Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration results”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Dark Energy Survey Year 3 results: calibration of lens sample redshift distributions using clustering redshifts with BOSS/eBOSS

ABSTRACT We present clustering redshift measurements for Dark Energy Survey (DES) lens sample galaxies used in weak gravitational lensing and galaxy clustering studies. To perform these measurements, we cross-correlate with spectroscopic galaxies from the Baryon Acoustic Oscillation Survey (BOSS) and its extension, eBOSS. We validate our methodology in simulations, including a new technique to calibrate systematic errors that result from the galaxy clustering bias, and we find that our method is generally unbiased in calibrating the mean redshift. We apply our method to the data, and estimate the redshift distribution for 11 different photometrically selected bins. We find general agreement between clustering redshift and photometric redshift estimates, with differences on the inferred mean redshift found to be below |Δz| = 0.01 in most of the bins. We also test a method to calibrate a width parameter for redshift distributions, which we found necessary to use for some of our samples. Our typical uncertainties on the mean redshift ranged from 0.003 to 0.008, while our uncertainties on the width ranged from 4 to 9 per cent. We discuss how these results calibrate the photometric redshift distributions used in companion papers for DES Year 3 results.

79 ASTRONOMY AND ASTROPHYSICS↗

The Terra Vega Active Light Source: A First Step in a New Approach to Perform Nighttime Absolute Radiometric Calibrations and Early Results Calibrating the VIIRS DNB

A fully automated, National Institute of Standards and Technology (NIST)-traceable artificial light source called Terra Vega has been developed to radiometrically calibrate the Visible Infrared Imaging Radiometer (VIIRS) Day Night Band (DNB) working in high gain stage (HGS) mode. The Terra Vega active point source is a calibrated integrating sphere that is only a fraction in size of a VIIRS DNB pixel. As such, it can be considered analogous to a ground-based photometric reference star. Vicarious calibrations that employ active point sources are different than those that make use of traditional extended sources and can be applyed to quantify the brightness of artificial light sources. The active source is successfully fielded, and early results indicate that it can be used to augment and validate the radiometric calibration of the VIIRS DNB HGS sensor on both the Suomi National Polar-orbiting Partnership (NPP) and NOAA-20 satellites. The VIIRS DNB HGS sensor can benefit from this technology as on-board calibration is challenging and hinges on transferring low gain stage (LGS) calibration using a solar diffuser to the medium gain stage (MGS) and HGS via regions of overlap. Current vicarious calibration methods that use a lunar-illuminated extended source estimate the HGS radiometric accuracy to within 8-15%. By comparison, early results and analysis showed that Terra Vega is stable to about 1%. Under clear dark night conditions, predicted top-of-atmosphere radiance from Terra Vega ranged between 1–11% of VIIRS measured values. Terra Vega’s excellent stability opens up new opportunities to validate and develop nighttime imaging applications based on point sources.

Ryan, Robert↗

Shock shapes on blunt bodies in hypersonic-hypervelocity helium, air, and CO2 flows, and calibration results in Langley 6-inch expansion tube

Shock shape results for flat-faced cylinders, spheres, and spherically blunted cones in various test gases, along with preliminary results from a calibration study performed in the Langley 6-inch expansion tube are presented. Free-stream velocities from 5 to 7 km/sec are generated at hypersonic conditions with helium, air, and CO2, resulting in normal shock density ratios from 4 to 19. Ideal-gas shock shape predictions, in which an effective ratio of specific heats is used as input, are compared with the measured results. The effect of model diameter is examined to provide insight to the thermochemical state of the flow in the shock layer. The regime for which equilibrium exists in the shock layer for the present air and CO2 test conditions is defined. Test core flow quality, test repeatability, and comparison of measured and predicted expansion-tube flow quantities are discussed.

