A portable optical emission spectroscopy-cavity ringdown spectroscopy dual-mode plasma spectrometer for measurements of environmentally important trace heavy metals: Initial test with elemental Hg

A portable optical emission spectroscopy-cavity ringdown spectroscopy (OES-CRDS) dual-mode plasma spectrometer is described. A compact, low-power, atmospheric argon microwave plasma torch (MPT) is utilized as the emission source when the spectrometer is operating in the OES mode. The same MPT serves as the atomization source for ringdown measurements in the CRDS mode. Initial demonstration of the instrument is carried out by observing OES of multiple elements including mercury (Hg) in the OES mode and by measuring absolute concentrations of Hg in the metastable state 6s6p {sup 3}P{sub 0} in the CRDS mode, in which a palm-size diode laser operating at a single wavelength 405 nm is incorporated in the spectrometer as the light source. In the OES mode, the detection limit for Hg is determined to be 44 parts per 10{sup 9} (ppb). A strong radiation trapping effect on emission measurements of Hg at 254 nm is observed when the Hg solution concentration is higher than 50 parts per 10{sup 6} (ppm). The radiation trapping effect suggests that two different transition lines of Hg at 253.65 nm and 365.01 nm be selected for emission measurements in lower (<50 ppm) and higher concentration ranges (>50 ppm), respectively. In the CRDS mode, the detection limit of Hg in the metastable state 6s6p {sup 3}P{sub 0} is achieved to be 2.24 parts per 10{sup 12} (ppt) when the plasma is operating at 150 W with sample gas flow rate of 480 mL min{sup -1}; the detection limit corresponds to 50 ppm in Hg sample solution. Advantage of this novel spectrometer has two-fold, it has a large measurement dynamic range, from a few ppt to hundreds ppm and the CRDS mode can serve as calibration for the OES mode as well as high sensitivity measurements. Measurements of seven other elements, As, Cd, Mn, Ni, P, Pb, and Sr, using the OES mode are also carried out with detection limits of 1100, 33, 30, 144, 576, 94, and 2 ppb, respectively. Matrix effect in the presence of other elements on Hg measurements has been found to increase the detection limit to 131 ppb. These elements in lower concentrations can also be measured in the CRDS mode when a compact laser source is available to be integrated into the spectrometer in the future. This exploratory study demonstrates a new instrument platform using an OES-CRDS dual-mode technique for potential field applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of the Weak UV Absorptions of Isoprene and Acetone at 261–275 nm Using Cavity Ringdown Spectroscopy for Evaluation of a Potential Portable Ringdown Breath Analyzer

The weak absorption spectra of isoprene and acetone have been measured in the wavelength range of 261–275 nm using cavity ringdown spectroscopy. The measured absorption cross-sections of isoprene in the wavelength region of 261–266 nm range from 3.65 ×10 –21 cm 2 ·molecule –1 at 261 nm to 1.42 × 10 –21 cm 2 ·molecule –1 at 266 nm; these numbers are in good agreement with the values reported in the literature. In the longer wavelength range of 270–275 nm, however, where attractive applications using a single wavelength compact diode laser operating at 274 nm is located, isoprene has been reported in the literature to have no absorption (too weak to be detected). Small absorption cross-sections of isoprene in this longer wavelength region are measured using cavity ringdown spectroscopy for the first time in this work, i.e., 6.20 ×10 –23 cm 2 ·molecule –1 at 275 nm. With the same experimental system, wavelength-dependent absorption cross-sections of acetone have also been measured. Theoretical detection limits of isoprene and comparisons of absorbance of isoprene, acetone, and healthy breath gas in this wavelength region are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lowest triplet (n,π{sup *}) state of 2-cyclohexen-1-one: Characterization by cavity ringdown spectroscopy and quantum-chemical calculations

