Search NASA⌕ Search

SEARCH · Search NASA

Results for “cages”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

To Cage or Not to Cage Seagrass; Is There Even a Question?

To Cage or Not to Cage Seagrass; Is There Even a Question? Loraé T. Simpson1, Morgan K. Gilligan1, Douglas M. Scheidt2 1Florida Oceanographic Society, Stuart, FL; 2Herndon Solutions Group/NEMCON, Kennedy Space Center, FL Contact email: lsimpson@floridaocean.org Diminished water quality has led to the decline of seagrasses and their associated ecosystem services in the Banana River Lagoon (BRL), resulting in increased restoration initiatives. Restoration success may be hindered by herbivory and the addition of herbivore exclusion devices may limit grazing stress on newly established seagrasses. These structures may alter sediment dynamics, influencing seagrass productivity. To test whether herbivore exclusion devices impact restoration success and sediment dynamics, we caged half of our seagrass restoration plots in the BRL. Treatments were monitored monthly for seagrass growth, and at three months for porewater nutrients, sediment bulk density, and carbon to nitrogen ratio. On average, caged plots had 87% more seagrass cover and 81% taller blades than control plots, highlighting the importance of caging newly transplanted seagrasses. There was no significant difference in porewater or sediment characteristics between treatments, suggesting that pedogensis and nutrient cycling need extended monitoring to capture changes in temporal scales.

Indian River Lagoon↗

To Cage or Not to Cage Seagrass; Is There Even a Question?

Diminished water quality has led to the decline of seagrasses and their associated ecosystem services in the Banana River Lagoon (BRL), resulting in increased restoration initiatives. Restoration success may be hindered by herbivory and the addition of herbivore exclusion devices may limit grazing stress on newly established seagrasses. These structures may alter sediment dynamics, influencing seagrass productivity. To test whether herbivore exclusion devices impact restoration success and sediment dynamics, we caged half of our seagrass restoration plots in the BRL. Treatments were monitored monthly for seagrass growth, and at three months for porewater nutrients, sediment bulk density, and carbon to nitrogen ratio. On average, caged plots had 87% more seagrass cover and 81% taller blades than control plots, highlighting the importance of caging newly transplanted seagrasses. There was no significant difference in porewater or sediment characteristics between treatments, suggesting that pedogensis and nutrient cycling need extended monitoring to capture changes in temporal scales.

Indian River Lagoon↗

Metabolic Cages for a Space Flight Model in the Rat

A variety of space flight models are available to mimic the physiologic changes seen in the rat during weightlessness. The model reported by Wronski and Morey-Holton has been widely used by many investigators, in musculoskeletal physiologic studies especially, resulting in accumulation of an extensive database that enables scientists to mimic space flight effects in the 1-g environment of Earth. However, information on nutrition or gastrointestinal and renal function in this space flight model is limited by the difficulty in acquiring uncontaminated metabolic specimens for analysis. In the Holton system, a traction tape harness is applied to the tail, and the rat's hindquarters are elevated by attaching the harness to a pulley system. Weight-bearing hind limbs are unloaded, and there is a headward fluid shift. The tail-suspended rats are able to move freely about their cages on their forelimbs and tolerate this procedure with minimal signs of stress. The cage used in Holton's model is basically a clear acrylic box set on a plastic grid floor with the pulley and tail harness system attached to the open top of the cage. Food is available from a square food cup recessed into a corner of the floor. In this system, urine, feces, and spilled food fall through the grid floor onto absorbent paper beneath the cage and cannot be separated and recovered quantitatively for analysis in metabolic balance studies. Commercially available metabolic cages are generally cylindrical and have been used with a centrally located suspension apparatus in other space flight models. The large living area, three times as large as most metabolic cages, and the free range of motion unique to Holton's model, essential for musculoskeletal investigations, were sacrificed. Holton's cages can accommodate animals ranging in weight from 70 to 600 g. Although an alternative construction of Holton's cage has been reported, it does not permit collection of separate urine and fecal samples. We describe the modifications to Holton's food delivery system, cage base, and the addition of a separator system for the collection of urine and fecal samples for metabolic and nutrition studies in the tail suspension model.

