Search NASA⌕ Search

SEARCH · Search NASA

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Report on the Radiation Effects Testing of the Infrared and Optical Transition Radiation Camera Systems

Presented in this report are the results tests performed at Argonne National Lab in collaboration with Los Alamos National Lab to assess the reliability of the critical 99 Mo production facility beam monitoring diagnostics. The main components of the beam monitoring systems are two cameras that will be exposed to radiation during accelerator operation. The purpose of this test is to assess the reliability of the cameras and related optical components when exposed to operational radiation levels. Both X-ray and neutron radiation could potentially damage camera electronics as well as the optical components such as lenses and windows. This report covers results of the testing of component reliability when exposed to X-ray radiation. With the information from this study we provide recommendations for implementing protective measures for the camera systems in order to minimize the occurrence of radiation-induced failure within a ten month production run cycle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact tomography camera system using a multianode photomultiplier tube for compact torus experiments

A compact tomography camera system consisting of a photomultiplier tube, a multislit optical system, and a band-pass interference filter has been developed. The viewing area and spatial resolution can be configured by the arrangement of the slit system. The camera system has been specially designed for self-organized compact torus experiments having strong magnetohydrodynamics events with a submicrosecond time-scale. The developed system has been tested on a field-reversed configuration formed by the field-reversed theta-pinch. Performance evaluation of the system has been performed by comparison to the former optical system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kraken Camera System

Specification sheet for Kraken camera system being developed by NNSS Transformational Diagnostics and Imaging in Los Alamos. Will be shared internally and externally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A wide dynamic range x-ray streak camera system

An x-ray streak camera with wide dynamic range and a large slit photocathode of 30 mm length has been developed and calibrated. In order to achieve wide dynamic range, a conventional streak tube has been improved and the camera system has been designed without microchannel plate electron amplifier. As a result, a dynamic range of 922 is achieved in a single shot mode with laser pulse of 30 ps (full width at half maximum) at time resolution of better than 31 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A neutron camera system for MAST

A prototype neutron camera has been developed and installed at MAST as part of a feasibility study for a multichord neutron camera system with the aim to measure the spatial and time resolved 2.45 MeV neutron emissivity profile. Liquid scintillators coupled to a fast digitizer are used for neutron/gamma ray digital pulse shape discrimination. The preliminary results obtained clearly show the capability of this diagnostic to measure neutron emissivity profiles with sufficient time resolution to study the effect of fast ion loss and redistribution due to magnetohydrodynamic activity. A minimum time resolution of 2 ms has been achieved with a modest 1.5 MW of neutral beam injection heating with a measured neutron count rate of a few 100 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the radial neutron camera system for the HL-2A tokamak

A new radial neutron camera system has been developed and operated recently in the HL-2A tokamak to measure the spatial and time resolved 2.5 MeV D-D fusion neutron, enhancing the understanding of the energetic-ion physics. The camera mainly consists of a multichannel collimator, liquid-scintillation detectors, shielding systems, and a data acquisition system. Measurements of the D-D fusion neutrons using the camera have been successfully performed during the 2015 HL-2A experiment campaign. The measurements show that the distribution of the fusion neutrons in the HL-2A plasma has a peaked profile, suggesting that the neutral beam injection beam ions in the plasma have a peaked distribution. It also suggests that the neutrons are primarily produced from beam-target reactions in the plasma core region. The measurement results from the neutron camera are well consistent with the results of both a standard {sup 235}U fission chamber and NUBEAM neutron calculations. In this paper, the new radial neutron camera system on HL-2A and the first experimental results are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kraken Imager and Camera Systems

Presentation describes the Kraken imager and camera systems under development for use at the Nevada National Security Site for work conducted by the National Nuclear Security Administration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Study of an Easily Controlled Ultra-High-Resolution Pixel-Matched Parallel-Hole Collimator with a Small Cadmium Zinc Telluride Pixelated Gamma Camera System

