Search NASA⌕ Search

SEARCH · Search NASA

Results for “building energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Creating A Consistent Historical NASA POWER Solar Radiation Dataset to Support Renewable Energy, Building Energy Efficiency and Agro-Climatology Decisions

Prediction of Worldwide Energy Resources (POWER) project provides irradiance dataset to support renewable energy, building energy efficiency and agricultural needs. These datasets are derived from Global Energy and Water Cycle Experiment Surface Radiation Budget (GEWEX SRB) and Clouds and the Earth’s Radiant Energy System (CERES SYN1Deg). A systematic bias has been reported between these two datasets for the years with overlapping observations. For obtaining a consistent climate data record spanning the entire time record of observations, it is crucial to understand and remove the bias in the irradiance dataset. Inconsistency in solar radiation data can lead to inaccurate conclusions about solar energy potential and obscure real trends in solar radiation patterns that would impact energy availability assessments. In this study, we adapt quantile mapping approach to remove the systematic bias and to improve reliability of shortwave and longwave irradiance data. We present a validation of the bias corrected data against ground truth. For each 1° latitude and 1° longitude grid box across the globe, we match the CDFs of the reference dataset (CERES SYN1Deg) to that of the SRB dataset, thereby, adjusting the irradiance values to match the empirical distribution of two different measurements. The performance of quantile mapping is evaluated by using the metrics such as Mean Absolute Deviation (MAD). The results indicate that the quantile mapping significantly improves the accuracy and reliability of solar irradiance dataset especially for the weather conditions associated with high cloud cover and extreme irradiance values. The initial range of MAD for the studied sites for daily data was 4 to 19 Wm-2. After correction these reduced to 3 to 7 Wm-2. The findings from this study have important implications for solar energy system design, agricultural planning, and climate modeling community. Reducing the inconsistency and biases in solar irradiance dataset can enable better planning and operation of solar energy systems, leading to increased efficiency and cost-effectiveness. Additionally, this work also contributes to the statistical post-processing techniques in the renewable energy domain and highlights the potential of historical and near-real-time NASA POWER dataset as a valuable resource for solar energy research and applications.

POWER↗

Main Street Zero Energy Buildings: The Zero Energy Method in Concept and Practice: Preprint

Ongoing work at the National Renewable Energy Laboratory indicates that net-zero energy building (NZEB) status is both achievable and repeatable today. This paper presents a definition framework for classifying NZEBs and a real-life example that demonstrates how a large-scale office building can cost-effectively achieve net-zero energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototype College Building Energy Model: Building Characteristics and Energy Simulation Results

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 16 prototype building models, which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype college building, and a 4-story with 69,063 ft 2 building was considered as the prototype college building to represent an average-sized college building in the United States. To represent realistic occupancy schedules and increase the granularity of information, actual class reservation schedules were collected and used. This report documents the building and system characteristics of the prototype college building model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. The site energy use intensity of the college building was compared with 2012 Commercial Building Energy Consumption Survey (CBECS) and ENERGY STAR data to verify the simulation results. The site energy use intensity of the college building ranged from 60 to 202.4 kBtu/ft 2 , and compared with the energy use intensities of Commercial Building Energy Consumption Survey (122.9 kBtu/ft 2 ) and ENERGY STAR (84.3 kBtu/ft 2 ) data, the prototype college building results are in a reasonable range.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototype Courthouse Building Energy Model: Building Characteristics and Energy Simulation Results

To coordinate commercial building energy research activities, the US Department of Energy uses a suite of commercial prototype building models, which includes 16 building types and covers 80% of US commercial floorspace. Efforts are underway to expand this suite by developing prototype models for additional building types, including a courthouse. Informed by building design guides, databases, documented projects, and personal communication with courthouse design experts, a 3-story, 4-courtroom, 69,324 ft 2 building was considered as the prototype courthouse to represent an average-sized courthouse in the United States. This report documents the building and system characteristics of the prototype courthouse model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. To verify the energy simulation results, energy use statistics of existing courthouses from different building database are also presented. Based on the simulated energy use, the site energy use intensity of the prototype courthouse ranged from 45 to 159 kBtu/ft 2 compared with the average energy use intensity of 94.7 kBtu/ft 2 for the courthouse building type in the 2012 Commercial Building Energy Consumption Survey (CBECS) Data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy Efficiency in India: Compliance Evaluation of Energy Conservation Building Code

India is experiencing unprecedented construction boom. The country doubled its floorspace between 2001 and 2005 and is expected to add 35 billion m 2 of new buildings by 2050. Buildings account for 35% of total final energy consumption in India today, and building energy use is growing at 8% annually. Studies have shown that carbon policies will have little effect on reducing building energy demand. Chaturvedi et al. predicted that, if there is no specific sectoral policies to curb building energy use, final energy demand of the Indian building sector will grow over five times by the end of this century, driven by rapid income and population growth. The growing energy demand in buildings is accompanied by a transition from traditional biomass to commercial fuels, particularly an increase in electricity use. This also leads to a rapid increase in carbon emissions and aggravates power shortage in India. Growth in building energy use poses challenges to the Indian government.

