Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibrated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Radiometric Calibration of the AWiFS Sensor and a Cross-calibration Enhanced Vicarious Calibration Technique

Using vicarious calibration validation of moderate resolution sensors such as AWiFS is complicated by requiring more land area to ensure proper registration and sufficient pixel numbers. A trial AWiFS calibration was performed on a grass site that consisted of two dramatically different grass heights. Ground truth data was collected over relatively small areas representing only a few pixels. The radiometric gain results for each of these areas will be reported. To enhance this analysis, since a near coincidence high resolution image was collected, the high resolution data was effectively resized to produce pixels comparable to AWiFS and the atmospheric model was used to produce a top of canopy radiance map. Multiple uniform vegetated areas of several radiances were then identified and subsequently propagated to the top of atmosphere viewpoint of the moderate resolution (AWiFS) satellite. The radiometric gain was then calculated based on the vendor high resolution satellite gains (for the 3 bands with comparable wavelengths). Band-to-band conversion was performed assuming a hyperspectral reflectance based on the standard vegetated site. The initial comparison produces AWiFS radiometric gain values that agree to better than 10% of the values measured using the standard vicarious gain technique.

Aaron, David↗

Improved Primary Reference Cell Calibrations for Higher Accuracy Photovoltaic Cell and Module Performance Measurements

The adoption of photovoltaic (PV) modules for clean electricity relies on accurate measurements of their performance, which are essential for estimating their energy production potential. Herein, the calibration chain of PV cells and modules, with particular emphasis on primary reference cell calibrations, is discussed. Also, herein, the direct sunlight method the group has developed for these calibrations is presented and critical improvements and upgrades that lead to calibration uncertainty as low as 0.45% are discussed. The ultimate motivation behind this work is to provide low‐uncertainty performance measurements of PV modules, and lowering the calibration uncertainty of primary reference cells is a key first step toward achieving this goal. As the use of solar electricity continues to grow, the demand for primary reference cell calibrations inevitably increases beyond what the small handful of primary calibration laboratories can provide today. Therefore, this work can serve as a useful guide for implementing primary PV reference cell calibrations using the outdoor method, as well as outlining the critical elements required to make these calibrations highly accurate.

Osterwald, Carl R.↗

Waveguide Calibrator for Multi-Element Probe Calibration

A calibrator, referred to as the spider design, can be used to calibrate probes incorporating multiple acoustic sensing elements. The application is an acoustic energy density probe, although the calibrator can be used for other types of acoustic probes. The calibrator relies on the use of acoustic waveguide technology to produce the same acoustic field at each of the sensing elements. As a result, the sensing elements can be separated from each other, but still calibrated through use of the acoustic waveguides. Standard calibration techniques involve placement of an individual microphone into a small cavity with a known, uniform pressure to perform the calibration. If a cavity is manufactured with sufficient size to insert the energy density probe, it has been found that a uniform pressure field can only be created at very low frequencies, due to the size of the probe. The size of the energy density probe prevents one from having the same pressure at each microphone in a cavity, due to the wave effects. The "spider" design probe is effective in calibrating multiple microphones separated from each other. The spider design ensures that the same wave effects exist for each microphone, each with an indivdual sound path. The calibrator s speaker is mounted at one end of a 14-cm-long and 4.1-cm diameter small plane-wave tube. This length was chosen so that the first evanescent cross mode of the plane-wave tube would be attenuated by about 90 dB, thus leaving just the plane wave at the termination plane of the tube. The tube terminates with a small, acrylic plate with five holes placed symmetrically about the axis of the speaker. Four ports are included for the four microphones on the probe. The fifth port is included for the pre-calibrated reference microphone. The ports in the acrylic plate are in turn connected to the probe sensing elements via flexible PVC tubes. These five tubes are the same length, so the acoustic wave effects are the same in each tube. The flexible nature of the tubes allows them to be positioned so that each tube terminates at one of the microphones of the energy density probe, which is mounted in the acrylic structure, or the calibrated reference microphone. Tests performed verify that the pressure did not vary due to bends in the tubes. The results of these tests indicate that the average sound pressure level in the tubes varied by only 0.03 dB as the tubes were bent to various angles. The current calibrator design is effective up to a frequency of approximately 4.5 kHz. This upper design frequency is largely due to the diameter of the plane-wave tubes.

