At least 19 records

Optimizing Facility Operations by Applying Machine Learning to the Army Reserve Enterprise Building Control System (Final Report)

Thousands of U.S. Department of Defense (DoD) buildings have building automation systems (BASs) and/or advanced meters. Although these systems have a wealth of data, performance optimization requires time and expertise to review and act on that information. Machine learning (ML) can provide automated and actionable insights to controls operators. This demonstration implemented proven ML methods on the Army Reserve Enterprise Building Control System. ML refers to algorithms that “learn” from data and improve their performance on a given task over time. In the buildings domain these tasks range from predicting future energy consumption, to identifying operational issues before faults occur, to optimizing control decisions. To learn, ML requires input data, which – for buildings – typically consists of instrument data such as energy consumption data and subsystem controls information such as set-point temperatures, and context data consisting of information such as the physical location of the building, the area of the building, and the weather. ML models use the relationships learned from the input data to make predictions with new, previously unseen, data. The team was able to investigate and successfully implement the following ML use cases: labeling consumption data as anomalous or non-anomalous; baseline whole-building load prediction (unknown fault status); fault detection (validation not possible); and site prioritization for energy-related projects. Due to the constraints of the project, interventions were not able to be implemented during the demonstration; therefore, assessments of operational cost savings and maintenance avoided could not be performed. The project has been presented at two leading national building conferences and two additional publications to peer-reviewed journals are currently in preparation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model based co-simulation platform for integrated building system control and design optimization

Both steady-state and dynamic simulations have been widely used by HVAC&R industry to support product/equipment development for decades. Steady-state simulation focuses on the system mass, energy and momentum balance of an equilibrium state. It is based on high-fidelity components models, and thus is suitable for system and component design optimization. Dynamic simulation studies the system transient response and is generally used for controls development and verification. It usually does not require rigorous component models of high accuracy because 1) the commonly used PID control is feedback control whose control performance evaluation doesn’t require high fidelity system/plant model; 2) high-fidelity dynamic model significantly increases the number of equations and variables and creates tremendous challenge for math solver. For supervisory control, transactive control or optimization of an integrated building system, the HVAC&R equipment is often one of the sub-components to be controlled. High-fidelity equipment models are required for accurately evaluating control strategies. In addition, building equipment manufacturers have developed a lot of high-fidelity steady-state equipment/component models per their expertise. Thus, a platform that can integrate OEM high-fidelity steady-state model with dynamic building simulation and/or electric power system & grid simulation to support the development and verification of supervisory control for integrated building systems is necessary. In this study, ORNL’s heat pump design tool (HPDM) is utilized to develop a co-simulation platform for supervisory control and optimization in integrated building systems. It is based on a model that integrates high-fidelity steady-state simulation equipment models with dynamic building simulation. A practical case of using the proposed co-simulation platform to develop and evaluate the supervisory control and optimization is presented and discussed.

Sun, Jian↗

Adaptive Cyber-Physical Resilience for Building Control Systems

The main goal of the project is to develop an AI-based process layer cybersecurity suite for detection, isolation and mitigation of cyber-attack effects on operation of building energy management systems (BEMS). The following constituent key technologies were developed under the program towards fulfilling the program objectives: (1) developed a high fidelity BEMS testbed for generation of training data and validation of developed technologies; (2) developed a physics informed ML based attack detection and localization module (ADL) capable of detecting high impact stealthy attacks (HISA - attacks causing 30% energy utilization but no immediate visible impact otherwise) with 98% accuracy; (3) developed a methodology to determine ’representative days’ to limit the data required for training; (4) developed a virtual sensing system that can reconstruct affected sensors with 10% error for the same HISA set; (5) developed a resilient model predictive control system that can continue operation of the BEMS without jeopardizing stability for the HISA set; and (6) integrated and deployed all the constituent modules and demonstrated the efficacy of the technology in real-time in a hardware in loop simulation.

42 ENGINEERING↗

Reinforcement Learning for Intelligent Building Energy Management System Control *

A building energy management system (BEMS) is a computer-based system designed to monitor and control a building's energy needs. Modern BEMS rely on the sensing and connectivity capabilities of Internet of Things (IoT) technology to intelligently adjust the energy consumption to reduce cost while respecting the consumers' preferences. Increasingly, control decisions are made based on predictions by models trained using supervised machine learning methods, which still requires control policies to be formulated in a rule-based fashion. When using reinforcement learning (RL) instead, control policies are learned by observing the utility in terms of cost and comfort associated with actions such as a change in the heating system's setpoint. The resulting RL-based controllers can capture not only the dynamics of the building and the associated electrical devices, but also fluctuations in electricity prices and user demand, avoiding the need to combine multiple predictive models with tailored control policies. This chapter will provide an overview of RL-based approaches for BEMS. After sketching the taxonomy of general RL methods, we discuss the implications of relying on the individual methods in a BEMS context. Existing work applying RL is presented along the key devices controlled by BEMS systems. Finally, we summarize the state-of-the-art and sketch limitations and open research directions.

