Comparison of time-frequency-analysis techniques applied in building energy data noise cancellation for building load forecasting: A real-building case study

Time-frequency analysis that disaggregates a signal in both time and frequency domain is an important supporting technique for building energy analysis such as noise cancellation in data-driven building load forecasting. There is a gap in the literature related to comparing various time–frequency-analysis techniques, especially discrete wavelet transform (DWT) and empirical mode decomposition (EMD), to guide the selection and tuning of time–frequency-analysis techniques in data-driven building load forecasting. This article provides a framework to conduct a comprehensive comparison among thirteen DWT/EMD techniques with various parameters in a load forecasting modeling task. A real campus building is used as a case study for illustration. The DWT and EMD techniques are also compared under various data-driven modeling algorithms for building load forecasting. The results in the case study show that the load forecasting models trained with noise-cancelled energy data have increased their accuracy to 9.6% on average tested under unseen data. This study also shows that the effectiveness of DWT/EMD techniques depends on the data-driven algorithms used for load forecasting modeling and the training data. Hence, DWT/EMD-based noise cancellation needs customized selection and tuning to optimize their performance for data-driven building load forecasting modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identification of Energy Efficiency Opportunities through Building Data Analysis and Achieving Energy Savings through Improved Controls

This chapter will highlight analysis techniques to identify energy efficiency opportunities to improve operations and controls. A free tool, Energy Charting and Metrics (ECAM), will be used to assist in the analysis of whole-building, sub-metered, and/or data from the building automation system (BAS). Appendix A describes the features of ECAM in more depth, and also provide instructions for downloading ECAM and all resources pertaining to using ECAM.

Katipamula, Srinivas↗

Building Energy Monitoring and Analysis

This project aimed to develop a standard methodology for building energy data definition, collection, presentation, and analysis; apply the developed methods to a standardized energy monitoring platform, including hardware and software, to collect and analyze building energy use data; and compile offline statistical data and online real-time data in both countries for fully understanding the current status of building energy use. This helps decode the driving forces behind the discrepancy of building energy use between the two countries; identify gaps and deficiencies of current building energy monitoring, data collection, and analysis; and create knowledge and tools to collect and analyze good building energy data to provide valuable and actionable information for key stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of building energy use data between the United States and China

Buildings in the United States and China consumed 41percent and 28percent of the total primary energy in 2011, respectively. Good energy data are the cornerstone to understanding building energy performance and supporting research, design, operation, and policy making for low energy buildings. This paper presents initial outcomes from a joint research project under the U.S.-China Clean Energy Research Center for Building Energy Efficiency. The goal is to decode the driving forces behind the discrepancy of building energy use between the two countries; identify gaps and deficiencies of current building energy monitoring, data collection, and analysis; and create knowledge and tools to collect and analyze good building energy data to provide valuable and actionable information for key stakeholders. This paper first reviews and compares several popular existing building energy monitoring systems in both countries. Next a standard energy data model is presented. A detailed, measured building energy data comparison was conducted for a few office buildings in both countries. Finally issues of data collection, quality, sharing, and analysis methods are discussed. It was found that buildings in both countries performed very differently, had potential for deep energy retrofit, but that different efficiency measures should apply.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-Driven Analysis Tool Plays Critical Role in Climate Neutral Buildings: Improving energy efficiency and reducing emissions

A new web application that advances the science of data-driven, remote building energy analysis to increase the speed and scale of retrofits worldwide could play a key role in reducing greenhouse gas (GHG) emissions and meeting the Paris Agreement's targets. Here, the multi-award-winning Building Efficiency Targeting Tool for Energy Retrofits (BETTER) is a public access web application (better.lbl.gov) sponsored by the U.S. Department of Energy (DOE) and developed by Lawrence Berkeley National Laboratory (Berkeley Lab) and Johnson Controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Survey and Analysis of Weather Data for Building Energy Simulations