Harper, Jennifer S.↗

Cage stability analysis for SSME HPOTP bearings

A numerical model of cage motion (CAGEDYN) was used to analyze the stability of bearing cages in the Space Shuttle main engine (SSME) high pressure oxygen turbopump (HPOTP). The stability of existing bearing geometries, as well as perturbations of these geometries, was analyzed for various operating conditions. Results of the analyses show that some combinations of operating parameters, exacerbated by the sparse lubrication that exist in the HPOTP bearings, can cause unstable cage oscillations. Frequencies of cage oscillations were predicted by the CAGEDYN numerical model by Fourier analysis of predicted cage motions. Under conditions that cause unstable cage motion, high frequency oscillations were predicted that could cause premature cage failures.

Merriman, T. L.↗

Investigation of instability, dynamic forces, and effect of dynamic loading on strength of cages for the bearings in the high pressure oxygen turbopumps for the space shuttle main engine

Experiments were performed to determine the effect of cyclic loading on bearing cage strength. A long term working tensile load of approximately 1300 N (300 lbs) was found to be the likely maximum. Higher loads caused a decrease in cage tensile strength after the 125,000 cycle testing period. Poisson's ratio in compression was found to be highly dependent upon the direction of the fiberglass plies. At room temperature the value was 0.15 with the plies and 0.68 across the plies. At -196 C (-321 F), the value with the plies was 0.20. The results of the analyses conducted have again demonstrated the critical need for improved lubrication in the high pressure oxygen turbopump bearings. Lubricant films with low shear strength and low friction coefficients promote cage stability and decrease ball/cage forces during marginal operating conditions. The analysis of the effect of combined bearing loads on ball/cage loads has identified a radial load of 3600 N (800 lbs) as the maximum for the current clearance of the balls and cage pockets. Liquid oxygen impinging on the cage in the direction of rotation was found to enhance cage stability.

Dufrane, K. F.↗

Comparison of Performance of Experimental and Conventional Cage Designs and Materials for 75-millimeter-bore Cylindrical Roller Bearings at High Speed

The results of two investigations, one to determine the relative merits of four experimental and two conventional design 75-millimeter-bore (size 215) cylindrical roller bearings and one to determine the relative merits of nodular iron and bronze as cage materials for this size and type of bearing, are presented in this report. Nine test bearings were operated over a range of dn values (product of bearing bore in mm and shaft speed in r.p.m) from 0.3 x 10(6) to 2.3 x 20(6), radial loads for 7 to 1613 pounds, and oil flows from 2 to 8 pounds per minute with a single-jet circulatory oil feed. Of the six bearings used to evaluate designs, four were experimental types with outer-race-riding cages and inner-race-guided rollers, and two were conventional types, one with outer-race-guided rollers and cage and one with inner-race-guided rollers and cage. Each of these six test bearings was equipped with a different design cage made of nodular iron. The experimental combination of an outer-race-riding cage with a straight-through outer race and inner-race-guided rollers was found to give the best over-all performance based on limiting dn values and bearing temperatures.

Anderson, William J↗

Provision Of Carbon Nanotube Bucky Paper Cages For Immune Shielding Of Cells, Tissues, and Medical Devices

System and method for enclosing cells and/or tissue, for purposes of growth, cell differentiation, suppression of cell differentiation, biological processing and/or transplantation of cells and tissues (biological inserts), and for secretion, sensing and monitoring of selected chemical substances and activation of gene expression of biological inserts implanted into a human body. Selected cells and/or tissue are enveloped in a "cage" that is primarily carbon nanotube Bucky paper, with a selected thickness and porosity. Optionally, selected functional groups, proteins and/or peptides are attached to the carbon nanotube cage, or included within the cage, to enhance the growth and/or differentiation of the cells and/or tissue, to select for certain cellular sub-populations, to optimize certain functions of the cells and/or tissue and/or to optimize the passage of chemicals across the cage surface(s). A cage system is also used as an immuns shield and to control operation of a nano-device or macroscopic device, located within the cage, to provide or transform a selected chemical and/or a selected signal.

