Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibrated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Improved Primary Reference Cell Calibrations for Higher Accuracy Photovoltaic Cell and Module Performance Measurements

The adoption of photovoltaic (PV) modules for clean electricity relies on accurate measurements of their performance, which are essential for estimating their energy production potential. Herein, the calibration chain of PV cells and modules, with particular emphasis on primary reference cell calibrations, is discussed. Also, herein, the direct sunlight method the group has developed for these calibrations is presented and critical improvements and upgrades that lead to calibration uncertainty as low as 0.45% are discussed. The ultimate motivation behind this work is to provide low‐uncertainty performance measurements of PV modules, and lowering the calibration uncertainty of primary reference cells is a key first step toward achieving this goal. As the use of solar electricity continues to grow, the demand for primary reference cell calibrations inevitably increases beyond what the small handful of primary calibration laboratories can provide today. Therefore, this work can serve as a useful guide for implementing primary PV reference cell calibrations using the outdoor method, as well as outlining the critical elements required to make these calibrations highly accurate.

Osterwald, Carl R.↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Dark Energy Survey Year 3 results: calibration of lens sample redshift distributions using clustering redshifts with BOSS/eBOSS

ABSTRACT We present clustering redshift measurements for Dark Energy Survey (DES) lens sample galaxies used in weak gravitational lensing and galaxy clustering studies. To perform these measurements, we cross-correlate with spectroscopic galaxies from the Baryon Acoustic Oscillation Survey (BOSS) and its extension, eBOSS. We validate our methodology in simulations, including a new technique to calibrate systematic errors that result from the galaxy clustering bias, and we find that our method is generally unbiased in calibrating the mean redshift. We apply our method to the data, and estimate the redshift distribution for 11 different photometrically selected bins. We find general agreement between clustering redshift and photometric redshift estimates, with differences on the inferred mean redshift found to be below |Δz| = 0.01 in most of the bins. We also test a method to calibrate a width parameter for redshift distributions, which we found necessary to use for some of our samples. Our typical uncertainties on the mean redshift ranged from 0.003 to 0.008, while our uncertainties on the width ranged from 4 to 9 per cent. We discuss how these results calibrate the photometric redshift distributions used in companion papers for DES Year 3 results.

79 ASTRONOMY AND ASTROPHYSICS↗

Discrete-Direct Model Calibration and Uncertainty Propagation Method Confirmed on Multi-Parameter Plasticity Model Calibrated to Sparse Random Field Data

A discrete direct (DD) model calibration and uncertainty propagation approach is explained and demonstrated on a 4-parameter Johnson-Cook (J-C) strain-rate dependent material strength model for an aluminum alloy. The methodology's performance is characterized in many trials involving four random realizations of strain-rate dependent material-test data curves per trial, drawn from a large synthetic population. The J-C model is calibrated to particular combinations of the data curves to obtain calibration parameter sets which are then propagated to “Can Crush” structural model predictions to produce samples of predicted response variability. These are processed with appropriate sparse-sample uncertainty quantification (UQ) methods to estimate various statistics of response with an appropriate level of conservatism. This is tested on 16 output quantities (von Mises stresses and equivalent plastic strains) and it is shown that important statistics of the true variabilities of the 16 quantities are bounded with a high success rate that is reasonably predictable and controllable. The DD approach has several advantages over other calibration-UQ approaches like Bayesian inference for capturing and utilizing the information obtained from typically small numbers of replicate experiments in model calibration situations—especially when sparse replicate functional data are involved like force–displacement curves from material tests. The DD methodology is straightforward and efficient for calibration and propagation problems involving aleatory and epistemic uncertainties in calibration experiments, models, and procedures.

42 ENGINEERING↗

Analyzing the Calibration History of Radiometers for Determining Optimal Calibration Day(s)

This study investigates the effects of calibrating radiometers using one day or multiple cloudless days as recommended by ASTM and ISO standards. The results demonstrate good responsivity agreement with estimated uncertainty error bars over the years for various radiometers under various Broadband Outdoor Radiometer Calibration (BORCAL) events at both the National Renewable Energy Laboratory and the Southern Great Plains facility. The BORCAL method appears to justify the use of a single calibration day with enough data points to attain repeatable calibration results.

