Trident Laser Building Layout
This is a picture of the Trident Laser Building layout and other descriptors.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This is a picture of the Trident Laser Building layout and other descriptors.
Los Alamos National Laboratory (LANL, the Laboratory, or the Lab) conducts familiarization tours for Los Alamos County Fire Department (LAFD) personnel at the Strategic Computing Complex (SCC), TA-03-2327, and the Nonproliferation & International Security Complex (NISC), TA-03-2322. These tours are official LANL business; their purpose is to orient the firefighters to the SCC and the NISC so that they can respond efficiently and quickly to a variety of emergency situations. The tour includes ingress and egress of the buildings, layout and organization of the buildings, evacuation procedures, and areas of concern to emergency responders within these buildings. LAFD firefighters have the training, skills, and abilities to perform these emergency responder tasks; other LANL personnel who have the required clearance level cannot perform these tasks. This handout provides details of the information, along with maps and diagrams, to be presented during the familiarization tours. The report will be distributed to the trainees at the time of the tour. A corresponding checklist will also be used as guidance during the familiarization tours to ensure that all required information is presented to the LAFD personnel.
Los Alamos National Laboratory (LANL) will conduct familiarization tours for personnel of the Los Alamos County Fire Department (LAFD) at TA-16 high explosives (HE) facilities. These familiarization tours are official LANL business; the purpose of these tours is to orient LAFD firefighters to the facility so that they can respond efficiently and quickly to a variety of emergency situations. This orientation includes, among other topics, ingress and egress of the area and buildings, layout and organization of the facility, evacuation procedures and assembly points, and areas of concern within the various buildings at the facility. LAFD firefighters have the skills and abilities to perform firefighting operations and other emergency response tasks that cannot be provided by LANL personnel who have the required clearance. This handout provides details of the information, along with maps and diagrams, to be presented during the familiarization tours. The handout will be distributed to the trainees at the time of the tour. A corresponding checklist will also be used as guidance during the familiarization tours to ensure that all required information is presented to LAFD personnel.
Los Alamos National Laboratory (LANL) will conduct familiarization tours for Los Alamos County Fire Department (LAFD) personnel at the Plutonium Facility (PF-4) at Technical Area (TA)-55. These familiarization tours are official LANL business; the purpose of these tours is to orient the firefighters to the facility so that they can respond efficiently and quickly to a variety of emergency situations. This orientation includes the ingress and egress of the area and buildings, layout and organization of the facility, evacuation procedures and assembly points, and areas of concern within the various buildings at the facility. LAFD firefighters have the skills and abilities to perform firefighting operations and other emergency response tasks that cannot be provided by other LANL personnel who have the required clearance level. This handout provides details of the information, along with maps and diagrams, to be presented during the familiarization tours. The handout will be distributed to the trainees at the time of the tour. A corresponding checklist will also be used as guidance during the familiarization tours to ensure that all required information is presented to LAFD personnel.
Los Alamos National Laboratory (LANL) conducts familiarization tours for personnel of the Los Alamos County Fire Department (LAFD) at the RLUOB/CUB, technical area (TA)-55, 400/440, facility, Radiological Laboratory Utility Office Building (RLUOB)/Central Utility Building (CUB). These familiarization tours are official LANL business; the purpose of these tours is to orient LAFD firefighters to the facility so that they can respond efficiently and quickly to a variety of emergency situations. This orientation includes, among other topics, the ingress and egress of the area and buildings, layout and organization of the facility, evacuation procedures and assembly points, and areas of concern within the various buildings at the facility. LAFD firefighters have the skills and abilities to perform firefighting operations and other emergency response tasks that cannot be provided by other LANL personnel who have the required clearance level. This handout provides details of the information, along with maps and diagrams, to be presented during the familiarization tours. The handout is distributed to the trainees at the time of the tour; a corresponding checklist is also used as guidance during the familiarization tours to ensure that all required information is presented to LAFD personnel.
Los Alamos National Laboratory (LANL) will conduct familiarization tours for personnel of the Los Alamos County Fire Department (LAFD) at the TA-55 General Facility. These familiarization tours are official LANL business; the purpose of these tours is to orient LAFD firefighters to the facility so that they can respond efficiently and quickly to a variety of emergency situations. This orientation includes, among other topics, ingress and egress of the area and buildings, layout and organization of the facility, evacuation procedures and assembly points, and areas of concern within the various buildings at the facility. LAFD firefighters have the skills and abilities to perform firefighting operations and other emergency response tasks that cannot be provided by LANL personnel who have the required clearance level. This handout provides details of the information, along with maps and diagrams, to be presented during the familiarization tours. The handout will be distributed to the trainees at the time of the tour. A corresponding checklist will also be used as guidance during the familiarization tours to ensure that all required information is presented to LAFD personnel.
