Search NASA⌕ Search

SEARCH · Search NASA

Results for “capillary flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Capillary flow meter for calibrating spinning rotor gauges

This article describes a capillary flow meter whose maximum flow rate of 0.2 {mu}mol/s ({approx}0.2 cm{sup 3}/min at ambient conditions) covers the range that is useful for calibrating spinning rotor gauges. Knowing the input pressure, output pressure, and temperature of the capillary yields the gas flow rate with a relative standard uncertainty as small as 0.04%. The flow meter, which requires no moving parts aside from valves, comprises a ballast tank, a coil of quartz capillary with an inner diameter of 0.1 mm, and a commercial instrumentation package. Measurements near 0.1 {mu}mol/s showed agreement with an independent primary flow meter to within 0.2%, comparable to the combined relative standard uncertainty of 0.11%. Additional measurements showed that operating the capillary flow meter with an exit pressure less than 1 kPa allowed the flow to stabilize within minutes. However, the small exit pressure caused an unexpected enhancement of the slip correction in the hydrodynamic model of the capillary.

42 ENGINEERING↗

Capillary flow in UHPFRC with synthetic fibers, under high tensile stresses

A novel Ultra High-Performance Fiber Reinforced Concrete (UHPFRC) mix with synthetic fibers and a low clinker matrix, henceforth referred to as PE-UHPFRC, has been developed for structural applications. It exhibits a high tensile elastic limit above 7 MPa, a tensile strength of more than 10 MPa, and a very high tensile hardening domain of above 3.5%. In order to effectively use this material, its protective properties have been investigated on the basis of the effect of tensile deformation and subsequent cracking on water transport properties, for a wide range of tensile strain. A special setup was developed to measure the capillary absorption of liquids while the specimen is under tension. The results show a considerable reduction in capillary absorption in case of PE-UHPFRC compared with Strain Hardening Cement-based Composites (SHCC). Moreover, the results highlight the considerable effect of the onset of cracking on capillary absorption.

36 MATERIALS SCIENCE↗

A model and numerical method for compressible flows with capillary effects

A new model for interface problems with capillary effects in compressible fluids is presented together with a specific numerical method to treat capillary flows and pressure waves propagation. This new multiphase model is in agreement with physical principles of conservation and respects the second law of thermodynamics. A new numerical method is also proposed where the global system of equations is split into several submodels. Each submodel is hyperbolic or weakly hyperbolic and can be solved with an adequate numerical method. This method is tested and validated thanks to comparisons with analytical solutions (Laplace law) and with experimental results on droplet breakup induced by a shock wave.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synchrotron x-ray imaging visualization study of capillary-induced flow and critical heat flux on surfaces with engineered micropillars

Over the past several decades, phenomena related to critical heat flux (CHF) on structured surfaces have received a large amount of attention from the research community. The purpose of such research has been to enhance the safety and efficiency of a variety of thermal systems. A number of theories have been put forward to explain the key CHF enhancement mechanisms on structured surfaces. However, these theories have not been confirmed experimentally due to limitations in the available visualization techniques and the complexity of the phenomena. To overcome the limitations of the previous visualization techniques and elucidate the CHF enhancement mechanism on the structured surfaces, we introduce synchrotron X-ray imaging with high spatial (~2 μm) and time (~20,000 Hz) resolutions. Lastly, this technique has enabled us to confirm that capillary-induced flow is the key CHF enhancement mechanism on structured surfaces.

42 ENGINEERING↗

Exploiting the Marangoni Effect To Initiate Instabilities and Direct the Assembly of Liquid Metal Filaments

Utilization of the Marangoni effect in a liquid metal is investigated, focusing on initiating instabilities to direct material assembly via the Rayleigh–Plateau instability. Thin (2 nm) copper (Cu) films are lithographically patterned onto thick (12 nm) nickel (Ni) strips to induce a surface energy gradient at the maximum wavelength of the filament instability predicted by Rayleigh–Plateau instability analysis. We also irradiated the pattern with an 18 ns pulsed laser such that the pattern melts and the resultant Ni–Cu surface tension gradient induces Marangoni flows due to the difference in surface energies. The experimental results, supported by extensive direct numerical simulations, demonstrate that the Marangoni flow exceeds the capillary flow induced by the initial geometry, guiding instabilities such that final nanoparticle location is directed toward the regions of higher surface energy (Ni regions). This work shows a route for manipulation, by means of the Marangoni effect, to direct the evolution of the surface instabilities and the resulting pattern formation.