Sommerfeldt, Scott D.↗

Global Space-Based Inter-Calibration System Reflective Solar Calibration Reference: From Aqua MODIS to S-NPP VIIRS

The MODIS has successfully operated on-board the NASA's EOS Terra and Aqua spacecraft for more than 16 and 14 years, respectively. MODIS instrument was designed with stringent calibration requirements and comprehensive on-board calibration capability. In the reflective solar spectral region, Aqua MODIS has performed better than Terra MODIS and, therefore, has been chosen by the Global Space-based Inter-Calibration System (GSICS) operational community as the calibration reference sensor in cross-sensor calibration and calibration inter-comparisons. For the same reason, it has also been used by a number of earth observing sensors as their calibration reference. Considering that Aqua MODIS has already operated for nearly 14 years, it is essential to transfer its calibration to a follow-on reference sensor with a similar calibration capability and stable performance. The VIIRS is a follow-on instrument to MODIS and has many similar design features as MODIS, including their on-board calibrators (OBC). As a result, VIIRS is an ideal candidate to replace MODIS to serve as the future GSICS reference sensor. Since launch, the S-NPP VIIRS has already operated for more than 4 years and its overall performance has been extensively characterized and demonstrated to meet its overall design requirements. This paper provides an overview of Aqua MODIS and S-NPP VIIRS reflective solar bands (RSB) calibration methodologies and strategies, traceability, and their on-orbit performance. It describes and illustrates different methods and approaches that can be used to facilitate the calibration reference transfer, including the use of desert and Antarctic sites, deep convective clouds (DCC), and the lunar observations.

Xiong, Xiaoxiong↗

MODIS airborne simulator visible and near-infrared calibration, 1991 FIRE-Cirrus field experiment. Calibration version: FIRE King 1.1

Calibration of the visible and near-infrared channels of the MODIS Airborne Simulator (MAS) is derived from observations of a calibrated light source. For the 1991 FIRE-Cirrus field experiment, the calibrated light source was the NASA Goddard 48-inch integrating hemisphere. Laboratory tests during the FIRE Cirrus field experiment were conducted to calibrate the hemisphere and from the hemisphere to the MAS. The purpose of this report is to summarize the FIRE-Cirrus hemisphere calibration, and then describe how the MAS was calibrated from observations of the hemisphere data. All MAS calibration measurements are presented, and determination of the MAS calibration coefficients (raw counts to radiance conversion) is discussed. Thermal sensitivity of the MAS visible and near-infrared calibration is also discussed. Typically, the MAS in-flight is 30 to 60 degrees C colder than the room temperature laboratory calibration. Results from in-flight temperature measurements and tests of the MAS in a cold chamber are given, and from these, equations are derived to adjust the MAS in-flight data to what the value would be at laboratory conditions. For FIRE-Cirrus data, only channels 3 through 6 were found to be temperature sensitive. The final section of this report describes comparisons to an independent MAS (room temperature) calibration by Ames personnel using their 30-inch integrating sphere.

Arnold, G. Thomas↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Calibrating a 3-Axis Accelerometer Instrument with a Less Accurate Calibration Device Part 1: Mathematical Methodology

A three-axis accelerometer instrument (3xAI) can provide the angular attitude of a 3D object using the gravity vector (g) as the sole reference. Calibrating such an instrument requires placing it at known (to some accuracy plus uncertainty) angular articulations with respect to g. This paper will show a potential process for calibrating a 3xAI by using a 2-axis rotary system (calibration device) to provide these articulations. Any calibration device (CD) with such capacity will contain internal misalignments. These misalignments, even if made relatively small or approximated to zero in the kinematics model (KM), can be detrimental to the calibration of the instrument when high measurement accuracy is required. This is especially true if the selected set of articulations chosen for calibration do not include their symmetrical counterpoints (a point where the misalignment has equal magnitude but is opposite in direction to a point chosen). The consequence of not including the combination, point and counterpoint, for any misalignment involved in the calibration, results in a biased instrument. This paper will demonstrate a calibration of the instrument using symbolic math resulting in a closed-form solution of the instrument coefficients. The main objective is to show the impact of all the CD misalignments to the instrument coefficients. This process is the basis for a more sophisticated method (shown in a future paper) for obtaining the instrument coefficients while simultaneously obtaining an estimate of the calibration device internal misalignments.

