Search NASA⌕ Search

SEARCH · Search NASA

Results for “bolometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

3D radiated power analysis of JET SPI discharges using the Emis3D forward modeling tool

Abstract Precise values for radiated energy in tokamak disruption experiments are needed to validate disruption mitigation techniques for burning plasma tokamaks like ITER and SPARC. Control room analysis of radiated power ( P rad ) on JET assumes axisymmetry, since fitting 3D radiation structures with limited bolometry coverage is an under-determined problem. In mitigated disruptions, radiation is toroidally asymmetric and 3D, due to fast-growing 3D MHD modes and localized impurity sources. To address this problem, Emis3D adopts a physics motivated forward modeling (‘guess and check’) approach, comparing experimental bolometry data to synthetic data from user-defined radiation structures. Synthetic structures are observed with the Cherab modeling framework and a best fit chosen using a reduced χ 2 statistic. 2D tomographic inversion models are tested, as well as helical flux tubes and 3D MHD simulated structures from JOREK. Two nominally identical pure neon shattered pellet injection (SPI) mitigated discharges in JET are analyzed. 2D tomographic inversions with added toroidal freedom are the best fits in the thermal quench (TQ) and current quench (CQ). In the pre-TQ, 2D reconstructions are statistically the best fits, but are likely over-optimized and do not capture the 3D radiation structure seen in fast camera images. The next-best pre-TQ fits are helical structures that extend towards the high-field side, consistent with an impurity flow under the magnetic nozzle effect also observed in JOREK simulations. Whole-disruption radiated fractions of 0.98 + 0.03 / − 0.29 and 1.01 + 0.02 / − 0.17 are found, suggesting that the stored energy may have been fully mitigated by each SPI, although mitigation efficiencies well below ITER and SPARC requirements for high energy pulses are still within the large uncertainties. Emis3D is also used to validate JOREK SPI simulations, and confirms improvements in matching experiment from changes to impurity modeling. Time-dependent toroidal peaking factors are calculated and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and implementation of a prototype infrared video bolometer (IRVB) in MAST Upgrade

A prototype infrared video bolometer (IRVB) was successfully deployed in the Mega Ampere Spherical Tokamak Upgrade (MAST Upgrade or MAST-U), the first deployment of such a diagnostic in a spherical tokamak. The IRVB was designed to study the radiation around the lower x-point, another first in tokamaks, and has the potential to estimate emissivity profiles with spatial resolution beyond what is achievable with resistive bolometry. The system was fully characterized prior to installation on MAST-U, and the results are summarized here. After installation, it was verified that the actual measurement geometry in the tokamak qualitatively matches the design; this is a particularly difficult process for bolometers and was done using specific features of the plasma itself. The installed IRVB measurements are consistent both with observations from other diagnostics, including magnetic reconstruction, visible light cameras, and resistive bolometry, as well as with the IRVB-designed view. Early results show that with conventional divertor geometry and only intrinsic impurities (for example, C and He), the progression of radiative detachment follows a similar path to that observed for large aspect ratio tokamaks: The peak of the radiation moves along the separatrix from the targets to the x-point and high-field side midplane with a toroidally symmetric structure that can eventually lead to strong effects on the core plasma inside the separatrix.

47 OTHER INSTRUMENTATION↗

Power balance and divertor asymmetries in the Super-X divertors of MAST-U using SOLPS-ITER

