Search NASA⌕ Search

SEARCH · Search NASA

Results for “capillary pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Capillary Pressure of a Liquid Between Uniform Spheres Arranged in a Square-Packed Layer

The capillary pressure in the pores defined by equidimensional close-packed spheres is analyzed numerically. In the absence of gravity the menisci shapes are constructed using Surface Evolver code. This permits calculation the free surface mean curvature and hence the capillary pressure. The dependences of capillary pressure on the liquid volume constructed here for a set of contact angles allow one to determine the evolution of basic capillary characteristics under quasi-static infiltration and drainage. The maximum pressure difference between liquid and gas required for a meniscus passing through a pore is calculated and compared with that for hexagonal packing and with approximate solution given by Mason and Morrow [l]. The lower and upper critical liquid volumes that determine the stability limits for the equilibrium capillary liquid in contact with square packed array of spheres are tabulated for a set of contact angles.

Alexader, J. Iwan D.↗

Multiphase Transport in Porous Media: Gas-Liquid Separation Using Capillary Pressure Gradients International Space Station (ISS) Flight Experiment Development

Advances in the understanding of multiphase flow characteristics under variable gravity conditions will ultimately lead to improved and as of yet unknown process designs for advanced space missions. Such novel processes will be of paramount importance to the success of future manned space exploration as we venture into our solar system and beyond. In addition, because of the ubiquitous nature and vital importance of biological and environmental processes involving airwater mixtures, knowledge gained about fundamental interactions and the governing properties of these mixtures will clearly benefit the quality of life here on our home planet. The techniques addressed in the current research involving multiphase transport in porous media and gas-liquid phase separation using capillary pressure gradients are also a logical candidate for a future International Space Station (ISS) flight experiment. Importantly, the novel and potentially very accurate Lattice-Boltzmann (LB) modeling of multiphase transport in porous media developed in this work offers significantly improved predictions of real world fluid physics phenomena, thereby promoting advanced process designs for both space and terrestrial applications.This 3-year research effort has culminated in the design and testing of a zero-g demonstration prototype. Both the hydrophilic (glass) and hydrophobic (Teflon) media Capillary Pressure Gradient (CPG) cartridges prepared during the second years work were evaluated. Results obtained from ground testing at 1-g were compared to those obtained at reduced gravities spanning Martian (13-g), Lunar (16-g) and zero-g. These comparisons clearly demonstrate the relative strength of the CPG phenomena and the efficacy of its application to meet NASAs unique gas-liquid separation (GLS) requirements in non-terrestrial environments.LB modeling software, developed concurrently with the zero-g test effort, was shown to accurately reproduce observed CPG driven gas-liquid separation phenomena. The design and fabrication of a micropost plate-lamina Hele-Shaw (HS) cell was performed which served as a computationally attainable geometric structure facilitating direct comparison between physical phenomena observed in our laboratory and the LB software predictions.

Wheeler, Richard R., Jr.↗

Capillary Pressure Balance with Repeated Head-Up Tilt in Humans

We measured blood density (BD). plasma density (PD) and hematocrit (Ht) during repeated 70 deg head-up tilt (HUT) consisting of a pre-drink period with two supine (P and P3) and two HUT (P2 and P4) phases of 45 min each. At the end of P4 test subjects (N=8) drank 10 ml/kg body weight of isotonic (290 mOsm/kg) sodium chloride (ISO) or hypotonic (<10 mOsm/kg) unsweetened us (HYP), or nothing (control: CON). The following periods continued the supine (P5, P7) / upright (P6) sequence. Mass density of plasma and whole blood using a "mechanical oscillation" technique were measured from ear lobe blood. Tilting altered (p<0.001) BD, PD, and Ht in all consecutive Phases. BD and PD were different (p<0.05) between CON. HYP. and ISO Phases 6 and 7. The computed mass density of fluid (FD). which moved between intra. and extravascular compartments. averaged 1008 g/l and was the same in any conditions. In the non-drink treatment (P3, P5, P7), supine PV steadly decreased when compared to P1. Tilt-induced PV shifts ranged from 9.7 to 16.7% when compared to PV du. ring the respective previous Phases. After drinking, PV increased above CON values at the end of Phase 7 by 12.9% with ISO, and by 6.6% with HYP. Progressive hemoconcentration. occurred during non-drink supine; isotonic saline ingestion increased supine PV a control level but did not stop or reverse the decrease of upright hemoconcentration. Upright density values were not slowed with repeated upright tilting; decreased fluid loss occurred in consecutive upright periods. Upright capillary pressure balance was achieved with diminished plasma volume loss during repeated tilting.

