A mechanism for sarcomere breathing: volume change and advective flow within the myofilament lattice
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Lithium sulfur batteries are one of the most promising next-generation energy storage technologies, because of their impressive theoretical energy density, low materials cost, and relative safety. However, incomplete understanding of their underlying operation mechanisms has hindered their further development and commercialization. In this work, to gain a better understanding of the operation mechanisms in the lithium sulfur battery, three macroscopically different (woven and nonwoven) and microscopically similar (made from the same carbon fibers) free-standing carbon felts are used as the conductive matrices to show how the macrostructure influences the redox reactions and the electrochemical performance. Additionally, an operando radiography and simultaneous in situ electrochemical impedance spectroscopy study are performed to highlight the differences of the carbon hosts and how they compare electrochemically in a lithium sulfur battery. The electrochemical results show that the carbon host with a more open structure results in increased capacity as well as a higher diffusion coefficient. The operando radiography shows that the open structures are more conducive to efficient redox reactivity in forming solid sulfur species, mostly in the form of elongated needlelike structures identified as β-S8, near the end of charge, which is corroborated by the impedance data. The data also reveal a “breathing” mechanism, where the polysulfides are pushed to the edges during discharge and pulled back during charge. Furthermore, it is also revealed that the “breathing” process is a limiting factor in the high rate performance. Overall, this study shows that there is a close relationship between the macrostructure of the carbon matrix and the electrochemical performance of the sulfur cathode.
Simulated breath drive mechanism was developed as subsystem to breathing metabolic simulator. Mechanism reproduces complete range of human breath rate, breath depth, and breath waveform, as well as independently controlled functional residual capacity. Mechanism was found capable of simulating various individual human breathing characteristics without any changes of parts.
Abstract Flexible metal–organic materials that exhibit stimulus-responsive switching between closed (non-porous) and open (porous) structures induced by gas molecules are of potential utility in gas storage and separation. Such behaviour is currently limited to a few dozen physisorbents that typically switch through a breathing mechanism requiring structural contortions. Here we show a clathrate (non-porous) coordination network that undergoes gas-induced switching between multiple non-porous phases through transient porosity, which involves the diffusion of guests between discrete voids through intra-network distortions. This material is synthesized as a clathrate phase with solvent-filled cavities; evacuation affords a single-crystal to single-crystal transformation to a phase with smaller cavities. At 298 K, carbon dioxide, acetylene, ethylene and ethane induce reversible switching between guest-free and gas-loaded clathrate phases. For carbon dioxide and acetylene at cryogenic temperatures, phases showing progressively higher loadings were observed and characterized using in situ X-ray diffraction, and the mechanism of diffusion was computationally elucidated.
Subsystem was developed which provides twelve waveform controls to breath drive mechanism. Twelve position, magnetically actuated rotary switch is connected to one end of crankshaft drive, such that it makes one complete revolution for each simulated breath. Connections with common wired point are included in modifications made to standard motor speed controller.
Optical phase modulators operating at visible wavelengths are essential components for photonic technologies such as those for quantum control, communications, and laser ranging. However, they remain challenging to implement in scalable, integrated platforms capable of handling high optical powers. Here we present a visible-light, gigahertz-frequency acousto-optic phase modulator, fabricated on a 200-mm wafer in a volume CMOS foundry, that supports greater than 500 mW of optical power at 730 nm. The device combines a piezoelectric transducer and a photonic waveguide within a single, wavelength-scale structure that confines both a propagating optical mode and an electrically excitable breathing-mode mechanical resonance. By tuning the device’s geometry to optimize the optomechanical interaction, we achieve modulation depths up to 4.85 rad with 80 mW of applied microwave power at 2.31 GHz in a 2-mm-long device. This corresponds to resonant modulation figures of merit of V π = 1.32V and V π ⋅ L = 0.26V cm. To our knowledge, this is the lowest V π ever demonstrated in any acousto-optic phase modulator and represents a 15-fold reduction in V π and a 100-fold reduction in required microwave power relative to state-of-the-art modulators with high visible-wavelength power handling commonly employed in quantum control systems.
The interest in highly sensitive sensors is rapidly increasing for detecting very tiny signals for Internet of Things devices. Here, we achieve ultra-sensitive correlated breathable sensors based on freestanding VO 2 membranes. We fabricate the membranes by growing VO 2 films onto sacrificial Sr 3 Al 2 O 6 layer grown on SrTiO 3 , selectively dissolving the Sr 3 Al 2 O 6 in water, and then rendering freestanding VO 2 membrane on nanomesh. The nanomeshes are extremely flexible, sweat permeable, and readily skin-adhesive. The resistance of the VO 2 membranes is reversibly tuned by human’s tiny mechanical stimuli and breath stimuli. The stimuli modulate the Peierls dimerization of one-dimensional V-V chains in the VO 2 lattice which concomitantly controls the electron correlation and hence resistivity. Since our breathable sensors operate based on quantum-mechanical correlation effects, their sensitivity is 1-2 orders of magnitude higher than conventional tactile and respiratory sensors based on other materials. Thus, the freestanding membranes of correlated oxides on epidermal nanomeshes are multifunctional platforms for developing ultra-sensitive correlated breathable sensors.
