Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacity value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Influence of Hybridization on the Capacity Value of PV and Battery Resources

Utility-scale systems that combine solar photovoltaic and battery (PV+battery) technologies are growing in popularity on the U.S. bulk power system. The business case for PV+battery systems depends on both their ability to reduce costs and their ability to generate value synergies associated with the provision of energy, capacity, and ancillary services. Capacity value can constitute a significant portion of the value PV+battery hybrids provide to the grid (e.g., through avoided or deferred capacity) and receive through revenues. Throughout this report, we define capacity value as the monetary value of a plant's contribution towards the planning reserve margin, which ultimately depends on market rules and structures. PV+battery hybrids do not always fit into current market structures because of the interactions between the PV and battery components. Unique considerations for the capacity value of PV+battery hybrids include the disparate nature of participation models for PV and battery technologies in existing market rules and the potential influence of a shared interconnection capacity; limitations imposed by a shared inverter; limited ability to charge the battery in advance of capacity events if charging must be sourced from the coupled PV; and challenges or uncertainties associated with co-optimizing the operations of the PV and battery components. Grid operators are currently considering how market structures can be modified to optimally determine the capacity value provided by PV+battery systems, and the rules of how they are integrated into markets are still being written. As with any resource, poorly designed rules could increase the cost of energy and reduce system reliability, while well-designed rules could allow markets to receive the full benefits hybrid systems can offer without overcompensating them for the services they provide. Well-designed rules for PV+battery systems must consider the unique aspects listed above, while leveraging the commonalities with existing resource types. In this report, we summarize the technical capability and market rules that influence the capacity value of PV+battery systems. We further discuss the potential tradeoffs between computational complexity and accuracy for the various ways in which grid operators can credit PV+battery systems for capacity. Finally, we describe markets for capacity, survey current wholesale market rules applying to PV+battery systems, and provide a snapshot of the current regulatory landscape for PV+battery systems.

14 SOLAR ENERGY↗

Additional Capacity Value From Synergy of Variable Renewable Energy and Energy Storage

Current capacity markets often consider capacity credits from each resource independently, irrespective of the portfolio of resources, potentially overvaluing or undervaluing the capacity contribution of variable renewable energy (VRE) and energy storage (ES) in the grid. We propose a method for calculating the standalone and integrated capacity value of an added VRE resource with existing ES resources. The difference between the integrated and standalone value is the portfolio effect. This is the additional capacity value gained by the synergy of VRE and the existing fleet. Using chronological dispatch simulations and two different reliability metrics to estimate firm capacity, we demonstrate on a small test system that the portfolio effect can be substantial.

capacity credit↗

Modeling and Analysis of Clean Energy and Storage Technologies (CRADA Final Report, Project 1)

The goal of this project is to provide Southern Company Services, Inc. ("Participant") with custom scripts that can be used to create an average PV energy production profile, calculate lifetime energy value, calculate capacity value, and calculate the resultant financial metrics considering those value streams. Secondly, a fuel-cell model will be added to the public version of System Advisor Model (SAM). This standalone technology will incorporate PV and battery storage, allowing the participant to model the interaction of these three technologies. By adding this capability to a public version of SAM, a broad audience will be able to consider the system performance and financial benefits of installing a fuel cell as a baseline generator with PV. Thirdly, automated dispatch algorithms will be developed and added to SAM. These algorithms will enable Southern Company to dispatch a DC-connected front-of-the-meter battery system while considering price signals and PV clipping behavior. By adding these capabilities to a public version of SAM, users will be able to consider more complex and realistic ways of dispatching a battery system.

14 SOLAR ENERGY↗

Market analysis for the integration of new power technologies: A case study of the deployment of hybrid fossil-based generator plus energy storage (ES-FE)

