Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration approaches”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

XCal: model-based approach to X-ray CT spectral calibration

Transmission X-ray computed tomography (CT) is widely used to quantitatively reconstruct 3D objects composed of multiple materials. However, accurate CT reconstruction requires the system to be calibrated to account for the effective X-ray spectrum. Unfortunately, measurement of the effective spectrum is ill-posed, and existing calibration methods require that the system be recalibrated when the system parameters are changed. In this paper, we propose XCal, a multi-energy model-based spectral calibration approach for X-ray CT. The XCal approach models the effective spectrum using a separable physics-based model of the CT system. The model parameters are then estimated by fitting calibration data with known objects at multiple energies. An important advantage of XCal is that it allows the user to change scanner settings, such as the source voltage or X-ray filters, without the need for recalibration. Evaluations on simulated and measured datasets demonstrate that XCal significantly improves the accuracy of the estimated spectrum as compared to existing calibration methods.

Li, Wenrui [Purdue Univ., West Lafayette, IN (Unit↗

Differentiable Simulation of a Liquid Argon Time Projection Chamber

Liquid argon time projection chambers (LArTPCs) are widely used in particle detection for their tracking and calorimetric capabilities. The particle physics community actively builds and improves high-quality simulators for such detectors in order to develop physics analyses in a realistic setting. The ability of these simulators to mimic real, measured data is limited by the modeling of the physical detectors used for data collection. This modeling can be improved by performing dedicated calibration measurements. Conventional approaches calibrate individual detector parameters or processes one at a time. However, the impact of detector processes is entangled, making this a poor description of the underlying physics. We introduce a differentiable simulator that enables a gradient-based optimization, allowing for the first time a simultaneous calibration of all detector parameters. We describe the procedure of making a differentiable simulator, highlighting the challenges of retaining the physics quality of the standard, non-differentiable version while providing meaningful gradient information. We further discuss the advantages and drawbacks of using our differentiable simulator for calibration. Finally, we provide a starting point for extensions to our approach, including applications of the differentiable simulator to physics analysis pipelines.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bayesian calibration and uncertainty quantification of a rate-dependent cohesive zone model for polymer interfaces

In this work we present a rate-dependent cohesive zone model for the fracture of polymeric interfaces and performs a Bayesian calibration, an uncertainty quantification, and a sensitivity analysis for the model. The proposed cohesive zone model accounts for both reversible elastic and irreversible rate-dependent separation sliding deformation at the interface. The viscous dissipation due to the irreversible opening at the interface is modeled using elastic-viscoplastic kinematics that incorporates the effects of strain rate. Inverse calibration of parameters for such complex models through trial and error is challenging due to the large number of parameters of the model. Moreover, the calibrated parameter values are often non-unique and uncertain when the available experimental data is limited. To tackle this challenge, we employ a Bayesian calibration approach to identify parameters from experimental data, the resulting parameters significantly enhance the accuracy of the model. To quantify the uncertainty associated with the inverse parameter estimation, a modular Bayesian approach is employed to calibrate the unknown model parameters, accounting for the parameter uncertainty of the cohesive zone model. The advantages of the Bayesian calibration over a deterministic parameter fit are demonstrated. Further, to quantify the model uncertainties, such as incorrect assumptions or missing physics, a discrepancy function is introduced, which significantly improves the model’s prediction. Finally, the total uncertainty of the model is quantified in a predictive setting. A sensitivity analysis is performed to assess how changes in the input variables of the model affect the peak load, facilitating the identification of a concise set of highly influential parameters. The present approach can be used for calibration and uncertainty quantification for other complex computational mechanics models. It should also facilitate the designing of interface materials under uncertainty.

