SEARCH · Search NASA
Results for “cUAS Testing”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Melter Testing for Technetium Removal Using Goethite Precipitation
During vitrification of low activity waste (LAW) at the Hanford Tank Waste Treatment and Immobilization Plant (WTP), liquid effluents are produced in the primary off-gas treatment system that processes the exhaust gases from the LAW melters. That effluent stream, which contains captured hazardous and radioactive species from the melter exhaust, is then recycled and eventually becomes part of subsequent melter feed batches. Other constituents, such as sulfur and halides, are also recycled in this process and this can impact the LAW glass loadings that are achievable. Thus, breaking the melter recycle loop could have advantages with respect to reducing LAW glass volumes. However, this recycle stream cannot currently be diverted to liquid secondary waste treatment because of the levels of several constituents in the scrub solutions, particularly technetium. Researchers at Pacific Northwest National Laboratory (PNNL) have been investigating a process whereby the technetium could be precipitated from the off-gas recycle stream in the mineral goethite ((Tc, Fe)OOH). It could then be diverted to the high level waste (HLW) stream through the WTP pretreatment facility and the decontaminated liquid stream could be sent to secondary waste treatment. As part of the test program to develop the goethite precipitation process, it is necessary to assess the impacts of including this material in the HLW melter feed and the extent to which the captured technetium is volatilized during HLW vitrification. To support such testing, sufficiently large batches of material were prepared at PNNL using rhenium as a surrogate for technetium. These materials were shipped to the Vitreous State Laboratory (VSL) of the Catholic University of America (CUA) for testing on a DuraMelter 10 (DM10) small-scale joule-heated ceramic melter system. This report describes the testing that was performed with those materials.
Enhanced LAW Glass Correlation - Phase 1
About 50 million gallons of high-level mixed waste is currently stored in underground tanks at the United States Department of Energy’s (DOE’s) Hanford site in the State of Washington. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will provide DOE’s Office of River Protection (ORP) with a means of treating this waste by vitrification for subsequent disposal. The tank waste will be separated into low- and high-activity waste fractions, which will then be vitrified respectively into Immobilized Low Activity Waste (ILAW) and Immobilized High Level Waste (IHLW) products. The ILAW product will be disposed in an engineered facility on the Hanford site while the IHLW product is designed for acceptance into a national deep geological disposal facility for high-level nuclear waste. The ILAW and IHLW products must meet a variety of requirements with respect to protection of the environment before they can be accepted for disposal. Acceptable glass formulations for vitrification of Hanford low activity waste (LAW) must meet a variety of product quality, processability, and waste loading requirements. To this end, The Vitreous State Laboratory (VSL) at The Catholic University of America (CUA) developed and tested a number of glass formulations during Part A, Part B1 and Part B2 of the WTP development program. The testing resulted in the selection of target glass compositions for the processing of eight of the Phase I LAW tanks. The selected glass compositions were tested at the crucible scale to confirm their compliance with ILAW performance requirements. Duramelter 100 (DM100) and LAW Pilot Melter tests were then conducted to demonstrate the viability of these glass compositions for LAW vitrification at high processing rates.
FY24 Development of Improved Grout Waste Forms for Alternative Low Activity Waste Treatment
Since the WTP Low Activity Waste (LAW) Vitrification Facility was not designed to process the entire inventory of Hanford LAW, up to half of the retrieved Hanford LAW will require supplemental immobilization. Immobilizing LAW in a cementitious waste form known as Cast Stone has been investigated as a possible candidate supplemental immobilization technology. In FY21, Washington River Protection Solutions, LLC (WRPS) tasked Atkins and the Vitreous State Laboratory (VSL) of The Catholic University of America (CUA) to perform testing to evaluate methods for reducing the release of COCs, particularly nitrate, 99Tc, and 129I, from cementitious waste forms made from aqueous LAW derived from Hanford Tank Waste. FY22 work built on the FY21 results and further developed formulations while targeting higher waste loadings. The objective of this work was to perform laboratory-scale testing to further refine the most promising formulation(s) that were identified in the FY23 work. The goal of the refinement was to further reduce the release rates for 99Tc, Cr, 129I, and nitrate while maintaining workability of the fresh grout, and to increase waste loading.
