Comments on “Comparison of energy consumption in desalination by capacitive deionization and reverse osmosis”

Capacitive deionization (CDI) is an emerging brackish water desalination technology in which ions are removed from water by electrostatically adsorbing them onto porous electrodes. Recently, Qin et al. presented an estimate of energy consumption for CDI schemes, and compared the energy consumption of CDI to the energy consumption of a particular reverse osmosis operation scheme which they propose. Qin et al. estimate very high values of energy consumption in CDI for brackish water desalination (e.g. ~1 to 2 g/L salt solution), and these values and trends do not agree with published experiments for CDI or with experimentally validated models for CDI. The current comment identifies important scaling errors and incorrect values in their model resistance parameters, and then discusses unphysical trends predicted by their model. We do not attempt provide a comprehensive review of their model, operation, estimates, and figures, but rather concentrate on several key issues. We present our comments in two sections dealing with resistances and energy metrics, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical modeling of ion transport and adsorption in porous media: A pore-scale study for capacitive deionization desalination

In this report a pore-scale model is presented to simulate the dynamic ion transport and adsorption processes in porous electrodes used for capacitive deionization (CDI). The Stokes equation governing water flow is solved using the lattice Boltzmann method and Nernst-Planck equation describing ion transport is solved using the finite volume method. The ion adsorption process is considered at the surface of carbon electrodes. After validation against analytical solutions and published results, the model is used to study the coupled water flow, ion transport and adsorption in both two-dimensional and three-dimensional porous CDI electrodes at the pore scale. The effect of electrode microstructure, electrical potential and flow velocity on the adsorption processes is quantitatively investigated, and the relative importance of various parameters is determined. The presented model can be a powerful numerical tool to quantitatively analyze ion transport and adsorption in porous electrodes, and may provide useful information for the design and optimization of CDI electrodes and operating conditions for desired desalination efficiency, water throughput and cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon electrodes based capacitive deionization for the desalination of water

A capacitive deionization system includes first and second electrodes comprising tire derived carbon particles obtained from a carbonaceous waste-tire source material containing carbon black. A conductive polymer coating on the carbon particles forms coated carbon particles. The first electrode and the second electrode define a flow channel there between, having a first opening for conducting saline solution into the flow channel and a second opening for conducting treated saline solution from the flow channel. A first current collector is provided for the first electrode and a second current collector is provided for the second electrode. An electrical connection between the first and second electrodes. A method of making a system for the capacitive deionization of a salt from a liquid, and a method for the capacitive desalination of a saline solution are also disclosed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Developing Novel Electrode Materials for Aqueous Battery

Aqueous rechargeable batteries (ARBs) are particularly interesting for large-scale energy storage due to their inherent safety, superior rate capability and environmental friendliness. However, ARBs are not widely explored as yet, so we proposed designing, preparing, and testing new intercalation materials for ARBs. Development of these electrodes will enrich the electrode chemistry of existing ARBs, open up new avenues for high-performance electrode and system design, offer opportunities to improve energy efficiency of water purification, and inform future development of controls strategies and management systems for stationary aqueous energy storage. Researchers from Bosch and LBNL collaborated on relevant materials to pursue and the general design of experiments to implement. Bosch researchers prepared and fabricated the electrodes and used various characterization facilities at LBNL to evaluate electrode performance in-device. The research collaboration resulted in identifying electrode materials capable of Na + and Ca 2+ intercalation in aqueous systems, and their application for desalination was explored using testing platform available at LBNL. Besides the specific materials and their performance, the data collected during the study was also used to inform a broader techno-economic analysis to compare intercalation-desalination technique to commercially available capacitive desalination approach. Outcomes of this research effort will be published in peer-reviewed journals.

25 ENERGY STORAGE↗

A review of transport models in charged porous electrodes

There is increased interest in many different processes based upon interactions between a charged solid surface and a liquid electrolyte. Energy storage in capacitive porous materials, ionic membranes, capacitive deionization (CDI) for water desalination, capacitive energy generation, removal of heavy ions from wastewater streams, and geophysical applications are some examples of these processes. Process development is driven by the production of porous materials with increasing surface area. Understanding of the physical phenomena occurring at the charged solid-electrolyte interface will significantly improve the design and development of more effective applied processes. The goal of this work is to critically review the current knowledge in the field. The focus is on concepts behind different models. We start by briefly presenting the classical electrical double layer (EDL) models in flat surfaces. Then, we discuss models for porous materials containing macro-, meso-, and micro-pores. Some of the current models for systems comprising two different pore sizes are also included. Finally, we discuss the concepts behind the most common models used for ionic transport and Faradaic processes in porous media. The latter models are used for simulation of electrosorption processes in porous media.