42 ENGINEERING↗

A visco-plastic constitutive model for accurate densification and shape predictions in powder metallurgy hot isostatic pressing

Powder metallurgy hot isostatic pressing (PM-HIP) is an advanced manufacturing process that produces near net shape parts with high material utilization and uniform microstructures. Despite being used frequently to produce small-scale components, the application of PM-HIP to large-scale components is limited due to inadequate understanding of its complex mechanisms that cause unpredictable post-HIP shape distortions. A computational model can provide necessary information about the intermediate and final stages of the HIP process that can help understand it better and make accurate predictions. Generally, two types of computational models are employed for PM-HIP of metal powders, namely, plastic and visco-plastic models. Between these, the plastic model is preferred due to its cheaper calibration approach requiring less experimental data. However, the plastic model sometimes produces incorrect predictions when slight variations of the HIP conditions are encountered in practical situations. Therefore, this work presents a visco-plastic model that addresses these limitations of the plastic model. A novel modified calibration approach is employed for the visco-plastic model that utilizes less experimental data than existing approaches. With the new approach, the data requirement is same for both plastic and visco-plastic models. This also enables a quantitative comparison of plastic and visco-plastic models, which have been only qualitatively compared in the past. When calibrated with the same experimental data, both the models are found to produce similar results. In conclusion, the calibrated visco-plastic model is applied to several complex geometries, and the predictions are found to be in good agreement with experimental observations.

Hot isostatic pressing↗

Laboratory and field assessment of mid-infrared absorption (MIRA) instrument performance for methane and ethane dry mole fractions

Concurrent measurements of methane (CH 4 ) and ethane (C 2 H 6 ) can be used to identify and separate methane sources, as ethane is present in thermogenic sources (e.g., oil and natural gas) but not in biogenic sources (e.g., agriculture). In this study, we evaluated the performance of multiple Aeris MIRA Ultra instruments (Versions 1 and 2) through controlled laboratory tests and tower-based deployments under field conditions. The systems were modified with an external pump, flow control, a Nafion dryer, and a custom-built auxiliary box to automate the system and transmit near real-time data. We determined the best calibration approach for our application, given practical limitations, to be a full calibration cycle (with ambient and high calibration cylinders) about once per day and an ambient calibration cylinder sampled hourly. Measurement uncertainty was assessed, including the uncertainty due to instrument noise as a function of calibration frequency, uncertainty in the water vapor correction, and cylinder assignment uncertainty. Instrument noise was the dominant source of uncertainty for C 2 H 6 , while the water vapor correction dominated the CH 4 uncertainty. For Version 2 systems with hourly calibrations and a Nafion dryer with counterflow, the mean total uncertainty, including both systematic errors and noise, of hourly averages was 0.8–3.0 ppb CH 4 and 0.35–0.37 ppb C 2 H 6 . Laboratory intercomparisons showed network compatibility within 1.2 ppb CH 4 and 0.23 ppb C 2 H6, and a collocated deployment with a NOAA Picarro system agreed within 1.8 ppb CH 4 . Instrument noise varied substantially amongst the instruments, with errors reaching up to 11 ppb CH 4 and 2 ppb C 2 H 6 for hourly means, with similar variability indicated in a 50 h cylinder test. With appropriate engineering and calibration, the Aeris MIRA Ultra has the potential to distinguish regional methane emission sources in many field settings.

03 NATURAL GAS↗

Extremely Low Energy Nuclear Recoil Calibrations for Dark Matter Direct Detection (Final Technical Report)

This project developed and demonstrated a new calibration approach for low-energy nuclear recoils in solid-state detectors based on neutron capture. Precise calibration in the sub-keV regime is a critical challenge across the HEP portfolio. Existing measurements show deviations and inconsistencies across methods. Neutron capture provides a complementary approach producing discrete recoils via γ cascades.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Automatic Calibration and Health Monitoring of Infrastructure Sensors