Drone Fleet Summary: NNLEMS UxS Rolodex entry for Sandia
Sandia’s UAS Aviation Operations Unit (UAOU) was established in 2019 to be the single entity at Sandia conducting UAS Ops in support the labs Uncrewed Aircraft Systems (UAS) activities. The UAOU currently consists of >330 FAA Registered UAS with a large variety of primarily Class 1&2 UAS: fixed wing (>90), multi-rotor (>230), hybrids, VTOLs, jets, and balloons. Many of these are threat vehicles presented as targets to Counter-UAS (CUAS) systems as part of performance tests, with the remainder in support of other projects across Sandia often with custom payload needs. The UAOU has ~15 primary pilots and reach back to another ~45 FAA Certified Remote Pilots across Sandia. The team conducts flight and CUAS operations at many test locations, including OCONUS. Sandia was awarded the 2024 DOE Federal Aviation Safety Program Award.
CUAS T&E - Center for Security Technology Analysis Response and Testing.
Abstract not provided.
Acetonitrile Destruction and Fate of Organics in the Reverse Osmosis System at the ETF
The Hanford Site Effluent Treatment Facility (ETF) currently treats aqueous waste streams that include condensates from the 242-A evaporator, leachate from the Environmental Restoration Disposal Facility (ERDF), as well as laboratory wastes and, in the future, will treat liquid effluents from the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and Integrated Disposal Facility (IDF) leachate. Liquid effluents from the WTP will have significant concentrations of acetonitrile. Acetonitrile is formed by reaction of nitrates and sugar in the WTP low activity waste (LAW) melters and is prevalent in the submerged bed scrubber (SBS) and wet electrostatic precipitator (WESP) liquid effluents from WTP off-gas treatment. When these liquids are concentrated in the WTP Effluent Management Facility (EMF) evaporator in the direct feed low activity waste (DFLAW) flow-sheet, testing has shown that the majority of the acetonitrile partitions to the evaporator condensate. Since the evaporator condensate is directed to the ETF, this creates a potential issue with the ETF waste acceptance criteria. Consequently, there is a need to validate flow-sheet assumptions on the fate of acetonitrile and other organics within the ETF. The present plan includes the addition of a steam stripper to the ETF to remove acetonitrile. There is, therefore, also a need to determine a suitable method to destroy acetonitrile in the overhead condensate stream from the new steam stripper. Washington River Protection Solutions, LLC (WRPS) previously contracted with Atkins and the Vitreous State Laboratory (VSL) of The Catholic University of America (CUA) to perform development and testing work to evaluate potential methods for destruction of acetonitrile in WTP secondary liquid effluents. Based on the results of that work, WRPS requested that follow-on testing be conducted to further evaluate acetonitrile destruction in the steam stripper condensate using ultraviolet oxidation (UV/OX) with persulfate. WRPS also requested testing to assess the rejection rate of organics in the reverse osmosis (RO) system installed in the ETF. This report presents the results from testing to address those needs.
