100 kHz High-Spectral-Resolution NO-PLIF Measurements for Compressible Flows
In the present work, we use a burst-mode laser and optical parametric oscillator system to perform high-spectral resolution NO-PLIF measurements of an underexpanded jet at a repetition-rate of 100 kHz, with the motivation of multi-parameter measurements of temperature, pressure, and velocity. The laser frequency of the 1064 nm seed laser for the burst-mode laser was scanned during the burst to cover two neighboring absorption line pairs near 226 nm. The peak PLIF signal intensity varies along the axial (z) direction of the underexpanded jet as the laser frequency is scanned, which we attribute to the collisional shift induced by the flow and only revealed due to the narrow linewidth of the laser. A pseudo-Voight fit is applied to the LIF excitation spectra on a pixel-by-pixel basis to measure the spectral position of the peak intensity for the two transition pairs and their amplitude. The spectral position of the peak intensity is used to derive a frequency shift, which is separated into its collisional and Doppler components using the axisymmetric nature of the flow field. The amplitude of the measured peaks is used for two-line rotational thermometry. Challenges for quantitative measurements using such an approach are discussed, including measuring the spatial variations in the energy distribution of the laser sheet at a 100 kHz repetition rate and uncertainty/variability in the step size during the fast frequency scan.
100 kHz High-Spectral-Resolution NO-PLIF Measurements for Compressible Flows
In the present work, we use a burst-mode laser and optical parametric oscillator system to perform high-spectral resolution NO-PLIF measurements of an underexpanded jet at a repetition-rate of 100 kHz, with the motivation of multi-parameter measurements of temperature, pressure, and velocity. The laser frequency of the 1064 nm seed laser for the burst-mode laser was scanned during the burst to cover two neighboring absorption line pairs near 226 nm. The peak PLIF signal intensity varies along the axial (z) direction of the underexpanded jet as the laser frequency is scanned, which we attribute to the collisional shift induced by the flow and only revealed due to the narrow linewidth of the laser. A pseudo-Voight fit is applied to the LIF excitation spectra on a pixel-by-pixel basis to measure the spectral position of the peak intensity for the two transition pairs and their amplitude. The spectral position of the peak intensity is used to derive a frequency shift, which is separated into its collisional and Doppler components using the axisymmetric nature of the flow field. The amplitude of the measured peaks is used for two-line rotational thermometry. Challenges for quantitative measurements using such an approach are discussed, including measuring the spatial variations in the energy distribution of the laser sheet at a 100 kHz repetition rate and uncertainty/variability in the step size during the fast frequency scan.
A Compact, Solid-State UV (266 nm) Laser System Capable of Burst-Mode Operation for Laser Ablation Desorption Processing
Compared to wet chemistry and pyrolysis techniques, in situ laser-based methods of chemical analysis provide an ideal way to characterize precious planetary materials without requiring extensive sample processing. In particular, laser desorption and ablation techniques allow for rapid, reproducible and robust data acquisition over a wide mass range, plus: Quantitative, spatially-resolved measurements of elemental and molecular (organic and inorganic) abundances; Low analytical blanks and limits-of-detection ( ng g-1); and, the destruction of minimal quantities of sample ( g) compared to traditional solution and/or pyrolysis analyses (mg).
