Search NASA⌕ Search

SEARCH · Search NASA

Results for “boil-off”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Capture, storage, and re-use of liquid hydrogen boil-off for aviation and aerospace applications

Despite major interest in the use of liquid hydrogen as a fuel for aviation and aerospace sectors, loss of hydrogen through boil-off continues to be a hurdle as it causes financial loss, indirect greenhouse gas emissions, and safety concerns. Herein, we perform techno-economic analysis, calibrated with experimental measurements, to assess the use of sorbents to capture and condition hydrogen boil-off events in the range of 1.5 to 70 tonnes per day at launch sites and airports. We evaluate the direct delivery of captured boil-off to combustion engines and fuel cells, comparing against boil-off re-liquification and compression. Results indicate probable cost-effectiveness at delivered liquid hydrogen prices above 0.9 U.S. dollar ($) per kg H2 at airports, and above 10 $ per kg H2 at launch sites where 10% or more of hydrogen is lost to boil-off.

08 HYDROGEN↗

A 10,000-gpm liquid hydrogen transfer system for the Saturn/Apollo program.

Brief description of the design and operation of the liquid hydrogen transfer system used to service the Saturn V launch vehicle. The cryogenic loading of the huge booster begins eight hours before the scheduled liftoff. The first three hours of fueling are spent in cold hydrogen gas conditioning of the fuel tank. The cold hydrogen gas is provided by vaporizing liquid hydrogen from the storage tank and routing the resultant gas through the fill system. Boil-off losses after loading are continuously replaced through control valves which are driven by a computer system. The liquid hydrogen transfer system is made up of a number of subsystems including the 850,000 gal storage tank whose boil-off losses amount to only 200 gal/day, the pressurization system, the burn pond for controlled disposal of hydrogen waste gas, the storage tank fill manifold, and the hazardous gas monitoring system. Some of the subsystems and components are redundant to provide a high degree of reliability.

Wybranowski, E., Jr.↗

Characterization Testing of a 20 Kelvin Cryocooler for Space Applications

Future NASA space exploration missions will require long-duration storage and liquefaction of cryogenic liquids, enabled by active cooling provided by cryocoolers. Recent gap analyses of Lunar and Mars transportation systems have identified 20 K-class cryocoolers as a critical enabling technology for chemical and nuclear thermal propulsion architectures using liquid hydrogen propellant. To address this technology gap, NASA has undergone the development of a high-efficiency, high-capacity 20 K cryocooler via an SBIR partnership with Creare. While the January 2025 testing demonstrated functionality and compliance with contractual requirements, the objective of the NASA-led characterization effort was to generate a dataset for supporting future mission designs across a broader operating envelope, including off-nominal conditions. The cryocooler demonstrated strong performance, achieving a peak coefficient of performance of 17.68% relative to Carnot efficiency and a maximum lift capacity of 24.4 W at 21 K. Overall, the results confirm that the 20 W 20 K cryocooler provides a flexible range of capabilities to enable zero boil-off storage of liquid hydrogen for future Lunar and Mars missions. The data collected provide a strong foundation for model validation and future system design efforts.

Cryocooler↗

Characterization Testing of a 20 Kelvin Cryocooler for Space Applications

Future NASA space exploration missions will require long-duration storage and liquefaction of cryogenic liquids, enabled by active cooling provided by cryocoolers. Recent gap analyses of Lunar and Mars transportation systems have identified 20 K-class cryocoolers as a critical enabling technology for chemical and nuclear thermal propulsion architectures using liquid hydrogen propellant. To address this technology gap, NASA has undergone the development of a high-efficiency, high-capacity 20 K cryocooler via an SBIR partnership with Creare. While the January 2025 testing demonstrated functionality and compliance with contractual requirements, the objective of the NASA-led characterization effort was to generate a dataset for supporting future mission designs across a broader operating envelope, including off-nominal conditions. The cryocooler demonstrated strong performance, achieving a peak coefficient of performance of 17.68% relative to Carnot efficiency and a maximum lift capacity of 24.4 W at 21 K. Overall, the results confirm that the 20 W 20 K cryocooler provides a flexible range of capabilities to enable zero boil-off storage of liquid hydrogen for future Lunar and Mars missions. The data collected provide a strong foundation for model validation and future system design efforts.

Zero boil-off↗

[LCA UP] LNG Ocean Shipping

This unit process includes operation of a liquefied natural gas (LNG) ocean tanker using steam, DFDE/TFDE, ME-GI or X-DF engines. The tanker is fueled by a combination of boil-off gas (BOG) produced via evaporation of LNG, fuel oil, and diesel.

Group - Transport Process; LCA; LCA Unit Process; ↗

An Overview of Potential Future Aviation Energy Carriers

Global jet fuel demand is projected to grow to 165 billion gallons by 2050 and there is growing interest in the aviation industry to understand the capabilities of alternative energy carriers. This report considers several potential energy carriers, reviewing their production potential, operational considerations, and economic implications to inform potential next steps in aeronautics research. The following energy carriers (i.e., fuels) were evaluated in this study for future use in aviation: sustainable aviation fuel (SAF) - both biomass-based and power-to-liquids (PtL) - based SAF - cryogenic hydrogen (LH 2 ) - also known as liquid hydrogen - liquefied natural gas (LNG), liquefied ethane (LE), and Jet X. The barriers and opportunities for the evaluated energy carriers vary. SAF is a commercially available drop-in fuel compatible with existing aircraft and infrastructure. SAF is limited by both higher prices and slow commercialization of multiple pathways using different feedstocks necessary to significantly grow supply. Cryogenic fuels, in contrast, have very different thermal, physical, and chemical properties than SAF and Jet A, requiring the construction of new airport storage and dispensing infrastructure and the design of new aircraft energy systems capable of mitigating heat transfer and boil-off. Cryogenic fuels offer an opportunity to diversify aviation fuel carriers from domestic energy relevant for both energy security and resilience. This means cryogenic fuels are more of a longer-term solution for aircraft but are worth exploring for potential future cost savings and emissions benefits. Jet X refers to non-drop-in liquid hydrocarbon fuels in the early stages of investigation seeking favorable properties. There are substantial barriers to non-drop-in liquid aviation fuels that are not compatible with existing aircraft and fuel infrastructure.