Smart transportation infrastructure relies on networks of heterogeneous sensors - cameras, radars, and lidars - continuously monitoring traffic conditions. However, executing the initial spatial calibration of multiple sensors and the subsequent health monitoring presents significant operational challenges. Environmental factors, mechanical vibrations, and gradual drift cause spatial misalignment, degrading fusion performance and tracking accuracy. Traditional calibration approaches require manual intervention with specialized targets or survey equipment, resulting in service interruptions and high maintenance costs. This work presents an automated framework for initial calibration and continuous health monitoring without human intervention or service disruption. Our approach addresses two critical problems: (1) detecting when sensors become miscalibrated during operation, and (2) automatically re-establishing spatial alignment using only operational traffic data. The health monitoring component analyzes measurement innovations - differences between sensor observations and predicted object states - to detect systematic biases indicative of calibration drift. By computing bias magnitude, directional consistency, and rejection rates, the system identifies miscalibrations as small as 0.5 meters. Unlike traditional methods requiring known calibration targets, our diagnostic operates continuously on live traffic observations, enabling early detection before fusion quality degrades. The automatic recalibration algorithm leverages overlapping sensor fields-of-view and temporal correlation of vehicle observations. Using graph-based optimization, the system automatically discovers which sensor pairs observe common regions, estimates pairwise spatial transformations using RANSAC-based robust estimation, and jointly optimizes all sensor poses through bundle adjustment. The framework handles practical deployment challenges, including different sensor sampling rates (1-10 Hz), varying installation positions, unknown orientations, and limited overlap regions (>10%). When approximate sensor positions are available from installation surveys (+/-1m accuracy), the algorithm additionally estimates sensor orientations, refining both position and rotation to sub-meter and sub-degree accuracy. We validate the framework on multi-hour traffic datasets from six heterogeneous sensors with sampling rates ranging from 1 Hz to 10 Hz. Results demonstrate successful calibration even with sparse overlap (<20%) and automatic detection of miscalibrations exceeding 0.8 meters. This work enables a "deploy-and-forget" sensor infrastructure that maintains calibration autonomously, reducing maintenance costs while improving tracking accuracy. The techniques generalize beyond transportation to any multi-sensor monitoring application requiring robust spatial alignment, including smart cities, industrial monitoring, and surveillance systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Enhancing Automotive Intrusion Detection Through Multi-Modal Fusion: A CAN FD-LiDAR Approach

As vehicles become smarter and more autonomous, they increasingly depend on advanced sensors and communication technologies to operate securely. However, such growing dependence on technology—whether it’s CAN (Controller Area Network) for internal communication or LiDAR (Light Detection and Ranging) for sensing the world around them—also expands the attack surface for the types of cyber attacks. Traditional intrusion detection systems (IDS) typically monitor these systems in isolation, limiting their ability to detect sophisticated, crosssystem attacks. To address this, we propose a multi-modal fusion approach that combines real-world CAN FD signals (from the HCRL dataset) with LiDAR features (from the nuScenes dataset) to enhance attack detection. Our method employs a twostage ensemble approach. Calibrated XGBoost and LightGBM models initially process CAN FD (Fuzzing Data) and LiDAR data independently, detecting timing anomalies and space abnormalities. They are subsequently logarithmically combined with a logistic regression meta-model along with 17 engineered features capturing cross-modal behavior, prediction conflicts, and nonlinear interactions. This approach achieves an AUC of 0.87 and an F1-score of 0.82, surpassing single-modality baselines and early fusion methods, at merely 2 ms inference latency. Compared with deep learning competitors, it is 3 times more efficient, providing a lightweight, interpretable, and real time solution to automotive cybersecurity.

97 MATHEMATICS AND COMPUTING↗

Quench process modeling & simulation in the heat-treatment of critical aerospace components

To manufacture light-weight, advanced metal alloy components for gas turbine engines, quench heat-treatment processes are typically used. By quenching the component from elevated temperatures, the alloy sometimes undergoes a solid-state phase transformation which produces special microstructures with the required, enhanced mechanical properties. However, the quenching can also lead to cracks forming in the component. Addressing the quench cracking problems adds a significant burden to the cost, schedule, and energy demand of manufacture. Currently, optimizing the quench process to mitigate or avoid the cracking is performed largely by trial-and-error, relying heavily on costly experimental (thermocouple)trials to understand the local thermal gradients which cause the cracks to form. In this first part (Phase 1) of the work, high-performance computing is employed to establish the ability of modern CFD (computational fluid dynamics) to alleviate or wholly replace the experimental quenching trials by virtual testing. A Baseline CFD model is defined and its accuracy established to be comparable to(and which usually exceeds) the accuracy of existing HTC (heat-transfer coefficient) based simulation methods of quenching. As a first-principles based approach, “calibration” of the Baseline CFD model is independent of the quench process itself, but instead relies on the accuracy of the underlying (modeled),generic two-phase fluid processes which cannot be currently resolved by CFD for large, industrial-scale cases. A novel, high-fidelity DNS capability has been developed and verified to examine and further improve upon the mean-field closure submodels on which the Baseline CFD approach is based.1

99 GENERAL AND MISCELLANEOUS↗

Quench process modeling & simulation in the heat-treatment of critical aerospace components