Kotevska, Olivera↗

Commercial Building Sensors and Controls Systems: Barriers and Drivers: Preprint

Building sensors and controls systems, including building automation systems, comprise the sensor-based devices installed in buildings as well as the control and automation of those devices. Optimized sensors and controls systems could lead to 29% annual energy savings in commercial buildings and are integral to the growth of grid-interactive efficient buildings. Only 13% of small commercial buildings, however, have installed sensors and controls systems, largely because of cost barriers. To accelerate adoption, this work seeks to increase the transparency of system costs and identify specific barriers and drivers. To gather industry insights, the team reached out to building owners, vendors, and contractors and conducted 21 interviews with the goal of collecting cost data and market characteristics regarding building sensors and controls. We collected the cost data in the form of invoices and used it to develop a percentage-based cost category breakdown. The interview data were analyzed using grounded theory to identify overarching concepts such as barriers, drivers, and future directions. From this analysis, we found the primary barriers to be complex and confusing systems, lack of user skills, and financial concerns, and the primary drivers to be operational benefits, insight into operations, and remote access to data. The future directions analysis highlighted the potential technological solutions to address gaps and barriers, as well as predicted drivers to increase adoption. This greater understanding of the costs, barriers, and drivers associated with commercial building sensors and controls systems lays the groundwork for increasing system adoption, reducing energy consumption, and transforming the market.

building automation system↗

Machine Learning for Automated Metadata Assignment in Buildings: Cooperative Research and Development (Final Report, CRADA Number CRD-18-00767)

RealTerm Energy and NREL have identified a shared vision to evaluate opportunities to facilitate the organization and assignment of metadata to building control system (BCS) data via industry-informed machine learning (ML). Manual metadata assignment is labor intensive and costly, slowing down any Energy Management and Information System (EMIS) deployment in the building space. This project aims to develop methodologies to accurately assign this metadata and significantly decrease the level of effort associated with deploying EMIS. The objective of this project is to identify/design methodologies to assign metadata to HVAC control points automatically. The identified methodologies will be programmed in analytics algorithms so they can ingest a list of points and produce a detailed tagging following the Haystack classification nomenclature. To validate the efficacy of each methodology, tagging results will be compared utilizing a list of points extracted from RealTerm's building database-as well as data extracted from the NREL campus via the Intelligent Campus program-enabling testing against large datasets with real world challenges. The developed methodologies may leverage building manager/operator input on a limited basis to add context to the classifying algorithms. The partnership aims to advance global efforts in areas related to the DOE missions through improving operational performance of commercial buildings. It is well documented that buildings fall out of commission after they are occupied, wasting significant energy and incurring associated costs simply due to poor operational performance. Emerging EMIS technologies that perform continuous commissioning help to address this issue, yet integration of these systems can be labor intensive both for the technology vendor and the building owner/operator. This project will enable more efficient and cost-effective analytics for buildings, enabling improvement in building operations at lower cost points.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Commercial Building Sensors and Controls Systems: Barriers, Drivers, and Costs

Building sensors and controls systems, including building automation systems, consists of the sensor-based devices installed in buildings and the control and automation of those devices. Optimized sensors and controls systems could lead to 29% annual energy savings in commercial buildings and are integral to the growth of grid-interactive efficient buildings. Only 8% of small commercial buildings, however, have installed sensors and controls systems. This is largely due to cost barriers. This work seeks to increase the transparency of system costs and identify specific barriers and drivers for increased adoption. To gather industry insights, the team reached out to building owners, vendors, and contractors and conducted 20 interviews with the goal of collecting cost data and market characteristics regarding building sensors and controls. The qualitative interview data was analyzed using grounded theory to identify overarching concepts, such as barriers, drivers, and future directions on the field. From this analysis, primary barriers were found to be complexity, a lack of knowledge, and money. Primary drivers were found to be the knowledge of data, savings, and remote access. The qualitative cost data was collected in the form of invoices during the interviews. The cost values were used to develop a percentage-based cost stack which identifies the average fraction of the total cost attributed to each category (hardware, software, labor, fees, and taxes). This greater understanding of costs and barriers associated with commercial building sensors and controls systems lays the groundwork for future steps in increasing system adoption, reducing energy consumption, and market transformation.

advanced building controls↗

Laboratory testing methods to evaluate the reliability of occupancy sensors for commercial building applications