Time-Resolved OH-PLIF Assessment of Deflagrations Levels in a CH4-O2 Rotating Detonation Rocket Combustor
The parasitic loss incurred by deflagrative pre-burning is considered to be one of the key challenges to the effective implementation of rotating detonation engine (RDE) systems. Thus far, there have been relatively limited high fidelity, spatio-temporally resolved measurements of the pre-burning process as a function of the reactant conditions and composition within an RDE. In this work, simultaneous high-repetition-rate broadband OH* chemiluminescence and OH planar laser-induced fluorescence (PLIF) imaging are employed to investigate deflagrative burning dynamics in a fully optically accessible CH4-O2 RDE as compared to a H2-air systems under the same conditions. A custom-built optical parametric oscillator (OPO) is coupled with a high-repetition-rate burst-mode laser to generate the 284 nm source for the excitation of the Q1(9) transition of the OH radical. Significant deflagrative burning is observed throughout the chamber as a consequence of the oxygen-rich environment. Trailing wave systems that consume unburned reactants in the region immediately following the primary detonation wave are observed. The formation of a product gas recirculation zone that entrains and combusts incoming reactants is observed, and quantitative analysis is performed to gain valuable insight into deflagration characteristics. At an oxidizer mass flux of Gox ≈ 350kg/m2/s, it is found that the levels of pre-wave burning in CH4-O2 are a factor of ∼2-3 times higher than in H2-air in the region directly ahead of the detonation wave at a global equivalence ratio Φ ≈ 1.0. This study highlights the key roles of ignition delay and turbulent mixing of the combustion product and reactant fields on the levels of pre-burning and establishes a methodology for further investigation, such as for the effects of various RDE inlet configurations.
100-kHz Rate Rayleigh Imaging for Combustion and Flow Diagnostics
Two-dimensional (2D) Rayleigh scattering (RS) imaging at an ultrahigh repetition rate of 100 kHz is demonstrated in non-reacting and reacting flows employing a high-energy burst-mode laser system. Image sequences of flow mixture fraction were directly derived from high-speed RS images. Additionally, a 2D instantaneous flow velocity field at 100 kHz was obtained through optical-flow-based analysis of the RS images. The technique was also applied to study turbulent flames having a near-constant Rayleigh cross section. The demonstrated high-speed RS technique in conjunction with optical-flow-based analysis provides non-intrusive, simultaneous measurements of the flow mixing and velocity field, extending the measurement capability of the RS technique to high-speed non-reacting and reacting flows.
Advanced Diagnostics for Megahertz Imaging of Mixing, Fuel Spray, and Combustion Processes for Rotating Detonation Combustors
Recent advancements in megahertz rate, high-power, burst-mode laser technology are leveraged to perform and explore imaging measurements that spatially and temporally resolve the mixing, combustion, and detonation flow field in two laboratory-scale rotating detonation combustors (RDCs). In a non-premixed annular RDC, multiple imaging diagnostics are explored to investigate gaseous and liquid injector behavior, the detonation wave structure, and the propellant refill. In one instance, OH planar laser-induced fluorescence (OH-PLIF) imaging is performed up to a 2 MHz repetition rate to track the combustion products and reaction zone locations. In the same annular RDC, a single liquid fuel jet is injected, and laser-based 355-nm imaging of the fuel spray is performed up to a 1 MHz repetition rate. For this configuration, the annular RDC is used as a detonation driver to impose periodic detonation waves to interact with the fuel spray. Moreover, in this annular RDC, a range of tracer-based laser imaging measurements are explored to time-resolve the unsteady oxidizer air recovery and refill process. In a non-premixed linear RDC, planar imaging measurements of the fuel mixing are performed up to a 200 kHz repetition rate using PLIF of a tracer in the fuel supply. The fuel mixing imaging helps explain the origin of the observed pre and post wave burning, detonation structure, and enables quantifying injector recovery timescales. This paper will provide a high-level broad survey of diagnostics applied in these RDCs, lessons learned, and interesting observations.
