Li) detectors and a full custom-integrated circuit designed for detector readout and produced in a commercial 180-nm planar CMOS technology. A general overview of the detector module architecture and its components is provided, together with a description of the test setup and the experimental results obtained from the characterization of the low-noise analog readout channel. In order to verify the effective operation of the entire module, results concerning the detection of X-rays from a 241Am source and cosmic muons are also provided.

Manghisoni, Massimo [Università di Bergamo (Italy)↗

Experimental results from the characterization of a 32-channels mixed-signal processor for the GAPS experiment

This work describes the experimental results obtained from the characterization of a 32-channels readout ASIC that is the core of a module composed by 4 Lithium-drifted Silicon, Si(Li), detectors. The module is the building block of a tracker in an upcoming balloon experiment. The activity is carried out within the General AntiParticle Spectrometer (GAPS) international collaboration, whose objective is the indirect detection of dark matter through the detection of antiparticles present in cosmic rays at low energies. The balloon flight is foreseen in 2024 from the McMurdo station in Antarctica. The ASIC is designed in a 180 nm CMOS technology and has 32 low-noise analog readout channels featuring a dynamic compression of the signal, an 11-bit SAR ADC, and a digital back-end section responsible for channel setting and for sending digital information to the data acquisition system of the tracker. This work has a twofold goal: it intends on the one hand to verify the performance of the circuit, on the other to select at least 300 good samples to be used for the assembly of the GAPS Si(Li) tracker.

Riceputi, Elisa↗

The Role of Metal-Semiconductor Interface in Hybrid Perovskite Devices for High-Performance Radiation Photon Counting

Halide perovskites are promising optoelectronic semiconductors. For applications in solid-state detectors that operate in low photon flux counting mode, blocking interfaces are essential to minimize the dark current noise. Here, we investigate the interface between methylammonium lead tri-iodide (MAPbI 3 ) single crystals and commonly used high and low work function metals to achieve photon counting capabilities in a solid-state detector. Using scanning photocurrent microscopy, we observe a large Schottky barrier at the MAPbI 3 /Pb interface, which efficiently blocks dark current. Moreover, the shape of the photocurrent profile indicates that the MAPbI 3 single-crystal surface has a deep fermi level close to that of Au. Rationalized by first-principle calculations, we attribute this observation to the defects due to excess iodine on the surface underpinning emergence of deep band-edge states. The photocurrent decay profile yields a charge carrier diffusion length of 10–25 μm. Using this knowledge, we demonstrate a single-crystal MAPbI 3 detector that can count single γ-ray photons by producing sharp electrical pulses with a fast rise time of <2 μs. Overall, our study indicates that the interface plays a crucial role in solid-state detectors operating in photon counting mode.

36 MATERIALS SCIENCE↗

Electrical performances of pre-production staves for the ATLAS ITk Strip Detector Upgrade

The ATLAS experiment is currently preparing for an upgrade of the inner tracking detector for the High-Luminosity LHC. The new tracker, ITk, employs an all-silicon detector with outer strip layers. The building block of the ITk strip barrel is the stave which consists of a low-mass support structure hosting the common electrical, optical and cooling services as well as 28 silicon modules. In this contribution, we outline the challenging aspects of the stave pre-production testing phase at Brookhaven National Laboratory. Here, the electrical characterization of these staves, hosting the final design of all ASICs, will be discussed in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First results from search for muon-neutrino disappearance at ICARUS

The ICARUS collaboration has completed a search for muon-neutrino disappearance in the context of the 3+1 sterile neutrino model using data collected with the Booster Neutrino Beam at Fermilab during 2022-2023 (ICARUS Run 2). Events are reconstructed with two different reconstruction frameworks and we select events with 1 muon, at least 1 proton, and no pions in the final state. A new fitting framework, called PROfit, was developed for this analysis and used for the final results presented here. As a single detector oscillation search this analysis is systematics limited, but the tools shown here will serve as a building block for future SBN searches where systematics will be constrained by the addition of a near detector. I will discuss the details of the analysis with a focus on the fitting framework, mock data studies, and the final fitting procedure during the data unboxing.