Angle↗

MODIS airborne simulator visible and near-infrared calibration, 1992 ASTEX field experiment. Calibration version: ASTEX King 1.0

Calibration of the visible and near-infrared (near-IR) channels of the MODIS Airborne Simulator (MAS) is derived from observations of a calibrated light source. For the 1992 Atlantic Stratocumulus Transition Experiment (ASTEX) field deployment, the calibrated light source was the NASA Goddard 48-inch integrating hemisphere. Tests during the ASTEX deployment were conducted to calibrate the hemisphere and then the MAS. This report summarizes the ASTEX hemisphere calibration, and then describes how the MAS was calibrated from the hemisphere data. All MAS calibration measurements are presented and determination of the MAS calibration coefficients (raw counts to radiance conversion) is discussed. In addition, comparisons to an independent MAS calibration by Ames personnel using their 30-inch integrating sphere is discussed.

Arnold, G. Thomas↗

Continued Monitoring of Landsat Reflective Band Calibration Using Pseudo-Invariant Calibration Sites

Though both of the current Landsat instruments, Landsat-7 Enhanced Thematic Mapper+ (ETM+) and Landsat-5 Thematic Mapper (TM), include on-board calibration systems, since 2001, pseudo-invariant calibration sites (PICS) have been added to the suite of metrics to assess the instruments calibration. These sites do not provide absolute calibration data since there are no ground measurements of the sites, but in monitoring these PICS over time, the relative calibration can be tracked. The sites used by the Landsat instruments are primarily in the Saharan Desert. To date, the trending from the PICS sites has confirmed that most of the degradation seen in the ETM+ on-board calibration systems is likely not degradation of the instrument, but rather degradation of the calibration systems themselves. However, the PICS data show statistically significant degradation (at 2-sigma) in all the reflective spectral bands of up to -0.22%/year since July 2003. For the TM, the PICS were instrumental in updating the calibration in 2007 and now suggest two bands may require another update. The data show a statistically significant degradation (at 2-sigma) in Bands 1 and 3 of -0.27 and -0.15%/year, respectively, since March 1999. The data filtering and processing methods are currently being reviewed but these PICS results may lead to an update in the reflective band calibration of both Landsat-7 and Landsat-5.

Barsi, Julia A.↗

Results from Source-Based and Detector-Based Calibrations of a CLARREO Calibration Demonstration System

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission is formulated to determine long-term climate trends using SI-traceable measurements. The CLARREO mission will include instruments operating in the reflected solar (RS) wavelength region from 320 nm to 2300 nm. The Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO and facilitates testing and evaluation of calibration approaches. The basis of CLARREO and SOLARIS calibration is the Goddard Laser for Absolute Measurement of Response (GLAMR) that provides a radiance-based calibration at reflective solar wavelengths using continuously tunable lasers. SI-traceability is achieved via detector-based standards that, in GLAMRs case, are a set of NIST-calibrated transfer radiometers. A portable version of the SOLARIS, Suitcase SOLARIS is used to evaluate GLAMRs calibration accuracies. The calibration of Suitcase SOLARIS using GLAMR agrees with that obtained from source-based results of the Remote Sensing Group (RSG) at the University of Arizona to better than 5 (k2) in the 720-860 nm spectral range. The differences are within the uncertainties of the NIST-calibrated FEL lamp-based approach of RSG and give confidence that GLAMR is operating at 5 (k2) absolute uncertainties. Limitations of the Suitcase SOLARIS instrument also discussed and the next edition of the SOLARIS instrument (Suitcase SOLARIS- 2) is expected to provide an improved mechanism to further assess GLAMR and CLARREO calibration approaches. (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

Angal, Amit↗

Cross-calibration of liquid and solid QCT calibration standards: corrections to the UCSF normative data

Quantitative computed tomography (QCT) has been shown to be a precise and sensitive method for evaluating spinal bone mineral density (BMD) and skeletal response to aging and therapy. Precise and accurate determination of BMD using QCT requires a calibration standard to compensate for and reduce the effects of beam-hardening artifacts and scanner drift. The first standards were based on dipotassium hydrogen phosphate (K2HPO4) solutions. Recently, several manufacturers have developed stable solid calibration standards based on calcium hydroxyapatite (CHA) in water-equivalent plastic. Due to differences in attenuating properties of the liquid and solid standards, the calibrated BMD values obtained with each system do not agree. In order to compare and interpret the results obtained on both systems, cross-calibration measurements were performed in phantoms and patients using the University of California San Francisco (UCSF) liquid standard and the Image Analysis (IA) solid standard on the UCSF GE 9800 CT scanner. From the phantom measurements, a highly linear relationship was found between the liquid- and solid-calibrated BMD values. No influence on the cross-calibration due to simulated variations in body size or vertebral fat content was seen, though a significant difference in the cross-calibration was observed between scans acquired at 80 and 140 kVp. From the patient measurements, a linear relationship between the liquid (UCSF) and solid (IA) calibrated values was derived for GE 9800 CT scanners at 80 kVp (IA = [1.15 x UCSF] - 7.32).(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Program Space Physiology and Countermeasures↗