In recent years, calibrated energy modeling of residential and commercial buildings has gained importance in a retrofit-dominated market. Accurate weather data plays an important role in this calibration process and projected energy savings. It would be ideal to measure weather data at the building location to capture relevant microclimate variation but this is generally considered cost-prohibitive. There are data sources publicly available with high temporal sampling rates but at relatively poor geospatial sampling locations. To overcome this limitation, there are a growing number of service providers that claim to provide real time and historical weather data for 20-35 km2 grid across the globe. Unfortunately, there is limited documentation from 3rd-party sources attesting to the accuracy of this data. This paper compares provided weather characteristics with data collected from a weather station inaccessible to the service providers. Monthly average dry bulb temperature; relative humidity; direct, diffuse and horizontal solar radiation; and wind speed are statistically compared. Moreover, we ascertain the relative contributions of each weather variable and its impact on building loads. Annual simulations are calculated for three different building types, including a closely monitored and automated energy efficient research building. The comparison shows that the difference for an individual variable can be as high as 90%. In addition, annual building energy consumption can vary by 7% while monthly building loads can vary by 40% as a function of the provided location s weather data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy Monitoring and Analysis

U.S. and China are the world’s top two economics. Together they consumed one-third of the world’s primary energy. It is an unprecedented opportunity and challenge for governments, researchers and industries in both countries to join together to address energy issues and global climate change. Such joint collaboration has huge potential in creating new jobs in energy technologies and services. Buildings in the US and China consumed about 40% and 25% of the primary energy in both countries in 2010 respectively. Worldwide, the building sector is the largest contributor to the greenhouse gas emission. Better understanding and improving the energy performance of buildings is a critical step towards sustainable development and mitigation of global climate change. This project aimed to develop a standard methodology for building energy data definition, collection, presentation, and analysis; apply the developed methods to a standardized energy monitoring platform, including hardware and software, to collect and analyze building energy use data; and compile offline statistical data and online real-time data in both countries for fully understanding the current status of building energy use. This helps decode the driving forces behind the discrepancy of building energy use between the two countries; identify gaps and deficiencies of current building energy monitoring, data collection, and analysis; and create knowledge and tools to collect and analyze good building energy data to provide valuable and actionable information for key stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Big Data Mining for Assessing Calibration of Building Energy Models

Residential and commercial buildings in China, India, the United States (US), United Kingdom (UK), and Italy consume 39-45% of each nation's primary energy. Building energy models can be used to automatically optimize the return-on-investment for retrofits to improve a building’s energy efficiency. However, with an average of 3,000 building descriptors necessary to accurately simulate a single building, there is a market need to reduce the transaction cost for creating a more robust model for simulating every building in a city and accurately estimate savings prior to capital expenditures.We used two of the world’s fastest supercomputers, assembled unique datasets, and developed innovative algorithms for big data mining to assess different methods to create an accurate building energy model. The team has leveraged a total of eight high performance computing resources and 218 servers to analyze the best methods, metrics, and algorithms for creating an accurate building energy model beyond current industry standards necessary for private-sector financing. The project developed the world’s fastest buildings simulator, has completed over 8 million simulations totaling over 300TB, and mined this data with over 130,000 parallel artificial intelligence algorithms. This was used to quantify accuracy of AI-developed calibration algorithms with results that surpass industry standard guidelines and can identify individual building parameters to between 15% and 32% of their actual value.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing User Burden in Building Energy Analysis