Hinghofer-Szalkay, H. G.↗

Direct measurement of capillary blood pressure in the human lip

In this study, we developed and tested a new procedure for measuring microcirculatory blood pressures above heart level in humans. Capillary and postcapillary venule blood pressures were measured directly in 13 human subjects by use of the servonulling micropressure technique adapted for micropuncture of lip capillaries. Pressure waveforms were recorded in 40 separate capillary vessels and 14 separate postcapillary venules over periods ranging from 5 to 64 s. Localization and determination of capillary and postcapillary vessels were ascertained anatomically before pressure measurements. Capillary pressure was 33.2 +/- 1.5 (SE) mm Hg in lips of subjects seated upright. Repeated micropunctures of the same vessel gave an average coefficient of variation of 0.072. Postcapillary venule pressure was 18.9 +/- 1.6 mm Hg. This procedure produces a direct and reproducible means of measuring microvascular blood pressures in a vascular bed above heart level in humans.

Parazynski, S. E.↗

Relationship of echocardiographic indices to pulmonary capillary wedge pressures in healthy volunteers

OBJECTIVES: We sought to determine the relationship between different echocardiographic indices and pulmonary capillary wedge pressures (PCWP) in normal volunteers. BACKGROUND: Indices based on tissue Doppler (TDE) and color M-mode (CMM) echocardiography have been proposed to reflect left (LV) ventricular filling pressures. These include the ratio of early diastolic transmitral velocity (E) to early myocardial velocity measured by TDE (E') and the ratio of E to the wave propagation velocity (Vp) measured from CMM images. These indices, however, have not been validated in normal individuals. METHODS: We studied seven volunteers during two phases of preload altering maneuvers, baseline, with two stages of lower body negative pressure, and repeat baseline with two stages of volume loading. The PCWP obtained from right heart catheterization was compared with diastolic indices using pulsed Doppler, TDE and CMM echocardiography. RESULTS: The PCWP ranged from 2.2 to 23.5 mm Hg. During preload alterations, significant changes in E and septal E' (both p < 0.05) but not lateral E' or Vp were observed. Furthermore, E, septal E' and E/Vp correlated with PCWP (all r > 0.80) but not combined E and TDE indices (both r < 0.15). Within individuals, a similar linear relationship was observed among E/Vp, E and septal E' (average r > 0.80). CONCLUSIONS: In subjects without heart disease, E, septal E' and E/Vp correlate with PCWP. Because the influence of ventricular relaxation is minimized, the ratio E/Vp may be the best overall index of LV filling pressures.

NASA Discipline Cardiopulmonary↗

Constrained Vapor Bubble

The nonisothermal Constrained Vapor Bubble, CVB, is being studied to enhance the understanding of passive systems controlled by interfacial phenomena. The study is multifaceted: 1) it is a basic scientific study in interfacial phenomena, fluid physics and thermodynamics; 2) it is a basic study in thermal transport; and 3) it is a study of a heat exchanger. The research is synergistic in that CVB research requires a microgravity environment and the space program needs thermal control systems like the CVB. Ground based studies are being done as a precursor to flight experiment. The results demonstrate that experimental techniques for the direct measurement of the fundamental operating parameters (temperature, pressure, and interfacial curvature fields) have been developed. Fluid flow and change-of-phase heat transfer are a function of the temperature field and the vapor bubble shape, which can be measured using an Image Analyzing Interferometer. The CVB for a microgravity environment, has various thin film regions that are of both basic and applied interest. Generically, a CVB is formed by underfilling an evacuated enclosure with a liquid. Classification depends on shape and Bond number. The specific CVB discussed herein was formed in a fused silica cell with inside dimensions of 3x3x40 mm and, therefore, can be viewed as a large version of a micro heat pipe. Since the dimensions are relatively large for a passive system, most of the liquid flow occurs under a small capillary pressure difference. Therefore, we can classify the discussed system as a low capillary pressure system. The studies discussed herein were done in a 1-g environment (Bond Number = 3.6) to obtain experience to design a microgravity experiment for a future NASA flight where low capillary pressure systems should prove more useful. The flight experiment is tentatively scheduled for the year 2000. The SCR was passed on September 16, 1997. The RDR is tentatively scheduled for October, 1998.