Vitrification Tests with Potential Technetium Capture Streams
About 50 million gallons of high-level waste is currently stored in underground tanks at The United States Department of Energy’s (DOE’s) Hanford site in the State of Washington. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will provide DOE’s Office of River Protection (ORP) with a means of treating this waste by vitrification for subsequent disposal. The tank waste will be separated into low- and high-activity waste fractions, which will then be vitrified respectively into Immobilized Low Activity Waste (ILAW) and Immobilized High Level Waste (IHLW) products. The ILAW product will be disposed in an engineered facility on the Hanford site while the IHLW product is designed for acceptance at a national deep geological disposal facility for high-level nuclear waste. The ILAW and IHLW products must meet a variety of requirements with respect to protection of the environment before they can be accepted for disposal. The Low Activity Waste (LAW) and High-Level Waste (HLW) at Hanford will be vitrified in Joule Heated Ceramic Melters (JHCMs) to produce stable products for disposal. Technetium is an important radioactive component in the Hanford tank waste and is typically one of the principal contributors to risk in performance assessments for the ILAW disposal facility. Technetium is also one of the more volatile radionuclides and the retention of technetium in the glass under the high temperature conditions prevailing during vitrification can vary over a relatively wide range depending on the feed composition, feed chemistry, and melter operating parameters. In support of the WTP Project, the Vitreous State Laboratory (VSL) at The Catholic University of America (CUA) and EnergySolutions have developed and tested glass formulations for WTP waste envelopes to provide data to meet the WTP contract requirements and to support system design activities. That work is based upon small-scale batch melts (“crucible melts”) using waste simulants. Glass compositions suitable for processing the tank waste streams for the WTP have been identified and tested for processing and product quality requirements at various scales, ranging from crucible melts of a few grams, up to the LAW Pilot Melter at processing rates in excess of 6600 kg/day (2000 kg/m 2 /day). Recent testing performed at VSL for Washington River Protection Solutions, LLC (WRPS) has investigated the baseline “single-pass” retention of technetium over the range of WTP LAW feed compositions and glass formulations as well as the development of potential modifications to the baseline that could increase the single-pass retention. For the WTP melter systems, the liquid waste streams from the primary off-gas system components are recycled back to the pretreatment facility and, ultimately, to subsequent melter feed batches. Such a recycle loop can greatly increase the overall retention of volatile constituents in the glass product over the single-pass value. Accordingly, more recent testing at VSL has been conducted on a melter system that incorporates a recycle flow sheet. The results from that work have provided important performance data for the unit operations in the primary off-gas system with respect to technetium capture and recycle, which is crucial in assessing the amount of technetium that ultimately reports to non-glass waste forms.
IHLW PCT, Spinel T1%, Electrical Conductivity, and Viscosity Model Development (Final Report)
This report is the last in a series of currently scheduled reports that presents the results from the High Level Waste (HLW) glass formulation development and testing work performed at the Vitreous State Laboratory (VSL) of the Catholic University of America (CUA) and the development of IHLW property-composition models performed jointly by Pacific Northwest National Laboratory (PNNL) and VSL for the River Protection Project-Waste Treatment and Immobilization Plant (RPP-WTP). Specifically, this report presents results of glass testing at VSL and model development at PNNL for Product Consistency Test (PCT), one-percent crystal fraction temperature (T1%), electrical conductivity (EC), and viscosity of HLW glasses. The models presented in this report may be augmented and additional validation work performed during any future immobilized HLW (IHLW) model development work. Completion of the test objectives is addressed.
Final Report: LAW Glass Testing and VHT Model Assessment, VSL-08R1410-1, Rev 0
This report presents the results from the Low Activity Waste (LAW) glass formulation development and testing performed at the Vitreous State Laboratory (VSL) of the Catholic University of America (CUA) from October 2007 to August 2008. The work focused on certain aspects of qualification of LAW glasses for disposal in the Hanford Integrated Disposal Facility (IDF). One focus area was crystallization of LAW glasses containing less than 13.5 wt% and about 13.5 to 17.0 wt% Na 2 O, and the effect of crystallization on the behavior of these glasses on the Vapor Hydration Test (VHT) and the Product Consistency Test (PCT). Another area of interest was the performance on VHT of LAW glasses containing about 21 wt% or more of alkali oxides, and the variability in the VHT alteration rates. The VHT data were reviewed and analyzed to identify potential new approaches to modeling the relationship between VHT alteration rates and glass compositions.
