Search NASA⌕ Search

SEARCH · Search NASA

Results for “building floors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Terra-Populus v0.1: A Python Library for LandScan High-Definition Population Analysis and Modeling

The terra-populus library is designed for use by the LandScan HD technical team, offering a streamlined set of tools for generating and updating LandScan HD datasets from foundational building-level data, referred to as 'molecules,' provided by the building-level attribution team. This document serves as the primary technical documentation for terra-populus. Version 0.1 of the library includes the core modeling components necessary for LandScan HD production. It enables the generation of the LandScan HD Baseline dataset as well as corresponding confidence measures for the occupancy rates used. Parameters have been included for incorporating damaged building indicators and changes in population, to faciliate the creation of rapid updates for LandScan HD. Future iterations of terra-populus will introduce tools for creating a confidence index, and quantifying and propagating uncertainty, facilitating the creation of probabilistic LandScan HD outputs. This report provides an overview of the tools available in the library and the corresponding code implementations. One of the key advancements implemented in terra-populus is a redefinition of the atomic modeling unit for LandScan HD. Traditionally, the LandScan HD vector analytical framework has generated population estimates at the building sub-component (molecule) level. However, terra-populus adopts a building-level modeling approach. This shift is an operational decision aimed at aligning LandScan HD outputs with confidence measures, which are computed and validated at the building level (confidence measures are not included in this version of terra-populus, aside from those associated with the occupancy rates). Additional advancements to the LandScan HD modeling, as implemented by terra-populus, include a minimum population value parameter and an auto assignment of building floor counts. The population minimum value was implemented to prevent buildings and subsequent LandScan HD pixels that contained small values that may not rasterize in production. An 'auto' value has been included as a method for dealing with buildings lacking floor count information, where it is the average floor count of all other buildings with a residential building use type tag. The logic behind this is to remain consistent with the current logic employed for dealing with building use type null instances, where a null use type is defaulted to residential since it is the most common building type. The auto logic is intended to apply the most common building floor count of the most common type of buildings. The tools provided in terra-populus represent a significant step forward in improving the efficiency, reproducibility, and transparency of the LandScan HD modeling process. As the library evolves, it will continue to serve as a foundational resource for high-resolution population modeling.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Updated OpenStudio Small and Medium Office Prototype Models

The U.S. Department of Energy supports the development of commercial building energy codes and standards by participating in industry review, update processes, and providing technical analyses to support both published model codes and potential changes. In support of ANSI/ASHRAE/IES Standard 90.1 and International Energy Conservation Code, 16 commercial prototype building models were developed that cover 80% of the commercial building floor area in the United States for new construction, including both commercial buildings and mid- to high-rise residential buildings, across all U.S. climate zones. Of these, the small, medium, and large office buildings take about 12% of total commercial building floor area.Currently, small, medium, and large office prototype building models have simplified, single space type, while other building types includes more detailed space types. As such, the office prototype could not be easily used to properly assess changes (i.e. measures applied) to difference spaces commonly found in an office. This work has added new space types to the small and medium office, with properties based on several vintages of ASHRAE Standard 90.1 in different climate zones, and compared energy use of these newly-improved models with that of the original models.

Im, Piljae↗

Prototype Courthouse Building Energy Model: Building and System Characteristics

As part of the Department of Energy’s support of ANSI/ASHRAE/IES Standard 90.1 and the International Energy Conservation Code, researchers at Pacific Northwest National Laboratory apply a suite of prototype buildings covering 80% of the commercial building floor area in the United States for new construction. Efforts have begun to cover 90% of the commercial building floor area in the United States by developing prototype models for additional building types that include supermarket, laboratory, place of worship, public order and safety, and public assembly. “Courthouse” is a subcategory under the “Public Order and Safety” building type category defined by the Commercial Buildings Energy Consumption Survey (CBECS); other subcategories include police station, fire station, and detention and correctional facilities (i.e., jail, reformatory, or penitentiary). Oak Ridge National Laboratory used building design guides, databases, and documented courthouse projects, supplemented by personal communication with courthouse facility planning and design experts, to systematically conduct research on the courthouse building and system characteristics. This report documents this research and reports the building and system characteristics necessary for developing a Courthouse prototype building energy model to be included in the Commercial Building Prototype Model suite.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Defining the Prototype Convenience Store Building Characteristics

