Search NASA⌕ Search

SEARCH · Search NASA

Results for “causal impedance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

FOSWEC v2: System identification and control testing at Hinsdale Wave Research Laboratory

This report summarizes the design and execution of a wave tank test of the floating oscillating surge wave energy converter (FOSWEC) in the O.H. Hinsdale Wave Research Laboratory Directional Wave Basin at Oregon State University. This device, which uses two "flaps" that pivot about a central platform when excited by waves, has a natural frequency within the range of the waves by which it is excited. The FOSWEC was originally considered to be a 1:33 scale device, however, for the current tests, no fixed relative scale is used (i.e., the WEC is considered to be scaled for the basin’s wave environment in which it operates). The primary goal of this test was to assess the degree to which previously developed modeling, experimentation, and control design methods could be applied to a broad range of wave energy converter designs. Testing was conducted to identify a dynamic model for the impedance and excitation behavior of the device. Using these models, a series of closed loop tests were conducted using a causal impedance matching controller. This report provides a brief description of the results, as well as a summary of the device and experimental design. The results show that the methods applied to this experimental device perform well and should be broadly applicable. The data collected during testing is compressed into FOSWEC.zip. Please refer to Appendix C (pages 61-63) of the test report for descriptions of each test ID corresponding to the compressed files.

16 TIDAL AND WAVE POWER↗

FOSWEC dynamics and controls test report

This report describes the testing of a model scale wave energy converter. This device, which uses two aps that pivot about a central platform when excited by waves, has a natural frequency within the range of the waves by which it is excited. The primary goal of this test was to assess the degree to which previously developed modeling, experimentation, and control design methods could be applied to a broad range of wave energy converter designs. Testing was conducted to identify a dynamic model for the impedance and excitation behavior of the device. Using these models, a series of closed loop tests were conducted using a causal impedance matching controller. This report provides a brief description of the results, as well as a summary of the device and ex- perimental design. The results show that the methods applied to this experimental device perform well and should be broadly applicable.

16 TIDAL AND WAVE POWER↗

fbWecCntrl

fbWecCntrl is set of MATLAB functions and scripts demonstrating a causal impedance matching approach to wave energy converter (WEC) control design. SAND2020-12219 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Coe, Ryan↗

Deterministic incident-wave elevation prediction in intermediate water depth

Potential performance gains from optimal (non-causal) impedance-matching control of wave energy devices in irregular ocean waves are dependent on deterministic wave elevation prediction techniques that work well in practical applications. Although a number of devices are designed for operation in intermediate water depths, little work has been reported on deterministic wave prediction in such depths. Here, we investigated a deterministic wave-prediction technique based on an approximate propagation model that leads to an analytical formulation, which may be convenient to implement in practice. To improve accuracy, an approach to combine predictions based on multiple up-wave measurement points is evaluated. The overall method is tested using experimental time-series measurements recorded in the U.S. Navy MASK basin in Carderock, MD, USA. For comparison, an alternative prediction approach based on Fourier coefficients is also tested with the same data. Comparison of prediction approaches with direct measurements suggest room for improvement. Possible sources of error including tank reflections are estimated, and potential mitigation approaches are discussed.

16 TIDAL AND WAVE POWER↗

Poor reliability of public charging stations can impede the growth of the electric vehicle market

How does the reliability of public charging infrastructure affect electric vehicle (EV) adoption? Substantial public and private investments are expanding EV charging networks, but concerns are growing about the poor reliability of existing chargers and its potential impacts on EV adoption. Using data from a nationwide survey, we employ a choice model to quantify the effects of perceived charging reliability on Americans’ intentions to purchase new or used EVs. By randomly assigning participants to receive information characterizing public charging as either very reliable or very unreliable, we show a causal effect of reliability perceptions on EV purchase intentions. In conclusion, we find that differences in perceived reliability are equivalent to changing price by 32 % of purchasing budget or changing range by 366 miles, underscoring the importance of reliable public charging.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comments on Control of Wave Energy Converters

The main objective of this letter is to consolidate the knowledge about the dynamics and control of oscillating-body wave energy converters (WECs). A number of studies have shown that control systems strongly affect power absorption; however, there remains a need for a concise and integrated explanation of the theoretical and practical implications that control can have on both performance and the broader WEC design process. This short letter attempts to fill this gap by presenting a discussion on the key practical aspects concerning the dynamics and control of oscillating-body WEC. In particular, the focus is on the choice of control models and a simple causal control scheme suitable for real-time implementation. To conclude, consideration is given to the effect of the power takeoff (PTO) on the maximization of electrical power, thus leading to the derivation of useful conditions for the control co-design of the PTO system.

42 ENGINEERING↗

Real-Time Wave Energy Converter Control Using Instantaneous Frequency

Wave Energy Converters (WECs) rely on effective Power Take-Off (PTO) control strategies to maximize energy absorption under dynamic sea conditions. Traditional hydrodynamic modeling techniques may require computationally intensive convolution calculations, making real-time control implementation challenging. This paper presents an alternative approach by leveraging instantaneous frequency estimation to dynamically adjust PTO damping in response to varying wave frequencies. Two real-time frequency estimation methods are explored: the Hilbert Transform (HT) and Phase-Locked Loop (PLL). The Hilbert Transform method provides accurate frequency tracking but introduces a delayed response due to its dependence on causal data. Conversely, the PLL approach demonstrates strong potential in frequency tracking but requires careful gain tuning, particularly in complex sea states. Comparative evaluations across multiple test cases—including sinusoidal variations, amplitude steps, frequency step changes, and real-world JONSWAP spectrum waves—highlight the strengths and limitations of each method. The two different PTO control techniques across the various frequency estimation methods were tested under real-sea states using a state-space model of a point-absorbing Wave Energy Converter. The Capture Width Ratio (CWR) is used as a performance metric, with results showing that the HT achieves a 10.6% improvement, while the PLL estimation yields a 0.9% improvement relative to the fixed parameter control baseline. These results highlight the effectiveness of real-time frequency estimation in improving energy absorption compared to static control parameters.

WEC control↗