FY2020 Rotating Bed Reactor for Iodine Removal from WTP Melter Effluent to Support DFLAW Start-Up
In Performance Assessment (PA) of the Hanford Integrated Disposal Facility (IDF), 129 I is a significant contributor to the risk. The 2017 IDF PA accounted for 0.22% of the total 129 I inventory in Hanford tank waste as residing in the solidified liquid waste from the Effluent Treatment Facility (ETF). However, recent estimates suggest that higher percentages of the iodine processed at the Hanford Waste Treatment and Immobilization Plant (WTP) may be present in the liquid waste routed to the Liquid Effluent Retention Facility (LERF) for eventual treatment at the ETF. In addition, a recent integrated melter test performed at the Vitreous State Laboratory (VSL) at The Catholic University of America (CUA) showed the possibility that a significant fraction (>50%) of the total iodine in the melter feed could be present in the aqueous waste stream destined for the ETF. This stream represents a combination of the Effluent Management Facility (EMF) evaporator overhead condensate and the liquid waste from the WTP off-gas caustic scrubber. Higher levels of 129 I in this stream could affect the LERF and ETF Hazard Categorizations as well as the acceptability of the solidified ETF liquid secondary waste brine for disposal at the IDF. Accordingly, there is a need to investigate and develop potential methods and processes to mitigate this risk. Washington River Protection Solutions, LLC (WRPS) tasked Atkins and VSL to perform development and testing work to evaluate potential methods for removal of iodine species from the waste stream routed to the LERF. In particular, the testing investigated the use of an Atkins-SpinIonic™ Rotating Bed Reactor (RBR) system as a potential alternative to conventional column-based ion exchange or absorption processes. The present report provides results obtained from testing with an RBR system for the removal of iodine from simulants of the projected WTP waste stream that discharges to the LERF.
Secondary Waste Form Down-Selection Data Package—DuraLith
This data package developed for the DuraLith wasteform includes information available in the open literature and from data obtained from testing currently underway. DuraLith is an alkali-activated geopolymer waste form developed by the Vitreous State Laboratory at The Catholic University of America (VSL-CUA) for encapsulating liquid radioactive waste. A DuraLith waste form developed for treating Hanford secondary waste liquids is prepared by alkali-activation of a mixture of ground blast furnace slag and metakaolinite with sand used as a filler material. Based on optimization tests, solid waste loading of {approx}7.5% and {approx}14.7 % has been achieved using the Hanford secondary waste S1 and S4 simulants, respectively. The Na loading in both cases is equivalent to {approx}6 M. Some of the critical parameters for the DuraLith process include, hydrogen generation and heat evolution during activator solution preparation using the waste simulant, heat evolution during and after mixing the activator solution with the dry ingredients, and a working window of {approx}20 minutes to complete the pouring of the DuraLith mixture into molds. Results of the most recent testing indicated that the working window can be extended to {approx}30 minutes if 75 wt% of the binder components, namely, blast furnace slag and metakaolin are replaced by Class F fly ash. A preliminary DuraLith process flow sheet developed by VSL-CUA for processing Hanford secondary waste indicated that 10 to 22 waste monoliths (each 48 ft3 in volume) can be produced per day. There are no current pilot-scale or full-scale DuraLith plants under construction or in operation; therefore, the cost of DuraLith production is unknown. The results of the non-regulatory leach tests, EPA Draft 1313 and 1316, Waste Simulant S1-optimized DuraLith specimens indicated that the concentrations of RCRA metals (Ag, Cd, Cr, Hg, and Pb) in the leachates were well below the Universal Treatment Standard limits in 40 CFR 268.48. The data from the EPA draft 1315 leach test showed that LI values for COCs, namely 99Tc and I, ranged from 8.2 to 11.4 and 4.3 to 7.5, respectively. These values indicate that 99Tc meets the WAC LI requirement of 9.0 whereas, the LI values for I does not meet the WAC requirement of 11.0. Results of Toxicity Characteristic Leaching Procedure (TCLP)(EPA Method 1311) conducted on Waste Simulant S1-optimized DuraLith specimens, indicated that the concentrations of RCRA metals (Ag, As, Cd, Cr, Hg, and Pb) in the leachates were well below the Universal Treatment Standard limits in 40 CFR 268.48. The data from the ANSI/ANS 16.1 leach test showed that LI values for COC, namely Re (as a Tc surrogate), ranged from 8.06 to 10.81. The LI value for another COC, namely I, was not measured in this test. The results of the compressive strength testing of Waste Simulant S1-optimized DuraLith specimens indicated that the monoliths were physically robust with compressive strengths ranging from 115.5 MPa (16757 psi) to 156.2 MPA (22667 psi).
