Search NASA⌕ Search

SEARCH · Search NASA

Results for “bulk techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Melt Growth of a Nonlinear Optical Crystal Triethylphosphine Sulfide using Modified Bridgman-Stockbarger Technique

Bulk single crystals of triethylphosphine sulfide (C2H5)3P(S), a potential nonlinear optical organic material has been grown from melt using Bridgman- Stockbarger method. Commercially available material triethylphosphine sulfide procured from Johnson Matthey was purified by physical vapor transport using low pressure sublimaton (about 30 mTorr). Modified Bridgman-Stockbarger technique is characterized by the smallest possible quantity of product in the melt for a short period of time. The temperature gradient was chosen to be about 10 C/cm and the ampoule was lowering rate was chosen to be 0.2-0.3 mm/h. For various growth conditions, several single crystal of triethylphosphine sulfide have been grown with sizes 10X10X15mm(exp 3). The second harmonic generation (SHG) efficiency was measured and has been found to be comparable to phase matched potassium dihydrogen phosphate crystals. Further characterization of the grown single crystals is in progress and the results will be presented at the symposium.

Curry, K.↗

Application of holographic optical techniques to bulk memory.

Current efforts to exploit the spatial redundancy and built-in imaging of holographic optical techniques to provide high information densities without critical alignment and tight mechanical tolerances are reviewed. Read-write-erase in situ operation is possible but is presently impractical because of limitations in available recording media. As these are overcome, it should prove feasible to build holographic bulk memories with mechanically replaceable hologram plates featuring very fast (less than 2 microsec) random access to large (greater than 100 million bit) data blocks and very high throughput (greater than 500 Mbit/sec). Using volume holographic storage it may eventually be possible to realize random-access mass memories which require no mechanical motion and yet provide very high capacity.

Anderson, L. K.↗

Bulk processing techniques for very large areas - Landsat classification of California

In 1977, California Law AB452 was passed to provide a mandate for the California Department of Forestry (CDF) to design and implement an information system to assess the forest land base for multiple uses and values. In connection with this mandate, a land-cover map of the entire state, emphasizing forest types, was produced. In producing this map, the latest techniques in digital image mosaicking were combined with the highspeed processing capability available on the ILLIAC IV parallel processor and other computer systems at the Ames Research Center (ARC). An operational and very responsive analysis method was developed at ARC that permitted on-time response to weekly workshops conducted with CDF field personnel to identify all 1,200 spectral classes and to produce final products. Over 100,000,000 acres were classified in the period between December 1, 1978, and April 15, 1979. All analyses were conducted using existing software.

Newland, W.↗

Operational Assimilation of GOES Data into a Mesoscale Model

A technique has been developed for assimilating GOES-derived skin temperature tendencies and insolation into the surface energy budget equation of a mesoscale model so that the simulated rate of temperature change closely agrees with the satellite observations. A critical assumption of the technique is that the availability of moisture (either from the soil or vegetation) is the least known term in the model's surface energy budget. Therefore, the simulated latent heat flux, which is a function of surface moisture availability, is adjusted based upon differences between the modeled and satellite- observed skin temperature tendencies. An advantage of this technique is that satellite temperature tendencies are assimilated in an energetically consistent manner that avoids energy imbalances and surface stability problems that arise from direct assimilation of surface shelter temperatures. The fact that the rate of change of the satellite skin temperature is used rather than the absolute temperature means that sensor calibration is not as critical. The technique has been employed on a semi-operational basis at the Global Hydrology and Climate Center (GHCC) within the Penn State/National Center for Atmospheric Research (PSU/NCAR) Mesoscale Model (MM5) since 1 November 1998. We performed the assimilation on a model grid centered over the Southeastern US. In addition, a control run without assimilation was performed to provide insight into the performance of the assimilation technique. Bulk verification statistics (BIAS and RMSE) of surface air temperature and relative humidity of more than 250 case days has been performed to date. Results show that assimilation of the satellite data results reduces both the bias and RMSE for simulations of surface air temperature and relative humidity. We are working with forecasters at the National Weather Service Forecast Office located in Birmingham, AL to evaluate the impact of the assimilation on precipitation forecasts. In addition, work is currently underway to determine the ability of both the assimilation technique and Early Eta to sense the significant changes that occur in both leaf expansion and soil moisture conditions during the Spring-Summer of 1999. This will be accomplished via examination of the simulated surface energy budgets from both modeling systems.