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 30 prototype building models (20 different building types), which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). This report documents the building and system characteristics of the prototype convenience store building model. Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype convenience store building characteristics, and a one-story, 3,000 ft 2 building was considered as the prototype convenience store to represent an average-sized convenience store in the United States. The Oak Ridge National Laboratory team defined the operational hours of the convenience store as 17 hours per day. The types of exterior walls, roof, and floor were defined as brick wall, metal surfacing roof, and slab-on-grade floor, respectively. Double glazing was selected, and the window-towall ratio was set as 15% on the front side. For the system part, packaged system and centralized water heater were selected for the space heating and cooling system and water heater system, respectively. In terms of the refrigerator system, the number of refrigerators and freezers were determined as eight closed cases and two walk-in units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How Can Floor Covering Influence Buildings’ Demand Flexibility?

Although the thermal mass of floors in buildings has been demonstrated to help shift cooling load, there is still a lack of information about how floor covering can influence the floor’s load shifting capability and buildings’ demand flexibility. To fill this gap, we estimated demand flexibility based on the daily peak cooling load reduction for different floor configurations and regions, using EnergyPlus simulations. As a demand response strategy, we used precooling and global temperature adjustment. The result demonstrated an adverse impact of floor covering on the building’s demand flexibility. Specifically, under the same demand response strategy, the daily peak cooling load reductions were up to 20–34% for a concrete floor whereas they were only 17–29% for a carpet-covered concrete floor. This is because floor covering hinders convective coupling between the concrete floor surface and the zone air and reduces radiative heat transfer between the concrete floor surface and the surrounding environment. In hot climates such as Phoenix, floor covering almost negated the concrete floor’s load shifting capability and yielded low demand flexibility as a wood floor, representing low thermal mass. Sensitivity analyses showed that floor covering’s effects can be more profound with a larger carpet-covered area, a greater temperature adjustment depth, or a higher radiant heat gain. With this effect ignored for a given building, its demand flexibility would be overestimated, which could prevent grid operators from obtaining sufficient demand flexibility to maintain a grid. Our findings also imply that for more efficient grid-interactive buildings, a traditional standard for floor design could be modified with increasing renewable penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototype College Building Energy Model: Building Characteristics and Energy Simulation Results

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 16 prototype building models, which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype college building, and a 4-story with 69,063 ft 2 building was considered as the prototype college building to represent an average-sized college building in the United States. To represent realistic occupancy schedules and increase the granularity of information, actual class reservation schedules were collected and used. This report documents the building and system characteristics of the prototype college building model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. The site energy use intensity of the college building was compared with 2012 Commercial Building Energy Consumption Survey (CBECS) and ENERGY STAR data to verify the simulation results. The site energy use intensity of the college building ranged from 60 to 202.4 kBtu/ft 2 , and compared with the energy use intensities of Commercial Building Energy Consumption Survey (122.9 kBtu/ft 2 ) and ENERGY STAR (84.3 kBtu/ft 2 ) data, the prototype college building results are in a reasonable range.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An analysis of Potential Benefits of Adding Diurnal Thermal Storage in Geothermal Heat Pump Systems

Geothermal heat pumps (GHP) are highly efficient for space heating and cooling, utilizing the subsurface of the ground as seasonal energy storage through borehole heat exchangers (i.e., heat stored in summer is used to provide heating in winter, and cold stored in winter is used to provide cooling in summer). On the other hand, diurnal thermal energy storage can actively be charged and discharged for load shifting. Conventional thermal energy storage uses tanks filled with thermal storage media (such as phase change materials) and heat exchangers. It occupies building floor space or land areas outside the building, which may not be available especially in residential buildings. This paper will introduce a novel configuration that can utilize existing GHP system for both diurnal and seasonal thermal storage. This system can actively charge the ground on daily basis by injecting heat or cold in borehole heat exchangers. A simulation model was created for the novel configuration. Computer simulations were conducted using the model for the new GHP system serving a typical single-family house in three U.S. cities representing hot, warm, and cold climates. Based on simulation results, the potential benefits of load shifting and downsize of the expensive ground heat exchangers used by the GHP system were assessed.

