Bubble coalescence and breakup in turbulent bubbly wake of a ventilated hydrofoil
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Bubble coalescence in longitudinally vibrated liquid column
The most important factors governing the nature of volcanic eruptions are the primary volatile contents, the ways in which volatiles exsolve, and how the resulting bubbles grow and interact. In this contribution we assess the importance of bubble coalescence. The degree of coalescence in alkali basalts has been measured using Image Analysis techniques and it is suggested to be a process of considerable importance. Binary coalescence events occur every few minutes in basaltic melts with vesicularities greater than around 35 percent.
Not Available
Modeling of bubble shapes is challenging because of the wide range of length scales in aluminum reduction cells. A 3D multi-scale mathematical model was developed to understand the nucleation, growth and coalescence of bubbles beneath the anode and to investigate the transition of bubbles from the micro- to macro level. The motion of micro-bubbles is examined using the discrete bubble model (DBM) within a Lagrangian reference. An algorithm for the transition from discrete micro-bubbles to large bubbles, which are fully resolved by the volume of fluid (VOF) approach, is achieved using a user-defined function. The two-way coupling between discrete bubbles and continuous fluids is achieved by inter-phase momentum exchange. The model involves three kinds of bubble coalescence: micro-bubble coalescence is taken into account by the DBM; large bubbles swallowing up micro-bubbles are solved by the discrete-continuum transition model; the coalescence between large bubbles is handled by the VOF method. Numerical results show that the coverage and thickness of bubbles agree well with the experimental data in the literature. Bubble thickness stops increasing when the bubble elongates with the anode bottom, which is 4.0 to 4.5 mm. Meanwhile, two asymmetrical thick heads can be observed under the anode. Bubble release frequency increases with increasing current density.
Boiling heat transfer plays a crucial role in a wide range of applications, such as power generation, refrigeration, electronics cooling, and pharmaceutics. Among the various factors that influence boiling heat transfer, the dynamics of vapor bubble nucleation, growth, and departure from the heated surface stand out as particularly important. An emerging phenomenon that can promote the departure of bubbles smaller than the Fritz diameter is coalescence-induced departure. If the dynamics of this process are fully understood, then surfaces can be engineered to promote faster bubble departure and substantially increase the performance of boiling heat transfer. Further, this work expands on published results by presenting a detailed numerical analysis of bubble coalescence and departure for a range of initial bubble diameters and size ratios between coalescing bubbles. Analysis of the results is focused on explaining how the release of surface energy and bubble surface dynamics lead to bubble departure, as well as fundamentally distinguishing capillary–inertial jumping and buoyant–inertial departure mechanisms across different bubble sizes and size ratios. The results show that both the initial sizes of the coalescing bubbles and the ratio between their sizes can determine whether the merged bubble will leave the surface through capillary–inertial jumping or buoyant departure. Below a certain bubble size, the release of surface energy by the merger is not sufficient to propel the merged bubble from the surface.
The microstructure of pure vanadium after hydrogen ion irradiation at room temperature to a fluence of 1 × 10{sup 17} ions/cm{sup 2} (and 5 × 10{sup 16} ions/cm{sup 2}) was investigated by transmission electron microscopy (TEM). Small dislocation loops (black spots) and cavities are formed after the irradiation. The nature and Burgers vector of dislocation loops formed in vanadium was characterized using g·b technique and inside–outside method. Interstitial dislocation loops with Burgers vector of 1/2 < 111 > predominantly formed with less than 10% of 1/2 < 110 > type. No < 100 > type or vacancy type dislocation loop formed. The microstructural evolution during the annealing process was also studied. Density and size of dislocation loops changed sharply when the annealing temperature was lifted up to 450 °C. When the annealing temperature was higher than 500 °C, bubble coalescence occurred with some large hydrogen bubbles formed. - Highlights: • Interstitial dislocation loops with Burgers vector of 1/2<111> were predominant. • Less than 10% of 1/2<110> dislocation loops were present in pure vanadium. • No <100> or vacancy type loops were present in pure vanadium. • Density and size of dislocation loops changed sharply at temperature above 450 °C. • Bubble coalescence occurred when annealing temperature was higher than 500 °C.