The energy performance of commercial buildings is greatly influenced by occupants which are highly variable and among the most unpredictable components of a building's operation. While most building control systems use fixed, predetermined occupancy schedules, these fixed occupancy levels can be quite different from actual occupancy. This can cause unnecessary energy consumption, particularly from heating, ventilation, and air conditioning (HVAC) and lighting systems which are responsible for approximately 60% of commercial buildings' energy use. The use of occupancy counting sensor systems integrated with building management system controls is one method that can be used to improve the energy-consuming performance of buildings. However, there is no standardized universal methodology and metrics to evaluate their reliability. The aim of this research is to develop a uniform evaluation methodology to assess the reliability of occupancy counting sensor systems in a controlled laboratory environment. The developed testing methodology includes both “typical” scenarios representing the occupancy scenarios of a typical commercial building, and “failure” testing scenarios which represent a range of potential scenarios that may impact a sensor system's reliability. These methods were then implemented in a case study to evaluate the performance of two novel occupancy counting sensor systems (i.e., door-centric, and camera-based). Results suggest that typical testing results can be used to compare the overall performance of the occupancy counting sensor systems; however, failure testing is also important to understand the weaknesses of the sensor system in order to select the suitable one for the intended use of the commercial building. In addition, the proposed methodology includes a modified confusion matrix which enables the ability to identify if failures are caused by over or under counting occupants and to what extent this occurs over the testing period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation-based Performance Evaluation of Model Predictive Control for Building Energy Systems

The performance of model predictive control (MPC) can be significantly affected by different choices of controller parameters such as the time intervals for model discretization and control sampling. Due to the lack of a systematic understanding on how these parameters affect control performance, they are usually selected arbitrarily in practice.In this paper, the combined impacts of selected time intervals for model discretization and control sampling on the performance of MPC are comprehensively investigated for the first time through detailed simulations. Specifically, a typical MPC strategy is first designed to improve building operations based on a reduced-order model of building dynamics. Then, the performance of the designed MPC is evaluated against different choices of time intervals for model discretization and control sampling on a simulated office building. The detailed simulation results reveal that the time interval for model discretization has a much greater influence on the performance of MPC than the time interval for control sampling. Although the time interval for control sampling usually receives more attentions in practice, it turns out that the time interval for model discretization affects the prediction performance, cost saving, and computation time simultaneously and more significantly. Therefore, the simulation-based performance evaluation presented here sheds light on the impacts of different time intervals and facilitates their selection for practical applications of MPC to building operations

Huang, Sen↗

Systems and methods for monitoring traffic on industrial control and building automation system networks

Technologies relating to monitoring communications traffic to detect potential attacks on industrial control system networks and building automation system networks are described herein. In an embodiment, a monitoring device receives a plurality of communications from a control network. The monitoring device transmits the communications to a computing device. Based on the communications, the computing device generates a listing of devices that communicated by way of the control network over a period of time, and computes a volume of traffic between each pair of devices in the listing of devices. The computing device then outputs a graphical user interface (GUI) by way of display, the GUI comprising data indicative of the computed volumes of traffic, which may be indicative of a potential attack on the control network.

Jenkins, Chris↗

Commercial Building Sensors and Controls Systems - Barriers, Drivers, and Costs

Optimized building sensors and controls systems could lead to 29% annual energy savings in commercial buildings and are integral to the growth of grid-interactive efficient buildings. However, only 8% of small commercial buildings have installed sensors and controls systems-which is largely due to cost barriers. This publication seeks to increase the transparency of system costs and identify specific barriers and drivers for increased adoption. Qualitative interview data was collected from 20 interviews with industry and qualitative cost data was collected from invoices during the interviews. The greater understanding of costs and barriers associated with commercial building sensors and controls systems lays the groundwork for future steps in increasing system adoption, reducing energy consumption, and market transformation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data-Enabled Predictive Control for Building HVAC Systems

Model predictive control is widely used as a control technology for the computation of optimal control inputs of building heating, ventilating, and air conditioning (HVAC) systems. However, both the benefits and widespread adoption of model predictive control (MPC) are hindered by the effort of model creation, calibration, and accuracy of the predictions. In this paper, we apply the data-enabled predictive control (DeePC) algorithm for designing controls for building HVAC systems. The algorithm solely depends on input/output data from the system to predict future state trajectories without the need for system identification. The algorithm relies on the idea that a vector space of all input–output trajectories of a discrete-time linear time-invariant (LTI) system is spanned by time-shifts of a single measured trajectory, given the input signal is persistently exciting. Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated building modeled in EnergyPlus is a modified commercial large office prototype building served by an air handling unit-variable air volume HVAC system. Temperature setpoints of zones are used as control variables to minimize the HVAC energy cost of the building considering a time-of-use electricity rate structure. Furthermore, sensitivity analysis is conducted to gain insights into the effect of parameter tuning on DeePC performance. Simulation results are used to illustrate the performance of the algorithm and compare the algorithm with model-based MPC and occupancy-based setpoint controller. Overall, DeePC achieves similar performance compared to MPC for lower engineering effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Control Systems Design for STS Accelerator

