Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration free laser induced breakdown spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Neptunium transition probabilities estimated through laser induced breakdown spectroscopy (LIBS) measurements

in tis report calibration free–laser induced breakdown spectroscopy (CF-LIBS) approaches are promising for the analysis of radioactive materials; however, a lack of reported fundamental properties for these materials is an obstacle to implementation. Spectra of laser induced plasmas containing Np and Sr, along with Saha–Boltzmann methods, were used to estimate the first reported transition probabilities (TPs) of Np. These TPs enabled the first attempt at CF-LIBS analysis of radioactive samples to predict Np/Sr ratios with a mean error of 3.86%. The presented methodology of TP estimation will be applied to the study of other actinides and allow broader applications of CF-15 LIBS in the nuclear field.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of Laser-Induced Breakdown Spectroscopy for the Californium-252 Supply Program

Calibration-free–laser-induced breakdown spectroscopy (CF-LIBS) is suggested as an alternative to traditional LIBS because it does not rely on calibration curves and instead relies on previously reported parameters called transition probabilities. Transition probabilities are fundamental parameters that describe the probability a specific transition from an upper energy to a lower energy will occur. These values act as internal calibrations and allow concentrations to be calculated based on the plasma temperature and electron density, which can be determined from Saha-Boltzmann methods. CF-LIBS provides the ability to perform elemental concentration estimations on samples without the need for chemical dilutions and only nanograms of material are ablated into the plasma. These benefits can be applied remotely inside hot cells, glove boxes, and radiation hoods through optical fibers. This report summarizes recent efforts to develop CF-LIBS methods for future applications within Oak Ridge National Laboratory’s radioisotope production portfolio, such as the Cf-252 Supply Program. Summaries are provided for the developed Python scripts for data analysis and two studies employing these programs to determine unreported transition probabilities of relevant lanthanides. Additionally, a review of fiber-delivered LIBS and a discussion of a LIBS fiber probe design are provided.

07 ISOTOPE AND RADIATION SOURCES↗

Radiative transition probabilities of neutral and singly ionized rare earth elements (La, Ce, Pr, Nd, Sm, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu) estimated by laser-induced breakdown spectroscopy

Rare earth elements (REEs) are essential to society given their prevalence in many modern technologies. Quantitative elemental analysis of REEs is therefore a critical capability. Calibration free–laser-induced breakdown spectroscopy (CF-LIBS) is a rapidly maturing and promising approach to quantitative elemental analysis with many attractive qualities. The application of CF-LIBS to analyzing samples containing the REEs is hindered by a lack of fundamental data, specifically transition probabilities (TPs). As such, this study seeks to help address this knowledge deficiency by reporting 967 previously unreported TPs for 13 REEs (lanthanum, cerium, praseodymium, neodymium, samarium, gadolinium, terbium, dysprosium, holmium, erbium, thulium, ytterbium, and lutetium). The method developed in this study to estimate the TPs requires small amounts of material (a few nanograms) compared with other approaches (~ milligrams), uses non-specialized equipment, and does not involve complicated sample preparations.

(LIBS)↗

Calibration-Free Quantitative Analysis of Lithium-Ion Battery (LiB) Electrode Materials Using Laser-Induced Breakdown Spectroscopy (LIBS)

Recent years have seen a surge in the demand for high-performance battery electrode materials for automotive and various electronic device applications. Improving battery performance requires precise knowledge of the structure–composition properties of active electrode materials. To this effect, quantitative and precise estimation of the composition of advanced electrode materials, containing trace amounts of dopants, provide immense value toward developing next-generation high-capacity battery materials. Herein, we demonstrate the application of calibration-free laser-induced breakdown spectroscopy (LIBS) as a powerful analytical tool for rapid and reliable quantitative spectrochemical characterizations of layered Li metal oxide cathodes containing Mo and Cr dopants (<5 atom %). Specifically, we employ the LIBS using an internal calibration methodology to establish the quantitative elemental ratios of major (Ni, Mn, Co) and trace dopant (Cr, Mo) transition metals to bulk Li contents in diverse cathode material samples such as LiNi 0.5 Mn 0.5 O 2 (NM-50/50), LiNi 0.33 Mn 0.33 Co 0.33 O 2 (NMC), LiNi 0.317 Mn 0.317 Co 0.317 Cr 0.05 O 2 (Cr-doped NMC), and LiNi 0.5– x /2 Mn 0.5– x /2 Mo x O 2 ( x = 0.03, 0.04, 0.05) (Mo-doped NM-50/50) that were synthesized via sol–gel routes. The LIBS-estimated elemental compositions are in good agreement with the nominal stoichiometric values. Furthermore, ex situ LIBS characterizations presented here pave the path for future high-efficacy application of calibration-free quantitative LIBS for rapid in situ analyses of elemental composition changes in battery electrode materials under operation that need not resort to off-site analytical techniques requiring cumbersome sample preparations and/or external standards.