Dark Energy Survey Year 3 results: calibration of lens sample redshift distributions using clustering redshifts with BOSS/eBOSS

ABSTRACT We present clustering redshift measurements for Dark Energy Survey (DES) lens sample galaxies used in weak gravitational lensing and galaxy clustering studies. To perform these measurements, we cross-correlate with spectroscopic galaxies from the Baryon Acoustic Oscillation Survey (BOSS) and its extension, eBOSS. We validate our methodology in simulations, including a new technique to calibrate systematic errors that result from the galaxy clustering bias, and we find that our method is generally unbiased in calibrating the mean redshift. We apply our method to the data, and estimate the redshift distribution for 11 different photometrically selected bins. We find general agreement between clustering redshift and photometric redshift estimates, with differences on the inferred mean redshift found to be below |Δz| = 0.01 in most of the bins. We also test a method to calibrate a width parameter for redshift distributions, which we found necessary to use for some of our samples. Our typical uncertainties on the mean redshift ranged from 0.003 to 0.008, while our uncertainties on the width ranged from 4 to 9 per cent. We discuss how these results calibrate the photometric redshift distributions used in companion papers for DES Year 3 results.

79 ASTRONOMY AND ASTROPHYSICS↗

Uncertainty Analysis of Inertial Model Attitude Sensor Calibration and Application with a Recommended New Calibration Method

Statistical tools, previously developed for nonlinear least-squares estimation of multivariate sensor calibration parameters and the associated calibration uncertainty analysis, have been applied to single- and multiple-axis inertial model attitude sensors used in wind tunnel testing to measure angle of attack and roll angle. The analysis provides confidence and prediction intervals of calibrated sensor measurement uncertainty as functions of applied input pitch and roll angles. A comparative performance study of various experimental designs for inertial sensor calibration is presented along with corroborating experimental data. The importance of replicated calibrations over extended time periods has been emphasized; replication provides independent estimates of calibration precision and bias uncertainties, statistical tests for calibration or modeling bias uncertainty, and statistical tests for sensor parameter drift over time. A set of recommendations for a new standardized model attitude sensor calibration method and usage procedures is included. The statistical information provided by these procedures is necessary for the uncertainty analysis of aerospace test results now required by users of industrial wind tunnel test facilities.

Tripp, John S.↗

Single Vector Calibration System for Multi-Axis Load Cells and Method for Calibrating a Multi-Axis Load Cell

A single vector calibration system is provided which facilitates the calibration of multi-axis load cells, including wind tunnel force balances. The single vector system provides the capability to calibrate a multi-axis load cell using a single directional load, for example loading solely in the gravitational direction. The system manipulates the load cell in three-dimensional space, while keeping the uni-directional calibration load aligned. The use of a single vector calibration load reduces the set-up time for the multi-axis load combinations needed to generate a complete calibration mathematical model. The system also reduces load application inaccuracies caused by the conventional requirement to generate multiple force vectors. The simplicity of the system reduces calibration time and cost, while simultaneously increasing calibration accuracy.

Parker, Peter A.↗

Calibrating Historical IR Sensors Using GEO, and AVHRR Infrared Tropical Mean Calibration Models