42 ENGINEERING↗

One- and Two-Equation Models to Simulate Ion Transport in Charged Porous Electrodes

Energy storage in porous capacitor materials, capacitive deionization (CDI) for water desalination, capacitive energy generation, geophysical applications, and removal of heavy ions from wastewater streams are some examples of processes where understanding of ionic transport processes in charged porous media is very important. In this work, one- and two-equation models are derived to simulate ionic transport processes in heterogeneous porous media comprising two different pore sizes. It is based on a theory for capacitive charging by ideally polarizable porous electrodes without Faradaic reactions or specific adsorption of ions. A two-step volume averaging technique is used to derive the averaged transport equations for multi-ionic systems without any further assumptions, such as thin electrical double layers or Donnan equilibrium. A comparison between both models is presented. The effective transport parameters for isotropic porous media are calculated by solving the corresponding closure problems. An approximate analytical procedure is proposed to solve the closure problems. Numerical and theoretical calculations show that the approximate analytical procedure yields adequate solutions. Lastly, a theoretical analysis shows that the value of interphase pseudo-transport coefficients determines which model to use.

25 ENERGY STORAGE↗

High Ion-Accessible Surface Area CNT-Ultracapacitors for Groundwater Desalination

Fresh water is a vital resource for human survival, as well as a key component for a wide range of industrial and agricultural needs. However, only 0.65% of the world’s water resources are available as fresh water, and the demand on the world’s water reserves continues to rise, with the demand already beginning to outpace the supply in many areas. A water-energy nexus is being reached that requires low -cost and -energy solutions for various degrees of treated water. Public awareness of the problem has also risen, such that in a 2012 survey, 88% of Americans reported concerns about potential water shortages. Approximately two-thirds of the world’s population could suffer water shortages over the next few years. Seawater and other saline water supplies make up around 98% of the world’s accessible water. Properly treated to reduce the levels of salinity, this represents an almost unlimited supply of fresh water. The high energy requirements, capital costs, and maintenance requirements to remove salts and other unwanted compounds, however, are barriers to widespread implementation of salt-to-freshwater facilities. These facilities most commonly use reverse osmosis (RO) systems that suffer from high required pressures and failures of moving parts; additionally, these facilities consume much grid energy and require constant maintenance, leading to high capital and operational costs. The RO process also generates large volumes of highly concentrated bio-hazardous brine that is costly to safely return to the ocean. In contrast to RO, capacitive desalination or capacitive deionization (CDI) has fewer moving parts (a low-pressure pump and several valves), operates at low pressure, and does not generate large quantities of brine that are hazardous to marine life. The capacitive charge/discharge of a CDI system can be cycled almost indefinitely, and the system has low energy requirements because the capacitive discharge electrical current can be co-generated back to the system. RO must remove the water from the salt while CDI removes the salt from the water. This represents a significant difference in the number of molecules which must be moved and energy required to desalinate water. However, CDI has not seen widespread use for large- or small-scale desalination because electrode efficiency has limited the extraction rate below what is useful for most applications. Mainstream demonstrated the following successes during this SBIR program: Performance - We developed an innovative new electrode structure for the high-efficiency removal of ions from salt-contaminated water samples by CDI. Based on prototype electrochemical tests, our CDI consumes as low as 0.71 kW/m 3 of treated water (compared to 2.9 to 3.7 kW/m 3 for RO). Scalability – During Phase II, we increased the electrode size from 3.8 cm 2 single-sided electrodes to 180 cm 2 double-sided electrodes. Using larger acid baths and CVD furnace, we increased electrode fabrication capacity increased by 315 times. Scalable electrochemical CDI stack design and balance of plant – During Phase II, we demonstrated at scalable low-pressure drop stack design and balance of plant for the continuous removal of ions. Corrosion Resistance – Based on accelerated corrosion testing data, our high-quality graphitic electrodes have a significantly improved corrosion resistance. This was 20 times better corrosion resistance than our Phase I electrodes and significantly higher than typical CDI system electrodes. Flexibility –By tuning the pore size of the electrode materials, we demonstrated the removal of key target ionic contaminants, such as sodium chloride, nitrate, and phosphate salts. These ionic contaminants are common in agricultural and industrial wastewater runoff and are difficult to remove by conventional methods, which require excessive use of reagents.