Spherical tokamaks (STs) present unique challenges and opportunities in the area of particle and power exhaust, intensified due to their more compact sizes. Substantial efforts are underway in STs to determine the limits in dissipative operational regimes and advanced divertor solutions, including at MAST-U which provides access to the Super-X divertor configuration. Power balance, and upper/lower divertor asymmetries have been studied using SOLPS-ITER simulations of the MAST-U Super-X divertor. A set of simulations with experimentally inferred transport coefficients with E x B and diamagnetic drifts activated, consisting of density and power scans, and high field side vs low field side gas puff locations, have been used for code experimentation to uncover trends beyond the current experimental parameter space. The upper biased asymmetry (U:L > 1) of the ratio of the peaks of the plasma energy flux densities at the outer targets increases with heating power and decreases with gas puff strength, going from symmetric to up to a factor of 15. The upper target electron temperature has been found to be a good ordering quantity for the magnitude of this asymmetry for all heating powers, gas puff strength, and gas puff locations. The lower divertor biased asymmetry (U:L < 1) of the radiation patterns processed through SOLPS-based bolometry synthetic diagnostics is in qualitative agreement with resistive bolometry experimental results, and it is in quantitative agreement with the trend of the total volume radiation within the divertors of SOLPS. However, radiation measurements alone are not sufficient to infer the magnitude of the asymmetry of the peaks of the power loads at the targets.

MAST-U↗

Analysis of fast-ion losses measured in MAST-U via infrared thermography and a Fast Ion Loss Detector

Fast-ion losses need to be monitored to avoid damage to plasma facing components. In existing experimental devices, the scintillator-based fast-ion loss detector (FILD) is the most advanced diagnostic for measuring fast-ion losses. However, FILDs provide only local information about the losses. Infrared (IR) thermography can be used as a complementary tool for more global monitoring of the deposition of fast-ion losses on the wall, at the expense of no velocity-space resolution. IR cameras measure the temperature of the plasma facing components. This measurement, determined by a combined effect of the thermal plasma, radiation, neutrons and fast-ion losses, can be decomposed to infer the fast-ion load on the tokamak wall. In this manuscript, a workflow to estimate fast-ion losses via IR thermography is applied to the MAST-U spherical tokamak, using a 1D approximation to extract the experimental heat flux on the FILD front face from IR data. To numerically estimate the different contributions to this total heat flux, the field-line tracing environment SMITER is used to calculate the thermal plasma contribution, the orbit-following Monte-Carlo code ASCOT to estimate the fast-ion losses, and bolometry measurements for the radiation. To validate the workflow, two discharges, L-mode plasmas with low MHD activity, were executed using on and off-axis beams, respectively. The experimentally and numerically estimated heat flux are of the same order of magnitude for the on-axis heated scenario, with a strong dependence of the estimated fast-ion losses contribution on the fit to the kinetic profiles used as input. This is also true for the off-axis heated scenario, where the total numerically estimated heat flux is 2.1 or 1.3 times higher than the maximum experimentally estimated heat flux, depending on the ASCOT input used.

FILD↗

Methods to determine the radiated power in SPI-mitigated disruptions in JET

Here we present techniques for evaluating the radiated power in JET disruptions. Disrupting plasmas are shown to have non-axisymmetric radiation profiles, motivating the re-evaluation of the standard techniques for calculating the total radiated power at JET using bolometry. Four single-channel bolometers at different toroidal locations are exploited to quantify the radiation asymmetry. Toroidal radiation peaking factors integrated over the entire disruption of up to 1.5 have been observed when varying the quantity of neon in pellets used in disruptions mitigated by shattered pellet injection. Using synthetic bolometer diagnostics developed with the Cherab spectroscopy modeling framework, we can estimate the systematic error on total power calculations for relevant radiation profiles and improve estimates of the total radiated power. We show that the component of the systematic error on the total power due to the poloidal radiation profile can be reduced from 70% to 10% with suitable assumptions about the structure of the poloidal profile.