Code Compliance Evaluation↗

A Mobility-Driven Approach to Modeling Building Energy

Buildings are one of the primary energy consumers in any city's energy use [12]. Presence and absence of humans is a major contributing factor to the energy use in a building. In this paper, we present an approach to generating a realistic model of human building occupancy throughout a typical work week. We use the Toolbox for Urban Mobility Systems (TUMS) to generate a synthetic population based on population distribution estimates, we schedule the population's daily commute based on National Household Travel Survey (NHTS) survey data, and we simulate their daily travel patterns using an agent-based transportation simulation (TRANSIMS). We process and fuse the simulation output to produce a list of the first and last seen location of each agent in the simulation. Based on the arrival at the last destination, we map each agent to one of the nearby buildings. Using these agent arrivals, as well as NHTS data, we create an hourly occupancy schedule for each building. We successfully demonstrate this workflow at the example of the Chicago Loop, a major business district in Chicago, Illinois.

Berres, Andy↗

R&D and Implementation Outcomes from the U.S.-India Bilateral Center for Building Energy Research and Development Program

This paper explores the role of international partnerships to facilitate low-energy building design, construction, and operations. We present the strategic approach, joint research and development outcomes, and implementation activities of a unique U.S.-India program on buildings energy efficiency, the Center for Building Energy Research and Development. We discuss the collaboration successes in both countries despite their dissimilar building contexts, implementation challenges and opportunities. We highlight a range of R&D outcomes, such as novel tools and technologies developed and tested by the joint teams, with their technical energy savings potential, as well as results of capacity building and technology demonstrations. A deep-dive into key new scientific methods around building energy monitoring and benchmarking that could have a significant impact on high-performance of buildings in both countries is also provided. Finally, in addition to joint R&D successes, pathways to deployment, and lessons learned are discussed as key takeaways.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototype Courthouse Building Energy Model: Building and System Characteristics

As part of the Department of Energy’s support of ANSI/ASHRAE/IES Standard 90.1 and the International Energy Conservation Code, researchers at Pacific Northwest National Laboratory apply a suite of prototype buildings covering 80% of the commercial building floor area in the United States for new construction. Efforts have begun to cover 90% of the commercial building floor area in the United States by developing prototype models for additional building types that include supermarket, laboratory, place of worship, public order and safety, and public assembly. “Courthouse” is a subcategory under the “Public Order and Safety” building type category defined by the Commercial Buildings Energy Consumption Survey (CBECS); other subcategories include police station, fire station, and detention and correctional facilities (i.e., jail, reformatory, or penitentiary). Oak Ridge National Laboratory used building design guides, databases, and documented courthouse projects, supplemented by personal communication with courthouse facility planning and design experts, to systematically conduct research on the courthouse building and system characteristics. This report documents this research and reports the building and system characteristics necessary for developing a Courthouse prototype building energy model to be included in the Commercial Building Prototype Model suite.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Practical Integration Approach and Whole Building Energy Simulation of Three Energy Efficient Building Technologies: Preprint

Three technologies that have potential to save energy and improve sustainability of buildings are dedicated outdoor air systems, radiant heating and cooling systems and tighter building envelopes. To investigate the energy savings potential of these three technologies, whole building energy simulations were performed for a barracks facility and an administration facility in 15 U.S. climate zonesand 16 international locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An international survey of building energy codes and their implementation

Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy demand from buildings. Access to benefits of building energy codes depends on comprehensive coverage of buildings by type, age, size, and geographic location; an implementation framework that involves a certified agency to inspect construction at critical stages; and independently tested, rated, and labeled building energy materials. Training and supporting tools are another element of successful code implementation, and their role is growing in importance, given the increasing flexibility and complexity of building energy codes. Some countries have also introduced compliance evaluation and compliance checking protocols to improve implementation. This article provides examples of practices that countries have adopted to assist with implementation of building energy codes.

