Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Spectrally and Radiometrically Stable, Wideband, Onboard Calibration Source

The Onboard Calibration (OBC) source incorporates a medical/scientific-grade halogen source with a precisely designed fiber coupling system, and a fiber-based intensity-monitoring feedback loop that results in radiometric and spectral stabilities to within less than 0.3 percent over a 15-hour period. The airborne imaging spectrometer systems developed at the Jet Propulsion Laboratory incorporate OBC sources to provide auxiliary in-use system calibration data. The use of the OBC source will provide a significant increase in the quantitative accuracy, reliability, and resulting utility of the spectral data collected from current and future imaging spectrometer instruments.

Coles, James B.↗

Calibration source maintenance, characterization and development

The Standards and Calibration Office maintains visible and near infrared calibration sources for the use of various GSFC organizations instrument calibration needs and related field activities. These are large aperture spherical and hemispherical integrating sources designed to provide a spatially uniform absolute spectral radiance with a well-defined angular uniformity characteristic. In essence, the calibration and characterization efforts involve monitoring and documenting the stability and the absolute radiance of these calibration sources. These sources are recalibrated on a regular basis to both document any changes that might occur in the output of the sources and to provide the most up-to-date calibration data for the source users. Efforts included comparing the calibration numbers with those of a commercial calibration laboratory that was engaged to do independent calibrations. However, the most recent calibrations done by the independent laboratory and those done by GSFC personnel show a rather large discrepancy (10 to 15 percent). Efforts are underway to resolve these differences.

Mclean, J. T.↗

An in-situ movable calibration source for cryogenic particle detectors

A prototype device capable of moving a radioactive calibration source to multiple positions was operated at millikelvin temperatures using a modified commercial stepper motor. It was developed as an in-situ calibration strategy for cryogenic dark matter detectors. Data taken by scanning a calibration source across multiple radial positions of a prototype dark matter detector demonstrated its functionality. Construction, heat load, and operation of the device are discussed, as is the effect of the motor on the detector operation. A sample dataset taken over multiple positions of a SuperCDMS detector is presented as an example of the utility of such a device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Long-Term Quality Control Data for a 137 Cs Dosimetry Calibration Source

Strict quality assurance programs are required for many radiological applications, but these seldom exist for verifying dosimetry calibration sources. After initial characterization of a dosimetry calibration facility, quality control procedures are recommended to ensure the early detection of any changes or malfunctions. These also result in refined knowledge about average dose rate and experimental variations in dose delivery. This paper describes the implementation of a phase I quality control protocol for a 137 Cs dosimetry calibration source and includes an analysis of the resulting data collected over a 24-mo period. During this time, substantial data was collected to establish trial control limits. Air kerma rate measurements were obtained using an ion chamber and were adjusted for decay, corrected for ambient temperature, pressure and humidity, and then analyzed using quality control charts. Three variations of rational subgrouping methods were used in order to find assignable causes of error, and Nelson's Rules were followed to detect any non-random statistical variations. Measurements were subgrouped according to same-day measurements in order to detect positional errors as well as atmospheric correction errors. Additionally, measurements were subgrouped according to analogous experimental setups in order to detect failure in equipment or incorrect settings. Both were analyzed using the X-bar and R chart method. Similarly, individuals and moving ranges charts were used to carefully examine each position in order to observe any situational errors that may occur which include timing, positional, or interference errors. Each method was successful in identifying unique out-of-control data points that occurred during the phase I application of forming control limits. Furthermore, over the 24-mo period, enough data points were deemed in-control to establish reliable trial limits. Future experiments will include the phase II application of gaining more reliable measurements in order to fine-tune the limits, as well as performing a designed experiment, where variables are purposefully changed in order to test the variation of the data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Common Calibration Source for Monitoring Long-term Ozone Trends

