Search NASA⌕ Search

SEARCH · Search NASA

Results for “capillary zone electrophoresis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

The Non-Destructive Separation of Diverse Astrobiologically Relevant Organic Molecules By Customizable Capillary Zone Electrophoresis and Monolithic Capillary Electrochromatography

The in situ detection of organic molecules in space is key to understanding the variety and the distribution of the building blocks of life, and possibly the detection of extraterrestrial life itself. Gas chromatography mass spectrometry (GC-MS) has been the most sensitive analytical instrument for organic analyses in flight, and was used on missions from NASA’s Viking, Phoenix, Curiosity missions to ESA’s Rosetta space probe. While pyrolysis GC-MS revealed the first organics on Mars, this step alters or degrades certain fragile molecules that are excellent biosignatures including polypeptides, oligonucleotides and polysaccharides, rendering the intact precursors undetectable. We have identified a solution tailored to the detection of biopolymers and other biomarkers by the use of liquid-based capillary electrophoresis and electrochromatography. In this study, we show that a capillary electrochromatography (CEC) approach using monolithic stationary phases with tailor-made surface chemistry can separate and identify various polycyclic aromatic hydrocarbons (PAHs), nucleobases and aromatic acids that could be formed under astrophysically relevant conditions. In order to simulate flyby organic sample capture, we conducted hypervelocity impact experiments which consisted of accelerating peptide-soaked montmorillonite particles to a speed of 5.6 km/sec, and capturing them in an amorphous silica aerogel of 10 and 30 mg/cc bulk density. Bulk peptide extraction from aerogel followed by capillary zone electrophoresis led to the detection of only two stereoisomeric peptide peaks. The recovery rates of each step of the extraction procedure after the hypervelocity impact suggest that major peptide loss occurred during the impact. Our study provides initial exploration of feasibility of this approach for capturing intact peptides, and subsequently detecting candidate biomolecules during flight missions that would be missed by GC-MS alone. As the monolith-based electrochromatography technology could be customized to detect specific classes of compounds as well as miniaturized, these results demonstrate the potential of the instrumentation for future astrobiology-related spaceflight missions.

Flyby sample return↗

Theoretical and experimental separation dynamics in capillary zone electrophoresis

The mathematical model of Bier et al. (1983) is used in a computer aided analysis of the conditions in capillary zone electrophoresis (ZE) under which sample zones migrate noninteractively with the carrier electrolyte. The monitoring of sample zones with a capillary analyzer that features both on-line conductivity and UV detection at the end of the separation trough is discussed. Data from a ZE analysis of a 5-component mixture are presented, and it is noted that all five components can be monitored via their conductivity change if enough sample is present. It is suggested from the results that the concentration ratio of background buffer to sample should be a minimum of 100:1 to effectively apply the plate concept to ZE.

Thormann, Wolfgang↗

Evaluation of available analytical techniques for monitoring the quality of space station potable water

To assure the quality of potable water (PW) on the Space Station (SS) a number of chemical and physical tests must be conducted routinely. After reviewing the requirements for potable water, both direct and indirect analytical methods are evaluated that could make the required tests and improvements compatible with the Space Station operation. A variety of suggestions are made to improve the analytical techniques for SS operation. The most important recommendations are: (1) the silver/silver chloride electrode (SB) method of removing I sub 2/I (-) biocide from the water, since it may interfere with analytical procedures for PW and also its end uses; (2) the orbital reactor (OR) method of carrying out chemistry and electrochemistry in microgravity by using a disk shaped reactor on an orbital table to impart artificial G force to the contents, allowing solution mixing and separation of gases and liquids; and (3) a simple ultra low volume highly sensitive electrochemical/conductivity detector for use with a capillary zone electrophoresis apparatus. It is also recommended, since several different conductivity and resistance measurements are made during the analysis of PW, that the bipolar pulse measuring circuit be used in all these applications for maximum compatibility and redundancy of equipment.

Geer, Richard D.↗

Search for Unique Organic Biomarkers in ALH84001

Four goals were outlined for this project. These were: [1] to reproduce the measurement of polycyclic aromatic hydrocarbons (PAHS) in ALH84001 with both a higher spatial resolution and sensitivity than has been previously reported; [2] to extend such measurements to include other members of the Martian SNC (Shergotties, Nahklites, and Chassigny) meteorite clan, in particular the Antarctic Martian meteorite EETA79001; [3] to address issues of potential organic contamination, because at present very little is known about the effect of terrestrial weathering in the Antarctic environment as it pertains to perturbing an indigenous organic distribution within a meteoritic matrix; and [4] to diversify the range of organic compounds studied to include species that can serve as unique biological markers - "molecular fossils" - derived from once living organisms. In order to achieve this, three specific goals were outlined for the funding period 06/01/97 to 02/28/98. They were: [1] to investigate the effects of terrestrial weathering and organic contamination of meteoritic samples collected from Antarctica; [2] to reproduce and extend upon the measurements of PAHs in ALH84001 with the aim of establishing or refuting the indigeneity of these species; and [3] to extend the analysis of organic compounds in ALH84001 and EETA79001 to address compounds that are considered to be more biologically relevant than PAHS. All three were successfully accomplished, as detailed in the previous performance report. In brief, however, the results achieved were to establish that the PAHs found in ALH84001 were indigenous and not due to contamination, and to determine that a novel and sensitive technique in meteoritic work, capillary zone electrophoresis (CE), could indeed detect amino acids, a potential class of biomarker.

Zare, Richard N.↗

Integration of a Micro-Chip Amino Acid Chirality Detector into the MOD Instrument Concept

The MOD (Mars Organic Detector) instrument concept consists of a sublimation apparatus for organic compound isolation connected to a microfabricated microfluidic analyzer containing a sipper, pumps and a separation channel for organic compound characterization. The target organic compounds are amino acids and polycyclic aromatic hydrocarbons (PAHs). Solid samples are placed within the sublimation apparatus and heated to release organic compounds which sublime onto a cold finger. Half of the cold finger is coated with fluorescamine. which reacts with amino acids and other primary amines to generate an intense fluorescent derivative while the other half is uncoated and is used to directly detect PAH fluorescence, A capillary sipper is then used to dissolve and sample the labeled amino acids and integrated microfabricated pumps transport the labeled amino acids to the chip for analysis. The sample is separated using capillary zone electrophoresis (CZE) together with chiral dextrins to determine amino acid composition and chirality. During the grant period, the following steps have been completed toward the development of a robust instrument and chemistry.

Bada, Jeffrey L.↗

Effects of coating rectangular microscopic electrophoresis chamber with methylcellulose

One of the biggest problems in obtaining high accuracy in microscopic electrophoresis is the parabolic flow of liquid in the chamber due to electroosmotic backflow during application of the electric field. In chambers with glass walls the source of polarization leading to electroosmosis is the negative charge of the silicare and other ions that form the wall structure. It was found by Hjerten, who used a rotating 3.0 mm capillary tube for free zone electrophoresis, that precisely neutralizing this charge was extremely difficult, but if a neutral polymer matrix (formaldehyde fixed methylcellulose) was formed over the glass (quartz) wall the double layer was displaced and the viscosity at the shear plane increased so that electroosmotic flow could be eliminated. Experiments were designed to determine the reliability with which methylcellulose coating of the Zeiss Cytopherometer chamber reduced electroosmotic backflow and the effect of coating on the accuracy of cell electrophoretic mobility (EPN) determinations. Fixed rat erythrocytes (RBC) were used as test particles.

Plank, L. D.↗