This study examines the national landscape of hybridized fossil energy (FE) power plants with energy storage (ES) technologies (“ES-FE”) and presents the compilation of an ES-FE dataset, which includes over 65 ES-FE projects and concepts in the United States, comprising approximately 500 MWh of co-located ES capacity with FE power plants. This study also estimates the economic feasibility of adding ES to existing FE power plants by characterizing the potential revenues that can be generated by the ES component through flexibility and capacity value. The analysis focuses on ES technologies with 2- to 10-h. durations located in four U.S. independent system operators (ISOs): Midcontinent ISO (MISO), Electric Reliability Council of Texas (ERCOT), PJM Interconnection (PJM), and California ISO (CAISO), which have +70,000 MW of combined FE power capacity that could add ES. Annual revenues are estimated for the ES component using a what-if-analysis approach, for capacity value, price arbitrage, or ancillary services provision. The results show that annual revenues depend on the end-use storage service, wholesale electricity and capacity market prices, and ES technology operation parameters such as discharging duration and cycling frequency. When performing a sensitivity analysis, ES accrues $7–178/kW-yr. via price arbitrage and ancillary services provision in the four ISOs, and $13–92/kW-yr. when providing capacity value only in MISO and PJM. A cash flow analysis is performed to estimate the net present value (NPV) of the ES addition using a range of ES costs. The study finds that for most ES technologies considered, these revenues alone are insufficient to achieve economic feasibility. In conclusion, of the 1645 total runs analyzed, 115 had positive NPVs (7%). Therefore, other revenue streams or monetizable benefits are necessary to achieve the break-even point.

20 FOSSIL-FUELED POWER PLANTS↗

Highly swollen ROMP-based gels

In this study, the leakage of organic solvent during the transportation and storage is one of the major threats to the environment. Networks/gels acting as the absorbing materials for organic solvents are the most promising solution for the organic solvent pollution. Here, we report the synthesis of highly swollen networks/gels in high yield (≥95%) via ring opening metathesis polymerization (ROMP) using Grubbs’ first generation catalyst/initiator (G1), a crosslinker (1,1'-(methylenedi-4,1-phenylene)bis-exo-7-oxanorbornenecarboximide) and monofunctional monomer/diluent (exo-N-phenyl-7-oxanorbornenecarboximide). The mesh size of the network was varied by keeping the concentration of monomer constant while changing the concentrations of crosslinker and G1 (initiator). The swelling capacity of the network in N,N-dimethylformamide (DMF) solvent increased from 41 to 53 and to 61 with the increase of theoretical mesh size (molar ratio of monomer to crosslinker) from 20 to 40 and to 60, respectively. By further increasing the mesh size from 60 to 80 there was no significant change in swelling capacities (63). Thus, the gel with the mesh size of 60 was selected for swelling capacity analysis in other polar organic solvents such as dimethyl sulfoxide (DMSO), dichloromethane (DCM), chloroform and lithium-ion battery electrolyte solution (1.0 M LiPF 6 in ethylene carbonate (EC)/diethyl carbonate (DEC) = 50/50 (v/v)). They showed the decreased swelling capacity value from 61 to 57, 40, 31 and 5, respectively. For a controlled mesh size ROMP-based gel, we observed the highest swelling capacity values to date.

36 MATERIALS SCIENCE↗

Renewable-battery hybrid power plants in congested electricity markets: Implications for plant configuration

Examining coupled renewable-battery power plants (“hybrids”) in congested areas provides insights into a future of increased wind and solar penetration. Our study focuses on two types of congested regions, Variable Renewable Energy (VRE)-rich Areas and Load Centers, and explores likely plant configuration choices for developers and transmission network planners. Here, this paper examines how hybrid value, comprising energy and capacity value, varies by plant configuration and congested region type considering factors such as storage duration, battery degradation, and ability to charge from the grid. We select plant locations from across the seven main U.S. independent system operators (ISOs). Hybrid value for each configuration is computed based on profit-maximizing plant operation given perfect foresight, according to observed wholesale power market real time prices from 2018 to 2021. In VRE-rich Areas, the median increase in energy value from extending storage duration from one to 4h is 29.4% for solar and 26.8% for wind, assuming low battery degradation costs and storage sized to 100% of the plant's nameplate generation capacity. Increasing storage duration beyond 4h does not substantially increase its value from energy markets, even in VRE-rich Areas. We find that solar hybrids reach a 90% capacity credit with 4h of storage, while wind hybrids require 8h of storage, based on the capacity factor of each hybrid during the top 100 net load hours.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Average and Marginal Capacity Credit Values of Renewable Energy and Battery Storage in the United States Power System

