Multipole-based Cable Braid Magnetic Penetration Model for Conducting Wires

In this report, we investigate the effects of conductor losses in a multipole-based cable braid magnetic penetration model. Our multipole model uses a mesh of the actual cable geometry, which enables us to model more complicated structures. After summarizing the first principles model formulation, we consider a one-dimensional array of wires, for which an analytical solution is known in the lossless case. We extend this solution to the lossy case by using a complex-valued radius. We also model this structure analytically using a conformal-mapping solution. We then compare both the self-impedance and the transfer impedance results from our first principles cable braid electromagnetic penetration model to those obtained using the analytical solutions. An analysis for various frequencies (and skin depths) usually encountered in cable modeling is reported. These results are found in good agreement up to a radius to half spacing ratio of about 0.7, demonstrating a robustness needed for many commercial and non-commercial cables.

36 MATERIALS SCIENCE↗

Multipole-based cable braid electromagnetic penetration model: magnetic penetration case

The goal of this paper is to present, for the first time, calculations of the magnetic penetration case of a first principles multipole-based cable braid electromagnetic penetration model. As a first test case, a one-dimensional array of perfect electrically conducting wires, for which an analytical solution is known, is investigated: we compare both the self-inductance and the transfer inductance results from our first principles cable braid electromagnetic penetration model to those obtained using the analytical solution. These results are found in good agreement up to a radius to half spacing ratio of about 0.78, demonstrating a robustness needed for many commercial and non-commercial cables. We then analyze a second set of test cases of a square array of wires whose solution is the same as the one-dimensional array result and of a rhomboidal array whose solution can be estimated from Kley's model. As a final test case, we consider two layers of one-dimensional arrays of wires to investigate porpoising effects analytically. We find good agreement with analytical and Kley's results for these geometries, verifying our proposed multipole model. Note that only our multipole model accounts for the full dependence on the actual cable geometry which enables us to model more complicated cable geometries.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diffusion Models to Construct a First Principles Multipole-Based Cable Braid Model for Conducting Wires in the Time Domain

We describe here diffusion models apt to construct a multipole-based, cable braid time domain model for conducting wires. Implementation details of both a ladder network valid for time-domain signals with all frequency content and an approximate single-stage circuit valid for low-frequency dominated time signals (such as electromagnetic pulses) are reported. This time domain model can be leveraged to treat system-generated electromagnetic pulse events, as well as used to further confirm the correctness of the multipole-based, cable braid frequency domain model.

42 ENGINEERING↗

Magnetic Properties of Cables with Meandering Wires through a Multipole-based Cable Braid Electromagnetic Penetration Model

In this paper, we employ our first principles multipole-based cable braid electromagnetic penetration model to evaluate the transfer inductance of cables exhibiting meandering wires. We concentrate on a cable structure with two wires, and consider the dependence on the transfer inductance as a function of braid angle and amplitude of the meandering. We compare the results from the first principles model to analytical estimations, confirming the accuracy and correctness of our model. In turn, this makes the multipole-based model readily available for the modeling of realistic cable geometries by accounting for the full dependence on the actual cable geometry.

36 MATERIALS SCIENCE↗

The performance of cable braids and terminations to lightning induced transients

The latest specification detailing the test waveforms for indirect lightning transients as applied to aircraft wiring systems specify very high voltages and currents. Although considerable data exists for measuring cable screen leakage using such methods as surface transfer impedance and bulk cable injection, there is little data on the likely core transient level that is likely to be induced from these threats. In particular, the new Waveform 5 at very high current levels (10 kA) is reputed to cause severe cable damage. A range of representative cables were made with various screen termination techniques and screening levels. These were tested first to determine their relative screening performance and then they were subjected to lightning transient testing to all the specified waveforms. Core voltages were measured for each test. Tests were also performed on bundles with fewer wires to determine the failure criteria with Waveform 5 and these tests also include flat conductor cables. The test showed that correctly terminated cable bundles performed well in all the tests and would provide a high level of protection to the electronic systems. The use of overbraides, provided the individual screens are well terminated, appears to be unnecessary.

Crofts, David↗

First Principles Cable Braid Electromagnetic Penetration Model - Potential Impedance Clarification

In this report the lack of assumed connectivity between braid carriers imposes the need to use the original magnetic vector potential formulas for transfer and self impedances rather than the final simplified results in the magnetic coupling and propagation formulas. Each of the magnetic sections in the previous journal article and Sandia report are addressed with references to the appropriate formulas.