We studied the effects of mechanical lung inflation on respiratory frequency R-R interval and arterial pressure fluctuations in nine healthy young adults undergoing elective orthopedic surgery. We conducted this research to define the contribution of pulmonary and thoracic stretch receptor input to respiratory sinus arrhythmia. We compared fast Fourier transform spectral power during three modes of ventilation: (1) spontaneous, frequency-controlled (0.25 Hz) breathing, (2) intermittent positive pressure ventilation (0.25 Hz, with a tidal volume of 8 ml/kg) and (3) high frequency jet ventilation (5.0 Hz, 2.5 kg/cm2), after sedation and vecuronium paralysis. Mean R-R intervals, arterial pressures and arterial blood gas levels were comparable during all three breathing conditions. Respiratory frequency systolic pressure spectral power was comparable during spontaneous breathing and conventional mechanical ventilation, but was significantly reduced during high frequency jet ventilation (P < 0.05). Respiratory frequency R-R interval spectral power (used as an index of respiratory sinus arrhythmia) declined dramatically with sedation and muscle paralysis (P < 0.05), but was greater during conventional mechanical, than high frequency jet ventilation (P < 0.05). These results suggest that although phasic inputs from pulmonary and thoracic stretch receptors make a statistically significant contribution to respiratory sinus arrhythmia, that contribution is small.
Abstract Interlocking metasurfaces (ILMs) are architected arrays of mating features that enable joining of two bodies. Complementary to traditional joining technologies such as bolts, adhesives, and welds, ILMs combine ease of assembly, removal, and reassembly with robust mechanical properties. Structural in nature, they act in a quasi-continuous manner across a surface and enable joining of complex surfaces, e.g., lattices. In this perspective, we define an ILM, begin exploring the design domain and illustrate its breath, and pragmatically evaluate mechanical performance and manufacturability. ILMs will find applications in various fields from aerospace to micro-robotics, civil engineering, and prosthetics.
BACKGROUND: Recent studies providing high-resolution images of pulmonary perfusion have questioned the classical zone model of pulmonary perfusion. Hence the present work was undertaken to provide detailed maps of regional pulmonary perfusion to examine the influence of anesthesia, mechanical ventilation, and posture. METHODS: Pulmonary perfusion was analyzed with intravenous fluorescent microspheres (15 microm) in six sheep studied in four conditions: prone and awake, prone with pentobarbital-anesthesia and breathing spontaneously, prone with anesthesia and mechanical ventilation, and supine with anesthesia and mechanical ventilation. Lungs were air dried at total lung capacity and sectioned into approximately 1,100 pieces (about 2 cm3) per animal. The pieces were weighed and assigned spatial coordinates. Fluorescence was read on a spectrophotometer, and signals were corrected for piece weight and normalized to mean flow. Pulmonary blood flow heterogeneity was assessed using the coefficient of variation of flow data. RESULTS: Pentobarbital anesthesia and mechanical ventilation did not influence perfusion heterogeneity, but heterogeneity increased when the animals were in the supine posture (P < 0.01). Gravitational flow gradients were absent in the prone position but present in the supine (P < 0.001 compared with zero). Pulmonary perfusion was distributed with a hilar-to-peripheral gradient in animals breathing spontaneously (P < 0.05). CONCLUSIONS: The influence of pentobarbital anesthesia and mechanical ventilation on pulmonary perfusion heterogeneity is small compared with the effect of changes in posture. Analysis of flow gradients indicate that gravity plays a small role in determining pulmonary blood flow distribution.
This special publication contains a collection of structural mechanics papers honoring Dr. James H. Starnes, Jr. presented at the 46th AIAA/ASME/ASCE/AHS/ASC Structures, Structural Dynamics, and Materials Conference held in Austin, Texas, April 18-21, 2005. Contributors to this publication represent a small number of those influenced by Dr. Starnes' technical leadership, his technical prowess and diversity, and his technical breath and depth in engineering mechanics. These papers cover some of the research areas Dr. Starnes investigated, which included buckling, postbuckling, and collapse of structures; composite structural mechanics, residual strength and damage tolerance of metallic and composite structures; and aircraft structural design, certification and verification. He actively pursued technical understanding and clarity, championed technical excellence, and modeled humility and perseverance.
The general anatomy and function of the human respiratory system is summarized. Breathing movements, control of breathing, lung volumes and capacities, mechanical relations, and factors relevant to respiratory support and equipment design are discussed.
An anesthetic gas flow pop-off valve canister is described that is airtight and permits the patient to breath freely. Once its release mechanism is activated, the exhaust gases are collected at a hose adapter and passed through activated coal for adsorption. A survey of laminar air flow clean rooms is presented and the installation of laminar cross flow air systems in operating rooms is recommended. Laminar flow ventilation experiments determine drying period evaporation rates for chicken intestines, sponges, and sections of pig stomach.
