Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

First Results of the TOPSAR C-Band / L-Band Interferometer: Calibration and Differential Penetration

The NASA/JPL TOPSAR instrument recently was extended from a single wavelength C-band dual aperture synthetic aperture radar (SAR) interferometer to include a second wavelength at the L-band. Adding the second wavelength invites comparison of wavelength-diverse effects in topographic mapping of surfaces, with the principal goal of understanding the penetration of the radar signals in vegetation canopies, and determining the inferred topographic height. A first analysis of these data was conducted at two sites. Elkhorn Slough near Monterey, California presented flat, vegetation free terrain required for calibrating the radar interferometer parameters. A second site stretching from San Jose to Santa Cruz, California, which is heavily vegetated, provided the first test case for wavelength diverse penetration studies. Preliminary results show that: (a) the interferometer calibration determined at Elkhorn Slough is extenable to Laurel Quad and gives confidence in the C- and L-band height measurements; (b) Clear differences were observed between the C- and L-band heights associated with vegetation, with the C-band derived topographic heights generally higher than those from L-band. The noise level in the L-band interferometer is presently the limiting factor in penetration studies.

Rosen, Paul A.↗

First Results of the TOPSAR C-Band/L-Band Interferometer: Calibration and Differential Penetration

The NASA/JPL TOPSAR instrument recently was extended from a single- wavelength C-band (5.6 cm-lambda) dual aperture synthetic aperture radar interferometer to include a second wavelength at L-band (24 cm). Adding the second wavelength invites comparison of wavelength-diverse effects in topographic mapping of surfaces, with the principal goal of understanding the penetration of the radar signals in vegetation canopies, and determining the inferred topographic height. A first analysis of these data was conducted at two sites. Elkhorn Slough near Monterey, California presented flat, vegetation free terrain required for calibrating the radar interferometric parameters. A second site stretching from San Jose to Santa Cruz, CA, which is heavily vegetated, provided the first test case for wavelength diverse penetration studies. Preliminary results show that: (a) the interferometer calibration determined at Elkhorn Slough is extendable to Laurel Quad and gives confidence in the C- and L-band height measurements; and (b) Clear differences are observed between the C- and L-band heights associated with vegetation, with C-band-derived topographic heights generally higher than those from L-band. The noise level in the L-band interferometer is presently the limiting factor in penetration studies.

Rosen, Paul A.↗

Path Length Control in a Nulling Coronagraph with a MEMS Deformable Mirror and a Calibration Interferometer

We report progress on a nulling coronagraph intended for direct imaging of extrasolar planets. White light is suppressed in an interferometer, and phase errors are measured by a second interferometer. A 1020-pixel MEMS deformable mirror in the first interferometer adjusts the path length across the pupil. A feedback control system reduces deflections of the deformable mirror to order of 1 nm rms.

MEMS adaptive optics↗

First Results of the TOPSAR C-Band/L-Band Interferometer: Calibration and Differential Penetration

Teh NASA/JPL TOPSAR instrument recently was extended from a single wavelength C-band dual aperture synthetic aperture radar interferometer to include a second wavelength at L-band. Adding the second wavelength invites comparison of wavelength diverse effects in topographic mapping of surfaces, with the principal goal of understanding the penetration of the radar signals in vegetation canopies, and determining the inferred topographic height.

TOPSAR↗

Method of calibrating an interferometer and reducing its systematic noise

Methods of operation and data analysis for an interferometer so as to eliminate the errors contributed by non-responsive or unstable pixels, interpixel gain variations that drift over time, and spurious noise that would otherwise degrade the operation of the interferometer are disclosed. The methods provide for either online or post-processing calibration. The methods apply prescribed reversible transformations that exploit the physical properties of interferograms obtained from said interferometer to derive a calibration reference signal for subsequent treatment of said interferograms for interpixel gain variations. A self-consistent approach for treating bad pixels is incorporated into the methods.