36 MATERIALS SCIENCE↗

Connecting Pressure-Saturation and Relative Permeability Models to Fracture Properties: The Case of Capillary-Dominated Flow of Supercritical CO 2 and Brine

Fractures are potential pathways for subsurface fluids. In the context of geologic CO 2 sequestration, fractures could threaten the security of reservoirs since they are pathways for leakage. However, the constitutive equations describing the pressure-saturation and relative permeability-saturation, key inputs for flow modeling and prediction, are poorly understood for two-phase fracture flow at the field scale where each fracture might be an element of a complex fracture network or dual-porosity domain. This knowledge is required for the safe storage of CO 2 under potentially fractured caprocks. To address this, we numerically simulated two-phase viscous flow through horizontal heterogeneous fractures across a broad range of roughness and aperture correlation length. The numerical experiments, which solved the modified local cubic law, showed a weak to strong phase interference during the drainage process; that is, supercritical CO 2 displaces brine if the imposed pressure + local viscous force > local capillary force. The drainage process ended when no new brine cells can be further invaded by CO 2 . Afterward, we froze the saturation field for each individual phase and calculated the relative permeability by single-phase flow modeling. Thousands of simulated pressure-saturation and relative permeability curves enabled us to estimate and connect the parameters of the Van-Genuchten model and of the generalized ν-type model to fracture roughness and aperture correlation length. In conclusion, this empirical connection will be useful for assessing and predicting immiscible two-phase flow in horizontal rough fractures at the large scale.

54 ENVIRONMENTAL SCIENCES↗

Experimental investigation of the effect of pore size distribution on nano-particle capture efficiency within ceramic particulate filters

The effect of the pore size distribution on size-resolved filtration efficiency was investigated for two ceramic particulate filters using particulate matter (PM) generated by a spark-ignition direct-injection engine fueled with gasoline. The cordierite filter tested had a porosity of 43%, a median pore diameter (d_50) of 12 µm, and a wide pore size distribution with a lognormal standard deviation (s’) of 0.3. The aluminum titanate filter had very similar porosity, d_50, and thickness, but significantly narrower pore size distribution (s’ = 0.1). The testing of two filters under identical experimental conditions enabled the impact of the pore size distribution on filtration performance to be evaluated. Filtration experiments were performed focusing on just the filter wall, starting from a clean filter until the transition to cake filtration (filtration efficiency > 99%). Time-resolved particle size distribution measurements were used to evaluate the progression of filtration performance and estimate trapped mass within the filter. The aluminum titanate filter, with a narrow pore size distribution, exhibited significantly better diffusion capture efficiency. The negative impact of higher flow velocity on diffusion capture efficiency was more pronounced for a narrower pore size distribution. Flow distributions measured using capillary-flow porometry were used to develop a cylindrical pore flow model to understand the impact of the differences in pore size distribution on observed trends in diffusion capture efficiency within a clean filter. The model helps demonstrate how large pores on the high end of a wider pore size distribution can carry a large fraction of the flow, with less efficient capture of small particles by diffusion. The experimental results and data demonstrate that the bubble point diameter and width of the pore size distribution significantly influence diffusion capture efficiencies for filters with very similar median pore diameter, porosity, and thickness.

aerosol filtration, Aftertreatment, ceramic exhaus↗

Many-body dissipative particle dynamics simulation of liquid/vapor and liquid/solid interactions

The combination of short-range repulsive and long-range attractive forces in Many-body Dissipative Particle Dynamics (MDPD) is examined at a vapor/liquid and liquid/solid interface. Based on the radial distribution of the virial pressure in a drop at equilibrium, a systematic study is carried out to characterize the sensitivity of the surface tension coefficient with respect to the inter-particle interaction parameters. For the first time, this study highlights the approximately cubic dependence of the surface tension coefficient on the bulk density of the fluid. In capillary flow, MDPD solutions are shown to satisfy the condition on the wavelength of an axial disturbance leading to the pinch-off of a cylindrical liquid thread. Correctly, no pinch-off occurs below the cutoff wavelength. MDPD is augmented by a set of bell-shaped weight functions to model interaction with a solid wall. There, hydrophilic and hydrophobic behaviors, including the occurrence of slip in the latter, are reproduced using a modification in the weight function that avoids particle clustering. Finally, the dynamics of droplets entering an inverted Y-shaped fracture junction is correctly captured in simulations parameterized by the Bond number, proving the flexibility of MDPD in modeling interface-dominated flows.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Large scale ZnTe nanostructures on polymer micro patterns via capillary force photolithography

