Search NASA⌕ Search

SEARCH · Search NASA

Results for “capillary discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Demonstration of a high repetition rate capillary discharge waveguide

A hydrogen-filled capillary discharge waveguide operating at kHz repetition rates is presented for parameters relevant to laser plasma acceleration (LPA). The discharge current pulse was optimized for erosion mitigation with laser guiding experiments and MHD simulation. Heat flow simulations and measurements showed modest temperature rise at the capillary wall due to the average heat load at kHz repetition rates with water-cooled capillaries, which is promising for applications of LPAs such as high average power radiation sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Creation of an axially uniform plasma channel in a laser-assisted capillary discharge

Dissipative capillary discharges form plasma channels which allow for high power laser guiding, enabling efficient electron acceleration in a laser wakefield accelerator. However, at the low plasma densities required to produce high-energy electrons, in order to avoid capillary wall damage, high power lasers need a tighter transverse confinement that cannot be achieved by the capillary discharge powered by Ohmic heating alone. The introduction of an additional laser for heating of the plasma leads to deeper and narrower plasma channels. Here we investigate the formation of laser-heated axially uniform plasma channels. Here, we show that a high degree of longitudinal uniformity can be achieved despite significant evolution of the heater laser during its propagation through the channel.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Petawatt Laser Guiding and Electron Beam Acceleration to 8 GeV in a Laser-Heated Capillary Discharge Waveguide.

Guiding of relativistically intense laser pulses with peak power of 0.85 PW over 15 diffraction lengths was demonstrated by increasing the focusing strength of a capillary discharge waveguide using laser inverse bremsstrahlung heating. This allowed for the production of electron beams with quasimonoenergetic peaks up to 7.8 GeV, double the energy that was previously demonstrated. Charge was 5 pC at 7.8 GeV and up to 62 pC in 6 GeV peaks, and typical beam divergence was 0.2 mrad.

Gonsalves, AJ↗

Radial density profile and stability of capillary discharge plasma waveguides of lengths up to 40 cm

We measured the parameter reproducibility and radial electron density profile of capillary discharge waveguides with diameters of 650 μm to 2 mm and lengths of 9 to 40 cm. To the best of the authors’ knowledge, 40 cm is the longest discharge capillary plasma waveguide to date. This length is important for ≥10 GeV electron energy gain in a single laser-driven plasma wakefield acceleration stage. Evaluation of waveguide parameter variations showed that their focusing strength was stable and reproducible to <0.2% and their average on-axis plasma electron density to <1%. These variations explain only a small fraction of laser-driven plasma wakefield acceleration electron bunch variations observed in experiments to date. Measurements of laser pulse centroid oscillations revealed that the radial channel profile rises faster than parabolic and is in excellent agreement with magnetohydrodynamic simulation results. We show that the effects of non-parabolic contributions on Gaussian pulse propagation were negligible when the pulse was approximately matched to the channel. However, they affected pulse propagation for a non-matched configuration in which the waveguide was used as a plasma telescope to change the focused laser pulse spot size.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Density Tailored Capillary Discharge (Final Technical Report)

This final report describes efforts to validate a novel way to drive capillary discharges in order to achieve true matched guiding of a focused laser beam traveling along the capillary. Achieving such matched guiding is important for laser plasma accelerators, such as ones based upon laser wakefield acceleration. During this Phase II program, a computer model, which was specifically designed to predict the time-dependent behavior of the capillary discharge, was exercised to determine whether unconventional ways to drive the discharge may yield matched guiding. A custom power supply was built to drive the capillary discharge in the unconventional manner specified by the model. Experiments performed at STI Optronics seemed to support the predictions of this model; however, subsequent more accurate measurements performed at Lawrence Berkeley National Laboratory did not agree with the model predictions.

43 PARTICLE ACCELERATORS↗

Guiding of 35 TW laser pulses in ablative capillary discharge waveguides

An ablatively driven capillary discharge plasma waveguide has been used to demonstrate guiding of 30 fs, 35 TW laser pulses over distances up to 3 cm with incident intensity in excess of 4x10{sup 18} W/cm{sup 2}. The plasma density range over which good guiding was observed was 1-3x10{sup 18} cm{sup -3}. The quality of the laser spot at the exit mode was observed to be similar to that at the entrance and the transmitted energy was {approx}25% at input powers of 35 TW. The transmitted laser spectrum typically showed blueshifting due to ionization of carbon and hydrogen atoms in the capillary plasma by the high intensity laser pulse. The low plasma density regime in which these capillaries operate makes these devices attractive for use in single stage electron accelerators to multi-GeV energies driven by petawatt class laser systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-heated capillary discharge plasma waveguides for electron acceleration to 8 GeV