Loftus, David J.↗

Effects of Muscle Atrophy on Motor Control: Cage-size Effects

Two populations of male Sprague-Dawley rats were raised either in conventional minimum-specification cages or in a larger cage. When the animals were mature (125 to 150 d), the physiological status of the soleus (SOL) and extensor digitorum longus (EDL) muscles of the small- and large-cage animals were compared. Analysis of whole-muscle properties including the performance of the test muscle during a standardized fatigue test in which the nerve to the test muscle was subjected to supramaximal intermittent stimulation shows: (1) the amplitude, area, mean amplitude, and peak-to-peak rate of the compound muscle action potential decreased per the course of the fatigue test; (2) cage size did not affect the profile of changes for any of the action-potential measurements; (3) changes exhibited in the compound muscle action potential by SOL and EDL were substantially different; and (4) except for SOL of the large-cage rats, there was a high correlation between all four measures of the compound muscle action potential and the peak tetanic force during the fatigue test; i.e., either the electrical activity largely etermines the force profile during the fatigue test or else contractile-related activity substantially affects the compound muscle action potential.

Stuart, D. G.↗

Evaluation of transfer films of Salox M on 440C for HPOTP bearing cage applications, task 119

The objective of the task was to evaluate the suitability of a bronze-filled polytetra fluoroethylene (Salox M) as the cage material in Space Shuttle Main Engine (SSME) high pressure oxygen turbo pump (HPOTP) bearings. The role of the cage pocket material will be to provide a transferred lubricating interface at the ball-race contact region. A series of experiments was conducted which involved block-on-ring tests (the block was the polytetrafluoroethylene (PTFE) -filled material and the ring was through-hardened 440C steel) and high speed traction tests of two 440C disks with one disk rubbed with a PTFE block to generate a transfer film. Measurements included post test visual observations of the condition of the 440C, wear rate measurements of the blocks, and traction measurements between the disks. It was observed that both Salox M and glass-filled PTFE (Armalon) transferred PTFE to 440C at cryogenic temperatures. Bronze is also transferred to uncoated 440C from the Salox M. At room temperature no PTFE transfer was observed in the high speed disk tests due to severe frictional heating, although bronze transfer still occurred with the bronze-PTFE Salox M material. Since the bearing will operate at cryogenic temperature, transfer films are very probable. Salox M wore slightly, although probably tolerably, more than glass-filled PTFE against 440C. However, Salox M is clearly less abrasive to 440C than is the glass-filled material. When the surface layer of PTFE is depleted from the glass-filled material, the glass fibers tend to seriously abrade the steel. This problem does not occur with Salox M. The surface roughness studies indicate that smooth balls are quite reasonable for transfer films. No significant difference in wear rates of the candidate cage materials was observed when the 440C surface finish was increased from 0.025 micron to 0.1 micron cla. At higher levels of roughness, the wear rate increased. Two surface coatings (MoS2 and TiN) were tested. The surface coatings tended to reduce the Salox M wear rate and reduce bronze transfer. PTFE transfer at cryogenic temperatures still occurred with the surface coatings. Two cage design concepts are presented utilizing Salox M material. One design involves a metal-reinforced Salox M cage, while the second design uses Salox M inserts in a metal structure.

Barber, S. A.↗

A metabolic cage for the hindlimb suspended rat

Hindlimb suspension has been successfully used to simulate the effects of microgravity in rats. The cage and suspension system developed by E. R. Holton is designed to produce a headward shift of fluid and unload the hindlimbs in rodents, causing changes in bone and muscle similar to those in animals and humans exposed to spaceflight. While the Holton suspension system simulates many of the conditions observed in the spaceflight animal, it does not provide for the collection of urine and feces needed to monitor some metabolic activities. As a result, only limited information has been gathered on the nutritional status, and the gastrointestinal and renal function of animals using that model. Although commercial metabolic cages are available, they are usually cylindrical and require a centrally located suspension system and thus, do not readily permit movement of the rats. The limited floor space of commercial cages may affect comparisons with studies using the Holton model which has more than twice the living space of most commercially available cages. To take advantage of the extra living space and extensive data base that has been developed with the Holton model, Holton's cage was modified to make urine and fecal collections possible.