Anees, Fady [ORNL]↗

Systematic approach to define a prototype building model: Convenience Store

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities, continuous efforts have been made to convert 30 prototype building models, which cover 80% of commercial building floor space in the United States, into OpenStudio Standards prototype buildings. In this paper, we provide a systematic approach to define the building and system characteristics of a convenience store, which has the largest energy use intensity among the commercial building types not covered by current prototype models. This study will be used as a basis for developing the prototype convenience store building model.

Yoon, Yeobeom↗

Surrogate modelling for urban building energy simulation based on the bidirectional long short-term memory model

Here, the urban microclimate is essential for accurate simulation-based urban building energy modelling (UBEM). However, a high spatial-resolution microclimate can increase the computational resources demands of UBEM. Surrogate modelling is one of the promising approaches for fast UBEM. This study proposes a bidirectional Long Short-Term Memory (LSTM)-based approach for simulation-based UBEM surrogate modelling. The estimations are aggregated into census tracts using total building floor area. A case study using UBEM to estimate annual hourly building energy use and anthropogenic heat from all existing buildings in Los Angeles County found that most of the surrogate models can complete the annual hourly simulation within 90 minutes with a normalized mean absolute error lower than 10%, and that the bidirectional LSTM outperforms the standard LSTM in accuracy. This study demonstrates the advantages of bidirectional RNN architecture in building energy surrogate modelling and is expected to promote long-term and high-resolution UBEM with detailed microclimates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Supermarket Prototype Building Model

The U.S. Department of Energy supports the development of commercial building energy codes and standards by participating in industry reviews, update processes, and providing technical analyses to support both published model codes and potential changes. In support of ANSI/ASHRAE/IES Standard 90.1 and the International Energy Conservation Code, 16 commercial prototype building models were developed that cover 80% of the commercial building floor area in the United States for new construction, including both commercial buildings and mid- to high-rise residential buildings, across all U.S. climate zones. However, the current set of commercial prototype building models does not include a supermarket building type, which is one of major building types defined in the Energy Information Administration’s Commercial Building Energy Consumption Survey. As part of an ongoing effort to expand the current Commercial Building Prototype Model suite, this paper presents the procedure used to develop the prototype supermarket building model based on multiple studies as well as a previously developed reference building model. The final set of prototype models includes 68 models for different vintages of ASHRAE Standard 90.1 (i.e., 2004, 2007, 2010, and 2013) and for 17 ASHRAE climate zones.

Im, Piljae↗

Prototype Supermarket Building Energy Model

The U.S. Department of Energy supports the development of commercial building energy codes and standards by participating in industry reviews, update processes, and providing technical analyses to support both published model codes and potential changes. In support of ANSI/ASHRAE/IES Standard 90.1 and the International Energy Conservation Code, 16 commercial prototype building models were developed that cover 80% of the commercial building floor area in the United States for new construction, including both commercial buildings and mid- to high-rise residential buildings, across all U.S. climate zones. However, the current set of commercial prototype building models does not include a supermarket building type, which is one of major building types defined in the Energy Information Administration’s Commercial Building Energy Consumption Survey. As part of an ongoing effort to expand the current Commercial Building Prototype Model suite, this report presents the procedure used to develop the prototype supermarket building model based on multiple studies as well as a previously developed reference building model. The final set of prototype models includes 60 models for different vintages of ASHRAE Standard 90.1 (i.e., 2004, 2007, 2010, and 2013) and for 15 ASHRAE climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Evaluation of the Performance of the RTU Challenge Unit: Daikin Rebel

