Search NASA⌕ Search

SEARCH · Search NASA

Results for “bottoming cycle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Performance and Economic Evaluation of sCO2 Bottoming Cycles for Natural Gas Combined Cycle Plants with Capture

Natural gas combined cycles (NGCCs) with carbon capture are expected to play a significant role in decarbonization of the power generation sector. NGCC plants generally use triple pressure reheat steam Rankine power cycles for the bottoming cycle. Some studies in the literature have investigated the application of recompression and cascade style supercritical CO2 (sCO2) cycles for NGCC bottoming cycle applications but these studies have focused on power plants without carbon capture. However, NGCC plants fitted with post-combustion solvent-based CO2 capture systems will require a significant amount of steam for solvent regeneration and this can have a major impact on the optimal sCO2 bottoming cycle design. This study investigates the performance and economic potential of sCO2 bottoming cycles for H-class gas turbine based NGCC plants with a post-combustion capture system. A portion of the gas turbine exhaust heat is used for generation of steam required for solvent-based capture system while the rest of the waste heat is utilized in an sCO2 bottoming cycle for power generation. Overall, the performance and LCOE of investigated sCO2 bottoming cycles is similar to that of a state-of-the-art triple pressure reheat steam Rankine cycle. As the gas turbine exhaust temperature increases (beyond 630oC), sCO2 bottoming cycles begin to show greater performance and economic benefits compared to a steam Rankine cycle.

Pidaparti, Sandeep↗

Performance and Cost Potential of sCO2 Bottoming Cycle for Gas Turbines with Carbon Capture – Paper 32

This study investigates the performance and economic potential of sCO2 bottoming cycles for H-class gas turbine-based NGCC plants with a post-combustion capture system. A portion of the gas turbine exhaust heat is used for the generation of steam required for a solvent-based capture system while the rest of the waste heat is utilized in an sCO2 bottoming cycle for power generation. Overall, the performance and LCOE of investigated sCO2 bottoming cycles are similar to those of a state-of-the-art triple-pressure reheat steam Rankine cycle. As the gas turbine exhaust temperature increases (beyond 630oC), sCO2 bottoming cycles begin to show greater performance and economic benefits compared to a steam Rankine cycle with ~0.7 percentage point higher plant efficiency and 1.4% lower LCOE.

Pidaparti, Sandeep↗

Off-Design Load Analysis of sCO2 Bottoming Cycle for a Natural Gas Combined Cycle Power Plant with Carbon Capture

This work starts with the optimal design from Pidaparti et. al (2024) to analyze the off-design performance of the power plant from 100% down to 50% load. The main operational findings and plant-efficiency for off-load conditions while maintaining the target CO2 capture rate are presented. The goal of the work is to determine if there is a relative advantage or disadvantage for the sCO2 bottoming cycle compared to the steam bottoming cycle in terms of reduced load efficiency performance for the NGCC with carbon capture. Results show nearly identical efficiency profiles for the two cases from 100% to 50% load.

Chinen, Anderson Soares↗

NG-CT Peaker Upgrades with Bottoming Cycle: Preliminary Analysis

The National Energy Technology Laboratory (NETL) has conducted a preliminary analysis exploring a significant opportunity to increase the nation's power grid capacity and reliability. The study focuses on retrofitting under-utilized natural gas combustion turbines (NG-CTs), often called "peaker" plants, with a bottoming cycle to capture waste heat and generate additional electricity. This analysis shows that upgrading these existing assets could add approximately 26,250 MW of new power capacity across the United States. A detailed study of the PJM Interconnection, the nation's largest grid operator, confirmed the benefits of these upgrades. Key findings for the PJM region include: - A median increase in the plants' capacity factor by 17 percentage points. - A projected 36.2% median reduction in the levelized cost of electricity (LCOE) for the upgraded plants, with nearly 88% of them expected to break even. - An average reduction in the regional wholesale price of electricity by approximately 3.0% in the year 2030. - A significant boost to grid reliability, with a 46% reduction in projected Loss of Load Hours (LOLH). These findings suggest that retrofitting peaker plants is a promising and economically viable strategy to enhance grid performance, reduce electricity costs, and meet future demand without the challenges associated with building entirely new facilities.

bottoming cycle↗

Off-Design Load Analysis of sCO2 Bottoming Cycle for a Natural Gas Combined Cycle Power Plant with Carbon Capture