Microreactors are a novel class of nuclear reactors that are expected to be factory produced, transportable, and self-regulating. They are expected to be several orders of magnitude smaller in size than traditional reactors (with power outputs in the 1–20 MWe range typically). They are primarily envisaged to target niche, remote markets that are difficult to access and where energy costs are high. There has been a scarcity of technoeconomic assessment for these types of reactors due to the scarcity of designs without proprietary restraints (e.g., those that include balance of plants and building layouts) and cost estimates. The primary objective of this report was to develop a transparent, detailed, bottom-up cost estimate for a microreactor. While there is a high degree of uncertainty associated with the projected costs, this work provides a foundation that can built upon and improved to better model the economics of microreactors. The Microreactor Applications Research, Validation, and Evaluation (MARVEL) microreactor was selected for this analysis. This Department of Energy–sponsored demonstration was chosen because (1) its final design was recently completed and (2) a detailed class-3 cost-and-schedule estimation was conducted for it. This provided a strong technical basis for further analysis.
In order to begin decommissioning of a 1950's research reactor, Class C Mixed Low Level Waste (MLLW) had to be removed from the facility and disposed of. The AREVA TN RAM cask, designed and licensed for shipping Type B waste packages, was chosen as the most appropriate shipping solution. Due to the building layout, crane capacity and pool size, the standard TN RAM cask loading process could not be utilized. Unique solutions and approaches had to be developed to complete the project. AREVA designed a smaller liner insert that would house the four MLLW components in a single waste package to solve the problems related to crane capacity and physical pool dimensions. AREVA also designed and fabricated a shield bell to provide radiation shielding while moving the liner insert from the reactor pool to the cask that was staged adjacent to the reactor pool. The AREVA team worked with the disposal facility to cover requirements for disposal of Class B MLLW. This included designing spacers filled with inert material to fulfill the requirement for maximum 10% void space in the waste package. This disposal method for Class C waste met the requirements of macro-encapsulation. Therefore, no additional treatment action was required when disposing of Class C MLLW. AREVA's solution provides a model for disposing MLLW requiring macro-encapsulation in a single waste package. This solution also provides a model for how to adapt large shipping casks and liners to smaller aging commercial, DOE or research facilities. (authors)
The control room radiological habitability is important for staff safety in nuclear power plant accident, which is also a licensing requirement of the High Temperature Reactor Pebble Bed Module (HTR-PM) in China. In this study, a comprehensive evaluation of the control room radiological habitability is performed for three design basis accident scenario of HTR-PM. For each scenario, three exposure pathways are taken into account, which includes the immersion external exposure, the inhalation exposure and the direct exposure from radioactive cloud in the environment. The atmospheric concentration is calculated using the NRC-recommended ARCON96 code, based on the two-year meteorological observation data at HTR-PM s site and the final building layout. The evaluation result demonstrates that the individual dose level of staffs in the control room is far below the requirement of the regulatory, which guarantees the radiological habitability of control room of HTR-PM. The contribution of each radionuclide has been analyzed, which suggests that iodine and metal radionuclides such as Cs-137 and Co-60 are primary contributor of the total dose, which are worthy of particular attention in the control room habitability design. (authors)
Building envelope retrofits, despite their benefits on enhancing energy efficiency, progress slowly due to high operating costs. Overclad panelized systems present an attractive solution to make retrofits affordable and easy to install. However, several stages of the retrofit process remain disconnected, suboptimal, and require significant human intervention. This study aims to bridge the gap between digital twin generation and overclad panel installation by automating the design of an optimal panel layout directly from a building envelope point cloud. In this end-to-end approach, the dimensional twin is generated by segmenting the facade point cloud. The facade then undergoes a three-step process to generate an optimized panel layout for integration with automated placement systems.