Evans, J.↗

Effects of Cage Type and NASA Rodent Food Bar in Male Sprague-Dawley Rats

Early prototype caging for the rodent Advanced Animal Habitat (P-AAH) for the International Space Station (ISS) is currently being tested. In this five week study, effects of the wire-bottom P-AAH cages and specialized NASA rodent food bars (FB) were compared to standard vivarium cages (VIV) with corn-cob, litter-filled bottoms, and standard Purina rat chow (CH). Ninety-six male Sprague-Dawley rats were divided into four treatment groups (24 rats/treatment): Group 1) VIV+CH, Group 2) P-AAH+CH, Group 3) VIV+FB, and Group 4) P-AAH+FB. Each VIV and P-AAH cage housed three and six rats, respectively. After five weeks of treatment rats were weighed, euthanized, and blood samples were collected. Weights of liver (LIV), kidney (KID), brain (BRN), epididymal fat (EPI), and perirenal fat (PERI) were also measured. Statistical analysis to compare differences between groups was performed by standard analysis of variance procedures (ANOVA) with a significance level of pLO.05. Results indicated P-AAH housed rats had significantly lower body weights (BW), LIV weights, and LIV/BW than VIV housed rats. FB fed rats had significantly lower blood urea nitrogen (BUN) levels and LIV/BW than CH fed rats. In addition, FB fed rats had significantly higher cholesterol (CHOL) levels, EPI/BW, PERI/BW, and total fat (EPI+PERI)/BW than CH fed rats. The P-AAH+FB group had significantly lower EPI, BRN, and total fat than VIV+FB rats. VIV+FB rats had significantly higher BRN, EPI, PERI, and total fat than VIV+CH rats. Triglycerides (TG), KID, KID/BW, and BRN/BW were not significantly different among treatment groups. These findings provide valuable information regarding cage design and food bar suitability for long-term use on the ISS.

Lau, Angela↗

Improved mouse cage provides versatility and ease in handling laboratory mice

Mouse cage system provides versatility and ease in handling laboratory mice, cleaning their cages, and collecting uncontaminated metabolic test specimens. The cage, compact and free standing, contains a screened bottom and funnel channel to collect waste. The feed is in the cage top and thereby separates the food and waste.

Jones, N. D.↗

Evaluation of the effects of hypergravity exposure and caging restraint on bone mineralization in the Beagle by in vivo photon absorptiometry

Photon absorptiometry was used to evaluate bone mineral kinetics associated with normal development and the possible perturbations to bone development resulting from hypergravity exposure over a period of six months in developing Beagles. A series of seven measurements were performed at specific times with the first measurement prior to treatment and subsequent measurements at 2, 5, 9, 14, 20 and 26 weeks from the onset of the experiment. Four groups of six male Beagle pups, ranging in age from 85 to 92 days were studied. Two groups were chronically exposed to hypergravity treatments by centrifugation of 2.0 G (18.0 RPM, 11.7 ft radius) and 2.6 G (18.0 RPM, 19.8 ft radius) for the 26 week period. A third group of six dogs served as a caged control to evaluate possible changes due to confinement in small plexiglass cages similar to those of the centrifuge. Thus this control group was subjected to limited exercise due to caging restraint. The fourth group of animals was housed in open runs to allow exercise without the spatial confinement of the smaller plexiglass cages. Results show highly significant differences in body weight, bone length, increase in bone density of control group relative to other groups, and a decrease in bone mineral content in the two gravity treated groups.

Fisher, G. L.↗

Effect of cage design on characteristics of high-speed-jet-lubricated 35-millimeter-bore ball bearing

Parametric tests were conducted with a 35 mm bore angular contact ball bearing with a double outer land guided cage. Provisions were made for jet lubrication and outer-ring cooling of the bearing. Test conditions included a combined thrust and radial load at nominal shaft speeds of 48,000 rpm, and an oil-in temperature of 394 K (250 F). Successful operation of the test bearing was accomplished up to 2.5 million DN. Test results were compared with those obtained with similar bearing having a single outer land guided cage. Higher temperatures were generated with the double outer land guided cage bearing, and bearing power loss and cage slip were greater. Cooling the outer ring resulted in a decrease in overall bearing operating temperature.