Cox, Dr. Philip↗

Understanding resistances in capacitive deionization devices

The desalination characteristics of capacitive deionization (CDI) are significantly impacted by the cell resistance. Here we apply electrochemical impedance spectroscopy (EIS) to analyze the resistive properties of a CDI device, which include EIS measurements on a complete assembled cell (in two wire mode) and EIS measurements with additional contacts to decouple electrode/electrolyte and contact impedances (four wire mode). These measurements shed light on the interface between current collector and electrode as well as the internal capacitive and resistive elements of the cell. With two-wire and four-wire EIS measurements, we find that the often observed high-frequency arc(s) in the impedance spectra can be due to contact effects and/or an internal ionic-transfer resistance that is locally in parallel with macropore wall capacitance. In some cases, the two associated arcs in the Nyquist plot are overlapping and present simultaneously, making their identification in the EIS spectra difficult unless both two-wire and four-wire measurements are made. Despite causing a large high-frequency arc in the Nyquist plot, we find that the apparent internal ionic-transfer resistance is negligible compared to the resistances of the electrode, separator, and external electronic components. Here, an investigation of the contact impedance between the electrode and current collector reveals a parallel RC arc that can grow over time if an improper material is used (e.g., titanium). In our system, the electrode ionic resistance dominates the total Ohmic power dissipation, which has implications for scale-up of CDI systems and future improvements of cell design.

36 MATERIALS SCIENCE↗

Self similarities in desalination dynamics and performance using capacitive deionization

Charge transfer and mass transport are two underlying mechanisms which are coupled in desalination dynamics using capacitive deionization (CDI). We developed simple reduced-order models based on a mixed reactor volume principle which capture the coupled dynamics of CDI operation using closed-form semi-analytical and analytical solutions. We use the models to identify and explore self-similarities in the dynamics among flow rate, current, and voltage for CDI cell operation including both charging and discharging cycles. The similarity approach identifies the specific combination of cell (e.g. capacitance, resistance) and operational parameters (e.g. flow rate, current) which determine a unique effluent dynamic response. We here demonstrate self-similarity using a conventional flow between CDI (fbCDI) architecture, and we hypothesize that our similarity approach has potential application to a wide range of designs. We performed an experimental study of these dynamics and used well-controlled experiments of CDI cell operation to validate and explore limits of the model. For experiments, we used a CDI cell with five electrode pairs and a standard flow between (electrodes) architecture. Guided by the model, we performed a series of experiments that demonstrate natural response of the CDI system. We also identify cell parameters and operation conditions which lead to self-similar dynamics under a constant current forcing function and perform a series of experiments by varying flowrate, currents, and voltage thresholds to demonstrate self-similarity. Based on this study, we hypothesize that the average differential electric double layer (EDL) efficiency (a measure of ion adsorption rate to EDL charging rate) is mainly dependent on user-defined voltage thresholds, whereas flow efficiency (measure of how well desalinated water is recovered from inside the cell) depends on cell volumes flowed during charging, which is determined by flowrate, current and voltage thresholds. Results of experiments strongly support this hypothesis. Results show that cycle efficiency and salt removal for a given flowrate and current are maximum when average EDL and flow efficiencies are approximately equal. We further explored a range of CC operations with varying flowrates, currents, and voltage thresholds using our similarity variables to highlight trade-offs among salt removal, energy, and throughput performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Brackish water desalination using reverse osmosis and capacitive deionization at the water-energy nexus