Infrared (IR) imagery can provide valuable data to building energy auditors and the developers of Building Energy Models (BEM). IR by itself is not a panacea to the challenges facing energy auditors and modelers, but when combined with other techniques and Open Studio software, IR can play an important role in the minimization of the burden of creating building energy models and the diagnosing of building energy problems. While IR can be used to detect and quantify many aspects of a building’s thermal and energy performance, in Phase I we focused on a single capability: determining the R value of exterior walls. Two key attributes of using IR methods for R value determination is that IR methods measure the actual, installed performance in-situ – as opposed to relying on manufacturer or handbook values – and they can integrate performance over a wide area and thus can accurately account for thermal bridging and spatial anomalies such as “spotty” insulation installation. There is a trade between user burden and accuracy when using IR to determine a wall’s R value. The least burdensome approach is computing R values from a single IR snapshot. The most burdensome method we considered was to combine IR images with thermocouple and heat flux sensor (HFS) measurements made over the course of several days. The more effort users expend in making the measurements, the more accurate and robust the method becomes. Through a series of field tests at the ThermoAnalytics Inc. (TAI) HQ at Calumet, MI and a simulation of a 1980s era office building in Flagstaff, AZ we investigated methods to compute the R value of exterior walls using data from IR cameras, thermocouples and heat flux sensors. To compute R values the heat flux through the wall, along with temperatures on either side of the wall, must be known, modeled, or estimated – and the temperature difference through the wall should be at least 10 C. If only outdoor IR images are used in the method, the inside ambient air temperature must be estimated, and a simulation model created to predict heat fluxes and the indoor wall temperature. The accuracy of the resulting R value depends on the accuracy of the simulation and the assumptions it employs. Applying thermocouple sensors, either as iButtons or as part of a wireless sensor network, to the walls allows for the acquisition of temperatures over time. The longer the duration of the measurements, the more accurate and robust the method will be. Even with this level of measurement effort, modeling is still required to calculate the heat flux through the wall. The addition of a heat flux sensor alleviates the need for any modeling, and that results in improved accuracy. Driving the accuracy of the methods are several factors that can be quantified. How well are the wall surface temperatures known? Modeling the heat flux through walls requires knowing the details of the surrounding radiant environment and the heat transfer due to convection. How well are these boundary conditions known? Even when the heat flux is measured, error can arise when some of the measured heat is not conducted through the wall but rather goes into the thermal mass of the wall. Thermal mass effects occur when conditions and the heat flux values are fluctuating. A technique that is not robust will suffer in accuracy when these fluctuations occur. The R value determination method must be incorporated into the Open Studio process. In our proposed process, IR images and other measured sensor data are input into a module that would send R value estimates to a building library developed by team member Skidmore, Owings, & Merrill (SOM). This library of parameterized building models would use these R values along with information about the building’s age, type, and location to query the Open Studio BCL to identify the most likely constructions for walls, roof, and windows. Being based on the IMF feature of Energyplus, the SOM building library can quickly produce Energyplus models of buildings based on a limited number of user inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unique Building Identifier (UBID): Public Sector Implementation Guide

Buildings generate data throughout their lifecycle – about ownership & taxation, usage, zoning, code compliance, energy use, and retrofits. State and local governments collect this data after it flows through growing networks of people and systems. But collecting data is only half the battle; what’s really needed is information – the actionable insights that lead to successful policy outcomes.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

A Method for Integrating an UBEM with GIS for Spatiotemporal Visualization and Analysis

Leveraging Geographic Information Systems (GIS) for spatiotemporal visualization and analysis of simulated UBEM datasets and real-world data simultaneously can assist in identifying opportunities, as well as potential barriers, to energy efficient and climate adaptation strategies. However, current GIS-based models that support interactive exploration of adaptation strategies and future scenarios are scarce and do not easily incorporate building energy use data for visual analysis over time. This paper describes a workflow to integrate simulated building energy consumption data associated with variable energy efficiency scenarios within a GIS platform for interactive spatiotemporal visualization to support climate adaptation decision-making. The contribution of the work presented is in the ability to selectively view and analyze simulated building energy performance data layered with other real-world geospatial data through an automated feedback loop between an UBEM and ArcGIS. An interactive interface is designed in ArcGIS to enable users to explore building performance scenarios spatially and over time. Using a downtown neighborhood in Syracuse, New York, USA, as a case study, preliminary results demonstrate how the workflow provides insight into existing energy use issues and potential for implementing strategies such as energy load shifting or building retrofits. A discussion includes opportunities as well as challenges to the workflow in facilitating understanding of urban energy model outputs by multiple stakeholders in evaluating potential energy efficient strategies.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Data-driven evaluation of HVAC operation and savings in commercial buildings