As deployment of renewable resources and storage continue to significantly grow in the coming decades, these technologies will play increasingly important roles in maintaining power systems' resource adequacy. Few analyses so far offer comprehensive comparisons of forward-looking average and marginal capacity credits of variable renewable energy and storage in the U.S. interconnections across a wide range of possible futures. To fill this research gap, we quantify the average and marginal capacity credits of solar PV, onshore and offshore wind, and batteries between 2026 and 2050 across the U.S power systems to examine the temporal trends, spatial patterns, and trade-offs between these two capacity accreditation approaches. Across technologies, capacity credits of solar PV most clearly follow downward trends over time, reflecting the significant rise in solar PV generation share as the grid decarbonizes. While battery storages' generation shares also rise significantly over time, their capacity credits always remain stably high due to their capabilities to be dispatched strategically during critical periods to maintain reliability. On the other hand, capacity credits of wind technologies in general follow slight upward trends as their generation shares level off. There are strong spatial variabilities of both average and marginal capacity credits across technologies, but capacity credits of solar PV displaying the most obvious spatial patterns with high capacity credits concentrating in wind-rich, solar-poor regions in SPP, PJM, and MISO, suggesting potential reliability benefits of interconnection-wide planning for renewable energy deployments. Additionally, except for offshore wind, average capacity credits of all other renewable technologies tend to be higher than their marginal capacity credits, indicating that existing renewable resources tend to be accredited higher than new resources at almost any time.

25 ENERGY STORAGE↗

Batteries Included: Top 10 Findings from Berkeley Lab Research on the Growth of Hybrid Power Plants in the United States

One of the most important electric power system trends of the 2010s was the rapid deployment of wind turbines and photovoltaic arrays, but a twist for the 2020s may be the rapid deployment of ‘hybrid’ generation resources. Hybrid power plants typically combine solar or wind (or other energy sources) with co-located storage. While hybridization helps to ease the challenge of balancing variable supply and demand, its relative novelty means that research is needed to facilitate integration and promote innovation. Combining the characteristics of multiple energy, storage, and conversion technologies poses complex questions for grid operations and economics. Project developers, system operators, planners, and regulators would benefit from better data, methods, and tools to estimate the costs, values, and system impacts of hybrid projects. This publication showcases some of Berkeley Lab’s robust research program intended to support private- and public-sector decision-making about hybrid plants in the United States. Our short briefing summarizes articles that we published between 2020 and 2022, links to the in-depth reports, and provides contact details for further engagement on the specific research topics: Growth: Developer interest in hybrid power plants is strong and growing Price vs. Value: PV+storage hybrids have low PPA prices and high value in some regions Market Drivers: Solar hybridization is driven by tax credits and other benefits Configuration Choices: Market prices have incentivized shorter duration batteries with PV Capacity Value: The capacity contribution of a hybrid is less than the sum of its parts Ancillary Services: AS markets are a valuable yet fleeting option for hybrids Market Participation: Hybrids can more flexibly engage with electricity markets Operations: The power system value of hybrids depends on how they are operated Distributed Hybrids: Growth of customer-sited PV+storage hybrids offers new opportunities Future Research: Where next? Priority areas for hybrid power research.

25 ENERGY STORAGE↗

Exploring the design space of PV-plus-battery system configurations under evolving grid conditions

In this study, we explore how the energy and capacity values of coupled systems comprising solar photovoltaic arrays and battery storage (PV-plus-battery systems) could evolve over time based on the evolution of the bulk power system. Using a price-taker model with simulated hourly energy and capacity prices projected from the present to 2050, we simulate the revenue-maximizing dispatch of a range of DC-coupled PV-plus-battery configurations in three locations in the United States. These configurations are defined by the inverter loading ratio (ILR, the ratio of the PV array capacity to the inverter capacity, which we vary from 1.4 to 2.6) and the battery-inverter ratio (BIR, the ratio of the battery power capacity to the inverter capacity, which we vary from 0.25 to 1.0). Based on each configuration's total value, we estimate the breakeven costs needed to justify each incremental increase in ILR (holding BIR constant) or BIR (holding ILR constant). We find that, in a future with low-cost renewable energy technologies, PV-plus-battery system ILRs can be economically increased to around 2.0-2.4 at a BIR of 1.0, depending on solar resource. Our results indicate that a likely evolution of PV-plus-battery system design will be increasingly greater battery power capacity to mitigate the declining PV capacity value, which will, in turn, enable increasingly higher ILRs to further increase energy value. The extent to which PV-plus-systems will be deployed with increasingly higher ILRs depends primarily on whether PV cost declines outpace declining value and increasing curtailment over time.