Counter Unmanned Aircraft System Metrics Tool
SAND2023-05387O The Counter Unmanned Aircraft System (CUAS) Metrics Tool consists of three applications: • The Data Collection Tool is designed to be used during testing and captures details that can be imported into the Figure Creator application. • The Unmanned Aircraft System (UAS) Log Converter converts different UAS logs into a standardized hierarchical data format with a timeline of geospatial data. • The Figure Creator develops relevant images for the test event. The application includes logic to ingest and correlate data from the Data Collection Tool and the UAS Log Converter to produce the chosen figures. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.
Next Generation Melter Testing for High Aluminum HLW Glasses (Final Report)
This Final Report describes the initial DuraMelter 100 (DM100) scale testing performed to support the development of next generation advanced joule-heated melters (NG AJHMs). The initial phase of testing investigated the impacts of plenum heaters and the partial drying of melter feed prior to its introduction into the melter. The tests demonstrate the overall impacts and benefits on processing characteristics such as increases in waste processing and glass production rates, and component volatility. The results also provide melting rates for sizing calculations and compatibility of feed and off-gas treatment systems. The tests were performed with a Hanford high level waste (HLW) composition previously processed on both the DM100 melter and the HLW Pilot Melter (DM1200). The simulated waste containing a high concentration of aluminum was originally specified by the Office of River Protection (ORP) for testing at VSL. This waste composition is representative of high-aluminum feeds that will be processed at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and that are expected to challenge waste loading and processing rate objectives. This works builds upon previous work performed at the Vitreous State Laboratory (VSL) of the Catholic University of America (CUA) for ORP to increase waste loadings and waste processing rates for high aluminum HLW waste streams by glass formulation optimization, bubbling, and modest increases in melt temperature. The present tests were conducted in response to the Task Plan WP-4.1.4.
Effect of Form of Chromium on Spinel Formation
A number of Hanford high level waste (HLW) streams contain sufficiently high concentrations of chromium for it to become the waste loading limiting component in the waste. Chromium has relatively low solubility in borosilicate glasses and leads to the formation of various crystal phases including spinels. The extent of crystal formation must be managed during melter processing to prevent operational issues and potential premature melter failure that can result from excessive accumulation of crystals in the melter. In previous work for the Department of Energy (DOE) Office of River Protection (ORP), high-waste loading glass formulations were developed for representative HLW streams that are high in chromium. Results from those studies suggested that there may be differences in the crystallization behavior between glasses prepared in crucible melts and those prepared in DuraMelter 100 (DM100) joule heated melter runs. Understanding the cause of those differences has the potential to lead to the development of methods to further increase waste loadings for high chromium HLW streams through control of the formation of chromium-bearing crystals. As noted previously, the potential causes include differences in the form of components in the batch, including the form of chromium, as well as redox effects. This report describes the results from work to elucidate the origins of the observed differences and to identify melter feed composition modifications to control the formation of chromium-bearing crystal phases. The work focused on determining the effects of the form of chromium and the concentrations of oxidants in feed batches on spinel crystallization. Also evaluated was the use of potential melter feed additives to influence the redox state of chromium in the melt and its effect on spinel crystallization. As described in the Test Plan for this work, the objectives were accomplished through a combination of crucible-scale tests, small-scale tests with additives to influence redox state, and melter tests. This work builds on previous work performed at the Vitreous State Laboratory (VSL) of The Catholic University of America (CUA) for ORP to increase the waste loadings and processing rates of HLW glass formulations.