Miller, C. G., III↗

Solar calibration results from two earth radiation budget experiment nonscanner instruments

The Earth Radiation Budget Experiment (ERBE) makes use of three sets of two independent, but complementary, flight instruments. The two instruments in each set include a three-channel narrow field-of-view scanning instrument (scanner) and a five-channel wide field-of-view staring instrument (nonscanner). The ERBE nonscanner instruments are designed for the conduction of broad spectral and spatial measurements of the earth's reflected solar and emitted radiation and the determination of the incident solar flux. The nonscanner solar calibration process is considered along with the solar calibration results. A description of the data processing algorithms is also provided, taking into account the earth viewing channels and the solar monitor.

Luther, M. R.↗

The Ames 12-Foot Pressure Tunnel: Tunnel Empty Flow Calibration Results and Discussion

An empty test section flow calibration of the refurbished NASA Ames 12-Foot Pressure Tunnel was recently completed. Distributions of total pressure, dynamic pressure, Mach number, flow angularity temperature, and turbulence are presented along with results obtained prior to facility demolition. Axial static pressure distributions along tunnel centerline are also compared. Test section model support geometric configurations will be presented along with a discussion of the issues involved with different model mounting schemes.

Peter T Zell↗

Calibration Results for J-ERS-1 SAR Data Produced by the Alaska SAR Facility

The Alaska SAR Facility has been receiving and processing SAR data from the J-ERS-1 satellite since Spring 1992. Corner reflectors have been set up for J-ERS-1 SAR calibration at a site near Delta Junction, in central Alaska. Image quality and calibration analysis results from the Delta Junction site and others will be presented in this paper. The impact of the 3-bit Analog-to-Digital Converter and the automatic stepping of the gain as a function of range in the J-ERS-1 radar receiver on calibration performance has been assessed. Preliminary observations on J-ERS-1 SAR data are that the average Signal-to-Noise ratio is generally fairly low, in the range 5-6dB. Azimuth ambiguity levels are higher than preflight analysis indicated. Over land, the dynamic range in the backscatter at L-band for approximately 36 degree incidence angle is often fairly high.

Freeman, A.↗

Calibration Results for J-ERS-1 SAR Data Produced by the Alaska SAR Facility

The Alaska SAR Facility has been receiving and processing SAR data from the J-ERS-1 satellite since Spring 1992. Corner reflectors have been set up for J-ERS-1 SAR calibration at a site near Delta Junction, in central Alaska. Image quality and calibration analysis results from the Delta Junction site and others will be presented in this paper. The impact of the 3-bit Analog-to-Digital Converter and the automatic stepping of the gain as a function of range in the J-ERS-1 radar receiver on calibration performance has been assessed. Preliminary observations on J-ERS-1 SAR data are that the average Signal-to-Noise ratio is generally fairly low, in the range 5-6 dB. Azimuth ambiguity levels are higher than preflight analysis indicated. Over land, the dynamic range in the backscatter at L-band for approximately 36 degree incidence angle is often fairly high...

Freeman, A.↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Comparison of MODIS Solar Diffuser Stability Monitor Calibration Results for Different Operational Configurations

The MODIS instruments on the Terra and Aqua spacecraft use a sunlit solar diffuser (SD), with an optional SD attenuation screen (SDS), to calibrate the reflective solar bands. A solar diffuser stability monitor (SDSM) is used to track the SD reflectance degradation on orbit, by taking a ratio of the detector response when viewing the SD compared to the response when viewing the sun. The MODIS SDSMs have been operated both with and without the SDS in place. The SDSMs have also been operated in both a fixed and an alternating mode. In the alternating mode, the SDSM detectors view the SD, sun, and a dark background in an alternating pattern with the view changing on every MODIS scan within a single orbit. In the fixed mode, the SDSM detectors are fixed on the sun view for one orbit, and then are fixed on the SD view for the following orbit. This paper reviews the history of the SDSM operational configurations used throughout the MODIS missions and discusses the differences in the SD degradation results, which may be due to differences in sun-satellite geometry, SD signal level, and stray light effects. We highlight Aqua SDSM results from two recent dates in October 2017 and July 2019, where both the fixed and alternating mode calibrations were run on the same day, providing clear examples of the calibration differences. Additionally, we show how mixing the results from calibrations done with and without the SDS for Aqua MODIS can provide more stable results.