Advanced Diagnostics For Megahertz Imaging Of Mixing, Fuel Spray, And Combustion Processes For Rotating Detonation Combustors
Recent advancements in megahertz rate, high-power, burst-mode laser technology are leveraged to perform and explore imaging measurements that spatially and temporally resolve the mixing, combustion, and detonation flow field in two laboratory-scale rotating detonation combustors (RDCs). In a non-premixed annular RDC, multiple imaging diagnostics are explored to investigate gaseous and liquid injector behavior, the detonation wave structure, and the propellant refill. In one instance, OH planar laser-induced fluorescence (OH-PLIF) imaging is performed up to a 2 MHz repetition rate to track the combustion products and reaction zone locations. In the same annular RDC, a single liquid fuel jet is injected, and laser-based 355-nm imaging of the fuel spray is performed up to a 1 MHz repetition rate. For this configuration, the annular RDC is used as a detonation driver to impose periodic detonation waves to interact with the fuel spray. Moreover, in this annular RDC, a range of tracer-based laser imaging measurements are explored to time-resolve the unsteady oxidizer air recovery and refill process. In a non-premixed linear RDC, planar imaging measurements of the fuel mixing are performed up to a 200 kHz repetition rate using PLIF of a tracer in the fuel supply. The fuel mixing imaging helps explain the origin of the observed pre and post wave burning, detonation structure, and enables quantifying injector recovery timescales. This paper will provide a high-level broad survey of diagnostics applied in these RDCs, lessons learned, and interesting observations.
Advancements in Burst-Mode Filtered Rayleigh Scattering for High-Speed Gas-Phase Multi-Parameter Measurements
Filtered Rayleigh scattering (FRS) can be used for velocity, density, temperature, and/or pressure measurements over a wide range of non-reacting flow conditions as well as more limited reacting flow conditions. However, the application of FRS to gas-phase measurements in large-scale test facilities can be limited due to low signal levels, strong background interferences, or the requirement for multiple cameras and/or molecular filters to spectrally resolve the signal. This work focuses on the spectral characteristics and wavelength-agility of burst-mode lasers for use in FRS systems. These advancements could improve measurement capability and data quality in applications with high levels of stray background scattering as well as where increased temporal resolution is desirable, such as high-speed flows.
Demonstration of Frequency-Scanning Burst-mode Filtered Rayleigh Scattering for Multi-Parameter Gas-Phase Measurements
Filtered Rayleigh scattering (FRS) is a diagnostic technique used for measurements of macroscopic properties of a gas. The FRS signal is passed through a narrow bandwidth molecular filter, commonly gaseous iodine, to measure the broadening and Doppler-shift of the scattering light from the molecules of the gas flow. However, in single-frequency, intensity-based approaches, the effects of pressure, temperature, and velocity can be difficult to deconvolve. To overcome this challenge, frequency-scanning FRS has been used to quasi-spectrally resolve the signal. In this work, a frequency-scanned, burst-mode laser was used to perform scanning FRS in an underexpanded jet to measure temperature, pressure, and radial velocity at measurement rates up to 1 kHz which is ~100,000 times faster than prior implementations of scanning FRS.
Characterization of Reactant Refill and Detonation Wave Dynamics in a GOx/Natural-gas RDRE Using Simultaneous High Repetition-Rate OH-PLIF and Chemiluminescence
The potential application of rotating detonation engines (RDEs) in rocket combustors hinges on a fundamental understanding of detonation wave structure and injector characteristics with fuel and oxidizer compositions relevant in rocket systems. Simultaneous 300 kHz-rate broadband OH* chemiluminescence and OH-PLIF imaging is employed in a fully optically accessible Natural Gas-GOx rotating detonation rocket engine (RDRE) to visualize reactant refill dynamics and detonation wave structure. A custom-built KTP-type optical parametric oscillator (OPO) is coupled with a nanosecond high-repetition-rate burst-mode laser to output284 nm light and target excitation of the Q1(9) transition in the OH radical. Significant deflagrative burning is observed throughout the chamber as a consequence of the oxygen-rich environment. Trailing Azimuthal Reflected Shock Combustion (ARSC) system, similar to those in a H2-air RDE are observed, burning unburned reactants in the region immediately following the primary detonation wave. Contact burning, as indicated in this study, does not seem to be a primary loss mechanism. The simultaneous measurement of OH and OH* show that axial locations exist in the refill process where OH radicals are present, and produced due to shear layer induced deflagration, however, these zones do not produce excited state OH*. While a deeper understanding of the underlying physics in RDRE systems requires further investigation, this work highlights a first-of-its-kind visualization of the turbulent combustion product field and reactant refill characteristics in this highly unsteady environment.