42 ENGINEERING↗

Improved Connector Shell for Cable Shields

Cable connector shell improves electrostatic and electromagnetic shielding by electrically connecting cable braid around entire circumference. Connector cable braid is slipped over ferrule and sleeve is slipped over braid, clamping it tightly to shell. Connector shell completely shields cable conductors.

Prisk, A. L.↗

Causes of Cracking of Ignition Cable

The experiments described here show that the cracking at sharp bends, observed in the insulation of internal combustion engine high tension ignition wires after service, is due to a chemical attack upon the rubber by the ozone produced by the electric discharge that takes place at the surface of the cable. This cracking does not occur if the insulating material is not under tension, or if the cable is surrounded by some medium other than air. But it does occur even if the insulation is not subjected to electric stress, provided that the atmosphere near the cable contains ozone. The extent of this cracking varies greatly with the insulating material used. The cracking can be materially reduced by using braided cable and by avoiding sharp bends.

Silsbee, F B↗

Experimental Results of Schlicher's Thrusting Antenna

Experiments were conducted to test the claims by Rex L. Schlicher, et al., (Patent 5,142,86 1) that a certain antenna geometry produces thrust greatly exceeding radiation reaction, when driven by repetitive, fast rise, and relatively slower decay current pulses. In order to test this hypothesis, the antenna was suspended by strings as a 3 in pendulum. Current pulses were fed to the antenna along the suspension path by a very flexible coaxial line constructed from loudspeaker cable and copper braid sheath. When driving the antenna via this cabling, our pulser was capable of sustaining 1200 A pulses at a rate of 30 per second up to a minute. In this way, bursts of pulses could be delivered in synch with the pendulum period in order to build up any motion. However, when using a laser beam passing through a lens attached to the antenna to amplify linear displacement by a factor of at least 25, no correlated motion of the beam spot could be detected on a distant wall. We conclude, in agreement with the momentum theorem of classical electromagnetic theory, that any thrust produced is far below practically useful levels. Hence, within classical electrodynamics, there is little hope of detecting any low level motion that cannot be explained by interactions with surrounding structural steel and the Earth's magnetic field.

Fralick, Gustave C.↗

Improved shielding termination adapter for electrical cable connectors

Termination adapter replaces braid ring and ensures permanent attachment and grounding of sheath wires. The inner ferrule of the termination is slipped inside the exposed ends of the sheath wires and the outer ferrule is placed over the wires and crimped in place to secure the wires for grounding.

Vanasse, M. A.↗

Cable coupling lightning transient qualification

Simulated lightning strike testing of instrumentation cabling on the redesigned solid rocket motor was performed. Testing consisted of subjecting the lightning evaluation test article to simulated lightning strikes and evaluating the effects of instrumentation cable transients on cables within the system tunnel. The maximum short-circuit current induced onto a United Space Boosters, Inc., operational flight cable within the systems tunnel was 92 A, and the maximum induced open-circuit voltage was 316 V. These levels were extrapolated to the worst-case (200 kA) condition of NASA specification NSTS 07636 and were also scaled to full-scale redesigned solid rocket motor dimensions. Testing showed that voltage coupling to cables within the systems tunnel can be reduced 40 to 90 dB and that current coupling to cables within the systems tunnel can be reduced 30 to 70 dB with the use of braided metallic sock shields around cables that are external to the systems tunnel. Testing also showed that current and voltage levels induced onto cables within the systems tunnel are partially dependant on the cables' relative locations within the systems tunnel. Results of current injections to the systems tunnel indicate that the dominant coupling mode on cables within the systems tunnel is not from instrumentation cables but from coupling through the systems tunnel cover seam apertures. It is recommended that methods of improving the electrical bonding between individual sections of the systems tunnel covers be evaluated. Further testing to better characterize redesigned solid rocket motor cable coupling effects as an aid in developing methods to reduce coupling levels, particularly with respect to cable placement within the systems tunnel, is also recommended.

Cook, M.↗

302.2.03 Report on P43OL1139

This document describes the quality issues encountered in bare cable P43OL1139AA00A fabrication and the subsequent investigation performed at LBNL. The cable concerned was placed under L3 quarantine (braiding held, further QC required) in December 2020 upon fabrication due to mid-run facet size increase, and was elevated to L2 quarantine in February 2020 to require a more formal reporting and resolution. The approval (rejection) of this report by L2 on DocDB shall constitute acceptance (rejection) of the fabrication of the bare cable unit P43OL1139AA00A, upon which it may (may not) proceed to braiding and EVMS HO.