The development of a breathing metabolic simulator (BMS) is reported. This BMS simulates all of the breathing and metabolic parameters required for complete evaluation and test of life support and resuscitation equipment. It is also useful for calibrating and validating mechanical and gaseous pulmonary function test procedures. Breathing rate, breathing depth, breath velocity contour, oxygen uptake, and carbon dioxide release are all variable over wide ranges simulating conditions from sleep to hard work with respiratory exchange ratios covering the range from hypoventilation. In addition, all of these parameters are remotely controllable to facilitate use of the device in hostile or remote environments. The exhaled breath is also maintained at body temperature and a high humidity. The simulation is accurate to the extent of having a variable functional residual capacity independent of other parameters.
The effect of gravitational orientation in the mechanism of lung filling and emptying in dogs was examined by conducting simultaneously Ar-bolus and N2 single-breath washout tests (SBWTs) in 10 anesthetized dogs (prone and supine), with three of the dogs subjected to body rotation. Transpulmonary pressure was measured simultaneously, allowing identification of the lung volume above residual volume at which there was an inflection point in the pressure-volume curve. Combined resident gas and bolus SBWTs in recumbent dogs were found to be different from such tests in humans; in dogs, the regional distribution of ventilation was not primarily determined by gravity. The measurements did not make it possible to discern exact mechanisms of filling and emptying, but both processes appear to be related to lung, thorax, and mediastinum interactions and/or differences in regional mechanical properties of the lungs.
Abstract We advanced a novel model to calculate viscoelastic lung compliance and airflow resistance in presence of mucus, accounting for the quasi‐linear viscoelastic stress–strain response of the parenchyma (alveoli) tissue. We adapted a continuum‐based numerical modeling approach for the lung, integrating the fluid mechanics of the airflow within individual generations of the bronchi and alveoli. The model accounts for elasticity of the deformable bronchioles, resistance to airflow due to the presence of mucus within the bronchioles, and subsequent mucus flow. Simulated quasi‐dynamic inhalation and expiration cycles were used to characterize the net compliance and resistance of the lung, considering the rheology of the mucus and viscoelastic properties of the parenchyma tissue. The structure and material properties of the lung were identified to have an important contribution to the lung compliance and airflow resistance. The secondary objective of this work was to assess whether a higher frequency and smaller volume of harmonic air flow rate compared to a normal ventilator breathing cycle enhanced mucus outflow. Results predict, lower mucus viscosity and higher excitation frequency of breathing are favorable for the flow of mucus up the bronchi tree, towards the trachea.
The effect of gravity on lung ventilation distribution and the mechanisms of the chest wall were investigated. The following tests were performed with the respiratory monitoring system of the Anthorack, flown onboard Spacelab D2 mission: single breath washout (SBW), multiple breath washout (MBW) and argon rebreathing (ARB). In order to study chest wall mechanisms in microgravity, a respiratory inductive plethysmograph was used. The SBW tests did not reach statistical significance, while the ARB tests showed that gravity independent inhomogeneity of specific ventilation is larger than gravity dependent inhomogeneity. In which concerns the chest wall mechanisms, the analysis on the four astronauts during the normal respirations of the relaxation maneuver showed a 40 percent increase on the abdominal contribution to respiration.
Connecting the geophysical and geochemical signals recorded at and above the surface of volcanoes with source mechanisms is fundamental to understand transitions from quiescence to eruption, and to integrate the behavior of volcanoes with their regional seismotectonic and hydrological context. Some of these signals include shallow volcanic tremor, a long-lasting (minutes-to-years) ground vibration detected in volcanic areas during unrest; volcanic outgassing, which shows intriguing periodicities over multiple scales, as revealed by space-borne instruments and by ground-based, high-frequency (~1 Hz), sampling methods; inflation and deflation of volcanic edifices, commonly associated with subsurface volume changes; and large-scale (from a few to tens of km2), low-temperature, thermal anomalies, a newly-discovered signal that has been observed to emerge on volcanic flanks from months-to-years prior to gas- and magma-driven eruptions. Traditionally, these geophysical and geochemical signals have been modelled independently, which limits our interpretation of subsurface processes and thus our assessment of unrest. In this work, we show through lumped-parameter models, numerical simulations, and preliminary laboratory experiments that many of the signals recorded around volcanoes can be integrated into a common “stop-and-go” mechanism. In particular, we found that they can arise spontaneously when taking into account the feedbacks between the temporary accumulation of gas and/or magma in the crust (“stop”), and the diffusive transfer of gas and heat towards the surface (“go”). For example, we find that the “stop-and-go” mechanism can explain: (i) the emergence of monochromatic, broadband, and harmonic tremor; (ii) the periodic components commonly observed in volcanic outgassing time series; (iii) the link between large-scale thermal anomalies and shallow hydrothermal systems; (iv) the reported time lags between large-scale thermal anomalies and deformation; and (v) the breathing of potentially destructive volcanic calderas. The “stop-and-go” mechanism provides a consistent and realistic framework to link multiple geophysical and geochemical signals with the processes leading to volcanic unrest and eruption.