Packaged rooftop air-conditioning units (RTUs) are used in 44% (2.5 million) of all commercial buildings, serving over 57% (46 billion square feet) of the commercial building floor space in the United States (EIA 2012). The primary energy consumption associated with RTUs is over 2.2 quads annually. Therefore, even a small improvement in efficiency or part-load operation of these units can lead to significant reductions in energy use and carbon emissions. Starting in 2011, the U.S. Department of Energy’s (DOE’s) Building Technologies Office funded a series of projects related to RTUs. Some projects were intended to improve the operating efficiency of the existing RTUs, while others were focused on improving the operating efficiency of new units. This report documents the field-testing and comparison of the seasonal efficiency of a state-of-art RTU Challenge unit and a standard unit. Section II provides the background for the work. Section III describes the measurement and verification plan for the field tests. Section IV describes the measurement and verification evaluation plan. The results are described in Section V. The lessons learned and recommendations for future work are presented in Section VI. A list of references is provided in Section VII.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid Cost and Total Emissions Reductions Through Mass Deployment of Geothermal Heat Pumps for Building Heating and Cooling Electrification in the United States

This report presents the results of a study on the potential grid impacts of national-scale mass deployment of geothermal heat pumps (GHPs) coupled with weatherization in single-family homes (SFHs) from 2022 to 2050. GHPs are a technology readiness level 10, commercially available technology across the United States. This study is an impact analysis only; installed costs and available land areas for installing GHPs are not accounted for in determining their estimated deployment. The three scenarios studied were (1) continuing to operate the grid as it is today (the Base scenario), (2) a scenario to reach 95% grid emissions reductions by 2035 and 100% clean electricity by 2050 (the Grid Decarbonization scenario), and (3) a scenario in which the Grid Decarbonization scenario is expanded to include the electrification of wide portions of the economy, including building heating (the Electrification Futures Study or EFS scenario). The analysis team modeled each of these three scenarios with and without GHP deployment to a large percentage of US building floor space. In all cases, deployment of approximately 5 million GHPs per year demonstrated system cost savings on the grid, consumer fuel cost savings through eliminated fuel combustion for space heating, and CO 2 emission reductions from avoided on-site fuel combustion—and, in the case of the Base scenario, CO 2 emissions reductions from the electric power sector. GHPs have traditionally been viewed as a building energy technology. The most notable result of this study, however, is the demonstration that GHPs coupled with weatherization in SFHs are primarily a grid cost reduction tool and technology that, when deployed at a national scale, also substantially reduces CO 2 emissions, even in the absence of any other decarbonization policy.

15 GEOTHERMAL ENERGY↗

Impact of post-rainfall evaporation from porous roof tiles on building cooling load in subtropical China

Rainfall occurs frequently in subtropical regions of China, with the subsequent water evaporation from building roofs impacting the thermal performance and the energy consumption of buildings. In this paper, we proposed a novel simulation method using actual meteorological data to evaluate this impact. New features were developed in EnergyPlus to enable the simulation: (1) an evaporation latent heat flux source term was added to the heat balance equation of the external surface and (2) algorithms for the evaporative cooling module (ECM) were developed and implemented into EnergyPlus. The ECM experimental results showed good agreement with the simulated results. The ECM was used to assess the impact of evaporation from porous roof tiles on the cooling load of a one-floor building in subtropical China. The results show that the evaporation process decreased the maximal values of the external and internal roof surface temperatures by up to 6.4 °C and 3.2 °C, respectively, while the lower internal surface temperature decreased the room accumulated cooling load by up to 14.8% during the hot summer period. Lastly, the enhanced EnergyPlus capability can be used to evaluate the evaporative cooling performance of roofs with water-storage mediums, as well as to quantify their impact on building cooling loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long and Winding Road to Higher Efficiency-The RTU Story: Preprint