As an alternative to a steam cycle, a supercritical carbon dioxide (sCO2) power cycle can be considered. Able et. al performed an analysis of an sCO2 cycle in a 2x2-1 configuration; however, this study did not include carbon capture. Previous studies assumed an H-Frame turbine and added a solvent based 95% carbon capture system and performed a levelized cost of electricity (LCOE) optimization for the plant. Their results suggest a LCOE slightly better than when using a steam cycle. In the study, steam is still generated in the heat recovery sections for the solvent regeneration in the carbon capture stripper reboiler. H-Frame gas turbines are also assumed. This work starts with the optimal design from the mentioned work to analyze the off-design performance of the power plant from 100% down to 50% load. The main operational findings and plant-efficiency for off-load conditions while maintaining the target CO2 capture rate are presented. H-Frame gas turbine off-design performance and exhaust conditions to the heat recovery section are obtained from commercial software, Thermoflow®. The CO2 turbomachinery, heat exchangers and other unit operations are sized and implemented in an Aspen Plus® model. Using the gas turbine exhaust conditions as input, the sCO2 cycle is optimized by adjusting stream split ratios, sCO2 circulation flowrate and compressor speed for maximum efficiency. This is done while keeping the target 95% CO2 capture.

Chinen, Anderson Soares↗

Novel Modular Heat Engines with sCO 2 Bottoming Cycle Utilizing Advanced Oil-Free Turbomachinery

This report presents the thermal, mechanical, and electric machine design of a 27krpm rotating test rig aimed at reducing technical risks with hermetic oil-free super-critical carbon dioxide (sCO 2 ) turbomachinery. The test rig rotor system is based on a conceptual turbomachine design discussed that evaluates a sCO 2 waste heat recovery (WHR) unit for land-based gas turbines at natural gas (NG) compressor stations. The key novelty of the hermetic sCO 2 turbomachine concept is the utilization of additively manufactured CO 2 gas bearings and a CO 2 -immersed direct-drive permanent magnet (PM) electric machine. The previous effort on conceptual design identified 3 main technical risks, which included thrust bearing load capacity, rotordynamics, and thermal performance of the system. Therefore, key requirements of the test vehicle include the ability to test the rotor system in a 400psi (27.6 bar) hermetic CO 2 operating environment, apply up to 1,500 lbs (6.7 kN) of rotor thrust loads, capability to assess rotordynamics with radial gas bearings, inclusion of instrumentation to assess thrust bearing load capability, and flexibility for varying secondary cooling flows to confirm thermal model predictions. Design topics such as rotordynamics, bearing design, and electric machine design are addressed, while highlighting critical elements. In addition, additive build trials for Inconel 718 radial and thrust bearings were performed to prove the manufacturability of the bearing design concepts. The results of the design efforts yield a test rig concept with ability to operate at 27,000 rpm, apply thrust loads to 1,500 lbs, deliver CO 2 up to 800psi, and modulate cooling flows.

03 NATURAL GAS↗

Adjustable primary and supplemental power units

A propulsion system for an aircraft includes a core flow path in communication with a compressor section, combustor section and a turbine section. A first bottoming cycle system includes a bottoming working fluid flow in thermal communication with a high energy exhaust gas flow that is generated by the core engine. The first bottoming cycle is configured to recover power from the high energy exhaust gas flow in a first engine operating condition and in a second engine operating condition. A second bottoming cycle system is configured to recover power from the high energy exhaust gas flow in the first engine operating condition and not to recover power in a second engine operating condition.

MacDonald, Malcolm P.↗

Techno-Economic Analysis of Greenfield Geothermal Hybrid Power Plants using a Solar or Natural Gas Steam Topping Cycle

