Search NASA⌕ Search

SEARCH · Search NASA

Results for “boron scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Boronated Scintillator Detector of the ISS-CREAM Experiment

The Cosmic Ray Energetics And Mass for the International Space Station (ISS-CREAM) instrument is a next-generation experiment for the direct detection and study of cosmic-ray nuclei and electrons. With a long exposure in low Earth orbit, the experiment will determine the particle fluxes and spectral details of cosmic-ray nuclei from hydrogen to iron, over an energy range of about 10(exp 12) eV to > 10(exp 15) eV, and of cosmic-ray electrons over an energy range of about 5x10(exp 10) eV to > 10(exp 13) eV. The instrument was deployed to the ISS in August 2017 on the SpaceX CRS-12 mission. We review the design, implementation and performance of one of the ISS-CREAM detector systems: a boron loaded scintillation detector used in discriminating electron-induced events from the much more abundant cosmic-ray nuclei.

Y Amare↗

Gated-Dynode Photomultiplier Tube Assembly for the Boronated Scintillator Detector of the ISS-CREAM Experiment

We present the design of a four-photomultiplier tube (PMT) assembly for measuring light generation in theBoronated Scintillator Detector (BSD) of the Cosmic Ray Energetics And Mass experiment for the InternationalSpace Station (ISS-CREAM). The light produced in the scintillator includes a contribution from the captureof thermalized neutrons produced in cosmic ray interactions, as well as delayed fluorescence, in the range ofseveral microseconds following the incident cosmic ray impact. The BSD is held in an insensitive state until acosmic-ray trigger causes a rapid turn on of the PMTs to detect late light signals, several microseconds afterthe trigger. The design includes two pulsed high-voltage supplies, which serve to gate the first two dynodesof the Hamamatsu R1924A PMTs used in the assembly. When the dynode gates are held in the "off" state,this scheme is shown to suppress >105 photons from injection into the tube's multiplier stage, while beingcapable of rapid switching into a stable operating mode in less than 1 s. This mitigates any backgroundsfrom afterpulsing that might otherwise be present in the PMT response following the cosmic ray incidence.

Anderson, T.↗

Light output and neutron detection efficiency of boron-based neutron scintillator screens for neutron imaging

Recent research has explored the development of boron-based neutron scintillator screens, which potentially offer improved spatial resolution and neutron capture efficiency compared to traditional lithium-based screens. This work builds upon previous efforts to improve boron-based neutron scintillators by assessing a newer generation of boron-based scintillator screens fabricated using different compositions and fabrication approaches compared to previous generations of screens. Some of the test screens exhibit higher light output than previous efforts and higher neutron capture efficiency than lithium-based screens. This paper describes the current state of screen development, measurement results for the most recent generation of screens, and future activities.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Boron-Based Neutron Scintillator Screens for Neutron Imaging

In digital neutron imaging, the neutron scintillator screen is a limiting factor of spatial resolution and neutron capture efficiency and must be improved to enhance the capabilities of digital neutron imaging systems. Commonly used neutron scintillators are based on 6 LiF and gadolinium oxysulfide neutron converters. This work explores boron-based neutron scintillators because 10 B has a neutron absorption cross-section four times greater than 6Li, less energetic daughter products than Gd and 6 Li, and lower γ-ray sensitivity than Gd. These factors all suggest that, although borated neutron scintillators may not produce as much light as 6 Li-based screens, they may offer improved neutron statistics and spatial resolution. This work conducts a parametric study to determine the effects of various boron neutron converters, scintillator and converter particle sizes, converter-to-scintillator mix ratio, substrate materials, and sensor construction on image quality. The best performing boron-based scintillator screens demonstrated an improvement in neutron detection efficiency when compared with a common 6 LiF/ZnS scintillator, with a 125% increase in thermal neutron detection efficiency and 67% increase in epithermal neutron detection efficiency. The spatial resolution of high-resolution borated scintillators was measured, and the neutron tomography of a test object was successfully performed using some of the boron-based screens that exhibited the highest spatial resolution. For some applications, boron-based scintillators can be utilized to increase the performance of a digital neutron imaging system by reducing acquisition times and improving neutron statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boron-Based Neutron Scintillator Screen Characterization with X-Rays and Neutrons