14 SOLAR ENERGY↗

Quantifying Uncertainties in Heat Capacity Measurements of Molten Salts Determined Using Differential Scanning Calorimetry

Uncertainty in specific heat capacity values of a molten salt determined by using differential scanning calorimetry (DSC) was assessed based on the precision of replicate measurements of heat flows used in the calculation and effects of corrections that are commonly made to heat flow measurements. The ratio method of determining heat capacity was applied using the results of replicate heat flow measurements made with two empty cells, a sapphire reference material, and three samples of a doped NaCl-UCl 3 salt mixture. Replicate measurements with empty cells were used to quantify the effects of system instabilities and sensitivities on the measured heat flows of sapphire and salt. The combined effects of uncertainties in individual heat flow measurements made with blank cells using this system were quantified to be 2.6 μV based on isothermal holds before and after the scan, with cell placement adding the greatest uncertainty. This value was used as the tolerance for accepting background-corrected heat flows measured with sapphire and salt to calculate the specific heat capacity. The acceptable heat flows measured for sapphire and salt over the temperature range of 540 to 725 °C resulted in calculated specific heat capacity values ranging from 0.53 to 0.91 J g −1 K −1 with an overall average value of 0.70 J g −1 K −1 and an uncertainty of 0.22 J g −1 K −1 at the 99 % confidence level. The combined uncertainty in the specific heat capacity masked detection of any effect of temperature or salt composition that occurred.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Energy storage system

A system, a method, and a computer program product for providing heterogeneous unifying battery storage. A state-of-health value of a battery is determined. The state-of-health value of the battery is less than an original capacity value of the battery. The battery is connected to an electrical power source for re-conditioning. A target state-of-health value for the battery and a number of cycles required to achieve the target state-of-health value of the battery are determined. Each cycle in the number of cycles includes at least one of: a charging the battery and a discharging the battery. The battery is re-conditioned by cycling the battery using the determined number of cycles. Cycling includes drawing electrical power from the electrical power source.

Tong, Shijie↗

Impact of neutron irradiation on the thermophysical properties of additively manufactured stainless steel and inconel

The deployment of additive manufacturing (AM) technologies to support the nuclear energy industry is limited by the current lack of data related to the irradiation performance of AM parts. The Colorado School of Mines is conducting a multi-year irradiation and post irradiation examination project to study the impacts of neutron irradiation on stainless steel 316L and Inconel 718 and 625 specimens produced by several commercially available AM techniques and irradiated in the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). This paper presents initial results on the impact of neutron irradiation on the heat capacity, the thermal diffusivity, and the thermal conductivity of the specimens at temperatures between 100 oC and 400 oC. The unirradiated AM specimens have heat capacity values similar to, or lower than, the reference values, regardless of manufacturing method or material. The irradiated AM specimens have average heat capacities greater than the unirradiated specimens and reference values in every case. Additionally, the thermal diffusivities of the unirradiated AM specimens are either larger or statistically similar to the reference values. The irradiated AM specimens exhibit lower thermal diffusivities compared to the reference thermal diffusivity values. One of the stainless steel 316L laser powder bed fusion samples exhibited thermal diffusivity values with statistically significant anisotropy prior to and after irradiation. The thermal conductivities of the unirradiated AM stainless steel 316L specimens and the unirradiated Inconel 718 specimens are lower or statistically similar to the reference values. The unirradiated Inconel 625 specimens exhibit slightly higher thermal conductivity values than the reference values. The irradiated specimens show a significant increase in thermal conductivity compared to the unirradiated specimens and the reference values for all materials.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigating capacity credit sensitivity to reliability metrics and computational methodologies