To manufacture light-weight, advanced metal alloy components for gas turbine engines, quench heat-treatment processes are typically used. By quenching the component from elevated tempera-tures, the alloy sometimes undergoes a solid-state phase transformation which produces special microstructures with the required, enhanced mechanical properties. However, the quenching can also lead to cracks forming in the component. Addressing the quench cracking problems adds a significant burden to the cost, schedule, and energy demand of manufacture. Currently, optimizing the quench process to mitigate or avoid the cracking is performed largely by trial-and-error, relying heavily on costly experimental (thermocouple) trials to understand the local thermal gradients which cause the cracks to form. In this first part (Phase 1) of the work, high-performance computing is employed to establish the ability of modern CFD (computational fluid dynamics) to alleviate or wholly replace the experimental quenching trials by virtual testing. A baseline CFD model is defined and its accuracy established to be comparable to (and which usually exceeds) the accuracy of existing HTC (heat-transfer correlation) based simulation methods of quenching. As a first-principles based approach, “calibration” of the Baseline CFD model is independent of the quench process itself, but instead relies on the accuracy of the underlying (modeled), generic two-phase fluid processes which cannot be currently resolved by CFD for large, industrial-scale cases. A novel, high-fidelity DNS capability has been developed and verified to examine and further improve upon the mean-field closure submodels on which the Baseline CFD approach is based.

36 MATERIALS SCIENCE↗

Constraints on f ( R ) gravity from thermal-Sunyaev-Zel’dovich-effect-selected SPT galaxy clusters and weak lensing mass calibration from DES and HST

We present constraints on the f ( R ) gravity model using a sample of 1005 galaxy clusters in the redshift range 0.25–1.78 that have been selected through the thermal Sunyaev-Zel’dovich effect from South Pole Telescope data and subjected to optical and near-infrared confirmation with the multicomponent matched filter algorithm. We employ weak gravitational lensing mass calibration from the Dark Energy Survey Year 3 data for 688 clusters at z < 0.95 and from the Hubble Space Telescope for 39 clusters with 0.6 < z < 1.7 . Our cluster sample is a powerful probe of f ( R ) gravity, because this model predicts a scale-dependent enhancement in the growth of structure, which impacts the halo mass function (HMF) at cluster mass scales. To account for these modified gravity effects on the HMF, our analysis employs a semianalytical approach calibrated with numerical simulations. Combining calibrated cluster counts with primary cosmic microwave background temperature and polarization anisotropy measurements from the Planck 2018 release, we derive robust constraints on the f ( R ) parameter f R 0 . Our results, log 10 | f R 0 | < − 5.32 at the 95% credible level, are the tightest current constraints on f ( R ) gravity from cosmological scales. This upper limit rules out f ( R ) -like deviations from general relativity that result in more than a ∼ 20 % enhancement of the cluster population on mass scales M 200 c > 3 × 10 14 M ⊙ . Published by the American Physical Society 2025

79 ASTRONOMY AND ASTROPHYSICS↗

Autocalibration of the E3SM Version 2 Atmosphere Model Using a PCA-Based Surrogate for Spatial Fields

Global Climate Model tuning (calibration) is a tedious and time-consuming process, with high-dimensional input and output fields. Experts typically tune by iteratively running climate simulations with hand-picked values of tuning parameters. Many, in both the statistical and climate literature, have proposed alternative calibration methods, but most are impractical or difficult to implement. We present a practical, robust, and rigorous calibration approach on the atmosphere-only model of the Department of Energy's Energy Exascale Earth System Model (E3SM) version 2. Our approach can be summarized into two main parts: (a) the training of a surrogate that predicts E3SM output in a fraction of the time compared to running E3SM, and (b) gradient-based parameter optimization. To train the surrogate, we generate a set of designed ensemble runs that span our input parameter space and use polynomial chaos expansions on a reduced output space to fit the E3SM output. We use this surrogate in an optimization scheme to identify values of the input parameters for which our model best matches gridded spatial fields of climate observations. To validate our choice of parameters, we run E3SMv2 with the optimal parameter values and compare prediction results to expertly-tuned simulations across 45 different output fields. This flexible, robust, and automated approach is straightforward to implement, and we demonstrate that the resulting model output matches present day climate observations as well or better than the corresponding output from expert tuned parameter values, while considering high-dimensional output and operating in a fraction of the time.