BORCAL↗

The LED calibration systems for the mDOM and D-Egg sensor modules of the IceCube Upgrade: Design, production, testing and use in module calibration

The IceCube Neutrino Observatory, instrumenting about 1 km 3 of deep, glacial ice at the geographic South Pole, is due to be enhanced with the IceCube Upgrade. The IceCube Upgrade, to be deployed during the 2025/26 Antarctic summer season, will consist of seven new strings of photosensors, densely embedded near the bottom center of the existing array. Aside from a world-leading sensitivity to neutrino oscillations, a primary goal is the improvement of the calibration of the optical properties of the instrumented ice. This calibration will be applied to the entire archive of IceCube data, improving the angular and energy resolution of the detected neutrino events. For this purpose, the Upgrade strings include a host of new calibration devices. Aside from dedicated calibration modules, several thousand LED flashers have been incorporated into the photosensor modules. We describe the design, production, and testing of these LED flashers before their integration into the sensor modules as well as the use of the LED flashers during lab testing of assembled sensor modules.

Analogue electronic circuits↗

Dark Energy Survey Year 3 results: Cosmology from cosmic shear and robustness to data calibration

This work, together with its companion paper, Secco, Samuroff et al., presents the Dark Energy Survey Year 3 cosmic shear measurements and cosmological constraints based on an analysis of over 100 million source galaxies. With the data spanning 4143 deg 2 on the sky, divided into four redshift bins, we produce the highest significance measurement of cosmic shear to date, with a signal-to-noise of 40. We conduct a blind analysis in the context of the ΛCDM model and find a 3% constraint of the clustering amplitude, S 8 ≡ σ 8 (Ω m /0.3) 0.5 = 0.759$^{+0.025}_{-0.023}$. A ΛCDM-Optimized analysis, which safely includes smaller scale information, yields a 2% precision measurement of S 8 = 0.772$^{+0.018}_{-0.017}$ that is consistent with the fiducial case. The two low-redshift measurements are statistically consistent with the Planck Cosmic Microwave Background result, however, both recovered S 8 values are lower than the high-redshift prediction by 2.3σ and 2.1σ (ρ-values of 0.02 and 0.05), respectively. The measurements are shown to be internally consistent across redshift bins, angular scales and correlation functions. The analysis is demonstrated to be robust to calibration systematics, with the S 8 posterior consistent when varying the choice of redshift calibration sample, the modeling of redshift uncertainty and methodology. Similarly, we find that the corrections included to account for the blending of galaxies shifts our best-fit S 8 by 0.5σ without incurring a substantial increase in uncertainty. We examine the limiting factors for the precision of the cosmological constraints and find observational systematics to be subdominant to the modeling of astrophysics. Specifically, we identify the uncertainties in modeling baryonic effects and intrinsic alignments as the limiting systematics.

79 ASTRONOMY AND ASTROPHYSICS↗

SNL will be able to provide well-calibrated models to weapons systems analysts by integrating an engine for constitutive model calibration with the GRANTA materials database

Researchers at Sandia National Laboratories have integrated the GRANTA materials database with the MatCal calibration engine to calibrate material models from characterization data. GRANTA is gaining acceptance across the NNSA Tri-lab complex and is being populated with weapons-specific test data by Sandia experimentalists. To use that data to create material models for use by weapons systems analysts, MatCal has been enabled import calibration data and test conditions from GRANTA to quickly and reproducibly produce a calibrated set of parameters for a given constitutive model. The team is currently working to store the parameters characterizing material behavior in GRANTA to make them accessible by all weapons analysts.

36 MATERIALS SCIENCE↗

NIR Dataset and Models (Near-Infrared Spectroscopy Calibration Dataset for Butanediol Fermentation and Multivariate Calibration Models) [SWR-22-60]