The aim of this study was to develop an easily controlled, ultra-high-resolution, tungsten parallel-hole collimator based on a small pixelated gamma camera system. A small cadmium zinc telluride (CZT) pixelated semiconductor detector (eValuator-2500 detector [eV product, Saxonburg, PA]) was evaluated. This detector is composed of an array of 51.2 × 0.8 × 3-mm{sup 3} individual CZT crystal elements. The ultra-high-resolution, pixel-matched, parallel-hole collimators consisted of six layers, with the same between the hole and pixel size. The basic characteristics of the imaging system, such as sensitivity and spatial resolution, was measured using a {sup 57}Co point source. The measured averages of sensitivity and spatial resolution varied depending on the septal heights of the ultra-high-resolution parallel-hole collimator and source-to-collimator distances. When the 30-mm septal height was at 1-cm source-to-collimator distance, the spatial resolution was approximately 0.85 mm. Using 5-mm septal height, over 0.3 cps/kBq sensitivity was achieved. One advantage of our system is the use of stacked collimators that can select the best combination of system sensitivity and spatial resolution. Our results demonstrated that the developed CZT–pixelated gamma camera system using an ultra-high-resolution parallel-hole collimator of various collimator geometric designs has potential as an effective instrument.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-774: Use of a Scintillator-Mirror-Camera System for the Measurement of MLC Leakage Radiation with the CyberKnife M6 System

Purpose: A technique using a scintillator-mirror-camera system to measure MLC leakage was developed to provide an efficient alternative to film dosimetry while maintaining high spatial resolution. This work describes the technique together with measurement uncertainties. Methods: Leakage measurements were made for the InCise™ MLC using the Logos XRV-2020A device. For each measurement approximately 170 leakage and background images were acquired using optimized camera settings. Average background was subtracted from each leakage frame before filtering the integrated leakage image to replace anomalous pixels. Pixel value to dose conversion was performed using a calibration image. Mean leakage was calculated within an ROI corresponding to the primary beam, and maximum leakage was determined by binning the image into overlapping 1mm x 1mm ROIs. 48 measurements were performed using 3 cameras and multiple MLC-linac combinations in varying beam orientations, with each compared to film dosimetry. Optical and environmental influences were also investigated. Results: Measurement time with the XRV-2020A was 8 minutes vs. 50 minutes using radiochromic film, and results were available immediately. Camera radiation exposure degraded measurement accuracy. With a relatively undamaged camera, mean leakage agreed with film measurement to ≤0.02% in 92% cases, ≤0.03% in 100% (for maximum leakage the values were 88% and 96%) relative to reference open field dose. The estimated camera lifetime over which this agreement is maintained is at least 150 measurements, and can be monitored using reference field exposures. A dependency on camera temperature was identified and a reduction in sensitivity with distance from image center due to optical distortion was characterized. Conclusion: With periodic monitoring of the degree of camera radiation damage, the XRV-2020A system can be used to measure MLC leakage. This represents a significant time saving when compared to the traditional film-based approach without any substantial reduction in accuracy.

60 APPLIED LIFE SCIENCES↗

MONICA: a compact, portable dual gamma camera system for mouse whole-body imaging

Introduction We describe a compact, portable dual-gamma camera system (named "MONICA" for MObile Nuclear Imaging CAmeras) for visualizing and analyzing the whole-body biodistribution of putative diagnostic and therapeutic single photon emitting radiotracers in animals the size of mice. Methods Two identical, miniature pixelated NaI(Tl) gamma cameras were fabricated and installed ?looking up? through the tabletop of a compact portable cart. Mice are placed directly on the tabletop for imaging. Camera imaging performance was evaluated with phantoms and field performance was evaluated in a weeklong In-111 imaging study performed in a mouse tumor xenograft model. Results Tc-99m performance measurements, using a photopeak energy window of 140 keV?10%, yielded the following results: spatial resolution (FWHM at 1 cm), 2.2 mm; sensitivity, 149 cps (counts per seconds)/MBq (5.5 cps/μCi); energy resolution (FWHM, full width at half maximum), 10.8%; count rate linearity (count rate vs. activity), r2=0.99 for 0?185 MBq (0?5 mCi) in the field of view (FOV); spatial uniformity, <3% count rate variation across the FOV. Tumor and whole-body distributions of the In-111 agent were well visualized in all animals in 5-min images acquired throughout the 168-h study period. Conclusion Performance measurements indicate that MONICA is well suited to whole-body single photon mouse imaging. The field study suggests that inter-device communications and user-oriented interfaces included in the MONICA design facilitate use of the system in practice. We believe that MONICA may be particularly useful early in the (cancer) drug development cycle where basic whole-body biodistribution data can direct future development of the agent under study and where logistical factors, e.g., limited imaging space, portability and, potentially, cost are important.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: Range verification system using edge detection method for a scintillator and a CCD camera system