47 OTHER INSTRUMENTATION↗

Thermal energy mitigation and toroidal peaking effects in JET disruptions

Previous investigations on JET suggest half or less of plasma stored thermal energy W th is radiated (f rad,th ≲ 0.5) using either massive gas injection (MGI) or shattered pellet injection (SPI) disruption mitigation. We investigate whether the apparent incomplete f rad,th is explained by radiation peaking near the injection plume. High toroidal peaking throughout the pre-thermal quench is found in argon–deuterium MGI on JET, with typically >3× higher radiation near the injector than toroidally distant. Previously unexplained toroidal bolometry measurements in neon–deuterium SPI are reproduced with similar peaking using the Emis3D radiation analysis code. These observations align with results from Alcator C-Mod and KSTAR. This peaking is not captured by previous JET studies that found poor thermal mitigation. Two sets of neon–deuterium SPI and two sets of argon–deuterium MGI are analyzed using Emis3D. In SPI, f rad,th rises from no-plume estimates of 0.31 and 0.66 to lower bounds of 0.84 and 0.92, respectively, and f rad,th ∼ 1 is possible. In MGI, the toroidal spread of the peaking feature is poorly constrained. f rad,th up to 0.85 and 0.65 are possible using the largest possible spread, increasing from 0.42 and 0.28, although f rad,th ∼ 1 does not appear to be reached. Revised mitigation estimates on JET suggest a lower melt risk to the divertor in mitigated disruptions on ITER and SPARC than previously thought. However, peaking near injectors could increase flash melting risk on nearby plasma facing components.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effect of ICRH and NBI on tungsten transport in neon edge radiation cooled discharges in TEXTOR

Tungsten is planned to be the plasma-facing material for the main chamber and divertor in future devices like ITER, SPARC, and DTT. To address risks associated with tungsten, R&D is being carried out on various toroidal confinement devices. One particular research question is related to the optimum heating mix for ITER. To investigate the influence of the heating scheme on the release and transport of tungsten, a comparison of neutral beam injection (NBI) and ion cyclotron resonance frequency (ICRF) heating was carried out in TEXTOR tungsten test limiter experiments. The experiments were performed under standard L-mode conditions and in radiative improved-mode operation with neon seeding and boronized walls covering the graphite plasma-facing components. The plasma was heated with hydrogen or deuterium NBI alone or with deuterium NBI in combination with H-minority, ion cyclotron resonance heating. A movable solid tungsten limiter was inserted through a limiter lock system into the edge plasma. The impurity release from this limiter was evaluated from visible spectroscopy. The tungsten concentrations in the plasma core were determined by extreme ultraviolet spectroscopy and bolometry. With deuterium NBI alone, strong central radiation and accumulation of W was observed. This can, however, be avoided by adding ICRF heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of near- and far-field impurity flows during pellet-induced rapid shutdown in DIII-D

Both near-field (<1 m away toroidally from the pellet) and far-field (>1 m away toroidally from the pellet) poloidal and toroidal impurity (carbon ion) flows are measured using visible imaging and fast bolometry during a polypropylene pellet-induced rapid plasma shutdown in the DIII-D tokamak. In the near field, the pellet appears to increase poloidal flow in the ion diamagnetic direction, possibly due to the strong radial temperature gradient caused by the pellet ablation. In the far field, the poloidal impurity flow typically appears slower and in the opposite direction. Toroidal impurity flow appears to be strongly influenced by the plasma initial toroidal rotation, especially in the far field. These results demonstrate that rapid shutdown impurity flows are not necessarily global in structure but can be quite different close to and far from the injected pellet.

Electromagnetic radiation detectors↗

Gyrokinetic prediction of core tungsten peaking in a WEST plasma with nitrogen impurities

Tungsten peaking is predicted in the core of a WEST plasma with total-f gyrokinetic simulations, including both collisional and turbulent transport. This prediction is validated with a synthetic diagnostic of the bolometry. Although nitrogen impurities are shown to reduce the neoclassical peaking of tungsten on-axis, the overall tungsten peaking increases when nitrogen impurities are present, as they reduce the turbulence screening off-axis. This finding is important for the plasma current ramp-up phase of ITER, where light impurities seeding will be desirable to achieve low temperatures at the plasma-facing components and reduce tungsten sputtering. It provides further argument for applying early ECRH heating to maintain margins on the core power balance. The neoclassical peaking factor is cross-verified between XGC and FACIT. The heat flux at separatrix and the heat load width are modeled by XGC and compared to WEST data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of plasma start-up with high Z and low Z first wall in WEST