Our team applies a two-fluid model (TFM) from the open-source code Multiphase Flow with Interphase eXchanges (MFIX) to investigate hydrodynamics in a gas–solids fluidized bed with immersed vertical tubes. The cut-cell method implemented in MFIX is used to fully resolve the flow around vertical U-tube banks. Simulations are performed in a bed diameter of 0.145 m with square and triangular tube arrangements, for inlet gas velocities of U0/Umf = 2.3, 4.5 and 6.8. Simulation results are compared with experimental results from the literature and show very good agreement for the bubble size. The efficiency of vertical tubes in reducing bubble size depends upon inlet gas velocity and tube arrangement. Reduction in bubble size is due to the vertical tubes preventing bubble coalescence and promoting bubble splitting. In-bed vertical tubes result in uniform distribution of bubbles within the bed with increase in bubble frequency. The bubble frequency is higher within the bed for square tube arrangements. For a bed with vertical tubes, the bubble shape is generally elongated, which results in high bubble rise velocity. Axial solid velocity and solids circulation patterns are significantly affected by the vertical tubes, where triangular tube arrangements rarely show any solids circulating zone.
Nucleate boiling, especially near the critical heat flux (CHF), can provide excellent economy along with high efficiency of heat transfer. However, the performance of nucleate boiling may deteriorate in a reduced gravity environment and the nucleate boiling usually has a potentially dangerous characteristic in CHF regime. That is, any slight overload can result in burnout of the boiling surface because the heat transfer will suddenly move into the film-boiling regime. Therefore, enhancement of nucleate boiling heat transfer becomes more important in reduced gravity environments. Enhancing nucleate boiling and critical heat flux can be reached using micro-configured metal-graphite composites as the boiling surface. Thermocapillary force induced by temperature difference between the graphite-fiber tips and the metal matrix, which is independent of gravity, will play an important role in bubble detachment. Thus boiling heat transfer performance does not deteriorate in a reduced-gravity environment. Based on the existing experimental data, and a two-tier theoretical model, correlation formulas are derived for nucleate boiling on the copper-graphite and aluminum-graphite composite surfaces, in both the isolated and coalesced bubble regimes. Experimental studies were performed on nucleate pool boiling of pentane on cooper-graphite (Cu-Gr) and aluminum-graphite (Al-Gr) composite surfaces with various fiber volume concentrations for heat fluxes up to 35 W per square centimeter. It is revealed that a significant enhancement in boiling heat transfer performance on the composite surfaces is achieved, due to the presence of micro-graphite fibers embedded in the matrix. The onset of nucleate boiling (the isolated bubble regime) occurs at wall superheat of about 10 C for the Cu-Gr surface and 15 C for the Al-Gr surface, much lower than their respective pure metal surfaces. Transition from an isolated bubble regime to a coalesced bubble regime in boiling occurs at a superheat of about 14 C on Cu-Gr surface and 19 C on Al-Gr surface.
Abstract Boiling is an effective energy‐transfer process with substantial utility in energy applications. Boiling performance is described mainly by the heat‐transfer coefficient (HTC) and critical heat flux (CHF). Recent efforts for the simultaneous enhancement of HTC and CHF have been limited by an intrinsic trade‐off between them—HTC enhancement requires high nucleation‐site density, which can increase bubble coalescence resulting in limited CHF enhancement. In this work, this trade‐off is overcome by designing three‐tier hierarchical structures. The bubble coalescence is minimized to enhance the CHF by defining nucleation sites with microcavities interspersed within hemi‐wicking structures. Meanwhile, the reduced nucleation‐site density is compensated for by incorporating nanostructures that promote evaporation for HTC enhancement. The hierarchical structures demonstrate the simultaneous enhancement of HTC and CHF up to 389% and 138%, respectively, compared to a smooth surface. This extreme boiling performance can lead to significant energy savings in a variety of boiling applications.
An algorithm to prevent or delay bubble coalescence for the level set (LS) method is presented. This novel algorithm uses the LS method field to detect when bubbles are in close proximity, indicating a potential coalescence event, and applies a repellent force to simulate the unresolved liquid drainage force. The model is introduced by locally modifying the surface tension force near the liquid film drainage area. The algorithm can also simulate the liquid drainage time of the thin film by controlling the length of time the increased surface tension has been applied. Thus, a new method of modeling bubble coalescence has been developed. Several test cases were designed to demonstrate the capabilities of the algorithm. The simulations, including a mesh study, confirmed the abilities to identify and prevent coalescence as well as implement the time tracking portion, with an additional 10–25% computational cost. Ongoing tests aim to verify the algorithm's functionality for simulations with different flow conditions, a ranging number of bubbles, and both structured and unstructured computational mesh types. Specifically, a bubble rising toward a free surface provides a test of performance and demonstrates the ability to consistently prevent coalescence. In addition, a two bubble case and a seven bubble case provide a more complex demonstration of how the algorithm performs for larger simulations. These cases are compared to much more expensive simulations capable of resolving the liquid film drainage (through very high local mesh resolution) to investigate how the algorithm replicates the liquid film drainage process.