The relatively low generation costs associated with wind, solar photovoltaic (PV), and natural-gas power plants make it challenging for geothermal power plants to produce and sell the power that has the reliability and sustainability characteristics that are greatly needed in U.S. power markets. This is especially true for geothermal resources with low-to-medium temperatures, which results in relatively low-thermal efficiency and generation costs that are higher than those for wind, solar PV, and natural gas. This analysis evaluates solar thermal- and natural-gas combustion waste heat recovery-based topping cycle hybridization of geothermal binary power plants. This approach provides several benefits that may allow geothermal power plants to generate power at more competitive costs. First, the addition of solar thermal energy or natural-gas combustion waste heat input to a geothermal power plant provides additional heat input that can be converted to electrical power. Second, the temperature level of the heat obtained from concentrating solar collectors or natural-gas combustion exhaust is higher than that of geothermal heat, which provides opportunities for improving the efficiency of the conversion of thermal energy to electrical power. Third, the ease with which solar thermal systems integrate with energy storage and the flexibility of natural gas means power generation can occur during peak demand periods. The hybrid cycles are compared to equivalently sized, co-located, independent geothermal, concentrating solar, and/or natural-gas power plants. The hybrid cycle tends to produce slightly more power than the standalone plants combined. However, the hybrid plant Levelized Cost of Energy (LCOE) is slightly higher than the LCOE of the combined standalone power plants for each of the case study locations investigated. Using the steam-topping cycle, organic Rankine cycle (ORC)-bottoming cycle hybrid plant design to combine a solar thermal resource and low- temperature geothermal resource (<120 degrees C) leads to a hybrid plant with a lower LCOE than a standalone geothermal-only system. Thus, hybrid plants may enable the economic development of geothermal resources in locations with low geothermal resource temperatures. However, in areas with higher geothermal resource temperatures (>120 degrees C), the geothermal-only plant has a lower LCOE than the hybrid cycle and thus could be developed without the need for solar heat addition. iv A geothermal-natural-gas reciprocating engine hybrid plant was evaluated for an Elk Hills, California case study location. The Elk Hills case study analysis indicates that when the natural-gas engine operates for more than 12 hours per day the hybrid plant can produce power at an LCOE lower than a standalone geothermal plant, and comparable to that of the standalone natural-gas reciprocating engine, while also reducing the carbon intensity of the power generated relative to the standalone natural-gas engine. This may represent a scenario in which the hybrid plant provides an opportunity for the deployment of a low-temperature geothermal resource that otherwise may have an LCOE too high to develop and operate as a standalone resource, while also reducing the carbon intensity of natural-gas generation sources. A "triple-hybrid" plant that combines natural gas, solar thermal, thermal energy storage, and geothermal was also investigated. A natural-gas combustion turbine (NGCT) is added to the geothermal-solar hybrid such that the hot exhaust gas from the gas turbine provides an alternative source of heat to the steam turbine of the hybrid cycle. Analysis results suggest that the triple-hybrid plant has a significantly higher energy generation and revenue than a standalone NGCT or the original geothermal-solar hybrid. The triple-hybrid design benefits most from using a smaller solar field so that the solar energy can be dispatched at the most valuable times available. The triple-hybrid plant also has a lower LCOE than the standalone NGCT. The triple-hybrid plant was evaluated making simple assumptions about the dispatch profile of the gas cycle, and more nuanced and realistic dispatching schedules should be analyzed in future work.

15 GEOTHERMAL ENERGY↗

Hybrid Natural Gas Geothermal Combined Cycle Power Plant Analysis

Low temperature geothermal resources, including those associated with oil and gas production, are an underutilized source of low carbon energy. The present work investigates coupling of low-temperature geothermal resources with concentrating solar and/or natural gas energy sources to increase the number of locations at which power generation from low temperature geothermal resources would be technically and economically viable. Stand-alone and hybrid geothermal power cycles are simulated using SimTech IPSEpro process modeling software. Design point strategies for a hybrid power cycle that may operate with either a single heat source or two simultaneous heat input sources are considered. Additionally, off-design power plant operation is investigated to consider the impacts of the heat source availability and ambient temperature variations. The off-design analysis utilizes a modeling tool that predicts power plant performance at each time step as a function of topping cycle heat input (from gas or solar), bottoming cycle heat input (from geothermal), and ambient temperature. Addition of a steam topping cycle to an organic Rankine cycle geothermal power plant provides opportunities to increase the efficiency and power output relative to a stand-alone geothermal power plant. Additionally, use of the waste heat from gas turbine power generation in a geothermal bottoming cycle provides opportunities to increase the amount of power generation associated with each unit of carbon dioxide emitted. This paper will describe the hybrid plant configuration evaluated, discuss the predicted power cycle performance, and compare with stand-alone natural gas and geothermal power generation cases. The power cycle investigated is expected to be applicable for use with conventional hydrothermal resources as well as with geologic thermal energy storage applications and/or enhanced geothermal systems. The steam topping cycle could use a concentrated solar heat source for fully renewable hybrid plant configuration. A plant initially constructed with a natural gas topping cycle heat source could be converted to a solar heat source part way though the power cycle operational life to achieve life cycle carbon emission reductions.

concentrating solar power↗

Design and Modeling of a Demonstration-scale ORC Cycle for the Liquid Air Combined Cycle

Energy storage is becoming an increasing focus for the future energy markets. One potential hybrid system for ling duration energy storage is the Liquid Air Combined Cycle (LACC). The LACC utilizes excess renewable energy to liquefy and store air during the charge cycle. During its discharge cycle, the system uses the exhaust heat from a conventional combustion turbine and an ORC bottoming cycle to vaporize and superheat the stored air that has been pressurized, which is subsequently expanded to atmosphere through a turbine. During the development of the cycle, it has been identified that the main technologies to advance the cycle are the ORC bottoming cycle machinery and the coupled operation between the liquified air subsystem and the ORC subsystem. This paper presents modeling and simulation of the LACC that involves ORC conditions that fall outside the operating regime of more common applications. Due to the low temperatures of liquified air, the ORC system operates on the order of -70°C for the pump, and the turbine has a pressure ratio around 40. The conceptual design of a demonstration system has been developed that focuses on these challenges in order to advance the overall system.