Assigning capacity value to renewable energy sources (RES) is a challenge faced in planning their integration with the grid. The difficulties stem from the natural characteristics of variability and intermittency of wind and solar sources. The capacity credit (CC) analysis evaluates the system’s actual power output compared with a constant capacity generator, i.e., conventional generator and determines an effective capacity to use for planning and operation. Herein this paper presents different factors that could affect the CC of a system. Two methods are proposed to determine the CC, namely equivalent firm capacity (EFC) and effective load carrying capability (ELCC). Since these methods are based on satisfying reliability criteria, daily loss of load expectation (LOLE), hourly loss of load (LOLH), and expected energy not served (EENS) have been employed as indices. To obtain the CC value, both methods apply two techniques: traditional and optimization. Genetic algorithm (GA) is the optimization approach used in this paper. Then, this work compares the two techniques and shows the superior performance of the optimization approach. Two hybrid systems, stand-alone (SA) and grid-connected (GC) modes, are proposed and used as case studies. The hybrid systems consist of photovoltaic (PV), wind turbine (WT), and battery energy storage system (BESS). In this work, three different scenarios are used to compare capacity credit: system as a whole, only wind, and no batteries. Finally, sensitivity analysis is carried out to examine the impact of varying the wind speed, solar irradiation, and load. It is demonstrated that the choice of reliability index plays an important role in determining the capacity credit and it is shown that EENS is a more comprehensive and consistent index of reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing the Electrode Gravimetric Capacity of Li 1.2 Mn 0.4 Ti 0.4 O 2 Cathode Using Interfacial Carbon Deposition and Carbon Nanotube-Mediated Electrical Percolation

Mn-based cation disordered rocksalt oxides (Mn-DRX) are emerging as promising cathode materials for next-generation Li-ion batteries due to their high specific capacities and cobalt and nickel free characteristic. However, to reach the theoretical capacity, solid-state method synthesized Mn-DRX materials require activation via post-synthetic ball milling, typically incorporating more than 20 wt.% conductive carbon that adversely reduces the electrode level gravimetric capacity. To solve this issue, we firstly deposit amorphous carbon on the surface of the Li 1.2 Mn 0.4 Ti 0.4 O 2 (LMTO) particles to increase the electrical conductivity by a five order of magnitude. Although the cathode material gravimetric first charge capacity reaches 180 mAh/g, its highly irreversible behavior leads to a 70 mAh/g first discharge capacity. Subsequently, to ensure a good electrical percolation network, the LMTO material is ball milled with multi-wall carbon nanotube (CNT) to obtain a 78.7 wt.% LMTO active material loading in the cathode electrode (LMTO-CNT). As a result, a 210 mAh/g cathode electrode gravimetric first charge and 165 mAh/g first discharge capacity are obtained, compared to the respective capacity values of 222 mAh/g and 155 mAh/g for the LMTO ball milled with 20 wt.% SuperP C65 electrode (LMTO-SP). After 50 cycles, the LMTO-CNT delivers a 121 mAh/g electrode gravimetric discharge capacity, largely outperforming the 44 mAh/g value of the LMTO-SP. In conclusion, our study demonstrates that while ball milling is necessary to achieve the theoretical capacity of LMTO, a careful selection of the additive, such as CNT, effectively reduces the required carbon quantity to achieve a higher electrode gravimetric discharge capacity.

25 ENERGY STORAGE↗

Toward Addressing the Challenge to Predict the Heat Capacities of RDX and HMX Energetic Materials

Availability of heat capacity as function of pressure and temperature is an essential prerequisite for development of a computational multiscale strategy capable to address the evolution of microstructure and energy release in advanced high energy density materials. In the case of 1,3,5-trinitro-1,3,5-triazinane (RDX) and 1,3,5,7-tetranitro-1,3,5,7-tetrazocane (HMX) systems as two of the most studied energetic materials, there are substantial gaps in experimental data, with available heat capacities values distributed only in a region close to standard ambient conditions. In this study we demonstrate how these major experimental limitations can be addressed in the case of the RDX and HMX systems based on the combined use of classical and quantum mechanical calculations. We show that by considering ideal gas properties evaluated using quantum mechanical methods, and residual properties obtained from molecular simulations using fully flexible atomistic force field models, excellent agreement can be obtained for the predicted heat capacities to the most recent experimental values. An important advantage of the current computational methodology is that it allows evaluation of both constant-volume and constant-pressure heat capacities for a broad interval of temperatures and pressures, which encompasses solid and liquid phases conditions. In the case of the solid α and γ phases of RDX and the β phase of HMX, the predicted results follow closely both the available experimental data at standard ambient conditions and the results obtained using density functional theory calculations at high pressures, a regime where experimental data are not available. A perspective to expand the current methodology is also discussed.