Recent work on boron-based neutron scintillator screens suggests these screens can offer superior performance when compared to commonly used screens. Borated neutron scintillator screens perform well in terms of light output (5-6 times greater than a standard Gadox screen) and detection effi-ciency (larger than standard LiF+ZnS screens). However, previously manu-factured boron-based screens have exhibited non-uniform surface coating and a poor mixture between phosphor and converter particles. The objective of this work was to evaluate newly fabricated scintillator screens to deter-mine if enhanced fabrication methods produced a more homogeneous distribution between neutron converter and scintillation phosphor particles. Uniformity of scintillator material deposition was also inspected. This new iteration of screens appeared more uniform than previous generations with the new coating method improving surface chemistry and scintillator material homogeneity. Additionally, a new methodology for screen characterization, involving the correlation of a neutron image taken with a borated scintillator screen to X-ray computed tomography of that same screen, was demonstrated to elucidate a relationship between scintillator screen thickness and relative light output of the screen under neutron exposure. This method suggested that the ideal thickness of scintillator material was ~150 µm to maximize light output of the screen.

36 - MATERIALS SCIENCE↗

Characterization of a boron-loaded deuterated liquid scintillator for fast and thermal neutron detection

The preparation and characterization of novel boron-loaded deuterated liquid scintillators (BLDLS) are presented for the first time to investigate the performance of a detector sensitive to both fast and thermal neutrons intended for future neutron spectroscopy measurements. Three deuterated toluene-based scintillation cocktails were produced, one without boron, one loaded with ortho-carborane (natural boron isotopic abundance), and one with 96 wt% 10B enriched ortho-carborane. General optical and material properties were analyzed to include the composition, density, index of refraction, photoluminescence emission spectra, and absorbance spectra in addition to the relative light yield, resolution, relative efficiency, and pulse-shape-discrimination performance for all three scintillators and a hydrogen-based EJ-309 scintillator to evaluate the effects of boron loading in comparison with a common commercially-available scintillator and feasibility for future neutron spectroscopy measurements. Finally, the detection of shielded neutron sources was explored to capitalize on the 10B thermal neutron capture reaction. The results showed loading the scintillators with boron deteriorated the PSD performance slightly compared to the unloaded deuterated scintillator and resulted in a relative light yield loss of 26% and 41% for the 10B enriched and natural boron BLDLS, respectively. Lastly, the BLDLS have a higher relative detection efficiency than the unloaded deuterated scintillator for shielded neutron sources, based on total count rate, a desirable characteristic for missions related to finding and characterizing illicitly-trafficked special nuclear material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Neutron Response of the EJ-254 Boron-Loaded Plastic Scintillator

Organic scintillators doped with capture agents provide a detectable signal for neutrons over a broad energy range. This work characterizes the fast and slow neutron response of EJ-254, an organic plastic scintillator with 5 loading by weight. For fast neutrons, the primary mechanism for light generation in organic scintillators is n-p elastic scattering. To study the fast neutron response, the proton light yield of EJ-254 was measured at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a broad-spectrum neutron source and a double time-of-flight technique, the EJ-254 proton light yield was obtained over the energy range of approximately 270 keV to 4.5 MeV and determined to be in agreement with other plastic scintillators comprised of the same polymer base. To isolate the slow neutron response, an AmBe source with polyethylene moderator was made incident on the EJ-254 scintillator surrounded by an array of EJ-309 observation detectors. Events in the EJ-254 target coincident with the signature 477.6 keV γ ray (resulting from de-excitation of the residual 7Li nucleus following boron neutron capture) were identified. Pulse shape discrimination was used to evaluate the temporal differences in the response of EJ-254 scintillation signals arising from γ-ray and fast/slow neutron interactions. Clear separation between γ-ray and fast neutrons signals was not achieved and the neutron capture feature was observed to overlap both the γ-ray and fast neutron bands. Taking into account the electron light nonproportionality, the neutron capture light yield in EJ-254 was determined to be 89.4±1.1 keVee.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boron-loaded organic glass scintillators