Accurate long-term satellite measurements are crucial for monitoring the recovery of the ozone layer. The slow pace of the recovery and limited lifetimes of satellite monitoring instruments demands that datasets from multiple observation systems be combined to provide the long-term accuracy needed. A fundamental component of accurately monitoring long-term trends is the calibration of these various instruments. NASA s Radiometric Calibration and Development Facility at the Goddard Space Flight Center has provided resources to minimize calibration biases between multiple instruments through the use of a common calibration source and standardized procedures traceable to national standards. The Facility s 50 cm barium sulfate integrating sphere has been used as a common calibration source for both US and international satellite instruments, including the Total Ozone Mapping Spectrometer (TOMS), Solar Backscatter Ultraviolet 2 (SBUV/2) instruments, Shuttle SBUV (SSBUV), Ozone Mapping Instrument (OMI), Global Ozone Monitoring Experiment (GOME) (ESA), Scanning Imaging SpectroMeter for Atmospheric ChartographY (SCIAMACHY) (ESA), and others. We will discuss the advantages of using a common calibration source and its effects on long-term ozone data sets. In addition, sphere calibration results from various instruments will be presented to demonstrate the accuracy of the long-term characterization of the source itself.

Kowalewski, Matthew↗

Narrow Line X-Ray Calibration Source for High Resolution Microcalorimeters

We are developing a narrow line calibration source for use with X-ray microcalorimeters. At energies below 300 electronvolts fluorescent lines are intrinsically broad, making calibration of high resolution detectors difficult. This source consists of a 405 nanometers (3 electronvolts) laser diode coupled to an optical fiber. The diode is pulsed to create approximately one hundred photons in a few microseconds. If the pulses are short compared to the rise time of the detector, they will be detected as single events with a total energy in the soft X-ray range. Poisson fluctuations in photon number per pulse create a comb of X-ray lines with 3 electronvolts spacing, so detectors with energy resolution better than 2 electronvolts are required to resolve the individual lines. Our currently unstabilized diode has a multimode width less than 1 nanometer, giving a 300 electronvolt event a Full width at half maximum (FWHM) less than 0.1 electronvolts. By varying the driving voltage, or pulse width, the source can produce a comb centered on a wide range of energies. The calibration events are produced at precisely known times. This allows continuous calibration of a flight mission without contaminating the observed spectrum and with minimal deadtime.

high resolution detectors↗

A Common Calibration Source Framework for Fully-Polarimetric and Interferometric Radiometers

Two types of microwave radiometry--synthetic thinned array radiometry (STAR) and fully-polarimetric (FP) radiometry--have received increasing attention during the last several years. STAR radiometers offer a technological solution to achieving high spatial resolution imaging from orbit without requiring a filled aperture or a moving antenna, and FP radiometers measure extra polarization state information upon which entirely new or more robust geophysical retrieval algorithms can be based. Radiometer configurations used for both STAR and FP instruments share one fundamental feature that distinguishes them from more 'standard' radiometers, namely, they measure correlations between pairs of microwave signals. The calibration requirements for correlation radiometers are broader than those for standard radiometers. Quantities of interest include total powers, complex correlation coefficients, various offsets, and possible nonlinearities. A candidate for an ideal calibration source would be one that injects test signals with precisely controllable correlation coefficients and absolute powers simultaneously into a pair of receivers, permitting all of these calibration quantities to be measured. The complex nature of correlation radiometer calibration, coupled with certain inherent similarities between STAR and FP instruments, suggests significant leverage in addressing both problems together. Recognizing this, a project was recently begun at NASA Goddard Space Flight Center to develop a compact low-power subsystem for spaceflight STAR or FP receiver calibration. We present a common theoretical framework for the design of signals for a controlled correlation calibration source. A statistical model is described, along with temporal and spectral constraints on such signals. Finally, a method for realizing these signals is demonstrated using a Matlab-based implementation.