Huang, J.↗

Transcapillary fluid shifts in head and neck tissues during and after simulated microgravity

To understand the mechanism, magnitude, and time course of facial puffiness that occurs in microgravity, seven male subjects were tilted 6 degrees head down for 8 hr, and all four Starling transcapillary pressures were directly measured before, during, and after tilt. Head-down tilt (HDT) caused facial edema and a significant elevation of microvascular pressures measured in the lower lip: capillary pressures increased from 27.2 +/- 5 mm Hg pre-HDT to 33.9 +/- 1.7 mm Hg by the end of tilt. Subcutaneous and intramuscular interstitial fluid pressures in the neck also increased as a result of HDT, while interstitial fluid colloid osmotic pressures remained unchanged. Plasma colloid osmotic pressures dropped significantly after 4 hr of HDT, suggesting a transition from fluid filtration to absorption in capillary beds between the heart and feet during HDT. After 4 hr of seated recovery from HDT, microvascular pressures remained significantly elevated by 5 to 8 mm Hg above baseline values, despite a significant HDT diuresis and the orthostatic challenge of an upright, seated posture. During the control (baseline) period, urine output was 46.7 ml/hr; during HDT, it was 126.5 ml/hr. These results indicate that facial edema resulting from HDT is primarily caused by elevated capillary pressures and decreased plasma colloid osmotic pressures. Elevation of cephalic capillary pressures sustained for 4 hr after HDT suggests that there is a compensatory vasodilation to maintain microvascular perfusion. The negativity of interstitial fluid pressures above heart level also has implications for the maintenance of tissue fluid balance in upright posture.

Parazynski, S. E.↗

Capillary flow through heat-pipe wicks

Theoretical expressions are obtained for the capillary-pressure limit and permeability of a fibrous wick in terms of the porosity and fiber diameter. Hysteresis in capillary pressure is included through the introduction of an empirical hysteresis constant. A partial-saturation model based on the statistical distribution of local porosity requires an additional empirical constant, the standard deviation. The theory is compared to results of a beta-ray absorption experiment that measured the liquid content of a partially saturated wick and to results of permeability measurements on partially and fully saturated wicks. A simple wick-weighing experiment is described that yields values for the empirical hysteresis constant and the standard deviation. Theoretical results are used to design an optimum wick.

Eninger, J. E.↗

On the Stability and Phase Behavior of Titan's Subsurface Liquid Columns

On Titan, liquid hydrocarbon may stay in the subsurface porous permeable crust known as the alkanofer, analogous to water in Earth’s aquifer. In addition to pressure gradient, the subsurface liquid in alkanofers is subject to vertical compositional grading due to the gravity and temperature gradient. The common wisdom is that the liquid would normally stay underground in a stability established by the pressure that increases with depth as observed in aquifers on Earth. However, Titan’s liquids consist of nitrogen and hydrocarbons, mainly methane and ethane, the behavior of which is very sensitive to temperature and pressure. Consequently, the liquid density does not always increase with depth, thus may introduce a reverse density profile that leads to vertical convective instability of the liquid column. If reverse density profiles are present, capillary pressures arising from liquid trapped within small pores in the crust can help with the column stability. The liquid held in the capillaries can seal the space below it thus helping with the stability, unless the overpressure built from underneath becomes larger than the capillary pressure, which causes leakage to allow the liquids to seep upward from the deep. This situation is analogous to hydrocarbon seeps on Earth, where oil and natural gas escape the reservoir and flow slowly through network of cracks to the surface. An algorithm based on an extended Gibbs equation commonly used in petroleum reservoir engineering is employed in this work to produce pressure, density, and compositional profiles for evaluating the stability and phase behavior of Titan’s subsurface fluids.

Sugata Tan↗

High pressure pulsed capillary viscometry

An analytical and test program was conducted in order to establish the feasibility of a multichamber pulsed-capillary viscometer. The initial design incorporated a piston, ram, and seals which produced measured pulses up to 30,000 psi in the closed chamber system. Pressure pulses from one to ten milliseconds were investigated in a system volume of 1 cuin. Four test fluids: a MIL-L-7808, a 5P4E polyphenyl ether, a MIL-L-23699A, and a synthetic hydrocarbon were examined in the test pressure assembly. The pressure-viscosity coefficient and viscosity delay time were determined for the MIL-L-7808 lubricant tested.

Smith, R. L.↗

Pore size engineering applied to the design of separators for nickel-hydrogen cells and batteries

Pore size engineering in starved alkaline multiplate cells involves adopting techniques to widen the volume tolerance of individual cells. Separators with appropriate pore size distributions and wettability characteristics (capillary pressure considerations) to have wider volume tolerances and an ability to resist dimensional changes in the electrodes were designed. The separators studied for potential use in nickel-hydrogen cells consist of polymeric membranes as well as inorganic microporous mats. In addition to standard measurements, the resistance and distribution of electrolyte as a function of total cell electrolyte content were determined. New composite separators consisting of fibers, particles and/or binders deposited on Zircar cloth were developed in order to engineer the proper capillary pressure characteristics in the separator. These asymmetric separators were prepared from a variety of fibers, particles and binders.