The choice of first wall material is of paramount importance for the plasma start-up conditions in ITER and future fusion power plants. In this context, the present work focuses on the correlations between first wall impurity sources and total radiated power during plasma start-up in the tungsten (W) Environment in Steady-state Tokamak (WEST). The objective is to highlight experimental indications for a preferable combination of start-up plasma scenario and first wall materials. Until 2019, WEST featured a full high Z first wall with all limiters exposing only W surfaces to the plasma. To study the impact of a low Z first wall in WEST, boron nitride tiles were installed in the central part of the inner and outer limiters in 2020. Although visible spectroscopy and bolometry measurements show respectively a strong weakening of the WI line intensity on the limiters and a reduction of radiated power after the changeover, a degradation occurs with the accumulation of plasma exposure. In addition, the different plasma facing elements of the main chamber do not influence equally the radiated power during start-up. In both high Z and low Z environments, a clear non-linear dependence is found between the start-up radiated power and the outer limiter W impurity source. Since W seems to be the main cause for core radiation, correlation between outer limiter W sources and other impurity sources are investigated. Finally, analysis of the legacy of B powder drops on a number of start-up plasmas suggests that it is less effective at reducing radiated power when the first wall is covered with W.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of 3D MHD simulations of Ne/D 2 mixed shattered pellet injection in JET

Nonlinear 3D magnetohydrodynamic (MHD) modeling of shattered pellet injection (SPI) in JET tokamak plasmas is performed with the JOREK code. The study focuses on the validation of simulation result with respect to experimental observations, addressing in particular figures of merit for the efficiency of the SPI, as a technique to mitigate thermal loads by injecting radiative impurities like neon during the thermal quench (TQ) phase of disruptions. A set of JET pulses with neon/deuterium atomic mixture ratio in the shattered pellet varying from 10% to 100% provides the experimental data to be compared with. Simulations using different models for the ablation of solid fragments and the radiation of neon impurities are considered. Synthetic diagnostics are employed for a direct quantitative comparison with key JET diagnostic systems providing in particular radiation, electron temperature and density, and magnetic measurements. 3D radiation structures from MHD simulations are analyzed to estimate the toroidal asymmetry of radiation, which is difficult to measure in JET due to the presence of only two toroidally displaced multi-channel bolometry systems. JOREK simulations show that, before the TQ, the bulk of the radiation is concentrated in a toroidal region enclosing the radiating fragments that is missed by both multi-channel bolometers, suggesting a possible underestimation of the total radiation by such diagnostic systems in the pre-TQ phase. On the other hand, JOREK predicts that during the TQ the radiation becomes more toroidally symmetric, with positive implications for the heat load to plasma facing components.

JOREK↗

Radiation-front position control with scenario adjustments during the first tungsten divertor operation on KSTAR

This study reports the first experimental demonstration of a radiation front-based detachment control system during the initial tungsten divertor campaign in KSTAR. The system employs real-time infrared video bolometry with tomographic reconstruction to track the inboard radiation-front position, which served as a feedback variable for impurity seeding. In a baseline scenario without pre-D 2 fueling, tungsten accumulation triggered core radiation surges and repetitive H–L back transitions. In contrast, with pre-D 2 fueling, detachment was stabilized by maintaining higher edge-localized mode frequency, suppressing core tungsten buildup, and reducing sputtering, thereby enabling sustained feedback control. The suitability of the inboard front position as a detachment control metric was confirmed by its correlation with the degree of detachment: with D 2 fueling the relation exhibited a broad hysteresis loop characteristic of momentum-loss-dominated detachment, whereas with N 2 fueling, it became narrow and nearly vertical, consistent with radiation-loss-dominated pinning. These results provide a proof-of-principle for radiation-front-based detachment control, demonstrating its viability as a control approach. At the same time, these results clarify that the detachment outcomes were further conditioned by impurity transport characteristics of tungsten divertor operation in KSTAR, providing guidance for future scenario optimization and controller development in tungsten devices.