Purpose: Three-dimensional irradiation with a scanned carbon-ion beam has been performed from 2011 at the authors’ facility. The authors have developed the rotating-gantry equipped with the scanning irradiation system. The number of combinations of beam properties to measure for the commissioning is more than 7200, i.e., 201 energy steps, 3 intensities, and 12 gantry angles. To compress the commissioning time, quick and simple range verification system is required. In this work, the authors develop a quick range verification system using scintillator and charge-coupled device (CCD) camera and estimate the accuracy of the range verification. Methods: A cylindrical plastic scintillator block and a CCD camera were installed on the black box. The optical spatial resolution of the system is 0.2 mm/pixel. The camera control system was connected and communicates with the measurement system that is part of the scanning system. The range was determined by image processing. Reference range for each energy beam was determined by a difference of Gaussian (DOG) method and the 80% of distal dose of the depth-dose distribution that were measured by a large parallel-plate ionization chamber. The authors compared a threshold method and a DOG method. Results: The authors found that the edge detection method (i.e., the DOG method) is best for the range detection. The accuracy of range detection using this system is within 0.2 mm, and the reproducibility of the same energy measurement is within 0.1 mm without setup error. Conclusions: The results of this study demonstrate that the authors’ range check system is capable of quick and easy range verification with sufficient accuracy.

60 APPLIED LIFE SCIENCES↗

PiCAM: A Raspberry Pi-based open-source, low-power camera system for monitoring plant phenology in Arctic environments

Time-lapse cameras have been widely used as a tool to monitor the timing of seasonal vegetation growth. These simple, relatively inexpensive systems can provide high-frequency observations of leaf development and demography which are critical data sets needed to characterize plant phenology from species to landscapes. This is important for understanding how plants are responding to global changes, as well as for validating satellite-derived phenology products. However, in remote regions including the high-latitude Arctic, deploying time-lapse cameras could be challenging. The remoteness and lack of widespread power and telecommunications infrastructure limit options for the installation, maintenance and retrieval of data and equipment, and make it difficult for cameras to survive in extreme weather (e.g. long cold winters). To improve our understanding of Arctic phenology, new technologies are required to address these challenges. Here, we present a novel, low-power, compact, lightweight time-lapse camera system, called power-interval camera automation module (PiCAM). The PiCAM was designed with explicit consideration to simplify deployment (i.e. without a need for external power supplies) of camera systems and to address the challenges of camera survival in harsh Arctic environments. In this paper, we describe the design, setup and technical details of the PiCAM and provide a roadmap for how to build and operate these systems. As proof of concept, we deployed 26 PiCAMs at three low-Arctic tundra sites on the Seward Peninsula, Alaska in early August 2021 for characterizing Arctic plant phenology. Of the 26 PiCAMs, 70% remained active at the point of our revisit in late July 2022 despite the extreme winter temperatures they experienced (< –30°C, heavy snow cover). We extracted key plant phenology metrics from the PiCAMs and captured strong differences across key Arctic plant species. We showed that the PiCAM has the potential to be widely used for monitoring plant phenology across the broader Arctic region, addressing the need for ground-based understanding of Arctic phenological diversity to develop knowledge of plant response to climate change and to validate remote sensing products.