Fifth generation district heating and cooling networks are characterized by supply temperatures in the ambient range of 15-25 degrees C, which not only reduces heat loss but also allows for integrating various kinds of low-temperature waste heat sources. The ability of these networks to absorb waste heat that is normally unrecoverable makes them an attractive solution for the future energy supply of urban areas. To enhance the adoption of these networks, this paper describes the development of a software tool to analyze the feasibility of fifth-generation of district heating and cooling systems in both new and existing districts. The research attempts to answer the question: 'Which buildings should be connected to a low-temperature hydraulic network given both the incremental benefits and costs relative to the scenario of decentralized (dedicated) heating and cooling systems for each building?' Therefore, all possible network layouts of the buildings are considered where the heating and cooling demands of each building are met by the fifth-generation of district heating and cooling network. For the heating and cooling load characterization of the buildings, reduced-order models are used while renewable energy and waste heat sources are included in the network. The focus of the research lies in the development of a hydraulic model for flexible use in the urban energy modeling and the optimization of the fifth-generation of district heating and cooling network topology for a given urban district. This research displays simulation results that quantify the performance of the fifth-generation of district heating and cooling network based on various output metrics, including primary energy usage, carbon dioxide emissions, and network implementation cost.
We looked to build a new type of 100 kV pulse generator that we hope will avoid many of the problems seen with other commercially available pulse generators. We looked to exploit recent improvements in both lasers and solid-state pulse charge units along with an alternative triggering layout to build something new. For the pulse charging unit, we collaborated with Texas Tech to leverage their knowledge and expertise in pulse transformers and solid-state switching. The final result of the LDRD looks promising. Texas Tech was able to build a pulse charge unit that meets our specifications regarding output, and we were able to integrate it with a switch and a laser to create a device that meets the goals of the LDRD. There is still much work to do to advance the design further and improve reliability, but the proto-type design satisfies the goals we set for this LDRD.
The prototype laboratory concept was developed to simplify the laboratory design process, and should be considered for use as a new laboratory design methodology. Many developing countries lack adequate public and animal health laboratories and typically do not have the economic means and the design and construction expertise to build a laboratory on their own. These countries rely on international sponsors to provide the funds necessary to design and construct a laboratory. However, these international sponsors are often located far away, making travel back and forth difficult, which leads to an increase in overall costs and delays for the project. The prototype laboratory concept and design methodology were developed to streamline the design process, saving time and money, while also minimizing the number of errors that typically arise using a traditional design process by providing well considered design decisions in advance of the project. By solving numerous detailed design issues early, this methodology will allow the time, attention and energies of the design team to be focused on addressing the specific needs of the end users, the unique design challenges related to a given site and scientific program, and the biosafety and biosecurity risks associated with the scientific activities planned to be conducted in the facility. While the concept could be expanded to cover other types of laboratories to date, it has primarily focused on supporting the implementation of good laboratory design best practices for infectious disease diagnostic and research laboratories for both the human and animal health sectors. This report presents the laboratory design concept and details associated with the modular layouts. It builds on the work previously provided in the interim prototype laboratory concept report delivered to the Cooperative Biological Engagement Program (CBEP) at the Defense Threat Reduction Agency (DTRA) in 2014. This report includes a number of revised and additional module layouts, more detailed information regarding laboratory finishes and equipment, engineering service information, electrical and lighting layouts, plumbing service information and two mechanical service options for each prototype module. Additionally, this report also includes a description of a cost estimating tool that will accompany this report and allow funding agencies to generate an approximate cost for the construction of a laboratory that utilizes the prototype laboratory concept modules. This report is intended to serve a complete document and includes all relevant information from the 2014 prototype laboratory concept report.
This deliverable reports FY26 progress in advancing a neural-network-based Green’s-function framework for reconstructing neutron-flux distributions from ex-core measurements and for translating reconstruction requirements into a practical detector-layout strategy. Building on the FY25 formulation, the present work had two main objectives: (1) refine and re-evaluate the reconstruction methodology on an updated Purdue University Reactor Number One (PUR-1) model, and (2) develop a systematic, Green’s-function-guided procedure for boundary detector placement.
This data set, compiled by the Fraunhofer Center for Sustainable Energy Systems, includes long-term 10-minute temperature and relative humidity data, and HVAC system state data for 79 apartments in a low-income housing complex in Revere, MA. The monitoring period spans two winters and one summer between 2011 and 2013. Data were collected as part of a project sponsored by the U.S. Department of Energy Building America program to evaluate the impact of programmable thermostat usability on occupant behavior. This project was done in conjunction with NREL as part of the US Department of Energy's Building America program.