Pryor, Owen↗

DPE Techno-Economic Analyses

This National Energy Technology Laboratory (NETL) report presents the results of an extensive set of techno-economic analyses for several open-cycle coal fuel oxy-fired direct power extraction (DPE) concepts. These power cycles make use of a conducting plasma accelerated through a magnetic field to generate direct current directly without the need for moving parts. Similar to gas turbines, the efficiency of the power cycle increases with increasing working fluid temperature and typically, plasma temperatures are much higher than the inlet temperature of even the most advanced gas turbine available today, affording the opportunity for very high cycle efficiencies. Most of the study uses high-fidelity models to assess a coal-fueled oxy-combustion DPE system with an AUSC steam bottoming cycle. Two baseline configurations were explored, one with relatively conservative operating point parameters and another with relatively aggressive operating point parameters. Additional analysis on the high-fidelity models as well as reduced order models were performed to analyze the cost and performance potential more thoroughly for the baseline systems and to compare their performance to two alternate open-cycle DPE systems.

30 DIRECT ENERGY CONVERSION↗

System Analysis of an Internal Combustion Engine (ICE) - Solid Oxide Fuel Cell (SOFC) Hybrid Cycle

The variability of renewable energy sources poses challenges for reliable grid operation. Conventional thermal power sources, though reliable, often lack operational flexibility. Hybrid energy systems that integrate Solid Oxide Fuel cells (SOFC) with Internal Combustion Engines (ICE) offer a promising solution by achieving relatively higher efficiency and grid-following capability. This study investigates performance of a 100-kW pressurized SOFC-ICE hybrid cycle. In this configuration, unutilized SOFC fuel is used to drive the engine, with a turbocharger providing air supply and an external reformer generating syngas. System components were numerically modeled using MATLAB/SIMULINK for the SOFC and reformer, and EBSILON® for the ICE and balance of plant. Parametric studies varied fuel utilization (70-90%), reformer temperature (600 – 1000K), anode off-gas recirculation (0 – 70%), and current density (0.2 – 0.55 A/cm2). Results show that the SOFC and ICE operate as thermally independent topping and bottoming cycles, achieving peak efficiency of 62% under optimized conditions.

hybrid↗

Multi-spool CO2 aircraft power system for operating multiple generators

A CO 2 bottoming cycle system includes a first compressor operatively connected to a first turbine through a first shaft. A first generator is operatively connected to the first shaft. A second compressor is fluidically connected to the first compressor. The second compressor is operatively connected to a second turbine through a second shaft. A second generator is operatively connected to the second shaft. The first turbine is fluidically connected to the second turbine.

Taylor, Stephen H.↗

Benchmark Calculation for the Peach Bottom Unit 2 Cycles 1-3 Using the SCALE 6.3/Polaris–PARCS v3.4.2 Code Package

In this study, benchmark calculations were performed for Peach Bottom Unit 2 cycles 1–3 to validate the SCALE 6.3/Polaris–PARCS v3.4.2 with the ENDF/B-VII.1 AMPX 56-group library by comparing the simulated results with the measured data. The benchmark results will be used to evaluate uncertainties of the SCALE/Polaris–PARCS code package for boiling water reactor physics analysis for key nuclear parameters such as reactivity and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS and PARCS. Additionally, detailed information is provided for all the input and output files produced for the benchmark calculations. The benchmark results were summarized such that they can be used to evaluate uncertainties with other benchmark results for key nuclear parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of pumped thermal energy storage using particle media integrated with concentrating solar power