Abbey, K. M.↗

Pore size engineering applied to the design of separators for nickel-hydrogen cells and batteries

Pore size engineering in starved alkaline multiplate cells involves adopting techniques to widen the volume tolerance of individual cells. Separators with appropriate pore size distributions and wettability characteristics (capillary pressure considerations) to have wider volume tolerances and an ability to resist dimensional changes in the electrodes were designed. The separators studied for potential use in nickel-hydrogen cells consist of polymeric membranes as well as inorganic microporous mats. In addition to standard measurements, the resistance and distribution of electrolyte as a function of total cell electrolyte content were determined. New composite separators consisting of fibers, particles and/or binders deposited on Zircar cloth were developed in order to engineer the proper capillary pressure characteristics in the separator. These asymmetric separators were prepared from a variety of fibers, particles and binders. Previously announced in STAR as N83-24571

Abbey, K. M.↗

Fluid shifts and muscle function in humans during acute simulated weightlessness

The acute effects of simulated weightlessness on transcapillary fluid balance, tissue fluid shifts, muscle function, and triceps surface reflex time were studied in eight supine human subjects who were placed in a 5 degrees head-down tilt position for 8 hr. Results show a cephalic fluid shift from the legs as indicated by facial edema, nasal congestion, increased urine flow, decreased creatinine excretion, reduced calf girth, and decreased lower leg volume. The interstitial fluid pressure in the tibialis anterior muscle and subcutaneous tissue of the lower leg was found to fall significantly, while other transcapillary pressures (capillary and interstitial fluid colloid osmotic pressures) were relatively unchanged. The total water content of the soleus muscle was unchanged during the head-down tilt. After head-down tilt, isometric strength and isokinetic strength of the plantar flexors were unchanged, while the triceps surae reflex time associated with plantar flexion movement slowed slightly. These results demonstrate a dehydration effect of head-down tilt on muscle and subcutaneous tissue of the lower leg that may affect muscle function.

Hargens, A. R.↗

Non-Isothermal Experimental Study of the Constrained Vapor Bubble Thermosyphon

Experimental and theoretical techniques to study non-isothermal transport processes in the constrained vapor bubble thermosyphon (CVBT) were developed using a pentane/quartz system. The transport processes can be evaluated by measuring the liquid film profile, which gives the pressure field, and the temperature field. The axial variation in the capillary pressure was measured using an image-analyzing interferometer that is based on computer-enhanced video microscopy of the naturally occurring interference fringes. Thermoelectric coolers were used to control the temperature level in the condensation region and, therefore, the length of the approximately 'adiabatic' surface region which is a function of the temperature difference between the CVBT surface and the surroundings. High values for the axial thermal conductance in the 'adiabatic' surface region were demonstrated under certain conditions.

Karthikeyan, Muthu↗

Stress failure of pulmonary capillaries: role in lung and heart disease

Pulmonary capillaries have extremely thin walls to allow rapid exchange of respiratory gases across them. Recently it has been shown that the wall stresses become very large when the capillary pressure is raised, and in anaesthetised rabbits, ultrastructural damage to the walls is seen at pressures of 40 mm Hg and above. The changes include breaks in the capillary endothelial layer, alveolar epithelial layer, and sometimes all layers of the wall. The strength of the thin part of the capillary wall can be attributed to the type IV collagen in the extracellular matrix. Stress failure of pulmonary capillaries results in a high-permeability form of oedema, or even frank haemorrhage, and is apparently the mechanism of neurogenic pulmonary oedema and high-altitude pulmonary oedema. It also explains the exercise-induced pulmonary haemorrhage that occurs in all racehorses. Several features of mitral stenosis are consistent with stress failure. Overinflation of the lung also leads to stress failure, a common cause of increased capillary permeability in the intensive care environment. Stress failure also occurs if the type IV collagen of the capillary wall is weakened by autoantibodies as in Goodpasture's syndrome. Neutrophil elastase degrades type IV collagen and this may be the starting point of the breakdown of alveolar walls that is characteristic of emphysema. Stress failure of pulmonary capillaries is a hitherto overlooked and potentially important factor in lung and heart disease.

Review↗

Sub-mm Scale Fiber Guided Deep/Vacuum Ultra-Violet Optical Source for Trapped Mercury Ion Clocks

We demonstrate the functionality of a mercury capillary lamp with a diameter in the sub-mm range and deep ultraviolet (DUV)/ vacuum ultraviolet (VUV) radiation delivery via an optical fiber integrated with the capillary. DUV spectrum control is observed by varying the fabrication parameters such as buffer gas type and pressure, capillary diameter, electrical resonator design, and temperature. We also show spectroscopic data of the 199Hg+ hyper-fine transition at 40.5GHz when applying the above fiber optical design. We present efforts toward micro-plasma generation in hollow-core photonic crystal fiber with related optical design and theoretical estimations. This new approach towards a more practical DUV optical interface could benefit trapped ion clock developments for future ultra-stable frequency reference and time-keeping applications.

lamps↗