33 ADVANCED PROPULSION SYSTEMS↗

Helium recovery system at IB3A

The growing demand for sustainable cryogenic operations at Fermilab has underscored the need to improve helium management, particularly at the Industrial Building 3A (IB3A) test facility. IB3A characterizes and tests superconductors, cables, and coils for projects such as the HL-LHC AUP and Mu2e, yet currently relies on 500 L Dewars whose boil-off is vented to atmosphere, wasting a critical, non-renewable resource and increasing the cost of testing. A project is therefore under way to link IB3A to an existing purification and liquefaction station in a neighboring building through a dedicated pipeline. Captured helium will be transferred, purified, reliquefied, and returned for reuse, cutting losses and operating costs. This paper details the first two project phases: "Design and Engineering" and "Procurement and Installation." The design phase finalizes pipeline specifications, establishes flow-control requirements, and resolves integration challenges with existing cryogenic infrastructure. The procurement and installation phase covers material sourcing, pipeline construction, and deployment of control and monitoring systems to assure reliable, efficient operation. Key technical hurdles-route optimization, pressure drop mitigation, and interface compatibility-are discussed alongside implemented solutions. Implementing the pipeline and upgrading IB3A will dramatically reduce helium consumption and therefore testing cost, strengthening Fermilab's capacity to support frontier science far into the future.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗

Cryogenic storage on the moon.

Cryogenic fluid storage on moon surface, considering Lambert reflection law, thermal insulation performance, incident heat flux and boil-off rates

LUNAR SURFACE↗

Cryogenic storage on the moon.

Cryogenic fluid storage on moon surface, considering Lambert reflection law, thermal insulation performance, incident heat flux and boil-off rates

Gabron, F.↗

Performance of a 12-coil superconducting bumpy torus magnet facility

The bumpy torus facility consists of 12 superconducting coils, each 19 cm i.d. and capable of 3.0 teslas on their axes. The coils are equally spaced around a toroidal array with a major diameter of 1.52 m, and are mounted with the major axis of the torus vertical in a single vacuum tank 2.6 m in diameter. Final shakedown tests of the facility mapped out its magnetic, cryogenic, vacuum, mechanical, and electrical performance. The facility is now ready for use as a plasma physics research facility. A maximum magnetic field on the magnetic axis of 3.23 teslas was held for a period of more than sixty minutes without a coil normalcy. The design field was 3.00 teslas. The steady-state liquid helium boil-off rate was 87 liters per hour of liquid helium without the coils charged. The coil array was stable when subjected to an impulsive loading, even with the magnets fully charged. When the coils were charged to a maximum magnetic field of 3.35 teslas, the system was driven normal without damage.

Roth, J. R.↗

Characteristics of a gelled liquid hyprogen polyphenylene oxide (PPO) foam open-cell insulation system, phase 1

A large scale gel production and storage facility and a small scale facility, the latter used for detailed visual examination of the gel/PPO foam interface, were developed. A subcontract was given to investigate techniques for the production of gelled liquid hydrogen, develop a process design for scale-up to a 1.89 cu m (500 gallon) gel production and storage facility, determine gel transfer characteristics, determine the solubility rate of gaseous helium in the gel, and investigate the gross gel/PPO foam interfacial phenomena. An inside-tank process for scaled-up production of gelled liquid hydrogen was selected. No detectable gel structure degradation occurred during repeated shearing. The viscosity of gelled liquid hydrogen at shear rates of 300/sec and higher is 2 to 5-fold greater than that of neat liquid hydrogen. No clogging problems were encountered during the transfer of gelled liquid hydrogen through warmed transfer lines. The solubility rate of helium in liquid hydrogen was significantly reduced by the presence of gel structure. The boil-off rates from gelled liquid hydrogen were reduced from 25 to 50 percent compared to those observed for the neat liquid hydrogen under compatible conditions. The polyphenylene oxide (PPO) foam insulation was found to be compatible with liquid ethane.

Source record↗

Performance characteristics of the U.VA. superconducting wind tunnel balance

Initial operational characteristics of a wind tunnel electromagnetic balance utilizing superconducting coils are reported. Both dc and ac superconducting coils are used for balancing and measuring 3-component aerodynamic forces on simple models in Mach 3, room temperature flow. Liquid helium boil-off measurements corresponding to a wide range of operating conditions are presented together with results of systematic ac losses scaling experiments using various pancake coils wound with superconducting tape. This unique prototype facility is primarily for studying the practical feasibility of using superconducting magnetic suspension techniques for aerodynamic testing and accumulating the knowledge and expertise required for extrapolating these techniques to large-scale facilities.

Humphris, R. R.↗

Cryogenic storage tank thermal analysis

Parametric study discusses relationship between cryogenic boil-off and factors such as tank size, insulation thickness and performance, structural-support heat leaks and use of vapor-cooled shields. Data presented as series of nomographs and curves.

Wright, J. P.↗