Twedt, Kevin A.↗

Calibration Results for the AXAF Flux Contamination Monitor

The AXAF Flux Contamination Monitor (FCM) serves the purposes of transferring the absolute flux calibration from the ground calibration at the X-Ray Calibration Facility (XRCF) to operation on orbit and of detecting any changes in molecular contamination of the High-Resolution Mirror Assembly (HRMA) between ground calibration and the post-launch activation. We describe the design, construction, and characterization of the FCM radioactive sources, and their placement on the Forward Contamination Cover (FCC). We present results from FCM measurements with the AXAF focal-plane instruments, particularly the AXAF CCD Imaging Spectrometer (ACIS), during the ground calibration phase at the XRCF in 1997. Finally, we describe the plans for FCM on-orbit measurements during observatory activation and for the subsequent analysis.

Elsner, R. F.↗

Calibration Results for the AXAF Flux Contamination Monitor

The Flux Contamination Monitor (FCM) on the Advanced X-ray Astrophysics Facility (AXAF) serves the purposes of transfering the absolute flux calibration from the ground calibration at the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center to operation on orbit and of detecting any changes in molecular contamination of the High Resolution Mirror Assembly (HRMA) between ground calibration and the post-launch activation phase. we describe the design, construction, and characterization of the FCM radioactive sources, and their placement on the Forward Contamination Cover (FCC). We present results from FCM measurements with the AXAF focal plane instruments, particularly the AXAF CCD Imaging Spectrometer (ACIS), during the ground calibration phase at XRCF in 1997. Finally, we describe the plans for FCM on-orbit measurements during observatory activation and the subsequent analysis.

Elsner, Ronald F.↗

AVHRR and VISSR satellite instrument calibration results for both Cirrus and marine stratocumulus IFO periods

Accurate characterizations of some cloud parameters are dependent upon the absolute accuracy of satellite radiance measurements. Visible wavelength measurements from both the AVHRR and VISSR instruments are often used to study cloud characteristics. Both of these instruments were radiometrically calibrated prior to launch, but neither has an onboard device to monitor degradation after launch. During the FIRE/SRB cirrus Intensive Field Operation (IFO), a special effort was made to monitor calibration of these two instruments onboard the NOAA-9 and GOES-6 spacecraft. In addition, several research groups have combined their efforts to assess the long-term performance of both instruments. These results are presented, and a limited comparison is made with the ERBE calibration standard.

Whitlock, C. H.↗

Calibration results for NOAA-11 AVHRR channels 1 and 2 from congruent path aircraft observations

A method for using congruent atmospheric path aircraft-satellite observations to calibrate a satellite radiometer is presented. A calibrated spectroradiometer aboard a NASA ER-2 aircraft at an altitude of 19 km above White Sands (New Mexico) was oriented to view White Sands at the overpass time of the NOAA-11 AVHRR instrument along the same view vector as the satellite instrument. The data from six flights between November 1988 and October 1990 were transformed into corresponding estimates of AVHRR channel radiance at the satellite (derived from the aircraft measurements), and average counts (from the AVHRR measurements), both averaged across the footprint of the spectroradiometer. Prelaunch measurements of the AVHRR spectral response profiles are assumed, and the radiance spectrum measured by the spectroradiometer was adjusted to satellite altitude using the LOWTRAN-7 computer code. Results show reduced gains in both channel 1 (0.65 micron) and channel 2 (0.85 micron), compared to prelaunch values, with little further reduction in gain after 200 days in orbit. Results for the gain ratio (channel 1/channel 2), which is important for the calculation of the normalized vegetation index, show constant in-orbit values 5 percent above the prelaunch value.

Abel, Peter↗

Preliminary burst location calibration results for the BATSE instrument on CGRO

Preliminary results pertaining to burst location using BATSE Large Area Detector measurements of solar flares are presented. These solar flare measurements are currently being used to fine tune the calibration of our data analysis software. The current status of techniques for identifying and eliminating systematic errors from the data analysis tools is discussed. Data revealing the effects of the atmospheric scattering algorithm that will be implemented in the data analysis software are presented.

Pendleton, G. N.↗