High level waste melter feed is converted into glass in a joule heated melter, where it forms a floating layer of reacting feed, called the cold cap. After the glass-forming phase becomes connected, evolving gases produce bubbles that form a foam layer under the cold cap. The bubbles coalesce into cavities that escape around the edges of the cold cap. The foam layer insulates the cold cap from the heat transferred from the molten glass below. More information is needed about the formation and behavior of the foam layer to control, limit and possibly avoid foaming, thus allowing for a higher rate of melting. The cold cap behavior was investigated in a laboratory scale assembly with a sealed silica-glass crucible. A high alumina waste simulant was fed into the crucible and the feed charging rate was varied from 3 to 7 mL min-1. After a fixed amount of time (35 min), feed charging was stopped and the crucible was removed from the furnace and quenched on a copper block to preserve the structure of the cold cap and foam during cooling. During the rapid quenching, thermal cracking of the glass and cold cap allowed it to be broken up into sections for analysis. The effect of the charging rate on the height, area and volume of the cold cap was determined. The size of the bubbles collected in the foam layer under the cold cap increased as the cold cap expanded. Under the cold cap, the bubbles coalesced into oblong cavities. These cavities allowed the evolved gases to escape around the edges of the cold cap through the molten glass into the melter plenum.
This research focuses on acquiring accurate flow boiling heat transfer data and flow pattern visualization for three refrigerants, R134a, R236fa and R245fa in a 1.030 mm channel. We investigate trends in the data, and their possible mechanisms, for mass fluxes from 200 to 1600 kg/m{sup 2}s, heat fluxes from 2.3 kW/m{sup 2} to 250 kW/m{sup 2} at T{sub sat} = 31 C and {delta}T{sub sub} from 2 to 9 K. The local saturated flow boiling heat transfer coefficients display a heat flux and a mass flux dependency but no residual subcooling influence. The changes in heat transfer trends correspond well with flow regime transitions. These were segregated into the isolated bubble (IB) regime, the coalescing bubble (CB) regime, and the annular (A) regime for the three fluids. The importance of nucleate boiling and forced convection in these small channels is still relatively unclear and requires further research. (author)
In the aluminum reduction cells, gas bubbles are generated at the bottom of the anode which eventually reduces the effective current contact area and the system efficiency. To encourage the removal of gas bubbles, slotted anode has been proposed and increasingly adopted by some industrial aluminum reduction cells. Nonetheless, the exact gas bubble removal mechanisms are yet to be fully understood. A three-dimensional (3D) transient, multiphase flow mathematical model coupled with magnetohydrodynamics has been developed to investigate the effect of slotted anode on the gas bubble movement. The Eulerian volume of fluid approach is applied to track the electrolyte (bath)–molten aluminum (metal) interface. Meanwhile, the Lagrangian discrete particle model is employed to handle the dynamics of gas bubbles with considerations of the buoyancy force, drag force, virtual mass force, and pressure gradient force. The gas bubble coalescence process is also taken into account based on the O’Rourke’s algorithm. The two-way coupling between discrete bubbles and fluids is achieved by the inter-phase momentum exchange. Numerical predictions are validated against the anode current variation in an industrial test. Comparing the results using slotted anode with the traditional one, the time-averaged gas bubble removal rate increases from 36 to 63 pct; confirming that the slotted anode provides more escaping ways and shortens the trajectories for gas bubbles. Furthermore, the slotted anode also reduces gas bubble’s residence time and the probability of coalescence. Moreover, the bubble layer thickness in aluminum cell with slotted anode is reduced about 3.5 mm (17.4 pct), so the resistance can be cut down for the sake of energy saving and the metal surface fluctuation amplitude is significantly reduced for the stable operation due to the slighter perturbation with smaller bubbles.
