Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino, Rafael [Unlisted]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

py4DSTEM: A Software Package for Four-Dimensional Scanning Transmission Electron Microscopy Data Analysis

Scanning transmission electron microscopy (STEM) allows for imaging, diffraction, and spectroscopy of materials on length scales ranging from microns to atoms. By using a high-speed, direct electron detector, it is now possible to record a full two-dimensional (2D) image of the diffracted electron beam at each probe position, typically a 2D grid of probe positions. These 4D-STEM datasets are rich in information, including signatures of the local structure, orientation, deformation, electromagnetic fields, and other sample-dependent properties. However, extracting this information requires complex analysis pipelines that include data wrangling, calibration, analysis, and visualization, all while maintaining robustness against imaging distortions and artifacts. In this paper, we present py4DSTEM, an analysis toolkit for measuring material properties from 4D-STEM datasets, written in the Python language and released with an open-source license. We describe the algorithmic steps for dataset calibration and various 4D-STEM property measurements in detail and present results from several experimental datasets. We also implement a simple and universal file format appropriate for electron microscopy data in py4DSTEM, which uses the open-source HDF5 standard. We hope this tool will benefit the research community and help improve the standards for data and computational methods in electron microscopy, and we invite the community to contribute to this ongoing project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AMS / BARC Joint Survey Addendum Technical Report

This report details the data analysis results from data collected during the September-October 2019 joint survey series between the Department of Energy (DOE) National Nuclear Security Administration (NNSA) Aerial Measuring System (AMS) asset, and the Government of India’s Department of Atomic Energy (DAE) Bhabha Atomic Research Centre (BARC). This joint survey series took place at the Nevada National Security Site (NNSS), areas of public land in Southern Nevada, and at the DOE Office of Legacy Management (LM) Large Area Calibration Pads (LACP) at the Grand Junction Regional Airport in Grand Junction, CO. The data detailed in this report were gathered at the LACP. More details regarding the setup of these surveys and personnel involvement can be found in the AMS / BARC Joint Survey Summary Report. The data from the LACP collected by AMS are consistent with past data collection campaigns at the LACP. The AMS Bell 412 (B412) helicopter, equipped with both the standard AMS thallium-doped sodium iodide (NaI(Tl)) 2"x4"x16" 12-detector system and a subset of the BARC Aerial Gamma Spectroscopy System (AGSS) consisting of two independent 3"x3"cylindrical NaI(Tl) detectors, measured each of the five calibration pads for a minimum of 10 minutes. After the helicopter measurements, a pressurized ion chamber (PIC) was used to directly measure radiation exposure rates on each of the pads for a period 5 minutes. The geophysical calibration procedure published by the International Atomic Energy Agency (IAEA) (Erdi-Krausz et al. 2003) was used to determine the spectral stripping sensitivity matrix for naturally occurring radiological material (NORM). The sensitivity matrix is consistent with the AMS long term average. Additionally, the PIC data was used to calibrate the AMS system for exposure rate. The results of the exposure rate analysis are also consistent with AMS long-term averages.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Weak lensing of Type Ia Supernovae from the Dark Energy Survey

ABSTRACT We consider the effects of weak gravitational lensing on observations of 196 spectroscopically confirmed Type Ia Supernovae (SNe Ia) from years 1 to 3 of the Dark Energy Survey (DES). We simultaneously measure both the angular correlation function and the non-Gaussian skewness caused by weak lensing. This approach has the advantage of being insensitive to the intrinsic dispersion of SNe Ia magnitudes. We model the amplitude of both effects as a function of σ8, and find σ8 =1.2$^{+0.9}_{-0.8}$. We also apply our method to a subsample of 488 SNe from the Joint Light-curve Analysis (JLA; chosen to match the redshift range we use for this work), and find σ8 =0.8$^{+1.1}_{-0.7}$. The comparable uncertainty in σ8 between DES–SN and the larger number of SNe from JLA highlights the benefits of homogeneity of the DES–SN sample, and improvements in the calibration and data analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Small-angle X-ray and neutron scattering

Small-angle scattering (SAS) is a technique that is able to probe the structural organization of matter and quantify its response to changes in external conditions. X-ray and neutron scattering profiles measured from bulk materials or materials deposited at surfaces arise from nanostructural inhomogeneities of electron or nuclear density. Furthermore, the analysis of SAS data from coherent scattering events provides information about the length scale distributions of material components. Samples for SAS studies may be prepared in situ or under near-native conditions and the measurements performed at various temperatures, pressures, flows, shears or stresses, and in a time-resolved fashion. In this Primer, we provide an overview of SAS, summarizing the types of instrument used, approaches for data collection and calibration, available data analysis methods, structural information that can be obtained using the method, and data depositories, standards and formats. Recent applications of SAS in structural biology and the soft-matter and hard-matter sciences are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diagnostics of plasma–liquids systems: Challenges and their mitigation

This article will review two popular methods of laser diagnostics in a plasma–liquid system and generally in low-temperature plasmas. These are Thomson scattering and laser-induced fluorescence. Setting up the plasma–liquid interaction experiment will be described while stressing the important points for laser diagnostics and maintaining conditions for correct and repeatable measurements. In this work, I will discuss the caveats that are encountered when measuring an inherently unstable and collisional system, such as plasma interacting with the liquid and how these challenges impact that data analysis and calibration efforts for these two-diagnostic approaches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New high precision measurements of the cosmic charged particle rate beyond the Arctic Circle with the PolarquEEEst experiment