54 ENVIRONMENTAL SCIENCES↗

Comparison of Building Energy Modeling Programs: Building Loads

This technical report presented the methodologies, processes, and results of comparing three Building Energy Modeling Programs (BEMPs) for load calculations: EnergyPlus, DeST and DOE-2.1E. This joint effort, between Lawrence Berkeley National Laboratory, USA and Tsinghua University, China, was part of research projects under the US-China Clean Energy Research Center on Building Energy Efficiency (CERC-BEE). Energy Foundation, an industrial partner of CERC-BEE, was the co-sponsor of this study work. It is widely known that large discrepancies in simulation results can exist between different BEMPs. The result is a lack of confidence in building simulation amongst many users and stakeholders. In the fields of building energy code development and energy labeling programs where building simulation plays a key role, there are also confusing and misleading claims that some BEMPs are better than others. In order to address these problems, it is essential to identify and understand differences between widely-used BEMPs, and the impact of these differences on load simulation results, by detailed comparisons of these BEMPs from source code to results. The primary goal of this work was to research methods and processes that would allow a thorough scientific comparison of the BEMPs. The secondary goal was to provide a list of strengths and weaknesses for each BEMP, based on in-depth understandings of their modeling capabilities, mathematical algorithms, advantages and limitations. This is to guide the use of BEMPs in the design and retrofit of buildings, especially to support China’s building energy standard development and energy labeling program. The research findings could also serve as a good reference to improve the modeling capabilities and applications of the three BEMPs. The methodologies, processes, and analyses employed in the comparison work could also be used to compare other programs. The load calculation method of each program was analyzed and compared to identify the differences in solution algorithms, modeling assumptions and simplifications. Identifying inputs of each program and their default values or algorithms for load simulation was a critical step. These tend to be overlooked by users, but can lead to large discrepancies in simulation results. As weather data was an important input, weather file formats and weather variables used by each program were summarized. Some common mistakes in the weather data conversion process were discussed. ASHRAE Standard 140-2007 tests were carried out to test the fundamental modeling capabilities of the load calculations of the three BEMPs, where inputs for each test case were strictly defined and specified. The tests indicated that the cooling and heating load results of the three BEMPs fell mostly within the range of spread of results from other programs. Based on ASHRAE 140-2007 test results, the finer differences between DeST and EnergyPlus were further analyzed by designing and conducting additional tests. Potential key influencing factors (such as internal gains, air infiltration, convection coefficients of windows and opaque surfaces) were added one at a time to a simple base case with an analytical solution, to compare their relative impacts on load calculation results. Finally, special tests were designed and conducted aiming to ascertain the potential limitations of each program to perform accurate load calculations. The heat balance module was tested for both single and double zone cases. Furthermore, cooling and heating load calculations were compared between the three programs by varying the heat transfer between adjacent zones, the occupancy of the building, and the air-conditioning schedule.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Different Methods for Computing Source Energy in the Context of Zero Energy Buildings

Building energy consumption can only be measured at the site or at the point of utility interconnection with a building. Often, to evaluate the total energy impact, this site-based energy consumption is translated into source energy, that is, the energy at the point of fuel extraction. Consistent with this approach, the U.S. Department of Energy's (DOE) definition of zero energy buildings uses source energy as the metric to account for energy losses from the extraction, transformation, and delivery of energy. Other organizations, as well, use source energy to characterize the energy impacts. Four methods of making the conversion from site energy to source energy were investigated in the context of the DOE definition of zero energy buildings. These methods were evaluated based on three guiding principles--improve energy efficiency, reduce and stabilize power demand, and use power from nonrenewable energy sources as efficiently as possible. This study examines relative trends between strategies as they are implemented on very low-energy buildings to achieve zero energy. A typical office building was modeled and variations to this model performed. The photovoltaic output that was required to create a zero energy building was calculated. Trends were examined with these variations to study the impacts of the calculation method on the building's ability to achieve zero energy status. The paper will highlight the different methods and give conclusions on the advantages and disadvantages of the methods studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Building ENergy Demand (BEND) Model: A Comprehensive Composite Building Energy Modeling Framework