Rooftop units (RTUs) and other packaged heating, ventilating, and air-conditioning (HVAC) equipment consume more than four quads of energy annually while conditioning more than 50% of the commercial building floor area in the United States. Historically, these systems have low operating efficiencies and receive infrequent maintenance. In addition, the market has a low first cost, run-to-failure, like-for-like replacement mentality and has been slow to adopt change. This paper explores the broad market transformation that has resulted in higher efficiencies and tremendous energy savings. Although there are many factors in this market transformation, this paper highlights: research behind advancements in components and controls; adoption of an operational efficiency metric; raising the bar for high efficiency with the RTU Challenge; market barriers overcome through the Advanced RTU Campaign; upstream and midstream incentive programs and HVAC distribution networks; alignment of the market efficiency drivers of ASHRAE Standard 90.1, federal minimum efficiency standards, the ENERGY STAR® program, and the Consortium for Energy Efficiency's (CEE's) efficiency tiers. Measures of the market transformation include more than 50% increase in RTU efficiencies, more than 1 billion kWh saved and 160,000 RTUs upgraded with high-efficiency measures by the Advanced RTU Campaign partners, large increases of high-efficiency RTUs purchased through incentive programs, and the largest energy savings from any federal minimum standards action. Although these results are impressive, the market transformation is just beginning, and there remain exciting opportunities for improvements in equipment efficiencies and improved operating performance with advanced controls and fault detection and diagnostics.

30 DIRECT ENERGY CONVERSION↗

Multifamily Programmable Thermostat Data

This data set, compiled by the Fraunhofer Center for Sustainable Energy Systems, includes long-term 10-minute temperature and relative humidity data, and HVAC system state data for 79 apartments in a low-income housing complex in Revere, MA. The monitoring period spans two winters and one summer between 2011 and 2013. Data were collected as part of a project sponsored by the U.S. Department of Energy Building America program to evaluate the impact of programmable thermostat usability on occupant behavior. This project was done in conjunction with NREL as part of the US Department of Energy's Building America program.

Array↗

A novel approach to criticality accident detection for a legacy facility

For operations on the Sellafield site involving fissile material a Criticality Accident Alarm System (CAAS) has traditionally been installed unless an omission case can be made. An omission case would examine if, in the absence of all controls, a criticality could reasonably be expected or whether the potential dose to an operator would remain below a maximum acceptable dose. It is a UK legal requirement for adequate emergency arrangements to be in place for hazards on a nuclear licensed site. For facilities where criticality is credible there is a regulatory expectation that a -Criticality Warning System- should be in place. A -Criticality Warning System- is not necessarily a full CAAS and alternative means of criticality detection may be part of an adequate emergency plan. The Sellafield site has a Magnox fuel reprocessing facility which has been operated since the 1960's. Evaporation of the Medium Active (MA) liquid waste from this process is undertaken in an associated building. Following extensive review of the plant and process a number of maloperations which can route fissile material to the MA evaporator were identified. Adequate controls to prevent these scenarios were shown to be in place. In the unlikely event of a failure of controls leading to sustained loss of fissile material a criticality incident may occur and hence an emergency plan was determined to be necessary. The novel emergency arrangements which were developed utilized the existing gamma monitor network located across multiple building floors. These gamma monitors are present for radiological safety. This emergency arrangement would require rapid interpretation of the gamma alarms by an operator and the manual triggering of a criticality evacuation alarm. The gamma monitors were demonstrated to be able to detect the minimum incident of concern (10{sup 15} fissions) as well as being able to alarm during the ramp up in power of a large criticality incident (10{sup 18} fissions). It was shown that a criticality accident could readily be distinguished from a radiological event (e.g. loss of containment). To support this work, criticality excursion analysis was used to examine the likely characteristics of a criticality in the MA evaporator. This novel arrangement was justified due to a number of factors including: the limited remaining operational lifetime of this facility (<5 years), the low frequency of maloperation coupled with a failure of controls and the crucial risk reduction provided by the continued reprocessing of Magnox fuel. Furthermore, the time and cost involved with design and installation of a standard CAAS would be substantially greater than a plan based upon existing instrumentation. These arguments were accepted by the UK regulator the Office for Nuclear Regulation (ONR). (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