Herein we report the progress towards an organic glass scintillator with fast and thermal neutron sensitivity providing “triple” pulse shape discrimination (PSD) through the inclusion of a boron-incorporated aromatic molecule. Here, the commercially available molecule 2-(p-tolyl)-1,3,2-dioxaborinane (TDB) can be readily synthesized in one step using inexpensive materials and incorporated into the organic glass scintillator at 20% by weight or 0.25% 10 B by mass. In addition, we demonstrate that TDB can be easily scaled up and formulated into organic glass scintillator samples to produce a thermal neutron capture signal with a light yield equivalent to 120.4 ± 3.7 keVee, which is the highest value reported in the literature to date.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of borated scintillator screens for high-resolution neutron imaging

The most commonly used screens for neutron imaging consist of 6 LiF + ZnS. This type of screen yields the highest light output per detected neutron. For high resolution, gadolinium oxysulfide (GOS, Gadox) screens are employed, which have a much higher detection efficiency, but a light output so much lower than LiF + ZnS that measurements are often limited by photon statistics. Historically, screens using boron as a neutron-sensitive material have not been very successful. However, a new preparation method was introduced recently that produces light output higher than Gadox with detection efficiency greater than LiF + ZnS. Measurements of these new borated screens were performed at the NeXT facility at ILL, Grenoble, in comparison to a high resolution Gadox screen.

10B↗

How silicon and boron dopants govern the cryogenic scintillation properties of N -type GaAs

This work is the first report describing how the concentrations of silicon and boron govern the cryogenic scintillation properties of n-type GaAs. It shows that valence band holes are promptly trapped on radiative centers and then combine radiatively with silicon donor band electrons at rates that increase with the density of free carriers. It also presents the range of silicon and boron concentrations needed for efficient light emission under X-ray excitation, which along with its low band gap and apparent absence of afterglow, make scintillating GaAs suitable for the detection of rare, low-energy electronic excitations from interacting dark matter particles. A total of 29 samples from four different suppliers were studied. Luminosities and timing responses were measured for the four principal emission bands centered at 860, 930, 1070, and 1335 nm, and for the total emissions. Excitation pulses of 40 kVp X-rays were provided by a light-excited X-ray tube driven by an ultra-fast laser. Scintillation emissions from 800 to 1350 nm were measured using an InGaAs photomultiplier. Within the concentration ranges of free carriers from 2 x 10 16 /cm 3 to 6 x 10 17 /cm 3 and boron from 1.5 × 10 18 /cm 3 to 6 x 10 18 /cm 3 , nine samples have luminosities > 70 photons/keV and two have luminosities > 110 photons/keV. Other samples in that range have lower luminosities due to higher concentrations of non-radiative centers. The decay times decrease by typically a factor of ten with increasing free carrier concentrations from 10 17 /cm 3 to 2 x 10 18 /cm 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Manufacturing and characterization of a boron-loaded fast-cured plastic organic scintillator

A novel fast-cured, boron-loaded, plastic organic scintillator was developed and characterized. A diisopropylnaphthalene-containing scintillator was manufactured in minutes with the addition of two commercially available fast-curing monomers, isobornyl acrylate (IBOA) and 1,6-Hexanediol dimethacrylate (HDDMA). Further, the light yield of the device was measured to be approximately 70% relative to a similarly sized, but several-year-aged, EJ-276 detector. Using a coincidence capture technique, the neutron capture light output was found to be 87.7 ± 4.2 keVee, which was 1.47 ± 0.07 greater than the light output from a 59.5 keV electron. Producing a viable fast-cured and thermal-neutron-sensitive detector enables the capability to pursue cost-effective 3D printed thermal neutron detectors in a timely manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