The Building ENergy Demand (BEND) model was developed at Pacific Northwest National Laboratory (PNNL) to simulate climate-dependent hourly building energy demand with the ability to disaggregate down to or aggregate up to any geographic area of interest, including counties, states, electric utility service territories, and census regions. The BEND modeling framework is designed to study the effects of climate change, economics, technology advancement, and various mitigation policies on aggregate building energy demand. To make the process computationally feasible, BEND reduces granularity in building characteristics and weather forcing while maintaining enough detail to minimize systematic differences (biases) between BEND results and data from the Energy Information Administration (EIA). Based on the Commercial Building Energy Consumption Survey (CBECS) and Residential Energy Consumption Survey (RECS) databases, BEND establishes a set of representative buildings with predefined sets of building types, sizes, and vintages. These representative buildings are defined for each of the four U.S. census regions and the five climate zones used by the EIA for building surveys (hereafter “EIA climate zones”). BEND’s representative buildings are based on a statistical analysis of the CBECS and RECS databases that infers detailed parameters such as construction type, thermal properties, internal loads, equipment and mechanical systems, and operation schedules from the high-level descriptors in those databases (building type, vintage, size, and location). The representative buildings are simplified and consolidated into a set of prototype buildings for the purpose of simulating building energy demand. Combining the prototype buildings with weather files from selected locations and years, BEND creates a set of simulation-ready building models to be run using the EnergyPlus simulation engine (EnergyPlus). The base spatial unit of each BEND simulation is a subregion that is the intersection of an International Energy Conservation Code climate zone, a census region, and an EIA climate zone; analysis for each spatial unit is influenced by the weather file BEND selects to represent the climate-similar area. The major simulation outputs of interest to BEND are hourly energy consumption values for each simulated year, possibly for multiple fuel types. Based on building-stock weights derived from the CBECS/RECS data, the hourly output streams are aggregated to a single, 8760-hour load profile for each of the major building categories—residential and commercial—with the possibility of segregating by fuel types. To correct for biases inherent in the use of a limited suite of representative buildings, BEND is calibrated against observational targets of total annual building energy consumption and hourly load profiles (including peak demand) obtained for the decision-relevant geographic scales of interest (e.g., total electric load data for individual balancing authorities available from EIA). Based on available data such as population distribution, BEND is able to aggregate both up and down scales, allowing the study of building energy demand over a range of spatial scales (e.g., states or counties within the Western Electricity Coordinating Council, Eastern Interconnection, or the entire U.S.) and/or subsets of building types (e.g., office buildings with particular size ranges).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing overall building energy performance of a large population of residential single-family homes using limited field data

The U.S. Department of Energy (DOE), through the Building Energy Codes Program (BECP), supports building energy code development and implementation processes to achieve the maximum practicable, cost-effective improvements in energy efficiency while providing safe, healthy buildings for occupants. Currently, there is a lack of statistically representative data that shows how energy codes are implemented in the field and the energy savings opportunities that exist. To address this gap, DOE initiated a research study targeted at new residential single-family homes in 8 states starting in the fall of 2014. The study comprises of a baseline phase to determine current levels of compliance with the key energy provisions of the residential building energy code, identify issues, and calculate potential energy savings from improved compliance; a second phase implementing education, training and outreach activities designed to increase targeted code compliance; and a post-study phase to measure the impact of the training and outreach activities compared to the baseline phase. Initial analyses determined the code requirements with the largest energy impact and the minimum number of observations required to detect statistically significant differences in energy use. Data was collected in the field during a single site visit to avoid bias from repeat visits. However, the single site visit principle prevented energy simulation of individual homes due to the lack of all required model inputs. To address this, energy simulation was conducted using Pacific Northwest National Laboratory’s prototype building models and employing bootstrap random sampling on the data collected from all homes visited. The modeled energy consumption using the observed field data was evaluated relative to that associated with the minimum code requirements and potential savings associated with improved compliance of select items were assessed. This paper discusses the methodology developed for this field study, and presents the results and findings from the baseline phase.

Xie, YuLong↗

The interactive indoor-outdoor building energy modeling for enhancing the predictions of urban microclimates and building energy demands

There is a lack of an urban building energy modeling framework that considers the influence of surrounding buildings and local urban climate on building thermal performance. This can lead to inaccurate results since the thermal performance of individual buildings is heavily influenced by their surrounding built and climatic environment. This study establishes an interactive indoor-outdoor building energy modeling method to enhance the predictions of urban microclimates and building energy demands by coupling an urban physics model with a physics-based building energy model. Validation of the interactive coupling scheme uses field measurement datasets. Parametric simulation and analysis are conducted to understand the influence of the roof-to-canyon width ratio, canyon orientation, and ground vegetation fraction on canyon temperature, building energy consumption, and energy demand. Furthermore, the impacts of building energy model complexity (e.g., detailed vs. simplified building models) and coupling approaches on canyon temperature and building energy profiles are demonstrated using two case study buildings. In comparison with the one-way coupling approach, cooling energy consumption predicted with the dynamic two-way coupling approach varies by 3.5% and 0.5% for the detailed medium office building model and high-rise building model, respectively, and peak cooling demand varies by 8.4% and 7.0% for the detailed medium office building model and high-rise building model, respectively. Here this study also suggests that adopting a complex two-way coupling approach with environmental data exchange at various elevations is necessary for modeling tall buildings at the urban scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