The goal of the PolarquEEEst experiment was to measure the cosmic charged particle rate at latitudes greater than 66° N, where no systematic and accurate measurements at sea level have ever been performed. A latitude range well above the Arctic Circle was explored on board of a sailboat, up to the unprecedented northernmost value of 82°07' N. In this paper a description of the experimental set-up is reported, then the procedures for calibration and data analysis are described in detail. The results show that the rate measured in this latitude range stays constant within a novel accuracy of ±1%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Gigaparsec-scale Hydrodynamic Volume Reconstructed with Deep Learning

The next generation of spectroscopic surveys will map the large-scale structure of the Universe at high redshifts (2 ≤ z ≤ 5) using millions of quasar spectra, enabling major advances in constraining both the standard cosmological model and its extensions. Robust cosmological analyses of these data sets require numerical simulations that both cover gigaparsec volumes and resolve features on ∼10 kpc scales and smaller. However, running such large-volume, high-resolution hydrodynamic simulations is computationally prohibitive. We present a generative deep learning model that enhances a low-resolution, gigaparsec-scale (960 h −1 Mpc) hydrodynamic simulation using a smaller (80 h −1 Mpc) high-resolution input hydrodynamic simulation as training data. The resulting enhanced simulation reproduces the line-of-sight power spectrum to within ∼10% and the three-dimensional power spectrum at the ∼20% level at intermediate to small scales (k ≲ 2 h Mpc −1 ). Our method shows strong promise for producing realistic simulations for cosmological analyses with current surveys such as the Dark Energy Spectroscopic Instrument and upcoming next-generation experiments, but further improvements are needed to accurately recover the large-scale modes. We publicly release the enhanced hydrodynamic simulation, along with a halo catalog from a companion N-body dark matter simulation to support the calibration of data analysis pipelines for these large-scale surveys.

Convolutional neural networks↗

Analysis of Long-Term Quality Control Data for a 137 Cs Dosimetry Calibration Source

Strict quality assurance programs are required for many radiological applications, but these seldom exist for verifying dosimetry calibration sources. After initial characterization of a dosimetry calibration facility, quality control procedures are recommended to ensure the early detection of any changes or malfunctions. These also result in refined knowledge about average dose rate and experimental variations in dose delivery. This paper describes the implementation of a phase I quality control protocol for a 137 Cs dosimetry calibration source and includes an analysis of the resulting data collected over a 24-mo period. During this time, substantial data was collected to establish trial control limits. Air kerma rate measurements were obtained using an ion chamber and were adjusted for decay, corrected for ambient temperature, pressure and humidity, and then analyzed using quality control charts. Three variations of rational subgrouping methods were used in order to find assignable causes of error, and Nelson's Rules were followed to detect any non-random statistical variations. Measurements were subgrouped according to same-day measurements in order to detect positional errors as well as atmospheric correction errors. Additionally, measurements were subgrouped according to analogous experimental setups in order to detect failure in equipment or incorrect settings. Both were analyzed using the X-bar and R chart method. Similarly, individuals and moving ranges charts were used to carefully examine each position in order to observe any situational errors that may occur which include timing, positional, or interference errors. Each method was successful in identifying unique out-of-control data points that occurred during the phase I application of forming control limits. Furthermore, over the 24-mo period, enough data points were deemed in-control to establish reliable trial limits. Future experiments will include the phase II application of gaining more reliable measurements in order to fine-tune the limits, as well as performing a designed experiment, where variables are purposefully changed in order to test the variation of the data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimizing ICEBERG LArTPC Run Configuration for Data Collection

To ensure accurate data collection and diagnostics of the ICEBERG electronics, charge injection runs were completed using a pulser to mimic known charge deposition amounts on the LArTPC wires and collect data for analysis and calibration. This analysis is essential for optimizing the detector's performance by identifying the optimal range of DAC values that avoid saturation zones and provide the best experimental results for non-pulser runs.

Ganguly, Neil↗

10 Boron-film-based gas detectors at ESS

The development of detectors for the European Spallation Source is an important parallel element to the effort put into the design and construction of the neutron source and instruments. The 10Boron-film-based detector developments that started over a decade ago as basic detector concepts have now reached technical maturity after intense prototyping work and numerous testing campaigns. Several of the ESS beamlines that will soon enter the commissioning phase started welcoming the detector systems built with the 10 B-film converter technology. The real-size demonstrators evolved in the last 2–3 years into a diverse suite of gas proportional counters for use in diffraction, reflectometry and small-angle scattering studies in spite of the operational complexity posed by the requirements for large-area coverage, low material budget and robustness for operation in the high-flux and high-radiation environment of ESS. The detectors are now being shipped to ESS or undergoing the last performance and calibration tests before being handed over to the instrument teams for installation in the host beamlines. A common feature of these detector systems is the very large number of readout channels that they are instrumented with in order to fulfill the demanding requirements for sensitivity, spatial resolution and count-rate capability. Across all of the detector types that will operate at ESS, the integration, testing and commissioning of the read-out technologies and software tools for data reduction, calibration and analysis are the focus of the detector and integration teams. These will yield a wealth of knowledge about their operation as well as initial results on the in-situ performance, a very important asset to ensure rapid commissioning of the detectors when neutrons from the ESS source become available. In this paper we will give an overview of the 10 B-film-based detector technologies included in the ESS detector suite that are currently facing the transition from the production phase to installation and integration with the other beamline components, which comes with its own specific challenges of both organizational and technical nature.

47 OTHER INSTRUMENTATION↗