Visualization of Freestream Vortices in the NASA Langley 4-Foot Supersonic Unitary Plan Wind Tunnel
Streamwise vortices present in the freestream of the NASA Langley 4-Foot Supersonic Unitary Plan Wind Tunnel have been observed experimentally for the first time. A high-energy, burst-mode laser system was used to conduct time-resolved planar laser Mie scattering in the freestream of this facility. The freestream of the facility was observed over Mach numbers ranging from 2.4 to 4.6 and (unit) Reynolds number between 3.3 × 10 6 to 14.8 × 10 6 1/m. Apparent vortical structures were observed in the tunnel freestream at Mach numbers ≤ 3 with little difference observed for varying Reynolds number. With further-increasing Mach number, protrusive and oscillatory vertical ‘sprite’ structures were observed emanating from the tunnel floor boundary layer. Neither of these structural phenomena have been observed before experimentally in the facility and act to confirm and inform predictions made in computational fluid dynamic simulations of the facility.
Visualization of Freestream Vortices in the NASA Langley 4-Foot Supersonic Unitary Plan Wind Tunnel
Streamwise vortices present in the freestream of the NASA Langley 4-Foot Supersonic Unitary Plan Wind Tunnel have been observed experimentally for the first time. A high-energy, burst-mode laser system was used to conduct time-resolved planar laser Mie scattering in the freestream of this facility. The freestream of the facility was observed over Mach numbers ranging from 2.4 to 4.6 and (unit) Reynolds number between 3.3 × 10 6 to 14.8 × 10 6 1/m. Apparent vortical structures were observed in the tunnel freestream at Mach numbers ≤ 3 with little difference observed for varying Reynolds number. With further-increasing Mach number, protrusive and oscillatory vertical ‘sprite’ structures were observed emanating from the tunnel floor boundary layer. Neither of these structural phenomena have been observed before experimentally in the facility and act to confirm and inform predictions made in computational fluid dynamic simulations of the facility.
Burst-Mode Frequency-Scanning Planar Laser-Induced Fluorescence for Multi-Parameter Measurements
Explore the source record for details and available documents.
10-kHz PLIF Thermometry for a Turbulent Jet Flame using Single Burst-mode OPO
Two-color Planar laser-induced fluorescence (TC-PLIF) thermometry techniques that employ two laser systems and two cameras face challenges when implemented in practical combustion facilities because of experimental complexity and multiple laser and camera requirements, particularly for high-speed TC-PLIF. To circumvent those problems, we developed a fast, dual-wavelength switching, burst-mode OPO technology to significantly reduce the experimental complexity of high-speed TC-PLIF thermometry and simplify its implementation in harsh combustion and flow test facilities. A fast, dual-wavelength switched seed laser enabled a high-energy, high-repetition-rate burst-mode laser to generate two 10-kHz pulse trains at wavelengths of ~354.8 nm. The injection-seeded OPO efficiently converts the burst-mode laser output to285.62 nm and 285.67 nm to excite the Q2(12) and P1(8) OH transitions. PLIF images were collected from each of the two excitation transitions with a single camera and an UV intensifier, and intensity ratios from the images were used to determine local temperatures. Ten kHz hydroxyl radical (OH) TC-PLIF for premixedCH4/Air/H2 jet flame was demonstrated.