Kim, Edward J.↗

Study for the analysis of the observations, and numerical data representing the planets as far-infrared calibration sources

The existing radiative transfer and inversion programs will be modified for application to the atmospheres of Uranus, Neptune, and Jupiter. The programs will be employed for analysis of KAO planetary observations in order to develop far infrared photometric calibration standards. This work will be carried out on MSFC computers. The expected end product of this task is a working program for analysis of the observations, and numerical data representing the planets as far-infrared calibration sources.

Wu, Shi Tsan↗

Evaluation of the Earth Radiation Budget Experiment (ERBE) shortwave channel's stability using in-flight calibration sources

The Earth Radiation Budget Experiment (ERBE) radiometers were designed to make absolute measurements of the incoming solar, earth-reflected solar, and earth-emitted fluxes for investigations of the earth's climate system. Thermistor bolometers were the sensors used for the ERBE scanning radiometric package. Each thermistor bolometer package consisted of three narrow field of view broadband radiometric channels measuring shortwave, longwave, and total (0.2 micron to 50 microns) radiation. The in-flight calibration facilities include Mirror Attenuator Mosaics, shortwave internal calibration source, and internal blackbody sources to monitor the long-term responsivity of the radiometers. This paper describes the in-flight calibration facilities, the calibration data reduction techniques, and the results from the in-flight shortwave channel calibrations. The results indicate that the ERBE shortwave detectors were stable to within +/- 1 percent for up to five years of flight operation.

Gibson, Michael A.↗

Development of a 127 Xe calibration source for nEXO

Here, we study a possible calibration technique for the nEXO experiment using a 127 Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136 Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127 Xe and its small Q-value compared to that of 136 Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

47 OTHER INSTRUMENTATION↗

Cryogenic blackbody radiation calibration source

A cryogenic blackbody radiation source for providing target temperatures between room temperature and -100 C was designed, fabricated, and tested. This blackbody radiation source is intended for calibration of radiometric infrared imaging systems down to -100 C. The construction and operating principles of this apparatus are described. The long term and short term stability of the radiant source have been investigated. The emittance of the source and the source radiant uniformity have been addressed.

Burkett, Cecil G., Jr.↗

Calibration source for remote sensors

The source described was developed as a calibration target for the multispectral scanner (MSS) which was flown on the Earth Resources Technology Satellite A (LANDSAT 1). The wavelength region of interest covered the four (4) MSS bands extending from 0.5 to 1.1 micrometers, although the target was calibrated from 0.32 to 2.5 micrometers. The following characteristics for the target were required: (1) large aperture, sufficient to accommodate an instrument with a 9 inch (23 centimeters(cm)) aperture and 2 1/2 deg field of view (fov), (2) highly diffuse energy from target, (3) high spatial uniformity across aperture area of source, (4) spectrally calibrated in absolute units, (5) stable output over long periods of time (1-2 yrs), and (6) rugged, yet portable enough to be easily transported long distances without detrimental effects on the operational capabilities of the target. Two approaches were considered: a thirty (30) inch (76 cm) diameter integrating sphere with a twelve inch (30.5 cm) exit port, or the use of one hemisphere of a 76 cm sphere in conjunction with a Kodak ektolite screen. The screen has the property of reflecting back uniformly into a well defined area the majority of the light received. After some preliminary trials it seemed that the 76 cm sphere would give the most satisfactory results.

Mclean, J. T.↗

Calibration sources for the LEGEND-200 experiment

In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the Q-value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in 76 Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resolution of the germanium diodes, custom-made, low-neutron emission 228 Th sources are regularly deployed in the vicinity of the crystals. Here we describe the production process of the 17 sources available for installation in the experiment, the measurements of their alpha- and gamma- activities, as well as the determination of the neutron emission rates with a low-background LiI(Eu) detector operated deep underground. With a flux of ( 4.27 ± 0.60 stat ± 0.92 syst ) × 10 -4 n / (kBq·s), approximately one order of magnitude below that of commercial sources, the neutron-induced background rate, mainly from the activation of 76 Ge, is negligible compared to other background sources in LEGEND-200.