54 ENVIRONMENTAL SCIENCES↗

TEAMER: A Tow Body Optical Camera System

Archive consists of design drawings, assembly instructions, and bill of materials (BOM) for a Igiugig Village Council (IVC)/Ocean Renewable Power company (ORPC) tow body camera system for underwater environmental monitoring using optical cameras. This work was conducted by the University of Washington's Applied Physics Laboratory on behalf of the Igiugig Village Council through TEAMER RFTS 1 (request for technical support) program.

16 TIDAL AND WAVE POWER↗

TH-CD-201-10: Highly Efficient Synchronized High-Speed Scintillation Camera System for Measuring Proton Range, SOBP and Dose Distributions in a 2D-Plane

Purpose: Proton therapy (PT) delivery is complex and extremely dynamic. Therefore, quality assurance testing is vital, but highly time-consuming. We have developed a High-Speed Scintillation-Camera-System (HS-SCS) for simultaneously measuring multiple beam characteristics. Methods: High-speed camera was placed in a light-tight housing and dual-layer neutron shield. HS-SCS is synchronized with a synchrocyclotron to capture individual proton-beam-pulses (PBPs) at ∼504 frames/sec. The PBPs from synchrocyclotron trigger the HS-SCS to open its shutter for programmed exposure-time. Light emissions within 30×30×5cm3 plastic-scintillator (BC-408) were captured by a CCD-camera as individual images revealing dose-deposition in a 2D-plane with a resolution of 0.7mm for range and SOBP measurements and 1.67mm for profiles. The CCD response as well as signal to noise ratio (SNR) was characterized for varying exposure times, gains for different light intensities using a TV-Optoliner system. Software tools were developed to analyze ∼5000 images to extract different beam parameters. Quenching correction-factors were established by comparing scintillation Bragg-Peaks with water scanned ionization-chamber measurements. Quenching corrected Bragg-peaks were integrated to ascertain proton-beam range (PBR), width of Spared-Out-Bragg-Peak (MOD) and distal.

07 ISOTOPE AND RADIATION SOURCES↗

In-situ visual inspection of the CASTOR V/21 used nuclear fuel dry storage cask: a demonstration of camera system capabilities - 15505

On June 11, 2014 the Gesellschaft fur Nuklear Service (GNS) CASTOR V/21 spent fuel dry storage cask was inspected in-situ at the Idaho Nuclear Technology and Engineering Center (INTEC). The purpose of this inspection is to demonstrate and document the technology necessary to perform inspections of spent fuel dry storage casks. The inspection includes internal temperature measurement, internal radiation measurement, and a visual examination using a bore-scope type camera system inserted through the cask fill/drain penetration. It is concluded from this inspection that in-situ inspections of bolted lid spent fuel storage containers is possible using current camera technologies. Using 3D Phase Measurement Technology, measurements of entities such as cracks or corrosion are possible. The internal surfaces of the CASTOR V/21 cask that were inspected were free of corrosion and exhibited no evidence of degradation. One crack identified in previous inspections was examined and appeared the same as in the previous inspections. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A low noise CMOS camera system for 2D resonant inelastic soft X-ray scattering

Resonant Inelastic X-ray Scattering (RIXS) is a powerful spectroscopic technique to study quantum properties of materials in the bulk. A novel variant of RIXS, called 2D RIXS, enables concurrent measurement of the scattered X-ray spectrum for a wide range of input energies, improving on the typically low throughput of 1D RIXS. In the soft X-ray domain, 2D RIXS demands an X-ray camera system with small pixels, large area, high quantum efficiency and low noise to limit the false detection rate in long duration exposures. We designed and implemented a 7.5 Megapixel back-illuminated CMOS detector with 5 μm pixels and high quantum efficiency in the 200–1,000 eV X-ray energy range for the QERLIN 2D RIXS spectrometer at the Advanced Light Source. The QERLIN beamline and detector are currently in commissioning. The camera noise from in-situ 3 s long dark exposures is 7e - or less and the leakage current is 6.5 × 10 -3 e - /(pixel ∙ s). For individual 500 eV X-rays, the expected efficiency is greater than 75% and the false detection rate is ~1 × 10 -5 per pixel.

47 OTHER INSTRUMENTATION↗