A plasma channel created by the combination of a capillary discharge and inverse Bremsstrahlung laser heating enabled the generation of electron bunches with energy up to 7.8 GeV in a laser-driven plasma accelerator. The capillary discharge created an initial plasma channel and was used to tune the plasma temperature, which optimized laser heating. Although optimized colder initial plasma temperatures reduced the ionization degree, subsequent ionization from the heater pulse created a fully ionized plasma on-axis. The heater pulse duration was chosen to be longer than the hydrodynamic timescale of ≈ 1 ns, such that later temporal slices were more efficiently guided by the channel created by the front of the pulse. Here, simulations are presented which show that this thermal self-guiding of the heater pulse enabled channel formation over 20 cm. The post-heated channel had lower on-axis density and increased focusing strength compared to relying on the discharge alone, which allowed for guiding of relativistically intense laser pulses with a peak power of 0.85 PW and wakefield acceleration over 15 diffraction lengths. Electrons were injected into the wake in multiple buckets and times, leading to several electron bunches with different peak energies. To create single electron bunches with low energy spread, experiments using localized ionization injection inside a capillary discharge waveguide were performed. A single injected bunch with energy 1.6 GeV, charge 38 pC, divergence 1 mrad, and relative energy spread below 2% full-width half-maximum was produced in a 3.3 cm-long capillary discharge waveguide. This development shows promise for mitigation of energy spread and future high efficiency staged acceleration experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-heated capillary discharge waveguides as tunable structures for laser-plasma acceleration

Laser-heated capillary discharge waveguides are novel, low plasma density guiding structures able to guide intense laser pulses over many diffraction lengths and have recently enabled the acceleration of electrons to 7.8 GeV by using a laser-plasma accelerator (LPA). These devices represent an improvement over conventional capillary discharge waveguides, as the channel matched spot size and plasma density can be tuned independently of the capillary radius. This has allowed the guiding of petawatt-scale pulses focused to small spot sizes within large diameter capillaries, preventing laser damage of the capillary structure. High performance channel-guided LPAs require control of matched spot size and density, which experiments and simulations reported here show can be tuned over a wide range via initial discharge and laser parameters. In this paper, measurements of the matched spot size and plasma density in laser-heated capillary discharges are presented, which are found to be in excellent agreement with simulations performed using the MHD code MARPLE. Strategies for optimizing accelerator performance are identified based on these results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of electron transport models on capillary discharge plasmas

Magnetohydrodynamics (MHD) can be used to model capillary discharge waveguides in laser-wakefield accelerators. However, the predictive capability of MHD can suffer due to poor microscopic closure models. Here, we study the impact of electron heating and thermal conduction on the capillary waveguide performance as part of an effort to understand and quantify uncertainties in modeling and designing next-generation plasma accelerators. To do so, we perform two-dimensional high-resolution MHD simulations using an argon-filled capillary discharge waveguide with three different electron transport coefficients models. The models tested include (i) Davies et al., (ii) Spitzer, and (iii) Epperlein–Haines (EH). We found that the EH model overestimates the electron temperature inside the channel by over 20% while predicting a lower azimuthal magnetic field. Furthermore, the Spitzer model, often used in MHD simulations for plasma-based accelerators, predicts a significantly higher electron temperature than the other models suggest.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancement of the EUV emission of a metallic capillary discharge operated with argon ambient gas

In this work, the metallic capillary discharge is operated with two different ambients: air and argon. In the experiments reported here, the chamber is first evacuated to 10{sup −5} mbar. The discharge is initiated by the transient hollow cathode effect generated electron beam, with either air ambient or argon ambient at 10{sup −4} mbar. The bombardment of electron beam at the tip of the stainless steel anode gives rise to a metallic vapor, which is injected into the capillary and initiates the main discharge through the capillary. The EUV emission is measured for different discharge voltages for both conditions and compared. It is found that the metallic capillary discharge with argon ambientis able to produce higher EUV energy compared to that with air ambient.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser-heater assisted plasma channel formation in capillary discharge waveguides

A method of creating plasma channels with controllable depth and transverse profile for the guiding of short, high power laser pulses for efficient electron acceleration is proposed. The plasma channel produced by the hydrogen-filled capillary discharge waveguide is modified by a ns-scale laser pulse, which heats the electrons near the capillary axis. This interaction creates a deeper plasma channel within the capillary discharge that evolves on a ns-time scale, allowing laser beams with smaller spot sizes than would otherwise be possible in the unmodified capillary discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

GeV Electron Beams from a Capillary Discharge Guided Laser Plasma Accelerator

Laser plasma acceleration (LPA) up to 1 GeV has been realized at Lawrence Berkeley National Laboratory by using a capillary discharge waveguide. In this paper, the capillary discharge guided LPA system including a broadband single-shot electron spectrometer is described. The spectrometer was designed specifically for LPA experiments and has amomentumacceptance of 0.01 - 1.1 GeV/c with a percent level resolution. Experiments using a 33 mm long, 300 mu m diameter capillary demonstrated the generation of high energy electron beams up to 1 GeV. By de-tuning discharge delay from optimum guiding performance, selftrapping and acceleration were found to be stabilized producing 460 MeV electron beams.