2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be used in a variety of chemical feedstocks, liquid fuels, and biosynthetic building blocks. While 2,3-BDO can be efficiently produced by fermentation, the fermentation requires continuous monitoring and control to maximize 2,3-BDO yields and minimize inhibitory coproducts. Because of the time required for sampling and at-line measurement of fermentation samples with high pressure liquid chromatography (HPLC), the ability for operators to perform real-time modification to fermentation conditions is limited. To overcome this challenge, researchers from the National Renewable Energy Laboratory (NREL) have developed a calibration model which can predict the concentration of several analytes in real-time using near-infrared (NIR) spectra of the filtered fermentation broth. While significantly reducing the need for off-line sampling, NREL expects this technology to play a critical role in maximizing 2,3-BDO production. 2,3-butanediol (2,3-BDO) is a useful chemical platform that can be used to create a variety of products. For instance, 2,3-BDO can be (1) dehydrated and converted into methyl ethyl ketone, a liquid fuel additive or (2) deoxydehydrated into 1,3-butadiene for synthetic rubber, which can also be oligomerized in high yields to gasoline, diesel, and jet fuel. In order to maximize 2,3-BDO production, frequent measurement of fermentation samples is needed, as small changes in oxygen concentration can drive the fermentation to undesired products. For example, oxygen-deficient conditions result in glycerol production, while excess oxygen concentrations result in acetoin production. This results in the need for measuring dissolved oxygen, glucose, and xylose concentrations in order to optimize the aeration rate of the fermentation. Traditional monitoring methods occurs off-line and can take up to 30 minutes per sample. With multiple fermenters and high-pressure liquid chromatography (HPLC) injectors, resulting in the need for multiple samples, the sampling process can take hours to complete. NREL’s calibration model can predict the glucose, xylose, 2,3-BDO, acetoin, and glycerol concentrations from NIR spectra of filtered fermentation liquor samples. Using a partial least-squares (PLS) calibration model, NREL’s model can monitor the concentration of these analytes during subsequent fermentations at bench- and pilot-scale, demonstrating the utility of NIR spectroscopy combined with chemometrics for real-time, at-line monitoring of 2,3-BDO fermentations.

Wolfrum, Edward↗

Increased accuracy and signal-to-noise ratio through recent improvements in infra-red video bolometer fabrication and calibration

The infra-red video bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of lines of sight within a large field of view. Recently validated in MAST-U [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)], it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB’s sensing element comprises a thin layer of high Z absorbing material, typically platinum, usually coated with carbon to reduce reflections [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)].Here, the possibility of using a relatively inert material such as titanium, is explored that can be produced in layers up to 1 μm compared to 2.5 μm for Pt and then coat it with Pt of the desired thickness (0.3 μm per side here) and carbon. This leads to a higher temperature signal (about 3 times) and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)]. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes [Mukai et al., Rev. Sci. Instrum. 87, 2014 (2016)].Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analyzing the temperature profile shape [Sano et al., Plasma and Fusion Res. 7, 2405039 (2012)] and [Mukai et al., Rev. Sci. Instrum. 89, 10E114 (2018)] or fitting the calculated laser power for different intensities and frequencies [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)]. Here, a simpler approach is presented, which relies on analyzing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.

Magnetic Fusion Energy↗

Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50

DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV=c 2 mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows us to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionization yield of electronic recoils down to ~180 eV er , exploiting 37 Ar and 39 Ar decays, and extrapolated to a few ionization electrons with the Thomas-Imel box model. Further, we present a model-dependent determination of the ionization response to nuclear recoils down to ~500 eV nr , the lowest ever achieved in liquid argon, using in situ neutron calibration sources and external datasets from neutron beam experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Feasibility study to use neutron capture for an ultralow energy nuclear-recoil calibration in liquid xenon

The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron source. Further, the measurement uses the recoil energies imparted to xenon nuclei during the de-excitation process following neutron capture, where promptly emitted γ cascades can provide the nuclei with up to 0.3 keV nr of recoil energy due to conservation of momentum. A successful calibration of scintillation photon and ionization electron yields below this energy will contribute to a greater sensitivity for liquid xenon experiments in searches for light WIMPs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy Reconstruction and Calibration of the MicroBooNE LArTPC

The Liquid Argon Time Projection Chamber (LArTPC) is increasingly becoming the chosen technology for current and future precision neutrino oscillation experiments due to its superior capability in particle tracking and energy calorimetry. In LArTPCs, calorimetric information is critical for particle identification, which is the foundation for the neutrino cross-section and oscillation measurements as well as searches for beyond standard model physics. One of the primary challenges in employing LArTPC technology is characterizing its performance and quantifying the associated systematic uncertainties. MicroBooNE, the longest operating LArTPC to date, has performed numerous such measurements, including studies of detector physics and electromagnetic shower reconstruction. Here we present results on the operation and performance of the detector during its data taking, highlighting accomplishments toward calorimetric reconstruction, calibration, and detector physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