Lapenta, William↗

Non-destructive trace element microanalysis of as-received cometary nucleus samples using synchrotron x ray fluorescence

The Synchrotron X ray Fluorescence (SXRF) microprobe at the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, will be an excellent instrument for non-destructive trace element analyses of cometary nucleus samples. Trace element analyses of as-received cometary nucleus material will also be possible with this technique. Bulk analysis of relatively volatile elements will be important in establishing comet formation conditions. However, as demonstrated for meteorites, microanalyses of individual phases in their petrographic context are crucial in defining the histories of particular components in unequilibrated specimens. Perhaps most informative in comparing cometary material with meteorites will be the halogens and trace metals. In-situ, high spatial resolution microanalyses will be essential in establishing host phases for these elements and identifying terrestrial (collection/processing) overprints. The present SXRF microprobe is a simple, yet powerful, instrument in which specimens are excited with filtered, continuum synchrotron radiation from a bending magnet on a 2.5 GeV electron storage ring. A refrigerated cell will be constructed to permit analyses at low temperatures. The cell will consist essentially of an air tight housing with a cold stage. Kapton windows will be used to allow the incident synchrotron beam to enter the cell and fluorescent x rays to exit it. The cell will be either under vacuum or continuous purge by ultrapure helium during analyses. Several other improvements of the NSLS microprobe will be made prior to the cometary nucleus sample return mission that will greatly enhance the sensitivity of the technique.

Sutton, S. R.↗

Spatially Resolved, In Situ Carbon Isotope Analysis of Archean Organic Matter

Spatiotemporal variability in the carbon isotope composition of sedimentary organic matter (OM) preserves information about the evolution of the biosphere and of the exogenic carbon cycle as a whole. Primary compositions, and imprints of the post-depositional processes that obscure them, exist at the scale of individual sedimentary grains (mm to micron). Secondary ion mass spectrometry (SIMS) (1) enables analysis at these scales and in petrographic context, (2) permits morphological and compositional characterization of the analyte and associated minerals prior to isotopic analysis, and (3) reveals patterns of variability homogenized by bulk techniques. Here we present new methods for in situ organic carbon isotope analysis with sub-permil precision and spatial resolution to 1 micron using SIMS, as well as new data acquired from a suite of Archean rocks. Three analytical protocols were developed for the CAMECA ims1280 at WiscSIMS to analyze domains of varying size and carbon concentration. Average reproducibility (at 2SD) using a 6 micron spot size with two Faraday cup detectors was 0.4 %, and 0.8 % for analyses using 1 micron and 3 micron spot sizes with a Faraday cup (for C-12) and an electron multiplier (for C-13). Eight coals, two ambers, a shungite, and a graphite were evaluated for micron-scale isotopic heterogeneity, and LCNN anthracite (delta C-13 = -23.56 +/- 0.1 %, 2SD) was chosen as the working standard. Correlation between instrumental bias and H/C was observed and calibrated for each analytical session using organic materials with H/C between 0.1 and 1.5 (atomic), allowing a correction based upon a C-13H/C-13 measurement included in every analysis. Matrix effects of variable C/SiO2 were evaluated by measuring mm to sub-micron graphite domains in quartzite from Bogala mine, Sri Lanka. Apparent instrumental bias and C-12 count rate are correlated in this case, but this may be related to a crystal orientation effect in graphite. Analyses of amorphous Archean OM suggest that instrumental bias is consistent for 12C count rates as low as 10% relative to anthracite. Samples from the ABDP-9 (n=3; Mount McRae Shale, approximately 2.5 Ga), RHDH2a (n=2; Carrawine Dolomite and Jeerinah Fm, approximately 2.6 Ga), WRL1 (n=3; Wittenoom Fm, Marra Mamba Iron Formation, and Jeerinah Fm, approximately 2.6 Ga), and SV1 (n=1; Tumbiana Fm, approximately 2.7 Ga) drill cores, each previously analyzed for bulk organic carbon isotope composition, yielded 100 new, in situ data from Neoarchean sedimentary OM. In these samples, delta C-13 varies between -53.1 and -28.3 % and offsets between in situ and bulk compositions range from -8.3 to 18.8%. In some cases, isotopic composition and mode of occurrence (e.g. morphology and mineral associations) are statistically correlated, enabling the identification of distinct reservoirs of OM. Our results support previous evidence for gradients of oxidation with depth in Neoarchean environments driven by photosynthesis and methane metabolism. The relevance of these findings to questions of bio- and syngenicity as well as the alteration history of previously reported Archean OM will be discussed.

Williford, Kenneth H.↗

Measurement techniques for supersonic combustion testing

Measurement techniques used during nine years of intensive research in supersonic combustion are presented. The tests employed a number of combustor and injector configurations, which were directly connected to a Mach 3.2 supersonic nozzle, and both gaseous hydrogen and storable liquid fuels. Nominal plenum conditions for the arc-heated air were 3000 to 4500 R and 30 atm. Measurements included wall surface pressures, wall temperatures, heat flux, skin friction, instream cone-static and pitot pressures, and gas samples. Measurement and analysis techniques have been developed for determining total enthalpy of an airstream containing NO concentrations in excess of equilibrium using the two-throat technique, bulk combustion efficiency using steam calorimetry, radial gradients of fluid properties in the combustor exit plane using a stream tube method, and wall shear from measurements of heat transfer in a reacting supersonic flow using Reynolds analogy.