25 ENERGY STORAGE↗

Radiative transition probabilities of neutral and singly ionized Europium estimated by laser-induced breakdown spectroscopy (LIBS)

Laser-induced breakdown spectroscopy (LIBS) is a versatile technique for compositional analysis for solids, liquids, or gasses. LIBS is an asset for the quantitative or qualitative analysis of resource limited materials like actinides and rare earths because it is quasi-nondestructive. Two Eu 2 O 3 pellets were synthesized to be a test and validation set, respectively. Spectral lines identified from the National Institute of Standards and Technology database with fundamental data reported were used to form Saha-Boltzmann plots. The Saha-Boltzmann plots were used to determine the plasma temperatures and electron densities of the laser-induced plasmas for both samples. These Saha-Boltzmann plots were then used to calculate previously unreported transition probabilities associated with identified peaks. Additionally, the transition probabilities presented in this paper provide the capability for calibration free LIBS to be performed more readily on europium samples and the spectroscopic analysis of stellar bodies. Eight previously unreported transition probabilities are presented in this paper; five for Eu I and three for Eu II. The transition probabilities for Eu I ranged from 0.172 to 7.38 × 10 7 s -1 and those for Eu II ranged from 1.56 to 6.75 × 10 7 s -1 .

47 OTHER INSTRUMENTATION↗

Hydrogen isotope analysis in W-tiles using fs-LIBS

Abstract Laser-Induced Breakdown Spectroscopy (LIBS) is a promising technology for in-situ analysis of Plasma-Facing Components in magnetic confinement fusion facilities. It is of major interest to monitor the hydrogen isotope retention i.e. tritium and deuterium over many operation hours to guarantee safety and availability of the future reactor. In our studies we use ultraviolet femtosecond laser pulses to analyze tungsten (W) tiles that were exposed to a deuterium plasma in the linear plasma device PSI-2, which mimics conditions at the first wall. A high-resolution spectrometer is used to detect the Balmer- $$\alpha$$ α transition of the surface from implanted hydrogen isotopes (H and D). We use Calibration Free CF-LIBS to quantify the amount of deuterium stored in W. This proof-of-principle study shows the applicability of femtosecond lasers for the detection of low deuterium concentration as present in first wall material of prevailing fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Updates of the KArLE Experiment: New Libs Calibration Under High Vacuum for the Quantification of Potassium in Basalt for In Situ Geochronology

In planetary exploration, in situ absolute geochronology is one of the main important measurements that needs to be accomplished. Until now, on Mars, the age of the surface is only determined by crater density counting, which gives relative ages. These ages can have a lot of uncertainty as they depend on many parameters. More than that, the curves must be ties to absolute ages. Thus far, only the lost lander Beagle 2 was designed to conduct absolute geochronology measurements, though some recent attempts using MSL Curiosity show that this investigation is feasible and should be strongly encouraged for future flight. Experimental: The Potassium (K)-Argon Laser Experiment (KArLE) is being developed at MSFC through the NASA Planetary Instrument Definition and Development Program (PIDDP). The goal of this experiment is to provide in situ geochronology based on the K-Ar method. A laser ablates a rock under high vacuum, creating a plasma which is sensed by an optical spectrometer to do Laser Induced Breakdown Spectroscopy (LIBS). The ablated material frees gases, including radiogenic 40Ar,which is measured by a mass spectrometer (MS). As the potassium is a content and the 40Ar is a quantity, the ablated mass needed in order to relate them. The mass is given by the product of the ablated volume by the density of this material. So we determine the mineralogy of the ablated material with the LIBS spectra and images and calculate its density. The volume of the pit is measured by using microscopy. LIBS measurement of K under high vacuum: Three independant projects [1, 2, 3] including KArLE, are developing geochronological instruments based on this LA-LIBS-MS method. Despite several differences in their setup, all of them have validated the methods with analyses and ages. However, they all described difficulties with the LIBS measurements of K [3,4]. At ambient pressure, the quantification of K by LIBS on geological materials can be accurate [5]. However the protocol of the LA-LIBS-MS experiment required hundreds of shots under high vacuum in order to free enough 40Ar* to be measured by the QMS. This long duration of ablation may induces significant changes in the LIBS spectra. The pressure may increases by orders of magnitudewithin the chamber and the laser pit geometry can change the effectiveness of ablation and intensity of plasma light received. These effects introduce variation between the first and last spectra and so the quantification of K is more complex. The ablation of one crater can give, depending on the protocol of acquisition, from tens to hundreds of spectra. Protocol and results: We are in the process of further characterizing the variation introduced into LIBS spectra by the use of hundreds of laser shots, and definining a protocol that can be used to ensure accuracy and reporoducibility in the results.We are using natural rock powder standards fused in a furnace, as well as mars analog samples with known K content. We will show the result of the calibration and some new statistical approaches in order to apprehend the effects of the long time ablation on rocks under high vacuum.

Devismes, D.↗