Larkin, Jacob [Rochester U.]↗

First results from search for muon-neutrino disappearance at ICARUS

The ICARUS collaboration has completed a search for muon-neutrino disappearance in the context of the 3+1 sterile neutrino model using data collected with the Booster Neutrino Beam at Fermilab during 2022-2023 (ICARUS Run 2). Events are reconstructed with two different reconstruction frameworks and we select events with 1 muon, at least 1 proton, and no pions in the final state. A new fitting framework, called PROfit, was developed for this analysis and used for the final results presented here. As a single detector oscillation search this analysis is systematics limited, but the tools shown here will serve as a building block for future SBN searches where systematics will be constrained by the addition of a near detector. I will discuss the details of the analysis with a focus on the fitting framework, mock data studies, and the final fitting procedure during the data unboxing.

Larkin, Jacob [Rochester U.]↗

Updated Godiva-IV Benchmark Preview

A note of errata prepended to the Godiva-IV delayed-critical benchmark (HEU-MET-FAST- 086) identifies two corrections to be made to the model: The glory hole in the spindle should be made larger, and the height of the safety block should be made smaller (and therefore its density made larger). In addition, the safety block at its full-in position is closer to the inner subassembly plate than was modeled in the benchmark. These changes have been made to HEU-MET-FAST-086 Case 4 in order to estimate the effect on $\kappa$ eff and on the neutron flux spectrum. Using smaller separation, a smaller safety block, and a larger glory hole caused keff to increase by 453 ± 1 pcm from the benchmark. The latest nuclear data, ENDF/B-VIII.0, have also been used, causing $\kappa$ eff to increase another 37 ± 1 pcm. Flux spectra were compared in a modeled fission foil (near the center of Godiva-IV in the glory hole) and at three external (point) detectors. Within the fission foil, using ENDF/B-VIII.0 induced changes in the flux spectrum similar in size to the changes due to using smaller separation, a smaller safety block, and a larger glory hole. At the detectors, using ENDF/B- VIII.0 induced changes in the flux spectrum much larger than those due to changing the model. In other words, the corrections to the benchmark model cause a large increase in $\kappa$ eff , but the changes to the neutron flux spectrum are small compared to those caused by using the latest nuclear data. This study presents a preview of results expected during the reevaluation of the Godiva IV benchmark, but it is not a substitute for the full reevaluation.A note of errata prepended to the Godiva-IV delayed-critical benchmark (HEU-MET-FAST- 086) identifies two corrections to be made to the model: The glory hole in the spindle should be made larger, and the height of the safety block should be made smaller (and therefore its density made larger). In addition, the safety block at its full-in position is closer to the inner subassembly plate than was modeled in the benchmark. These changes have been made to HEU-MET-FAST-086 Case 4 in order to estimate the effect on $\kappa$ eff and on the neutron flux spectrum. Using smaller separation, a smaller safety block, and a larger glory hole caused $\kappa$ eff to increase by 453 ± 1 pcm from the benchmark. The latest nuclear data, ENDF/B-VIII.0, have also been used, causing $\kappa$ eff to increase another 37 ± 1 pcm. Flux spectra were compared in a modeled fission foil (near the center of Godiva-IV in the glory hole) and at three external (point) detectors. Within the fission foil, using ENDF/B-VIII.0 induced changes in the flux spectrum similar in size to the changes due to using smaller separation, a smaller safety block, and a larger glory hole. At the detectors, using ENDF/B- VIII.0 induced changes in the flux spectrum much larger than those due to changing the model. In other words, the corrections to the benchmark model cause a large increase in $\kappa$ eff , but the changes to the neutron flux spectrum are small compared to those caused by using the latest nuclear data. This study presents a preview of results expected during the reevaluation of the Godiva IV benchmark, but it is not a substitute for the full reevaluation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗

Epoxy-based infrared filter assembly and associated fabrication devices and method

Epoxy-based inline infrared (IR) filter assembly, and manufacture and use of the same. Co-axial infrared filter assemblies comprise a substantially cylindrical filter body forming a central cavity characterized by opposing holes at each end. The filter body forms an outer conductor, and SMA connectors coupled to the opposing holes at each end of the body are electrically coupled to form an inner conductor positioned along a long axis of the filter body. An infrared absorbing material (such as castable epoxy resin) fills the central cavity of the filter body. Methods for producing the co-axial infrared filter include pressing SMA connectors into the respective ends of the filter body, electrically coupling the SMA connectors, and filling the filter body with epoxy. Electronic systems for operating a dark matter detector include a feedline comprising a coaxial filter configured to advantageously block infrared noise.

Spahn, Gabriel↗