Hammer, Philip D.↗

A Nulling Coronagraph for TPF-C

The nulling coronagraph is one of 5 instrument concepts selected by NASA for study for potential use in the TPF-C mission. This concept for extreme starlight suppression has two major components, a nulling interferometer to suppress the starlight to ~10(sup -10) per airy spot within 2 (lamda)/D of the star, and a calibration interferometer to measure the residual scattered starlight. The ability to work at 2 (lamda)/D dramatically improves the science throughput of a space based coronagraph like TPF-C. The calibration interferometer is an equally important part of the starlight suppression system. It measures the measures the wavefront of the scattered starlight with very high SNR, to 0.05nm in less than 5 minutes on a 5mag star. In addition, the post coronagraph wavefront sensor will be used to measure the residual scattered light after the coronagraph and subtract it in post processing to 1~2x10(sup -11) to enable detection of an Earthlike planet with a SNR of 5~10.

Terrestrial Planet Finder Coronagraph (TPF-C)↗

Binary pseudo-random array for calibration of interferometers with transmission spheres and cylinders

Binary pseudo-random array (BPRA) “white noise” artifacts are highly effective for characterizing the instrument transfer function (ITF) of surface topography metrology tools and wavefront measurement instruments. These BPRA artifacts feature all spatial frequencies within the instrument bandpass equally, resulting in a power spectral density with a white-noise-like character. This characteristic allows for direct ITF determination with uniform sensitivity across the entire spatial frequency range. We have developed a novel BPRA calibration standard that combines the diffractive pattern of a reflection computer-generated hologram (CGH) with the white noise generating BPRA pattern. By integrating these technologies using the same lithographic techniques, the resulting calibration sample enables ITF characterization of a Fizeau interferometer with a transmission sphere, or any nulling optic.

Munechika, K↗

System enables more complete calibrations of dynamic-pressure transducers

Absolute pressure calibration system using a Michelson interferometer calibrates phase characteristics and pressure sensitivities of the transducers that monitor acoustic or aerodynamic pressure fields. The interferometer uses a helium-neon laser light source and interchangeable acoustic signal generators to produce acoustic waves.

Pernet, D. F.↗

Computer Generated Hologram System for Wavefront Measurement System Calibration

Computer Generated Holograms (CGHs) have been used for some time to calibrate interferometers that require nulling optics. A typical scenario is the testing of aspheric surfaces with an interferometer placed near the paraxial center of curvature. Existing CGH technology suffers from a reduced capacity to calibrate middle and high spatial frequencies. The root cause of this shortcoming is as follows: the CGH is not placed at an image conjugate of the asphere due to limitations imposed by the geometry of the test and the allowable size of the CGH. This innovation provides a calibration system where the imaging properties in calibration can be made comparable to the test configuration. Thus, if the test is designed to have good imaging properties, then middle and high spatial frequency errors in the test system can be well calibrated. The improved imaging properties are provided by a rudimentary auxiliary optic as part of the calibration system. The auxiliary optic is simple to characterize and align to the CGH. Use of the auxiliary optic also reduces the size of the CGH required for calibration and the density of the lines required for the CGH. The resulting CGH is less expensive than the existing technology and has reduced write error and alignment error sensitivities. This CGH system is suitable for any kind of calibration using an interferometer when high spatial resolution is required. It is especially well suited for tests that include segmented optical components or large apertures.

Olczak, Gene↗

Optical fiber interferometer for the study of ultrasonic waves in composite materials

The possibility of acoustic emission detection in composites using embedded optical fibers as sensing elements was investigated. Optical fiber interferometry, fiber acoustic sensitivity, fiber interferometer calibration, and acoustic emission detection are reported. Adhesive bond layer dynamical properties using ultrasonic interface waves, the design and construction of an ultrasonic transducer with a two dimensional Gaussian pressure profile, and the development of an optical differential technique for the measurement of surface acoustic wave particle displacements and propagation direction are also examined.