Orth, R. C.↗

Integrated optical circuits for numerical computation

The development of integrated optical circuits (IOC) for numerical-computation applications is reviewed, with a focus on the use of systolic architectures. The basic architecture criteria for optical processors are shown to be the same as those proposed by Kung (1982) for VLSI design, and the advantages of IOCs over bulk techniques are indicated. The operation and fabrication of electrooptic grating structures are outlined, and the application of IOCs of this type to an existing 32-bit, 32-Mbit/sec digital correlator, a proposed matrix multiplier, and a proposed pipeline processor for polynomial evaluation is discussed. The problems arising from the inherent nonlinearity of electrooptic gratings are considered. Diagrams and drawings of the application concepts are provided.

Verber, C. M.↗

3D-Laser-Scanning Technique Applied to Bulk Density Measurements of Apollo Lunar Samples

In order to better interpret gravimetric data from orbiters such as GRAIL and LRO to understand the subsurface composition and structure of the lunar crust, it is import to have a reliable database of the density and porosity of lunar materials. To this end, we have been surveying these physical properties in both lunar meteorites and Apollo lunar samples. To measure porosity, both grain density and bulk density are required. For bulk density, our group has historically utilized sub-mm bead immersion techniques extensively, though several factors have made this technique problematic for our work with Apollo samples. Samples allocated for measurement are often smaller than optimal for the technique, leading to large error bars. Also, for some samples we were required to use pure alumina beads instead of our usual glass beads. The alumina beads were subject to undesirable static effects, producing unreliable results. Other investigators have tested the use of 3d laser scanners on meteorites for measuring bulk volumes. Early work, though promising, was plagued with difficulties including poor response on dark or reflective surfaces, difficulty reproducing sharp edges, and large processing time for producing shape models. Due to progress in technology, however, laser scanners have improved considerably in recent years. We tested this technique on 27 lunar samples in the Apollo collection using a scanner at NASA Johnson Space Center. We found it to be reliable and more precise than beads, with the added benefit that it involves no direct contact with the sample, enabling the study of particularly friable samples for which bead immersion is not possible

Macke, R. J.↗

A Groundmass Composition for EET 79001A Using a Novel Microprobe Technique for Estimating Bulk Compositions. Lithology A as an Impact Melt?

Petrologic investigation of the shergottites has been hampered by the fact that most of these meteorites are partial cumulates. Two lines of inquiry have been used to evaluate the compositions of parental liquids: (i) perform melting experiments at different pressures and temperatures until the compositions of cumulate crystal cores are reproduced [e.g., 1]; and (ii) use point-counting techniques to reconstruct the compositions of intercumulus liquids [e.g., 2]. The second of these methods is hampered by the approximate nature of the technique. In effect, element maps are used to construct mineral modes; and average mineral compositions are then converted into bulk compositions. This method works well when the mineral phases are homogeneous [3]. However, when minerals are zoned, with narrow rims contributing disproportionately to the mineral volume, this method becomes problematic. Decisions need to be made about the average composition of the various zones within crystals. And, further, the proportions of those zones also need to be defined. We have developed a new microprobe technique to see whether the point-count method of determining intercumulus liquid composition is realistic. In our technique, the approximating decisions of earlier methods are unnecessary because each pixel of our x-ray maps is turned into a complete eleven-element quantitative analysis. The success or failure of our technique can then be determined by experimentation. As discussed earlier, experiments on our point-count composition can then be used to see whether experimental liquidus phases successfully reproduce natural mineral compositions. Regardless of our ultimate outcome in retrieving shergottite parent liquids, we believe our pixel-bypixel analysis technique represents a giant step forward in documenting thin-section modes and compositions. For a third time, we have analyzed the groundmass composition of EET 79001, 68 [Eg]. The first estimate of Eg was made by [4] and later modified by [5], to take phase diagram considerations into account. The Eg composition of [4] was too olivine normative to be the true Eg composition, because the ,68 groundmass contains no forsteritic olivine. A later mapping by [2] basically reconfirmed the modifications of [5]. However, even the modified composition of [5] has olivine on the liquidus for ~50 C before low-Ca pyroxene appears [6].