43 PARTICLE ACCELERATORS↗

Effect of Dimensional Changes on Plasma Characteristics in Electrothermal Capillary Discharges for Optimized Performance in Fusion Pellet Injection

Geometrical changes in capillary discharges influence the plasma properties and can control exit parameters to certain desired values. For a fixed capillary radius of 2 mm and a 72-μs 43.9-kA peak discharge current, the plasma temperature is about 2.7 eV for different capillary lengths due to the constant input energy, while the number densities tend to saturate for capillary lengths greater than 12 cm. The electrical conductivity reaches 4.02 × 104 Ω{sup −1} m{sup −1} and then tends to saturate for 9-cm capillary length. The maximum bulk velocity at the capillary exit slightly increases with the increase in the capillary length from 6.15 to 6.26 km/s for lengths below 18 cm and decreases to 5.88 km/s for longer capillaries due to the higher amount of ablated mass and increased drag forces. For a 9-cm length with the same 72-μs 43.9-kA peak discharge current, the increase in the capillary radius reduces the energy density, which in turn reduces the total ablate mass, plasma density, electrical conductivity, and exit pressure. It is shown that the plasma temperature decreases from 4.6 to 2.1 eV by increasing the capillary radius and radiant heat flux also drops from 463 to 18.1 GW/m{sup 2}. The exit bulk velocity drops from 8.7 to 5.3 km/s as the radius increases from 0.5 to 3.6 mm, respectively. The design features of a capillary discharge can be adjusted for the radius and length, to produce specific plasma parameters for desired applications. Scaling laws relating exit peak plasma parameters to radius and length are obtained to facilitate quick estimate of plasma parameters. The validation of this model has been confirmed by confronting with experimental measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Highly efficient pulsed power supply system with a two-stage LC generator and a step-up transformer for fast capillary discharge soft x-ray laser at shorter wavelength

Highly efficient and compact pulsed power supply system for a capillary discharge soft x-ray laser (SXRL) has been developed. The system consists of a 2.2 {mu}F two-stage LC inversion generator, a 2:54 step-up transformer, a 3 nF water capacitor, and a discharge section with a few tens of centimeter length capillary. Adoption of the pulsed transformer in combination with the LC inversion generator enables us to use only one gap switch in the circuit for charging the water capacitor up to about 0.5 MV. Furthermore, step-up ratio of a water capacitor voltage to a LC inversion generator initial charging voltage is about 40 with energy transfer efficiency of about 50%. It also leads to good reproducibility of a capillary discharge which is necessary for lasing a SXRL stably. For the study of the possibility of lasing a SXRL at shorter wavelength in a small laboratory scale, high-density and high-temperature plasma column suitable for the laser can be generated relatively easily with this system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temporal evolution of electron density and temperature in capillary discharge plasmas

Time-resolved spectroscopic measurements of a capillary discharge plasma of helium gas were carried out to obtain detailed information about dynamics of the discharge plasma column, where the fast plasma dynamics is determined by the electron density and temperature. Our measurements show that the electron density of the capillary plasma column increases sharply after gas breakdown and reaches its peak of the order of 10{sup 18} cm{sup -3} within less than 100 ns, and then it decreases as time goes by. The result indicates that a peak electron density of 2.3x10{sup 18} cm{sup -3} occurs about 65 ns after formation of the discharge current, which is ideal for laser wakefield acceleration experiments reported by Karsch et al. [New J. Phys. 9, 415 (2007)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On production and asymmetric focusing of flat electron beams using rectangular capillary discharge plasmas

A method for the asymmetric focusing of electron bunches, based on the active plasma lensing technique is proposed. Our method takes advantage of the strong inhomogeneous magnetic field generated inside the capillary discharge plasma to focus the ultrarelativistic electrons. The plasma and magnetic field parameters inside the capillary discharge are described theoretically and modeled with dissipative magnetohydrodynamic computer simulations enabling analysis of the capillaries of rectangle cross-sections. We could use large aspect ratio rectangular capillaries to transport electron beams with high emittance asymmetries, as well as assist in forming spatially flat electron bunches for final focusing before the interaction point.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characteristics of argon plasma waveguide produced by alumina capillary discharge for short wavelength laser application

We have reported the argon (Ar) plasma waveguide produced in an alumina (Al{sub 2}O{sub 3}) capillary discharge and used to guide ultrashort laser pulses at intensities of the order of 10{sup 16} W/cm{sup 2}. The electron density in the plasma waveguide was measured to be 1x10{sup 18} cm{sup -3}, in agreement with one-dimensional magnetrohydrodynamic (MHD) simulations. The MHD code was also used to evaluate the degree of ionization of argon (Ar) in the preformed plasma waveguide. The maximum ion charge state of Ar{sup 3+} in capillary discharge was measured and obtained in the MHD simulations. The spectrum of the propagated laser pulse in the Ar plasma waveguide was not modified and was well reproduced by a particle-in-cell simulations under initial ion charge state of Ar{sup 3+} in the preformed plasma waveguide. The optimum timing for the laser pulse injection was around 150 ns after initiation of a discharge with a peak current of 200 A.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