36 MATERIALS SCIENCE↗

Intramuscular Contact Lead Filled With Conductive Solution

Proposed sheath for braided-wire intramuscular conductor preserves electrical continuity even if wire breaks. Plastic sheath surrounds conductive solution in which braided wire immersed. At end of cable, wire and sheath crimped together and press-fit in porous titanium electrode. Implanted surgically with aid of device resembling catheter. Used to deliver electrical stimuli to muscles in biomedical research on human and animal physiology, development of prostheses, regeneration of nerves and muscles, and artificial implants.

Bamford, Robert M.↗

Ceramic Fiber Structures for Cryogenic Load-Bearing Applications

This invention is intended for use as a load-bearing device under cryogenic temperatures and/or abrasive conditions (i.e., during missions to the Moon). The innovation consists of small-diameter, ceramic fibers that are woven or braided into devices like ropes, belts, tracks, or cables. The fibers can be formed from a variety of ceramic materials like silicon carbide, carbon, aluminosilicate, or aluminum oxide. The fiber architecture of the weave or braid is determined by both the fiber properties and the mechanical requirements of the application. A variety of weave or braid architectures is possible for this application. Thickness of load-bearing devices can be achieved by using either a 3D woven structure, or a layered, 2D structure. For the prototype device, a belt approximately 0.10 in. (0.25 cm) thick, and 3.0 in. (7.6 cm) wide was formed by layering and stitching a 2D aluminosilicate fiber weave.

Jaskowiak, Martha H.↗

An improved method for electrical cable terminations

Method utilizes a standard terminal lug, a braided wire passed through the barrel and overlapping the top of the lug, and a ferrule to clamp the end of the wire. Electrical connectors can be sterilized and visibly inspected for reliability.

Baker, C. D.↗

Shield to Pin Coupling of Lightning-Like Transients on Payload Umbilical Cables on a Launch Pad

In this paper we describe in-situ testing of a long payload umbilical, on a launch site, injected with “lightning- like” transients and describe resulting pin-to-pin voltages. Injections and voltage measurements near the ground support equipment room, as well as at a location near the payload junction box, are made. The umbilical cables tested include an outer over-braid and the inner conductor coupling is examined for open circuit, short-circuit and various loads representative of spacecraft input impedances. This testing is important because the Kennedy Space Center (KSC) where the lightning occurrence is the highest in the United States, is the primary launch site for Launch Services Program spacecraft customers. Lightning planning is essential but developing a lightning plan is often overlooked or not adequately analyzed leaving the spacecraft vulnerable to time delays or even damage when lightning occurs. At other popular launch sites like Vandenberg Air Force Base (VAFB) where lightning occurs less often, although at the same or greater intensity when it does occur, lightning planning is often completely ignored by the spacecraft. The two major questions to be addressed in the lightning plan are what retesting should be done to establish a “goodness” level and what is the trigger criteria for this testing? The spacecraft will typically use a standard spacecraft check-out procedure to address the necessary retesting, but determining the trigger criteria is often an issue. For instance, a spacecraft needs to understand what their immunity is to a certain lightning magnitude and location. Determining the amount of current that can be coupled onto a spacecraft umbilical can be calculated by using worst case assumptions or measured with current probes and current measurement devices. Spacecraft can also determine what pin-to-pin voltages they are sensitive to, however pin-to-pin voltage measurements are not typically taken during the strike due to the invasive nature of this measurement. In this paper, we present detailed data on the shield to pin voltage transfer functions to provide insight to the spacecraft developers for lightning retest criteria planning. The results from this unique testing opportunity provide essential details on specific coupling mechanisms affecting spacecraft hardware that interfaces with the ground support equipment. This missing link between cable shield currents and payload susceptibility voltages has been methodically tested and representative data presented.

Trout, Dawn↗

Gentle arrester for moving bodies

Wire cable absorbs energy at constant rate with reduced shock and rebounding. Cable typically elongates to 90 percent of its potential, but is surrounded by braided sheath to absorb remaining energy should it break prematurely. Applications of arrester include passenger restraint in air and land vehicles, parachute risers, and ground snatch by aircraft. Possible cable material is type 302 stainless steel.