10-kHz PLIF Thermometry for Turbulent Jet Flame using Single Burst-mode OPO
Two-color Planar Laser-Induced Fluorescence (TC-PLIF) thermometry techniques that employ two laser systems and two cameras face challenges when implemented in practical combustion facilities because of experimental complexity and multiple laser and camera requirements, particularly for high-speed TC-PLIF. To circumvent those problems, we developed a fast, dual-wavelength switching, burst-mode OPO technology to significantly reduce the experimental complexity of high-speed TC-PLIF thermometry and simplify its implementation in harsh combustion and flow test facilities. A fast, dual-wavelength switched seed laser enabled a high-energy, high-repetition-rate burst-mode laser to generate two 10-kHz pulse trains at wavelengths of ~354.8 nm. The injection-seeded OPO efficiently converts the burst-mode laser output to 285.62 nm and 285.67 nm to excite the Q2(12) andP1(8) OH transitions. PLIF images were collected from each of the two excitation transitions with a single camera and an UV intensifier, and intensity ratios from the images were used to determine local temperatures. Ten kHz hydroxyl radical (OH) TC-PLIF for premixedCH4/Air/H2 jet flame was demonstrated.
Investigation of Liquid Fuel Injection Processes in a Rotating Detonation Combustor using Megahertz Planar Laser-Induced Fluorescence Imaging
Direct imaging of liquid fuel injection is performed within an optically accessible rotating detonation combustor (RDC) using planar laser-induced fluorescence (PLIF) to spatio-temporally resolve the highly dynamic spray characteristics at rates up to 1 MHz. The RDC is operated on air and hydrogen to sustain a stable, cyclically propagating detonation wave with cycle periods of up to ∼250 μs. One of the hydrogen fuel injection sites is replaced with a liquid jet to introduce a diesel spray as a fuel surrogate to enable tracer-free fluorescence excitation using the 355 nm third-harmonic output of a burst-mode Nd:YAG laser. The time-resolved PLIF measurements reveal the evolution of the highly unsteady spray, including the dwell period after the arrival of the detonation wave, the jet recovery, breakup and entrainment into the supersonic crossflow of air, propagation into the detonation chamber, and interaction with the detonation wave. Following passage of the detonation wave, the spray characteristics reveal significant changes in the momentum flux ratio between the liquid and air streams, altering the jet trajectory and temporarily halting fuel delivery to the detonation channel. This temporary cessation of fuel spray injection into the combustor is quantified, along with the fill rate as a function of time. As the injection system recovers, the fuel spray eventually returns to a quasi-steady position prior to the arrival of the detonation wave, allowing qualitative comparisons with theoretical jet trajectories for a range of air mass-flux conditions. These data, enabled by ultra-high-speed PLIF imaging, represent some of the first detailed measurements for characterizing and quantifying the interactions of liquid jets and detonations in an operating RDC.
Investigation of Liquid Fuel Refill Dynamics in a Rotating Detonation Combustor using Megahertz Planar Laser-Induced Fluorescence
Direct imaging of liquid fuel injection is performed within an optically accessible rotating detonation combustor (RDC) using planar laser-induced fluorescence (PLIF) to spatio-temporally resolve the highly dynamic spray characteristics at rates up to 1 MHz. The RDC is operated on air and hydrogen to sustain a stable, cyclically propagating detonation wave with cycle periods of up to ∼250 μs. One of the hydrogen fuel injection sites is replaced with a liquid jet to introduce a diesel spray as a fuel surrogate to enable tracer-free fluorescence excitation using the 355 nm third-harmonic output of a burst-mode Nd:YAG laser. The time-resolved PLIF measurements reveal the evolution of the highly unsteady spray, including the dwell period after the arrival of the detonation wave, the jet recovery, breakup and entrainment into the supersonic crossflow of air, propagation into the detonation chamber, and interaction with the detonation wave. Following passage of the detonation wave, the spray characteristics reveal significant changes in the momentum flux ratio between the liquid and air streams, altering the jet trajectory and temporarily halting fuel delivery to the detonation channel. This temporary cessation of fuel spray injection into the combustor is quantified, along with the fill rate as a function of time. As the injection system recovers, the fuel spray eventually returns to a quasi-steady position prior to the arrival of the detonation wave, allowing qualitative comparisons with theoretical jet trajectories for a range of air mass-flux conditions. These data, enabled by ultra-high-speed PLIF imaging, represent some of the first detailed measurements for characterizing and quantifying the interactions of liquid jets and detonations in an operating RDC.