Long-term, remote-sensing-based climate data records (CDRs) are highly dependent on having consistent, wellcalibrated satellite instrument measurements of the Earth's radiant energy. Therefore, by making historical satellite calibrations consistent with those of today's imagers, the Earth-observing community can benefit from a CDR that spans a minimum of 30 years. Most operational meteorological satellites rely on an onboard blackbody and space looks to provide on-orbit IR calibration, but neither target is traceable to absolute standards. The IR channels can also be affected by ice on the detector window, angle dependency of the scan mirror emissivity, stray-light, and detector-to-detector striping. Being able to quantify and correct such degradations would mean IR data from any satellite imager could contribute to a CDR. Recent efforts have focused on utilizing well-calibrated modern hyper-spectral sensors to intercalibrate concurrent operational IR imagers to a single reference. In order to consistently calibrate both historical and current IR imagers to the same reference, however, another strategy is needed. Large, well-characterized tropical-domain Earth targets have the potential of providing an Earth-view reference accuracy of within 0.5 K. To that effort, NASA Langley is developing an IR tropical mean calibration model in order to calibrate historical Advanced Very High Resolution Radiometer (AVHRR) instruments. Using Meteosat-9 (Met-9) as a reference, empirical models are built based on spatially/temporally binned Met-9 and AVHRR tropical IR brightness temperatures. By demonstrating the stability of the Met-9 tropical models, NOAA-18 AVHRR can be calibrated to Met-9 by matching the AVHRR monthly histogram averages with the Met-9 model. This method is validated with ray-matched AVHRR and Met-9 biasdifference time series. Establishing the validity of this empirical model will allow for the calibration of historical AVHRR sensors to within 0.5 K, and thereby establish a climate-quality IR data record.

Scarino, Benjamin↗

Discrete-Direct Model Calibration and Uncertainty Propagation Method Confirmed on Multi-Parameter Plasticity Model Calibrated to Sparse Random Field Data

A discrete direct (DD) model calibration and uncertainty propagation approach is explained and demonstrated on a 4-parameter Johnson-Cook (J-C) strain-rate dependent material strength model for an aluminum alloy. The methodology's performance is characterized in many trials involving four random realizations of strain-rate dependent material-test data curves per trial, drawn from a large synthetic population. The J-C model is calibrated to particular combinations of the data curves to obtain calibration parameter sets which are then propagated to “Can Crush” structural model predictions to produce samples of predicted response variability. These are processed with appropriate sparse-sample uncertainty quantification (UQ) methods to estimate various statistics of response with an appropriate level of conservatism. This is tested on 16 output quantities (von Mises stresses and equivalent plastic strains) and it is shown that important statistics of the true variabilities of the 16 quantities are bounded with a high success rate that is reasonably predictable and controllable. The DD approach has several advantages over other calibration-UQ approaches like Bayesian inference for capturing and utilizing the information obtained from typically small numbers of replicate experiments in model calibration situations—especially when sparse replicate functional data are involved like force–displacement curves from material tests. The DD methodology is straightforward and efficient for calibration and propagation problems involving aleatory and epistemic uncertainties in calibration experiments, models, and procedures.

42 ENGINEERING↗

Calibration of the NOAA 11 solar backscatter ultraviolet (SBUV/2) ozone data set from 1989 to 1993 using in-flight calibration data and SSBUV

Total ozone and ozone profiles are currently being measured by solar backscatter ultraviolet (SBUV/2) instruments onboard NOAA polar orbiting spacecraft using the backscattered ultraviolet technique. The NOAA 11 SBUV/2 operational data set, reprocessed from January 1989 to May 1993 (version 6), includes an updated algorithm and revised prelaunch and postlaunch calibrations of the geometrical albedo observations used to derive ozone values. The postlaunch calibration revisions remove time dependent errors in the ozone amounts due to instrument drift, while the revised prelaunch calibration corrects the absolute value of retrieved ozone. The prelaunch corrections are a result of calibration checks from in-orbit comparisons of ultraviolet geometric albedos measured by shuttle SBUV (SSBUV) and the NOAA 11 SBUV/2. Geometric albedo comparison data are further corrected using a radiative transfer code to account for the small difference in observing conditions between the two spacecraft. The postlaunch corrections rely on in-flight calibration and solar irradiance data to account for time dependent changes in instrument gain, thermal response, and instrument diffuser degradation over time. Comparison of data from three SSBUV flights, which occurred about one year apart, with concurrent SBUV/2 data provided an independent check of the time dependent change derived from the in-flight calibration data. Time independent corrections result in an increase of about 1% for total ozone, 5% for ozone at 1 mbar, and near 0% at 15 mbar. The time dependent corrections amount to an increase of 2% for total ozone, 10% for ozone near 1 mbar, and 3% at 15 mbar at the end of the current record in May 1993. Recent laboratory studies indicate that the absolute radiance calibrations may still be in error by a few percent which results in ozone profile values that are too low. The SBUV/2 total and ozone profile data are compared to the Nimbus SBUV data during the period when the data overlapped. Total ozone values agree to about 1%, while ozone profile differences range from -4% to +6%, depending on latitude and altitude, relative to SBUV. These differences are not statistically significant given the uncertainties of the two data sets.

Hilsenrath, E.↗