47 OTHER INSTRUMENTATION↗

Simple ultraviolet calibration source with reference spectra and its use with the Galileo orbiter ultraviolet spectrometer

A simple compact electron impact laboratory source of UV radiation has been developed and is used to obtain calibrated optically thin VUV spectra and synthetic spectral models for important molecular band systems of H2, N2, and the n 1P0 Rydberg series of He. The relative spectral intensity of the electron impact source can be used as the primary calibration standard for VUV instrumentation in the 80-230 nm range and with FWHM of not less than 0.4 nm. The accuracy of the present method is 10 percent in the FUV and 20 percent in the EUV. Results for calibration of the Galileo orbiter ultraviolet spectrometer have been compared with those obtained using other methods.

Shemansky, D. E.↗

Development of 17 N as a time-tagged neutron source for calibration of large antineutrino detectors

Large antineutrino detectors hold the potential for remote nuclear reactor monitoring and discovery, which is of great interest for nonproliferation and treaty verification applications. Correlated-particle calibration sources are especially useful for large-volume designs based on detection of inverse beta-decay events, as the timing information of the coincident particles improves background rejection and event reconstruction. 17 N is a promising calibration source since it emits beta-correlated delayed neutrons and can be produced relatively easily using high-energy neutrons. In this work, we examine the feasibility of 17 N as a time-tagged calibration source for large antineutrino detectors. 17 N was produced using a DT neutron generator from a water sample enriched in 17 O, and the observed production rates were found to be consistent with previous measurements of the 17 O(n,p) 17 N reaction cross-section. As a result, time-tagging of 17 N delayed neutrons is demonstrated via beta-neutron coincidence measurements conducted using a specialized beta detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the performance of event reconstruction algorithms in the JSNS 2 experiment using a 252 Cf calibration source

JSNS 2 investigates short-baseline neutrino oscillations using a 24-meter baseline and a 17-tonne Gd-loaded liquid scintillator target. Accurate event-reconstruction algorithms are crucial for analyzing experimental data. The algorithms undergo meticulous validation through calibration with a 252 Cf source. This paper outlines the methodology and evaluates the reconstruction performance, focusing on neutrino interactions up to approximately 50 MeV for sterile neutrino searches. Both 252 Cf and Michel electron events are studied to evaluate reconstruction accuracy. The analysis concludes that the uncertainty of the fiducial volume, with an appropriate correction, is much less than the requirement of JSNS 2 requirement (10%). Furthermore, the energy resolution is measured to be 3.3 ± 0.1% for the Michel electron endpoint and 4.3 ± 0.1% for the n-Gd peak in the central region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spectrally and Radiometrically Stable Wide-Band on Board Calibration Source for In-Flight Data Validation in Imaging Spectroscopy Applications

The quality of the quantitative spectral data collected by an imaging spectrometer instrument is critically dependent upon the accuracy of the spectral and radiometric calibration of the system. In order for the collected spectra to be scientifically useful, the calibration of the instrument must be precisely known not only prior to but during data collection. Thus, in addition to a rigorous in-lab calibration procedure, the airborne instruments designed and built by the NASA/JPL Imaging Spectroscopy Group incorporate an on board calibrator (OBC) system with the instrument to provide auxiliary in-use system calibration data. The output of the OBC source illuminates a target panel on the backside of the foreoptics shutter both before and after data collection. The OBC and in-lab calibration data sets are then used to validate and post-process the collected spectral image data. The resulting accuracy of the spectrometer output data is therefore integrally dependent upon the stability of the OBC source. In this paper we describe the design and application of the latest iteration of this novel device developed at NASA/JPL which integrates a halogen-cycle source with a precisely designed fiber coupling system and a fiber-based intensity monitoring feedback loop. The OBC source in this Airborne Testbed Spectrometer was run over a period of 15 hours while both the radiometric and spectral stabilities of the output were measured and demonstrated stability to within 1% of nominal.

visible spectrometers↗