36 MATERIALS SCIENCE↗

Utility-Scale Solar, 2024 Edition: Empirical Trends in Deployment, Technology, Cost, Performance, PPA Pricing, and Value in the United States [Slides]

Berkeley Lab’s “Utility-Scale Solar, 2024 Edition” presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC (PV plants of 5 MWAC or less, including residential rooftop systems, are covered separately in Berkeley Lab’s companion annual report, Tracking the Sun). Key findings from this year’s report include: -18.5 GWAC of new utility-scale PV capacity came online in 2023, bringing cumulative installed capacity to more than 80.2 GWAC across 47 states. Installed costs continued to fall in 2023. Relative to 2022, capacity-weighted averages decreased by 8% to -$\$1.43$/WAC (or $\$1.08$/WDC). Costs, based on a 7.1 GWAC sample of 76 plants completed in 2023, have fallen by 75% (averaging 10% annually) since 2010. Plant-level capacity factors vary widely, from 6% to 36% (on an AC basis), with a sample median of 24%. -Levelized cost of energy (LCOE) of new 2023 projects increased slightly to $\$46$/MWh prior to the application of tax credits but continued to fall to $\$31$/MWh when accounting for federal incentives. PPA prices have largely followed the decline in solar’s LCOE over time, but newly signed longer-term PPA prices have increased since 2021, to an average of $\$35$/MWh (levelized, in 2023 dollars). -Solar’s average energy and capacity value (i.e., ability to offset costs of other power generation sources) across the U.S. was $\$45$/MWh in 2023. Solar’s average market value was lowest in CAISO ($\$27$/MWh), the market with the greatest solar generation share, and highest in ERCOT ($\$67$/MWh). -Newer solar projects had greater market value in 2023 than their generation costs, yielding $\$1.1$ billion in benefits. Projects built in 2022 delivered on average $\$15$/MWh more market value than their costs in 2023. -Solar’s combined value from wholesale electricity markets, public health and climate damage reduction were greater than generation costs and incentives, yielding $\$13.7$ billion in net benefits in 2023. We estimate U.S. health benefits of $\$24$/MWh and reduced global climate damages of $\$101$/MWh. -Adding battery storage is one way to increase the value of solar. Deployment of 52 new PV+battery hybrid plants set a record with 5.3 GW installed in 2023. Our public data file tracks metadata and PPA prices from more than 100 PV+battery hybrid projects that are already online or that have secured offtake arrangements. -Looking ahead, a massive pipeline of at least 1,085 GW of solar capacity dominates the nation’s interconnection queues at the end of 2023. Nearly 571 GW, or 53%, of that total was paired with a battery – in CAISO it was a staggering 98%. Historically only 10% of the requested solar capacity is built. -For more information, and to explore related interactive data visualizations, go to utilityscalesolar.lbl.gov.

14 SOLAR ENERGY↗

Hybrid renewable energy systems: the value of storage as a function of PV-wind variability

As shares of variable renewable energy (VRE) on the electric grid increase, sources of grid flexibility will become increasingly important for maintaining the reliability and affordability of electricity supply. Lithium-ion battery energy storage has been identified as an important and cost-effective source of flexibility, both by itself and when coupled with VRE technologies like solar photovoltaics (PV) and wind. In this study, we explored the current and future value of utility-scale hybrid energy systems comprising PV, wind, and lithium-ion battery technologies (PV-wind-battery systems). Using a price-taker model with simulated hourly energy and capacity prices, we simulated the revenue-maximizing dispatch of a range of PV-wind-battery configurations across Texas, from the present through 2050. Holding PV capacity and point-of-interconnection capacity constant, we modeled configurations with varying wind-to-PV capacity ratios and battery-to-PV capacity ratios. We found that coupling PV, wind, and battery technologies allows for more effective utilization of interconnection capacity by increasing capacity factors to 60%–80%+ and capacity credits to close to 100%, depending on battery capacity. We also compared the energy and capacity values of PV-wind and PV-wind-battery systems to the corresponding stability coefficient metric, which describes the location-and configuration-specific complementarity of PV and wind resources. Our results show that the stability coefficient effectively predicts the configuration-location combinations in which a smaller battery component can provide comparable economic performance in a PV-wind-battery system (compared to a PV-battery system). These PV-wind-battery hybrids can help integrate more VRE by providing smoother, more predictable generation and greater flexibility.

14 SOLAR ENERGY↗