A novel approach to prepare micro patterns ZnTe nanostructures on Si (100) substrate using thermal evaporation is proposed by capillary Force Lithography (CFL) technique on a self-assembled sacrificial Polystyrene mask. Polystyrene thin films on Si substrates are used to fabricate surface micro-relief patterns. ZnTe nanoparticles have been deposited by thermal evaporation method. The deposited ZnTe nanoparticles properties were assessed by Atomic Force Microscope (AFM), Scanning Electron Microscope (SEM). SEM studies indicated that the particles are uniform in size and shape, well dispersed and spherical in shape. This study reports the micro-arrays of ZnTe nanoparticles on a self-assembled sacrificial PS mask using a capillary flow photolithography process which showed excellent, morphological properties which can be used in photovoltaic devices for anti-reflection applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Volumetric cutaneous microangiography of human skin in vivo by VCSEL swept-source optical coherence tomography

We demonstrate volumetric cutaneous microangiography of the human skin in vivo that utilises 1.3-μm high-speed sweptsource optical coherence tomography (SS-OCT). The swept source is based on a micro-electro-mechanical (MEMS)-tunable vertical cavity surface emission laser (VCSEL) that is advantageous in terms of long coherence length over 50 mm and 100 nm spectral bandwidth, which enables the visualisation of microstructures within a few mm from the skin surface. We show that the skin microvasculature can be delineated in 3D SS-OCT images using ultrahigh-sensitive optical microangiography (UHS-OMAG) with a correlation mapping mask, providing a contrast enhanced blood perfusion map with capillary flow sensitivity. 3D microangiograms of a healthy human finger are shown with distinct cutaneous vessel architectures from different dermal layers and even within hypodermis. These findings suggest that the OCT microangiography could be a beneficial biomedical assay to assess cutaneous vascular functions in clinic. (laser biophotonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas Flow in the Capillary of the Atmosphere-to-Vacuum Interface of Mass Spectrometers

Numerical simulations of a gas flow through a capillary being a part of mass spectrometer atmospheric interface were performed using a detailed laminar flow model. The simulated interface consisted of atmospheric and forevacuum volumes connected via a thin capillary. The pressure in the forevacuum volume where the gas was expanding after passing through the capillary was varied in the wide range from 10 to 900 mbar in order to study the volume flow rate as well as the other flow parameters as functions of the pressure drop between the atmospheric and forevacuum volumes. The capillary wall temperature was varied in the range from 24 to 150 °C. Numerical integration of the complete system of Navier-Stokes equations for a viscous compressible gas taking into account the heat transfer was performed using the standard gas dynamic simulation software package ANSYS CFX. The simulation results were compared with experimental measurements of gas flow parameters both performed using our experimental setup and taken from the literature. The simulated volume flow rates through the capillary differed no more than by 10% from the measured ones over the entire pressure and temperatures ranges. A conclusion was drawn that the detailed digital laminar model is able to quantitatively describe the measured gas flow rates through the capillaries under conditions considered. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and Evaluation of a Tethered, Open Port Sampling Interface for Liquid Extraction-Mass Spectrometry Chemical Analysis

Presented in this work is a tethered, liquid-extraction-sampling interface designed for the mass spectrometric surface sampling/analysis of 3D objects. The tethered, open port sampling interface (TOPSI) incorporates a vacuum line between the sampling probe and ionization source, which enables the ability for an extended, tethered sample transfer line. Herein, several designs of the hand-held TOPSI are presented and evaluated on the basis of the analytical metrics of analyte transport time, peak width, and analyte sensitivity. The best analytical metrics were obtained with capillary flow resistances arranged in a particular order and the vacuum region set at 6.2 kPa. This TOPSI design incorporated a transfer capillary 1 m in length, while retaining a fast analyte transport time (12 s), short signal peak width (5 s baseline-to-baseline), and high analyte signal at 90% of that obtained with a regular open port sampling interface (OPSI). The hand-held TOPSI was demonstrated for the characterization of extracted small molecules and metabolites from the surface of mint and rosemary leaves.

47 OTHER INSTRUMENTATION↗

An All Hydrophilic Fluid Diode for Unidirectional Flow in Porous Systems

Abstract A fluid diode that allows fluid flow in one direction but blocks fluid flow in the opposite direction has wide applications including oil recovery, drug delivery, and lab‐on‐a‐chip microfluidics. Many studies are conducted to facilitate directional liquid motion on the solid surface or across thin porous layers. However, the self‐driven one‐way flow inside porous systems still remains a significant challenge. Here, a novel all‐hydrophilic fluid diode (AHFD) made of porous materials with asymmetric pores is reported, which allows capillary flow in a chosen direction. The direction‐dependent flow process and the breakthrough pressure are experimentally and theoretically examined. The proposed AHFD can have many potential applications such as functional protective clothing, microfluidic valve, and oil–water separator, and the idea can be extended to develop other all lyophilic fluid diodes such as oleophilic diode.