The Second Target Station (STS) Project will expand the capabilities of the existing Spallation Neutron Source (SNS), with a suite of neutron instruments optimized for long wavelengths. A new accelerator transport line will be built to deliver one out of four SNS pulses to the new target station. The Integrated Control Systems (ICS) will provide remote control, monitoring, OPI, alarms, and archivers for the accelerator systems, such as magnets power supply, vacuum devices, and beam instrumentation. The ICS will upgrade the existing Linac LLRF controls to allow independent operation of the FTS and STS and support different power levels of the FTS and STS proton beam. The ICS accelerator controls are in the phase of preliminary design for the control systems of magnet power supply, vacuum, LLRF, Timing, Machine protection system (MPS), and computing and machine network. The accelerator control systems build upon the existing SNS Machine Control systems, use the SNS standard hardware and EPICS software, and take full advantage of the performance gains delivered by the PPU Project at SNS.

Yan, Jay↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Unified architecture for data-driven metadata tagging of building automation systems

This article presents a Unified Architecture (UA) for automated point tagging of Building Automation System (BAS) data, based on a combination of data-driven approaches. Advanced energy analytics applications—including fault detection and diagnostics and supervisory control—have emerged as a significant opportunity for improving the performance of our built environment. Effective application of these analytics depends on harnessing structured data from the various building control and monitoring systems, but typical BAS implementations do not employ any standardized metadata schema. While standards such as Project Haystack and Brick Schema have been developed to address this issue, the process of structuring the data, i.e., tagging the points to apply a standard metadata schema, has, to date, been a manual process. This process is typically costly, labor-intensive, and error-prone. In this work we address this gap by proposing a UA that automates the process of point tagging by leveraging the data accessible through connection to the BAS, including time-series data and the raw point names. The UA intertwines supervised classification and unsupervised clustering techniques from machine learning and leverages both their deterministic and probabilistic outputs to inform the point tagging process. Furthermore, we extend the UA to embed additional input and output data-processing modules that are designed to address the challenges associated with the real-time deployment of this automation solution. We test the UA on two datasets for real-life buildings: (i) commercial retail buildings and (ii) office buildings from the National Renewable Energy Laboratory (NREL) campus. We report the proposed methodology correctly applied 85–90% and 70–75% of the tags in each of these test scenarios, respectively for two significantly different building types used for testing UA's fully-functional prototype. The proposed UA, therefore, offers promising approach for automatically tagging BAS data as it reaches close to 90% accuracy. Further building upon this framework to algorithmically identify the equipment type and their relationships is an apt future research direction to pursue.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building fault detection data to aid diagnostic algorithm creation and performance testing

It is estimated that approximately 4-5% of national energy consumption can be saved through corrections to existing commercial building controls infrastructure and resulting improvements to efficiency. Correspondingly, automated fault detection and diagnostics (FDD) algorithms are designed to identify the presence of operational faults and their root causes. A diversity of techniques is used for FDD spanning physical models, black box, and rule-based approaches. A persistent challenge has been the lack of common datasets and test methods to benchmark their performance accuracy. This article presents a first of its kind public dataset with ground-truth data on the presence and absence of building faults. This dataset spans a range of seasons and operational conditions and encompasses multiple building system types. It contains information on fault severity, as well as data points reflective of the measurements in building control systems that FDD algorithms typically have access to. The data were created using simulation models as well as experimental test facilities, and will be expanded over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building ControlScore: General Service Administration Office Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore concept, which takes operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control). PNNL applied the Building ControlScore application to all available data from a General Services Administration office building within the period of January 1, 2023, to March 9, 2023. The building scored a 4.7 overall, with all 74 of the building’s loops fitting a roughly normal distribution centered around 5. These results indicate that the analyzed systems have below-average performance with room for improvement, especially in the poorly scored systems. Airflow loops tended to have much lower scores than zone temperature loops. The lowest and highest performing systems in the building section were identified, as were all loops with a score less than 1. While the ControlScore identifies loops and systems that aren’t meeting their designated setpoints, it does not indicate the cause of those issues. For example, consider a supply air terminal unit’s airflow loop that received a low score due to it delivering less air than specified by the setpoint. The lower-than-desired airflow could be due to equipment limitations (e.g., the terminal unit or duct serving is too small to accommodate that airflow), malfunctioning equipment (e.g., a stuck damper or bad sensor), or something else entirely. The ControlScore does not diagnose problems it simply identifies the symptoms that can be explored and addressed by building operators.