Here, we present a critical review of the reported performance of reverse osmosis (RO) and capacitive deionization (CDI) for brackish water (salinity < 5.0 g/L) desalination from the aspects of engineering, energy, economy and environment. We first illustrate the criteria and the key performance indicators to evaluate the performance of brackish water desalination. We then systematically summarize technological information of RO and CDI, focusing on the effect of key parameters on desalination performance, as well as energy-water efficiency, economic costs and environmental impacts (including carbon footprint). We provide in-depth discussion on the interconnectivity between desalination and energy, and the trade-off between kinetics and energetics for RO and CDI as critical factors for comparison. We also critique the results of technical-economic assessment for RO and CDI plants in the context of large-scale deployment, with focus on lifetime-oriented consideration to total costs, balance between energy efficiency and clean water production, and pretreatment/post-treatment requirements. Finally, we illustrate the challenges and opportunities for future brackish water desalination, including hybridization for energy-efficient brackish water desalination, co-removal of specific components in brackish water, and sustainable brine management with innovative utilization. Our study reveals that both RO and CDI should play important roles in water reclamation and resource recovery from brackish water, especially for inland cities or rural regions.

42 ENGINEERING↗

A Review: Flow Electrode Capacitive Deionization for Improved Electrochemical Water Desalination

In many places of the world people have continued to suffer from major droughts and water shortages. With climate change climbing in intensity, these dry conditions will only worsen. With much of the world’s water in the ocean, both saltwater and brackish water have been identified as key water sources. Currently, there are several technologies available for water desalination and treatment such as reverse osmosis, capacitive deionization, electrodialysis, and flow electrode capacitive deionization. This paper will briefly review each of these technologies and propose a new design to improve the current flow electrode capacitive deionization architecture. The new design uses a current collector flow-electrode architecture that has the potential to achieve record thermodynamic energy efficiencies. This formulation is proprietary to Lawrence Livermore National Laboratory.

36 MATERIALS SCIENCE↗

High water recovery and improved thermodynamic efficiency for capacitive deionization using variable flowrate operation

Water recovery is a measure of the amount of treated water produced relative to the total amount of water processed through the system, and is an important performance metric for any desalination method. Conventional operating methods for desalination using capacitive deionization (CDI) have so far limited water recovery to be about 50%. To improve water recovery for CDI, we introduce a new operating scheme based on a variable (in time) flow rate wherein a low flow rate during discharge is used to produce a brine volume which is significantly less than the volume of diluent produced. We demonstrate experimentally and study systematically this novel variable flowrate operating scheme in the framework of both constant current and constant voltage charge-discharge modes. We show that the variable flowrate operation can increase water recovery for CDI to very high values of ~90% and can improve thermodynamic efficiency by about 2- to 3-fold compared to conventional constant flowrate operation. Importantly, this is achieved with minimal performance reductions in salt removal, energy consumption, and volume throughput. Our work highlights that water recovery can be readily improved for CDI at very minimal additional cost using simple flow control schemes.

42 ENGINEERING↗

Energy recovery in capacitive deionization systems with inverted operation characteristics

Capacitive deionization (CDI) operated under inverted mode involves electronic charging and discharge steps with corresponding ion concentration and desalting coupled with simultaneous energy storage. In this work, an energy recovery system derived from a Cuk dc–dc converter is explored to transfer the energy stored from one inverted capacitive deionization (i-CDI) cell during the electronic discharge step to another during the charge step, decreasing the overall energy requirement for capacitive water desalination. The i-CDI cell, a subset of CDI architecture operated in an inverted mode, is improved by incorporating ion-selective membranes to allow inverted membrane capacitive deionization (i-MCDI), leading to enhanced charge storage achieved with reduced energy input. For example, in comparison to i-CDI that requires ~12 J g -1 of energy input, the i-MCDI cell requires only 8 J g -1 . By incorporating the recovery system, the energy penalty can be reduced to only require ~8 and 4 J g -1 for i-CDI and i-MCDI cells, respectively. Improvement in energy recovery was shown to be achieved by reducing charge leakage, with the i-MCDI cell showing up to 3 times the leakage resistance of the i-CDI cell.