KSTAR↗

Modelling the limiter ramp-up of WEST for addressing the future challenges of ITER

This paper presents a joint experimental and numerical investigation into the physics of long limited plasma ramp-up in tokamaks with tungsten (W) first walls, a critical phase for ITER operation. The comparison between the average plasma quantities simulated using the SolEdge-HDG code and the measurements taken during three successive WEST discharges after boronisation shows how challenging it is to predict this phase. While simulations reproduce the general trends at the midplane, with reasonable match in density profiles, they consistently underestimate core temperatures possibly due to too large perpendicular heat conductivity. On the contrary, at the high field side (HFS) limiter, simulations overestimate the measured quantities, and highlights the limitation of using Bohm boundary conditions at grazing magnetic angles. Experimental measurements reveal that the boron layer is rapidly eroded, on a timescale comparable to a single ITER discharge. The subsequent transition from a boron-coated to a tungsten wall increases recycling and significantly degrades the core plasma, reducing the electron temperature by nearly half due to W contamination, despite wall parameters remaining stable. Furthermore, comparisons with Langmuir probes, bolometry, reflectometry, and spectroscopy indicate that the experimental far scrape-Off layer (SOL) is significantly wider than simulated. This wide SOL implies that boron erosion extends along the entire HFS limiter rather than being confined to the contact point. This work highlights some characteristics of the plasma during this phase of the discharge and emphasizes the current modelling issues that need to be resolved in order to obtain reliable predictions concerning the ITER ramp-up.

ITER↗

First lower hybrid current drive experiments on the WEST tokamak

The first lower hybrid current drive experiments in the full tungsten WEST tokamak are reported. Good wave coupling is found at rather low plasma current (q 95 ~4.3) and medium density (n e ~3×10 19 m -3 ). Reflection coefficient is in agreement with the expectation from the linear theory of coupling. With low reflection coefficients, 5MW was coupled for 2 seconds. High central electron temperature, up to 5keV, is achieved at ne = 3-4×10 19 m -3 . Flat and even hollow profiles of tungsten density are derived from the bolometry diagnostic. The stored thermal energy follows the H96-P scaling law with very slight degradation with density. The current drive efficiency has been assessed in low loop voltage (V L ~0.15V) discharges. Low plasma current operation and rather high effective charge (Z eff ~3) lead to modest current drive efficiency (η = 0.5-0.65 × 10 19 A.W -1 m -2 ). Long pulse operation (~30s) with high LHCD power (P LH =2.7MW) is achieved with stationary parameters, in particular electron and impurity densities, with the upper water-cooled tungsten divertor.

Goniche, M.↗

Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

42 ENGINEERING↗

Fiber-optic bolometer with low detection limit fabricated using thermal release tape and precise laser heating

Fiber-optic bolometers (FOBs) based on a fiber-tipped silicon Fabry–Perot (FP) interferometric temperature sensor and a gold disk absorber have been shown to be an attractive alternative to conventional resistive bolometers for plasma radiation measurement in fusion devices. Either a high-finesse FP or a low-finesse FP can be used, each with trade-offs between noise performance and fabrication complexity. In this paper, we present an FOB design that overcomes these limitations by combining a low-finesse long silicon FP cavity with a large gold disk absorber to achieve enhanced sensitivity and noise performance without increasing the fabrication complexity and the time constant. We also demonstrated a fabrication method for the sensor head facilitated by thermal release tape and precise laser heating. Our FOB demonstrates a temperature resolution of 0.08 mK, a cooling time constant of 230 ms, and a noise equivalent power density of 0.015 W m −2 . This represents an eightfold improvement over previous high-finesse FOBs and 26-fold improvement over previous low-finesse FOBs with similar demodulation bandwidths and similar cooling time constants.

Fabry–Perot interferometer↗