The NASA Ames Mission Design Center (MDC) has undergone a significant transformation process in recent years, culminating in becoming a true Concurrent Engineering Center. The underlying goal of this transformation is to better serve the Ames PI community in a cost-effective and rapidly-responsive way, providing quality products pivotal to the decision-making proposal strategy of our center. The four pillars of the change focus on four areas: personnel, physical places, tools, and training. Personnel: the MDC switched from using a dedicated pool of engineers—mostly entry-level career—for a matrixed approach with more experienced Subject Matter Experts, usually involved in spaceflight projects. These SMEs get detailed to the MDC for the duration of the study on a part-time or full-time basis. Physical places: The physical aspect pertains mostly to the layout of the new Engineering building and the dedicated concurrent engineering layout to foster collaboration. The current plan includes a dedicated space for concurrent engineering sessions as well as dedicated project rooms for concept studies. Tool: the MDC team is developing a new in-house concurrent engineering tool to facilitate concurrent engineering sessions. The team leveraged the many lessons learned and insight gained from using the current concurrent engineering tool, in use since 2007. SMEs have been involved throughout its design and development, ensuring accuracy and providing validity to the implementation approach. This new tool is database-driven and allows a team to work concurrently on the same model of a mission concept. “Workspaces” are provided for each of the traditional spacecraft mission design disciplines, including cost accounting and systems engineering. There are multiple tiers of fidelity available within each workspace, which can be completed parametrically or independently from the other disciplines as needed or synchronously with the other disciplines. A “commit” step synchronizes a workspace with the mission database and identifies any potential conflicts, along with the user who entered the conflicting data. A Mission Summary workspace enables a Study Lead to run an effective CE session, displaying key graphics, workspace status information, and technical and monetary budget information. This new CE tool will be undergoing Beta Testing with its primary user base and a limited Parts database in the summer of 2020. The team plans to release the first fully operational version in December 2020. Training: working in early concept development and maturation for a space mission requires a unique mindset and being comfortable with uncertainties in an environment where requirements are not yet fully developed, and where changes and trade-offs happen at a high tempo. The MDC started a weekly training program to ensure a common knowledge base on how do develop and mature early concept studies, as well as how to operate in a concurrent engineering environment. In conclusion, the MDC transformation will provide the overall PI community focused on cost-effective small satellite scientific missions with a powerful tool to address and mature early concepts more effectively and efficiently.
NREL worked with the Bonneville Power Administration's Technology Innovation Office to demonstrate a turnkey, retrofit technology that combines demand response (DR) and energy efficiency (EE) benefits for HVAC and lighting in retail buildings. As a secondary benefit, we also controlled various plug loads and electric hot water heaters (EHWH). The technology demonstrated was Transformative Wave's eIQ Building Management System (BMS) automatically responding to DR signals. The BMS controlled the HVAC rooftop units (RTU) using the CATALYST retrofit solution also developed by Transformative Wave. The non-HVAC loads were controlled using both hardwired and ZigBee wireless communication. The wireless controllers, manufactured by Autani, were used when the building's electrical layout was too disorganized to leverage less expensive hardwired control. The six demonstration locations are within the Seattle metro area. Based on the assets curtailed by the BMS at each location, we projected the DR resource. We were targeting a 1.7 W/ft2 shed for the summer Day-Ahead events and a 0.7 W/ft2 shed for the winter events. While summarized in Table ES-1, only one summer DR event was conducted at Casino #2.
The cost of several circuit configurations for large (5MW) array fields were investigated to assess the relative costs of high and low voltage configurations. Three source circuit NOC voltages were evaluated: 400V (ungrounded), 800V (+ or 400V center grounded), and 2000V (+ or - 1000V center grounded). Four source circuit configurations were considered for each of the three NOC voltages. The configurations correspond to source circuit currents of 15, 30, 45, and 60 amperes, respectively. Conceptual layouts for 5MW building blocks for each of the above configurations were developed. The designs were optimized to minimize BOS electrical and structural costs. Only the BOS electrical costs were evaluated. The designs were broken down into the following elements for cost: (1) basic source circuit intermodule wiring, bypass diodes and associated hardware, source circuit to J-Box wiring, etc; (2) J-Box blocking diodes, varistors, heat sinks, and housing; (3) disconnects source circuit disconnects, fuses, and housing; (4) bus cabling J-Box to PCU interface wiring, and trenching; (5) interface bus bar, group disconnects, and fuses; and (6) fault detection shunts, signal wire, electronics, and alarm. It is concluded that high voltage low current circuits are not economical, at higher currents high and low voltage circuit costs approach each other, high voltage circuits are not likely to offer near term advantage, and development work/manufacturer stimulation is needed to develop low cost high voltage hardware.