WASTE LOADING ENHANCEMENTS FOR HANFORD LAW GLASSES VLS-10R1790-1 FINAL REPORT REV 0 12/1/2010
About 50 million gallons of high-level mixed waste is currently stored in underground tanks at The United States Department of Energy's (DOE's) Hanford site in the State of Washington. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will provide DOE's Office of River Protection (ORP) with a means of treating this waste by vitrification for subsequent disposal. The tank waste will be separated into low- and high-activity waste fractions, which will then be vitrified respectively into Immobilized Low Activity Waste (ILAW) and Immobilized High Level Waste (IHLW) products. The ILAW product will be disposed in an engineered facility on the Hanford site while the IHLW product will likely be directed to a national deep geological disposal facility for high-level nuclear waste. The ILAW and IHLW products must meet a variety of requirements with respect to protection of the environment before they can be accepted for disposal. The Office of River Protection is currently examining options to optimize the Low Activity Waste (LAW) Facility and LAW glass waste form. One option under evaluation is to enhance the waste processing rate of the vitrification plant currently under construction. It is likely that the capacity of the LAW vitrification plant can be increased incrementally by implementation of a variety of low-risk, high-probability changes, either separately or in combination. These changes include: (1) Operating at the higher processing rates demonstrated at the LAW pilot melter; (2) Increasing the glass pool surface area within the existing external melter envelope; (3) Increasing the glass waste loading; and (4) Operating the melter at a slightly higher temperature. The Vitreous State Laboratory (VSL) of The Catholic University of America (CUA) and Energy Solutions, Inc. have evaluated several of these potential incremental improvements for ORP in support of its evaluation of WTP LAW facility optimization. Some of these incremental improvements have been tested at VSL including increasing the waste loading, increasing the processing temperature, and increasing the fraction of the sulfur in the feed that is partitioned to the off-gas (in the event that a decision is made to break the present WTP recycle loop). These approaches successfully demonstrated increases in glass production rates and significant increases in sulfate incorporation at the nominal melter operating temperature of 1150 C and at slightly higher than nominal glass processing temperatures. Subsequent tests demonstrated further enhancement of glass formulations for all of the LAW waste envelopes, thereby reducing the amount of glass to be produced by the WTP for the same amount of waste processed. The next phase of testing determined the applicability of these improvements over the expected range of sodium and sulfur concentrations for Hanford LAW. This approach was subsequently applied to an even wider range of LAW wastes types, including those with high potassium concentration. The feasibility of formulating higher waste loading glasses using SnO{sub 2} and V{sub 2}O{sub 5} in place of Fe{sub 2}O{sub 3} and TiO{sub 2} as glass former additives was also evaluated. The present report provides data from investigation of the effects of magnesium content (up to {approx}10 wt%) on LAW glass properties and from work to identify improved high waste loading glass formulations that meets all processing and product quality requirements for two waste compositions. The scope of testing is detailed in the Test Plan for this work. A glass composition previously developed and tested at VSL for LAW from tank AN-105 (LAWA187) was varied by substituting Mg for other glass former additives such as Ca, B and Si in an attempt to formulate a glass with improved properties, such as higher waste loading and greater sulfur tolerance. The results were used to reformulate another glass (ORPLG9) developed for LAW from tank AP-101 that contains high concentrations of alkalis (Na and K). Glass formulation goals for this waste were to increase the sulfur tolerance of the glass as well as to decrease refractory corrosion. Each of the two final glass compositions was evaluated to determine the maximum amount of sulfur that can be incorporated into the glass through melter testing. The results from these tests together with earlier work for ORP were evaluated to develop recommendations for the work scope necessary to modify and update the WTP LAW glass formulation correlation algorithm.
Deliberate Motion Analytics Applied to CUAS Sensor Fusion
The Advanced Reactor Safeguards and Security (ARSS) program in the Department of Energy’s Office of Nuclear Energy (DOE-NE) seeks to identify new technology solutions for safeguards and security challenges associated with domestic deployment of advanced nuclear reactors. Research in the ARSS program is investigating alternative physical protection system (PPS) approaches that leverage new detection technologies. This report shows test results from a new form of artificial intelligence (AI) that is called deliberate motion analytics (DMA) when used to spatially and temporally fuse active radar and passive radio frequency (RF) detection that significantly improves detection of uncrewed aircraft systems (UASs). DMA is designed to filter out false positive alarms yet provide highly reliable intrusion detection at nuclear power plants (NPPs) and advanced small modular reactor (ASMR) perimeters. This form of AI is considered to be an enabling technology for security of the future and supports the ARSS investigation of alternative PPSs.