Claus, R. O.↗

Thermal Expansion of Hafnium Carbide

Since hafnium carbide (HfC) has a melting point of 7029 deg. F, it may have many high-temperature applications. A literature search uncovered very little information about the properties of HfC, and so a program was initiated at the Lewis Research Center to determine some of the physical properties of this material. This note presents the results of the thermal expansion investigation. The thermal-expansion measurements were made with a Gaertner dilatation interferometer calibrated to an accuracy of +/- 1 deg. F. This device indicates expansion by the movement of fringes produced by the cancellation and reinforcement of fixed wave-length light rays which are reflected from the surfaces of two parallel quartz glass disks. The test specimens which separate these disks are three small cones, each approximately 0.20 in. high.

Grisaffe, Salvatore J.↗

Demonstration of the Wide-Field Imaging Interferometer Testbed Using a Calibrated Hyperspectral Image Projector

The Wide-field Imaging Interferometer testbed (WIIT) at NASA's Goddard Space Flight Center uses a dual-Michelson interferometric technique. The WIIT combines stellar interferometry with Fourier-transform interferometry to produce high-resolution spatial-spectral data over a large field-of-view. This combined technique could be employed on future NASA missions such as the Space Infrared Interferometric Telescope (SPIRIT) and the Sub-millimeter Probe of the Evolution of Cosmic Structure (SPECS). While both SPIRIT and SPECS would operate at far-infrared wavelengths, the WIIT demonstrates the dual-interferometry technique at visible wavelengths. The WIIT will produce hyperspectral image data, so a true hyperspectral object is necessary. A calibrated hyperspectral image projector (CHIP) has been constructed to provide such an object. The CHIP uses Digital Light Processing (DLP) technology to produce customized, spectrally-diverse scenes. CHIP scenes will have approximately 1.6-micron spatial resolution and the capability of . producing arbitrary spectra in the band between 380 nm and 1.6 microns, with approximately 5-nm spectral resolution. Each pixel in the scene can take on a unique spectrum. Spectral calibration is achieved with an onboard fiber-coupled spectrometer. In this paper we describe the operation of the CHIP. Results from the WIIT observations of CHIP scenes will also be presented.

Bolcar, Matthew R.↗

Phase linear interferometer experiment maintenance and calibration manual

This manual describes the necessary procedures for assuring continuous lightning sferics data collection at Marshall Space Flight Center. The phase linear interferometer experiment is under evaluation as a candidate RF sensor to support the space based optical lightning mapper system.

Goodman, S. J.↗

Radiometric calibration of IR Fourier transform spectrometers - Solution to a problem with the High-Resolution Interferometer Sounder

A calibrated Fourier transform spectrometer, known as the High-Resolution Interferometer Sounder (HIS), has been flown on the NASA U-2 research aircraft to measure the infrared emission spectrum of the earth. The primary use - atmospheric temperature and humidity sounding - requires high radiometric precision and accuracy (of the order of 0.1 and 1 C, respectively). To meet these requirements, the HIS instruments, the HIS instrument performs inflight radiometric calibration, using observations of hot and cold blackbody reference sources as the basis for two-point calibrations at each wavenumber. Initially, laboratory tests revealed a calibration problem with brightness temperature errors as large as 15 C between 600 and 900/cm. The symptom of the problem, which occurred in one of the three spectral bands of HIS, was a source-dependent phase response. Minor changes to the calibration equations completely eliminated the anomalous errors. The new analysis properly accounts for the situation in which the phase response for radiance from the instrument itself differs from that for radiance from an external source. The mechanism responsible for the dual phase response of the HIS instrument is identified as emission from the interferometer beam splitter.

Revercomb, Henry E.↗

Calibration and operation of a large space-based optical interferometer

The on-orbit calibration of the optics, structure, and control systems of the CSI Focus Mission Interferometer (FMI) is described. The calibration involves the estimation and propagation of both positional and rotational parameters and the propagation of both positional and rotational parameters at the nanometer/nanoradian level. It is shown that, given a nanometer class metrology system to monitor positional changes of critical optical elements, this calibration procedure should enable the FMI to perform 50 picoradian astrometry. The same Kalman filter that implements the initializing calibration of the interferometer baselines and internal pathlengths will also participate in the astrometric measurements of stellar positions.

Laskin, R. A.↗