Jones, John H.↗

Techniques for measuring bulk gas-motions from satellites

There is a growing appreciation for the dynamic nature of the upper atmosphere. This paper is concerned principally with discussing the methods for making in-situ measurements of the ambient gas velocities from satellites. Both neutral and ion instrumentation is discussed, but most attention is paid to the ion sensors on Atmosphere-Explorer-C, which are now providing the first detailed three-dimensional gas-velocity measurements from a satellite. While some data are presented, emphasis is placed on experimental difficulties and possible ways of alleviating these problems. It seems reasonable to expect that both neutral and ion gas velocities will be measured to an accuracy of the order of 20 m/s in future satellites, provided that a star tracker is available for the determination of vehicle attitude. The possible exception to this is the ram component of the neutral-gas velocity vector, for which no proven instrumentation yet exists.

Hanson, W. B.↗

The Feasibility of Bulk Crystallization as an Industrial Purification and Production Technique for Proteins

Bulk crystallization in stirred vessels is used industrially for the recovery and purification of many inorganic and organic materials. Although much has been written on the crystallization of proteins for X-ray diffraction analysis, very little has been reported on the application of bulk crystallization in stirred vessels. In this study, a 1-liter, seeded, stirred, batch crystallizer was used with ovalbumin as a model protein to test the feasibility of this crystallization method as a recovery and purification process for proteins. Results were obtained for ovalbumin solubility, nucleation thresholds, crystal breakage and crystal growth kinetics in bulk solution under a range of operating conditions of pH and ammonium sulphate concentration (Judge et al., 1996). Experiments were also performed to determine the degree of purification that can be achieved by the crystallization of ovalbumin from a mixture of proteins. The effect of the presence of these proteins upon the ovalbumin crystal growth kinetics was also investigated (Judge et al., 1995). All of these aspects are essential for the design of bulk crystallization processes which have not previously been reported for proteins. Results from a second study that investigated the effect of structurally different proteins on the solubility, crystal growth rates and crystal purity of chicken egg white lysozyme are also presented (Judge et al., 1997). In this case face growth rates were measured using lysozyme purified by liquid chromatography and the effect of the addition of specific protein impurities were observed on the (110) and (101) crystal faces. In these two studies the results are presented to show the feasibility and purifying ability of crystallization as a production process for proteins.

Judge, Russell A.↗

Dynamic measurement of bulk modulus

Technique based on measuring phase difference between microwave reference and test signals and has been used to determine change in bulk modulus of solid-fuel rocket propellants should be useful in studying other dielectric materials.

Dowler, W. L.↗

A chemical/microwave technique for the measurement of bulk minority carrier lifetime in silicon wafers

A chemical/microwave technique for the measurement of bulk minority carrier lifetime in silicon wafers is described. This method consists of a wet chemical treatment (surface cleaning, oxidation in solution, and measurement in HF solution) to passivate the silicon surfaces, a laser diode array for carrier excitation, and a microwave bridge measuring system which is more sensitive than the microwave systems used previously for lifetime measurement. Representative experimental data are presented to demonstrate this technique. The result reveals that this method is useful for the determination of bulk lifetime of commercial silicon wafers.

Luke, Keung L.↗

Prompt Gamma Activation Analysis (PGAA): Technique of choice for nondestructive bulk analysis of returned comet samples

Prompt gamma activation analysis (PGAA) is a well-developed analytical technique. The technique involves irradiation of samples in an external neutron beam from a nuclear reactor, with simultaneous counting of gamma rays produced in the sample by neutron capture. Capture of neutrons leads to excited nuclei which decay immediately with the emission of energetic gamma rays to the ground state. PGAA has several advantages over other techniques for the analysis of cometary materials: (1) It is nondestructive; (2) It can be used to determine abundances of a wide variety of elements, including most major and minor elements (Na, Mg, Al, Si, P, K, Ca, Ti, Cr, Mn, Fe, Co, Ni), volatiles (H, C, N, F, Cl, S), and some trace elements (those with high neutron capture cross sections, including B, Cd, Nd, Sm, and Gd); and (3) It is a true bulk analysis technique. Recent developments should improve the technique's sensitivity and accuracy considerably.

Lindstrom, David J.↗

Ionized dopant concentrations at the heavily doped surface of a silicon solar cell

Data are combined with concentrations obtained by a bulk measurement method using successive layer removal with measurements of Hall effect and resistivity. From the MOS (metal-oxide-semiconductor) measurements it is found that the ionized dopant concentration N has the value (1.4 + or - 0.1) x 10 to the 20th power/cu cm at distances between 100 and 220 nm from the n(+) surface. The bulk measurement technique yields average values of N over layers whose thickness is 2000 nm. Results show that, at the higher concentrations encountered at the n(+) surface, the MOS C-V technique, when combined with a bulk measurement method, can be used to evaluate the effects of materials preparation methodologies on the surface and near surface concentrations of silicon cells.

Weinberg, I.↗