Pumped Thermal Energy Storage (PTES) is an electricity storage system that converts electricity into thermal energy which is stored and later transformed back into electricity. Previous work has illustrated that particles have low capital costs and can be operated over a wide range of temperatures. PTES with particle storage achieves higher round-trip efficiency and specific power output than when molten salt thermal energy storage is used. This article explores hybrid systems that combine PTES with Concentrating Solar Power (CSP). Hybrid systems share the majority of components thereby reducing costs compared to two stand-alone devices. In addition, hybrid systems can provide multiple services (such as renewable power generation and electricity storage services). Using particle thermal storage in these hybrid concepts provides freedom in choosing the design conditions, since a wide range of operating temperatures is allowable, therefore making it possible to identify hybrid system designs that have good performance. In this article, two concepts for hybrid PTES-CSP are introduced. Thermodynamic models are developed and these are used to evaluate the performance of two hybrid systems. These models account for turbomachinery efficiency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The “Solar Top-Up” Concept uses CSP to increase the temperature delivered by the charging heat pump. The discharging system uses a topping gas cycle and a bottoming steam cycle to fully exploit the available energy. Using solar heat to increase the maximum temperature from 750 K to 1100 K increases the round-trip efficiency from 41 % to 62 % and the specific work output from 88 kJ/kg to 301 kJ/kg. The second concept is a “Dual-Mode” device which provides both electricity storage and solar electricity generation with the same set of components. The PTES-mode and CSP-mode performance are optimized at different design values but careful parameter selection leads to good performance of both modes: one design produces PTES round-trip efficiency > 60 %, CSP heat engine efficiency > 40 %, and specific work outputs > 150 kJ/kg (for both cycles), when the particle receiver temperature is > 1200 K and maximum heat pump temperature is 1100 K.

14 SOLAR ENERGY↗

Polaris-PARCS Sensitivity Study on LWR Fuel Cycles: Polaris Input Options

This study is the first of a multi-phase effort to assess the sensitivity of light-water reactor (LWR) core-level prediction biases to changes in lattice-level calculation parameters. Prediction bias is the measured-to-predicted difference in a core-level quantity of interest (QOI) which can be estimated by comparing the simulation results with the plant-measured data for key nuclear parameters. The LWR two-step neutronics codes employed herein are the SCALE–Polaris lattice physics code (v6.3.1) and the Purdue Advanced Reactor Core Simulator (PARCS) nodal diffusion simulator (v3.4.2), both funded and used for confirmatory analysis to support licensing by the US Nuclear Regulatory Commission (NRC). Polaris–PARCS is used to model Watts Bar Unit 1 cycles 1–3 and Peach Bottom Unit 2 cycles 1–3. This study focuses on the impact of changes to Polaris input options such as scattering treatment or quadrature settings and how these input options induce changes in core-level quantities of interest (QOIs)bias. The report documents multiple bias assessments for different modeling choices and compares the bias magnitude to the QOI measurement uncertainties. Future companion reports will investigate the sensitivity of core-level LWR prediction bias to Polaris input options and Polaris-computed QOIs such as few-group assembly-homogenized cross sections to gain an understanding of the key drivers of prediction bias at lattice and core levels for application of a two-step LWR neutronics procedure in a licensing scenario.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Green-Field Geothermal/Solar Designs (Cooperative Research and Development Final Report)

Geothermal power (GEO) and concentrating solar power (CSP) can be integrated to obtain the best aspects of both systems. The green-field design will utilize the full potential of the higher-temperature CSP sector by having a topping solar steam turbine and a bottoming geothermal cycle. In the proposed hybrid cycle, geothermal energy can be converted into electricity at a higher cycle efficiency because of the high-temperature topping cycle during the daytime. CSP benefits from lower-cost solar collectors, a less expensive topping turbine, and virtual elimination of the heat rejection system cost. The green-field case study will be focused on a geothermal resource site which will deliver the 160 - 220 °C pressurized brine at the inlet of power block. While the case study will look at a single case study, the tools to be developed as part of the project will be available to model annual performance of GEO/CSP hybrids for new greenfield projects (may also be applied to certain types of brown-field retrofits). The evaluation tools will also calculate important economic parameters such as the levelized cost of energy (LCOE) and the internal rate of return (IRR).

14 SOLAR ENERGY↗

Validation of the SCALE/Polaris–PARCS Code Procedure With the ENDF/B-VII.1 AMPX 56-Group Library: Boiling Water Reactor

The SCALE/Polaris–PARCS code procedure has been used in the confirmatory analysis for boiling water reactors by the US Nuclear Regulatory Commission. In this study, the SCALE/Polaris v6.3.0–PARCS v3.4.2 code procedure with the Evaluated Nuclear Data File (ENDF)/B-VII.1 AMPX 56-group library was validated by comparing the simulated results with the measured data for operating boiling water reactors, including Peach Bottom Unit 2 cycles 1–3, Hatch Unit 1 cycles 1–3, and Quad Cities Unit 1 cycles 1–3. The uncertainties and biases of the SCALE/Polaris–PARCS code package for boiling water reactor physics analysis were evaluated in the validation for key nuclear parameters such as reactivity and traversing in-core probe data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