Schuller, F. T.↗

Biocentrifuge system capable of exchanging specimen cages while in operational mode

The centrifuge comprises a generally circular, rotatably mounted frame carrying a plurality of removable and replaceable cages for the animal specimens. Pairs of opposing cages may be removed from the frame while it is rotating by means of a cage exchanger which rotates concentrically within the centrifuge and the speed of which is controlled independently of the frame speed. An image rotator is provided for selective observation of the rotating animals. The system further includes a waste conveyor system, a food supply system, and a water supply system for each cage for creating a life sustaining environment so that the animals can live in the rotating centrifuge for extended periods.

Belew, R. R.↗

Effect of double density caging during Space Shuttle transport of laboratory rats

Male Sprague Dawley rats were housed in groups of four in polycarbonate cages at recommended density and thermal environmental conditions for 14 days prior to testing to ensure uniform acclimation to those conditions. Body weights averaged 286 +/- 7 g at the end of acclimation. Rat cages were assigned randomly to three treatments: (1) 4 rats/polycarbonate cage (877 sq cm, 20.3 cm high, 220 sq cm/rat), (2) 4 rats/mock AEM (MAEM) (620 sq cm, 155 sq cm/rat), and (3) 8 rats/MAEM (620 sq cm, 77.5 sq cm/rat). A comparison between the MAEM-DD and MAEM-SD treatments was done to determine if doubling rat density in AEM's stressed the rats. A comparison among MAEM treatments and the PC treatment was done to determine if any stress indications were due to the AEM. During this density challenge phase, all treatments were maintained at the same thermal environmental conditions (22.5 C and 50 percent RH) for 10 days. After the density challenge phase, half the rats from each group were sacrificed for body tissue and fluid analyses. The remaining half of the rats were housed at a density of 4 rats/cage in polycarbonate cages at normal thermal environmental conditions for an additional 10 days to determine if there were any differences in responses between treatments after a recovery period. The remaining rats were examined and sacrificed for body tissue and fluid analyses at the end of the recovery phase.

Riskowski, G. L.↗

AAH Cage Out-Link and In-Link Antenna Characterization

This final report encapsulates the accomplishments of the third year of work on an Advanced Biotelemetry System (ABTS). Overall MU/ABTS project objectives are to provide a biotelemetry system that can collect data from and send commands to an implanted biotransceiver. This system will provide for studies of rodent development in space. The system must be capable of operating in a metal animal cage environment. An important goal is the development of a small, "smart", micropower, implantable biotransceiver with eight-channel data output and single channel command input capabilities with the flexibility for easy customization for a variety of physiologic investigations. The NASA Ames/Marquette University Joint Research work has been devoted to the system design of such a new state of the art biotelemetry system, having multiple physiologic inputs, and bi-directional data transfer capabilities. This work has provided a successful prototype system that connects, by two-way radio links, an addressable biotelemetry system that provides communication between an animal biotelemeter prototype and a personal computer. The operational features of the prototype system are: (1) two-way PCM communication with implanted biotelemeter; (2) microcontroller based biotelemeter; (3) out-link: wideband FSK (60 kBaud); (4) in-link: OOK (2.4 kbaud); (5) septum antenna arrays (In/Out-Links); and (6) personal computer data interface. The important requirement of this third year's work, to demonstrate two-way communication with transmit and receive antennas inside the metal animal cage, has been successfully accomplished. The advances discussed in this report demonstrate that the AAH cage antenna system can provide Out-link and In-link capability for the ABTS bi-directional telemetry system, and can serve as a benchmark for project status. Additions and enhancements to the most recent (April 1997) prototype cage and antenna have been implemented. The implementation, testing, and documentation was accomplished at the Biotelemetry Laboratory at Marquette University with Out-Link (slot) antenna design assistance was provided.

Jeutter, Dean C.↗