Shou, Dahua↗

Lithium Divertor Targets and Walls for the ASTER Liquid Stellarator Reactor, Distributed Divertor

Stellarators may have advantages for certain liquid metal options as Plasma Facing Components (PFC) for divertor targets and first walls due to the wide range of possible magnetic configurations, which additionally are free of disruptions and fast field variations. In a previous work (V. Queral et al., IEEE Trans. Plasma Sci. 52, 2024), a concept of stellarator reactor (ASTER-CP) based on swirling Li-molten salts and liquid lithium floating on the molten salt as PFC was presented. The divertor matters were not studied then and, thus, they are being studied and experimentally tested now. The ASTER-CP reactor concept, the initial liquid metal experiments and potential concepts for the ASTER-CP divertor and first wall are reported. Concerning the experiments, several small scale experiments of galinstan in a small rotating cylinder under magnetic field have been produced, including one experiment with high viscosity galinstan-mixture for increased thickness of layer. An experiment of floating lithium on the molten salt LiCl-PbCl2 gave fast volatilization/decomposition of the molten salt. Particularly for divertors, the traditional free-flow, Capillary Porous Systems and ‘divertorlets’ have been studied for application to ASTER-CP. Surface waves (hot spots), lack of enough surface fluid turbulence and excessive fluid speed are the main issues found in fast free-flow. The perhaps original concept of Distributed Divertor and Equi-power Surface is tentatively proposed and studied, taking advantage of stellarator fields and low recycling regime.

distributed divertor↗

Measurement of Resistance, Porosity, and Water Contact Angle of Porous Transport Layers for Low-Temperature Electrolysis Technologies

The porous transport layer is an important component of low-temperature electrolysis devices, such as proton exchange membrane water electrolyzers or anion exchange membrane water electrolyzers. PTLs have significant influence on the cell performance as their bulk resistance can impact the ohmic resistance, their contact resistance can impact electrode performance, and their structure can impact the liquid flow to the cell, which could cause mass-transport losses. In order to improve cell performance, optimization of the PTL is critical. Standardized protocols should be utilized to adequately compare PTLs being developed from different institutions. This method will detail a standardized protocol for measuring the resistance of the PTL using a four-wire setup and will also detail a process for measuring the porosity and water contact angle of the PTL using capillary flow porometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Blood Plasma Self-Separation Technologies during the Self-Driven Flow in Microfluidic Platforms

Blood plasma is the most commonly used biofluid in disease diagnostic and biomedical analysis due to it contains various biomarkers. The majority of the blood plasma separation is still handled with centrifugation, which is off-chip and time-consuming. Therefore, in the Lab-on-a-chip (LOC) field, an effective microfluidic blood plasma separation platform attracts researchers’ attention globally. Blood plasma self-separation technologies are usually divided into two categories: active self-separation and passive self-separation. Passive self-separation technologies, in contrast with active self-separation, only rely on microchannel geometry, microfluidic phenomena and hydrodynamic forces. Passive self-separation devices are driven by the capillary flow, which is generated due to the characteristics of the surface of the channel and its interaction with the fluid. Comparing to the active plasma separation techniques, passive plasma separation methods are more considered in the microfluidic platform, owing to their ease of fabrication, portable, user-friendly features. We propose an extensive review of mechanisms of passive self-separation technologies and enumerate some experimental details and devices to exploit these effects. The performances, limitations and challenges of these technologies and devices are also compared and discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Dean vortex-enhanced blood plasma separation in self-driven spiral microchannel flow with cross-flow microfilters

Point-of-care (POC) diagnostic devices have been developing rapidly in recent years, but they are mainly using saliva instead of blood as a test sample. A highly efficient self-separation during the self-driven flow without power systems is desired for expanding the point-of-care diagnostic devices. Microfiltration stands out as a promising technique for blood plasma separation but faces limitations due to blood cell clogging, resulting in reduced separation speed and efficiency. These limitations are mainly caused by the high viscosity and hematocrit in the blood flow. A small increment in the hematocrit of the blood significantly increases the pressure needed for the blood plasma separation in the micro-filters and decreases the separation speed and efficiency. Addressing this challenge, this study explores the feasibility of diluting whole blood within a microfluidic device without external power systems. This study implemented a spiral microchannel utilizing the inertial focusing and Dean vortex effects to focus the red blood cells and extract the blood with lower hematocrit. The inertial migration of the particles during the capillary flow was first investigated experimentally; a maximum of 88% of the particles migrated to the bottom and top equilibrium positions in the optimized 350 × 60 μm (cross-sectional area, 5.8 aspect ratio) microchannel. With the optimized dimension of the microchannel, the whole blood samples within the physiological hematocrit range were tested in the experiments, and more than 10% of the hematocrit reduction was compared between the outer branch outlet and inner branch outlet in the 350 × 60 μm microchannel.

Biochemistry & Molecular Biology↗