The dynamics of bubble coalescence are of importance for a number of industrial processes, in which the size inequality of the parent bubbles plays a significant role in mass transport, topological change and overall motion. In this study, coalescence of unequal-sized microbubbles captive on a solid substrate was observed from cross-section view using synchrotron high-speed imaging technique and a microfluidic gas generation device. The bridging neck growth and surface wave propagation at the early stage of coalescence were investigated by experimental and numerical methods. The results show that theoretical half-power-law of neck growth rate is still valid when viscous effect is neglected. However, the inertial-capillary time scale is associated with the initial radius of the smaller parent microbubble. Furthermore the surface wave propagation rate on the larger parent microbubble is proportional to the inertial-capillary time scale.
In this work, we quantify the impact of grain boundary (GB) and surface diffusion on fission gas bubble evolution and fission gas release in UO 2 nuclear fuel using simulations with a hybrid phase field/cluster dynamics model. Here, we begin with a comprehensive literature review of uranium vacancy and xenon atom diffusivity in UO 2 through the bulk, along GBs, and along surfaces. In our model we represent fast GB and surface diffusion using a heterogeneous diffusivity that is a function of the order parameters that represent bubbles and grains. We find that the GB diffusivity directly impacts the rate of gas release via GB transport, and that the GB diffusivity is likely below 104 times the lower value from Olander and van Uffelen. We also find that the surface diffusivity impacts bubble coalescence and mobility, and that the bubble surface diffusivity is likely below 10 -4 times the value from Zhou and Olander.
Here, U 3 Si 2 , an advanced fuel form proposed for light water reactors (LWR), has excellent thermal conductivity and a higher fissile element density. However, limited understanding of the radiation performance and fission gas behavior of U 3 Si 2 is available at LWR conditions. This study explores the irradiation behavior of U 3 Si 2 by 300 KeV Xe + ion beam bombardment combining with in-situ transmission electron microscopy (TEM) observation. The crystal structure of U 3 Si 2 is stable against radiation-induced amorphization at 350 °C even up to a very high dose of 64 displacements per atom (dpa). Grain subdivision of U 3 Si 2 occurs at a relatively low dose of 0.8 dpa and continues to above 48 dpa, leading to the formation of high-density nanoparticles. Nano-sized Xe gas bubbles prevail at a dose of 24 dpa, and Xe bubble coalescence was identified with an increase of irradiation dose. The volumetric swelling resulting from Xe gas bubble formation and coalescence was estimated with respect to radiation dose, and a 2.2% volumetric swelling was observed for U 3 Si 2 irradiated at 64 dpa considering fission gas only. Due to extremely high susceptibility to oxidation, the nano-sized U 3 Si 2 grains upon radiationinduced grain subdivision were oxidized to nanocrystalline UO 2 in a high vacuum chamber for TEM observation, eventually leading to the formation of UO 2 nanocrystallites up to 80 dpa.
The phenomenological characterization of the use of non-invasive and passive techniques to enhance the boiling heat transfer in water has been carried out in this extended study. It provides fundamental enhanced heat transfer data for nucleate boiling and discusses the associated physics with the aim of addressing future and next-generation reactor thermal-hydraulic management. It essentially addresses the hypothesis that in phase-change processes during boiling, the primary mechanisms can be related to the liquid-vapor interfacial tension and surface wetting at the solidliquid interface. These interfacial characteristics can be significantly altered and decoupled by introducing small quantities of additives in water, such as surface-active polymers, surfactants, and nanoparticles. The changes are fundamentally caused at a molecular-scale by the relative bulk molecular dynamics and adsorption-desorption of the additive at the liquid-vapor interface, and its physisorption and electrokinetics at the liquid-solid interface. At the micro-scale, the transient transport mechanisms at the solid-liquid-vapor interface during nucleation and bubblegrowth can be attributed to thin-film spreading, surface-micro-cavity activation, and micro-layer evaporation. Furthermore at the macro-scale, the heat transport is in turn governed by the bubble growth and distribution, macro-layer heat transfer, bubble dynamics (bubble coalescence, collapse, break-up, and translation), and liquid rheology. Some of these behaviors and processes are measured and characterized in this study, the outcomes of which advance the concomitant fundamental physics, as well as provide insights for developing control strategies for the molecular-scale manipulation of interfacial tension and surface wetting in boiling by means of polymeric reagents, surfactants, and other soluble surface-active additives.