Commercial buildings consumed 36% of electricity, or 1.35 trillion kWh, in the United States in 2017, and almost 30% of this energy was wasted. Much of this loss can be attributed to inefficient heating ventilation and air con­ditioning (HVAC) systems. By improving the operational conditions of HVAC, significant savings can be achieved. However, most buildings and building equipment do not use costly sub-meters to monitor and address performance issues, and on-site auditing can be expensive and insufficient. Alternatively in this study, we propose a data-driven method to identify savings opportunities using only whole building meter data and without setting foot in the building. For this purpose, we introduced two algorithms that virtually quantify the value of a thermostat setpoint setback and HVAC rescheduling. Additionally, we developed novel methods for detecting occupancy patterns and quantifying the baseload of the HVAC operation. Using a clustering algorithm, we identified those buildings for which HVAC savings was significant and further categorized the buildings based on their potential for savings. A population study of over 432 commercial buildings demonstrated a median percentage energy savings of 1.6% from a baseload reduction and 2.1% from HVAC rescheduling. Additionally, results indicate that retail buildings have the highest potential for savings among the building types studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated pipeline framework for processing of large-scale building energy time series data

Commercial buildings account for one third of the total electricity consumption in the United States and a significant amount of this energy is wasted. Therefore, there is a need for “virtual” energy audits, to identify energy inefficiencies and their associated savings opportunities using methods that can be non-intrusive and automated for application to large populations of buildings. Here we demonstrate virtual energy audits applied to large populations of buildings’ time-series smart-meter data using a systematic approach and a fully automated Building Energy Analytics (BEA) Pipeline that unifies, cleans, stores and analyzes building energy datasets in a non-relational data warehouse for efficient insights and results. This BEA pipeline is based on a custom compute job scheduler for a high performance computing cluster to enable parallel processing of Slurm jobs. Within the analytics pipeline, we introduced a data qualification tool that enhances data quality by fixing common errors, while also detecting abnormalities in a building’s daily operation using hierarchical clustering. We analyze the HVAC scheduling of a population of 816 buildings, using this analytics pipeline, as part of a cross-sectional study. With our approach, this sample of 816 buildings is improved in data quality and is efficiently analyzed in 34 minutes, which is 85 times faster than the time taken by a sequential processing. The analytical results for the HVAC operational hours of these buildings show that among 10 building use types, food sales buildings with 17.75 hours of daily HVAC cooling operation are decent targets for HVAC savings. Overall, this analytics pipeline enables the identification of statistically significant results from population based studies of large numbers of building energy time-series datasets with robust results. These types of BEA studies can explore numerous factors impacting building energy efficiency and virtual building energy audits. This approach enables a new generation of data-driven buildings energy analysis at scale.

36 MATERIALS SCIENCE↗

Data Analysis of Energy Code Compliance in Commercial Buildings

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. The field study team implemented the pilot methodology, compiling a data set of 230 office and retail buildings in two climate zones. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This report is focused on the analysis of the collected data. The primary goal was to analyze the data collected during the field study and determine the actual energy cost impact of each measure in a non-compliance situation. The energy impact results allowed for ranking the measures to identify which have the highest potential for lost savings. These results combined with the time required to verify each measure will allow future compliance verification to focus on measures that had a large impact on energy use over the life of the building and those that have the greatest savings recovery potential per verification hour.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Analysis of Energy Code Compliance in Commercial Buildings (Rev. 1)

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. The field study team implemented the pilot methodology, compiling a data set of 230 office and retail buildings in two climate zones. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This report is focused on the analysis of the collected data. The primary goal was to analyze the data collected during the field study and determine the actual energy cost impact of each measure in a non-compliance situation. The energy impact results allowed for ranking the measures to identify which have the highest potential for lost savings. These results combined with the time required to verify each measure will allow future compliance verification to focus on measures that had a large impact on energy use over the life of the building and those that have the greatest savings recovery potential per verification hour.