54 ENVIRONMENTAL SCIENCES↗

Electrically regenerated ion-exchange technology: Leveraging faradaic reactions and assessing the effect of co-ion sorption

Capacitive deionization (CDI) technologies have the potential to become cost-competitive alternatives to reverse osmosis for the treatment of brackish waters. In this study, we describe our findings on the effect of co-ion sorption and faradaic side reactions on our ion exchange resin functionalized desalination electrodes which passively capture salt and reject it upon charging. This system, which we previously reported on and refer to as electrically regenerated ion exchange (ERI), avoids the use of expensive ion exchange membranes in an effort to save costs. Surprisingly, we find that, compared to a reference CDI system, ERI electrodes capture salt most effectively at low applied voltages (0.5 mg/cm 3 at 0.8 V). Both CDI and ERI systems also seem to suffer from co-ion sorption effects which negatively impact salt adsorption. However, Faradaic side reactions at higher voltages (1 V and 1.2 V) which we track via pH measurements, serve as a detriment to CDI but seem to facilitate the functionality of ERI.

42 ENGINEERING↗

Seawater desalination by over-potential membrane capacitive deionization: Opportunities and hurdles

The salt removal capacity ( SRC ) of the carbon electrodes in membrane capacitive deionization (MCDI) is limited by the applied potential (<1.6 V). Thus, enhancement of the SRC is essential before applying MCDI to seawater desalination. This study aims at developing a novel MCDI system for seawater desalination by applying over-potential (OP) to enhance ion-adsorption capacity and kinetics, and by reversing the polarity (RP) of electrodes to improve ion-desorption kinetics (hereafter named OP-MCDI-RP) for seawater desalination. At 2.4 V, the OP-MCDI system with mesoporous carbon demonstrated a SRC value of 64.7 mg g –1 when desalting 0.5 M NaCl solution, while the OP-CDI system could only remove 8.2 mg g –1 under identical conditions. Similarly, an OP-MCDI cell using carbon aerogel demonstrated a greater SRC value of 43.4 mg g –1 in comparison with 12.5 mg g –1 achieved in OP-CDI. These results indicate that the OP-MCDI system can directly desalt high salinity water regardless of the electrode material. In contrast to the OP-MCDI system, the OP-MCDI-RP system yields a higher regeneration efficiency by applying a reversed low-voltage. It is shown that, under appropriate operating conditions, the OP-MCDI-RP system reduced the electrical conductivity of a seawater sample of 37 practical salinity units by 99.9%, suggesting that the OP-MCDI-RP system can be employed for seawater desalination. In conclusion, due to the dramatic increase in energy demand and insufficient long-term stability caused by high potential and high salt concentration, however, the OP-MCDI-RP process should be further investigated for potential practical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Performance Capacitive Deionization via Manganese Oxide-Coated, Vertically Aligned Carbon Nanotubes

Discovering electrode materials with exceptional capacitance, an indicator of the ability of a material to hold charge, is critical for developing capacitive deionization devices for water desalination. Maganese oxides (MnOx) have shown promise as capacitive electrode materials, but they exhibit a tradeoff where higher loading of the active MnOx comes at a cost of lower conductivity. To address this challenge and achieve high salt adsorption, we fabricated electrodes comprising vertically aligned core-shell nanostructures using atomic layer deposition (ALD) to coat thin films of MnOx onto vertically aligned carbon nanotubes (VACNTs). The inherently hierarchical, anisotropic, three-dimensional macroporous structure of VACNTs and the tunable coating, a hallmark of ALD, enabled co-optimization of the hybrid material’s specific capacitance with respect to mass and geometric area. The specific capacitance was optimized in this study to 215 ± 7 F/g and 1.1 ± 0.1 F/cm 2 in 1 M NaCl electrolyte at 5 mV/s scan rate, respectively. This material exhibited remarkable sodium ion adsorption capacity of 489 ± 25 μmol Na /g material (two-fold higher than pristine VACNTs) at a functioning voltage of 1.2 V, which may ultimately enable expanded desalination applications of capacitive deionization.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

System and method for high efficiency electrochemical desalination

The present disclosure relates to a capacitive deionization (CDI) system for desalinating salt water. The system may have a capacitor formed by spaced apart first and second electrodes, which enable a fluid flow containing salt water to pass either between them or through them. An input electrical power source is configured to generate an electrical forcing signal between the two electrodes. The electrical forcing signal represents a periodic signal including at least one of voltage or current, and which can be represented as a Fourier series. One component of the Fourier series is a constant, and a second component of the Fourier series is a sinusoidal wave of non-zero frequency which has the highest amplitude of the additive components of the Fourier series. The amplitude of the sinusoidal wave component is between 0.85 and 1.25 times the amplitude of the periodic signal.