54 ENVIRONMENTAL SCIENCES↗

Determination of electron-hole pair creation energy in Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 quaternary semiconductor for room-temperature gamma-ray detection

We report the first-time measurement of the electron-hole pair (ehp) creation energy (W ehp ) in novel Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 (CZTS) quaternary semiconductor. CZTS in single crystalline form is poised to be the future of large-volume room-temperature gamma-ray detectors due to its excellent compositional homogeneity with highly reduced defects, high-Z (atomic number) constituents, wide bandgap (1.6 eV), and superior charge transport properties. Despite a great deal of study of the material and device properties since its inception, the W ehp in CZTS has not been measured experimentally. Accurate determination of W ehp is essential for calibration of the spectrometer and other theoretical calculations. In this study we have used an absolute calibration approach, which is based on an iterative approach that yields the Wehp as the best-fit parameter. Using a 241 Am alpha emitting radioisotope and a planar CZTS detector, the Wehp in CZTS was calculated to be 4.47 eV. The obtained value has been validated by accurately predicting the peak energy for gamma rays emitted by a 137 Cs source and read by a CZTS detector with different dimensions. The dependences of the calculated W ehp value on the detector dimensions, type of interaction, and effect of charge trapping are also discussed.

42 ENGINEERING↗

CoLoRe-2LPT: Lyman-$α$ mock catalogues for the validation of DESI cosmological analyses

The Lyman-$α$ (Ly$α$) forest has become a crucial probe for studying the large-scale structure of the universe at high redshift ($z > 2$), providing powerful constraints on Baryon Acoustic Oscillations (BAO) and the full-shape (FS) clustering of matter. As a key ingredient for upcoming BAO and FS analyses, we present a new generation of fast cosmological Ly$α$ mocks based on second-order Lagrangian perturbation theory (2LPT). These new mocks significantly improve upon previous log-normal approaches, both at accurately capturing small scale clustering and at recovering the non-linear broadening of the BAO peak. They are able to reproduce Ly$α$ statistics within $10\%$ of the latest DESI measurement; including the Ly$α$ bias and the redshift-space distortion $β$ parameter, mean transmitted flux, and 1D power spectrum. The corresponding quasar (QSO) clustering is also improved with respect to previous approaches, calibrated against high-resolution Abacus simulations, recovering the observational QSO linear bias to less than $5\%$ and improving redshift-space distortions via 2LPT velocities and the addition of Fingers-of-God effects. Furthermore, these mocks incorporate high column density systems and metal lines, allowing us to explore the effects and systematics induced by these astrophysical contaminants. This new set of mocks has been key for enhancing the modeling and validation of the DESI DR2 Ly$α$ full shape cosmological analysis. This work provides a physically motivated and computationally efficient tool for simulating current and next-generation Ly$α$ surveys and validating FS and BAO analysis.

Bernal, M.F. Ruiz-Herrera [Madrid, CIEMAT] (ORCID:↗

Spatiotemporal Automatic Calibration of Infrastructure Lidar, Radar, and Camera with a Global Navigation Satellite System

Robust and accurate perception is important for modern intelligent transportation systems (ITS), which use sensors of various modalities for data fusion to create a digital twin of an intersection. Sensor calibration is an important process that creates a unified coordinate frame for the sensor output data so that it can be used for data fusion. Classical approaches for sensor calibration are time-consuming, require an overlapping field of view for feature matching, and are not feasible for ITS application as they cause disruptions in the flow of traffic. In this paper, we present a spatiotemporal automatic calibration approach to calibrate multiple infrastructure lidar, radar, and cameras installed at a traffic intersection. The approach uses global navigation satellite system (GNSS) positioning information shared by connected vehicles, and when the vehicle is detected by the sensor, we match the sensor detections with the GNSS coordinates. The proposed algorithm is evaluated with a real-world dataset utilizing detections from two radars, cameras, and lidars with a test vehicle instrumented with a post-processing kinematic (PPK)-corrected GNSS driving past the sensors installed at a four-way traffic intersection. The experimental results show that the proposed automatic calibration approach can achieve the transformation with a root mean squared error of less than 0.5 for radar and lidar and less than 2 for camera detections. The ability to rapidly calibrate sensors not only benefits initial installations, but can also be used for system health monitoring, while utilizing available connected vehicle data to test the real-time sensor fidelity and operational status.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