The cavity ringdown (CRD) absorption spectrum of 2-cyclohexen-1-one (2CHO) was recorded over the range 401.5–410.5 nm in a room-temperature gas cell. The very weak band system (ε ⩽ 0.1 M{sup −1} cm{sup −1}) in this spectral region is due to the T{sub 1}(n, π*) ← S{sub 0} electronic transition. The 0{sub 0}{sup 0} origin band was assigned to the feature observed at 24 558.8 ± 0.3 cm{sup −1}. We have assigned 46 vibronic transitions in a region extending from −200 to +350 cm{sup −1} relative to the origin band. For the majority of these transitions, we have made corresponding assignments in the spectrum of the deuterated derivative 2CHO-2,6,6-d{sub 3}. From the assignments, we determined fundamental frequencies for several vibrational modes in the T{sub 1}(n, π{sup *}) excited state of 2CHO, including the lowest ring-twisting (99.6 cm{sup −1}) and ring-bending (262.2 cm{sup −1}) modes. These values compare to fundamentals of 122.2 cm{sup −1} and 251.9 cm{sup −1}, respectively, determined previously for the isoconfigurational S{sub 1}(n, π{sup *}) excited state of 2CHO and 99 cm{sup −1} and 248 cm{sup −1}, respectively, for the S{sub 0} ground state. With the aid of quantum-mechanical calculations, we have also ascertained descriptions for these two modes, thereby resolving ambiguities appearing in the previous literature. The ring-twisting mode (ν{sub 39}) contains a significant contribution from O=C–C=C torsion, whereas the ring-bending mode (ν{sub 38} in the ground state) involves mainly the motion of C-5 with respect to the plane containing the other heavy atoms. The CRD spectroscopic data for the T{sub 1}(n, π{sup *}) state have allowed us to benchmark several computational methods for treating excited states, including time-dependent density functional theory and an equation-of-motion coupled cluster method. In turn, the computational results provide an explanation for observed differences in the T{sub 1}(n, π{sup *}) vs. S{sub 1}(n, π{sup *}) ring frequencies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Brewster angle-cavity ringdown spectroscopy for low temperature plasma measurements in multiphases

Here we report on the development of a Brewster angle-cavity ringdown spectroscopy (BA-CRDS) system for low temperature plasma diagnostics. The system can measure gas species in solutions, with a detection limit (minimum detectable absorbance) of 9.1 × 10 -5 , which is equivalent to a detection limit of 0.04 parts per billion for measuring OH radicals in water at 308 nm. With higher reflectivity ringdown mirrors and improved design of a Brewster angle cell, the detection limit can potentially be up to 10 -6 or lower. In this exploratory study, the absorption cross sections of HgBr 2 and H 2 O 2 in the aqueous phase at 256 nm are measured to be (1.8 ± 0.1) × 10 -18 cm 2 and (5.2 ± 0.5) × 10 -20 cm 2 , respectively. Furthermore, temporal profiles of absorbance from distilled water, HgBr 2 , and H 2 O 2 solutions when interacting with a helium atmospheric plasma jet are individually characterized at different plasma powers, gas flow rates, and/or solute concentrations. The observed linear temporal profiles of absorbance from the plasma-interacted water suggest formation of H 2 O 2 from plasma-generated OH radicals, while the nonlinear temporal profiles from the plasma-treated HgBr 2 solutions reveal possible removal of HgBr 2 by OH radicals. Our results demonstrate that the new BA-CRDS system is a powerful tool for quantification of reactive plasma species in multiphases or other complex settings.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hollow waveguide cavity ringdown spectroscopy

Laser light is confined in a hollow waveguide between two highly reflective mirrors. This waveguide cavity is used to conduct Cavity Ringdown Absorption Spectroscopy of loss mechanisms in the cavity including absorption or scattering by gases, liquid, solids, and/or optical elements.

Dreyer, Chris↗

Optical 14 C Tracing for Biological and Pharmaceutical Applications Using Two-Color Cavity Ringdown Spectroscopy

Laser-based 14 C quantitation has been proposed as a more affordable, higher-throughput, table-top alternative to accelerator mass spectrometry (AMS). Here, we demonstrate the feasibility of a mid-IR 14 C detector based on two-color cavity ringdown spectroscopy (2C-CRDS) for low-level 14 C isotope tracing in biological studies. The 2C-CRDS technique quantifies the sample 14 C content by measuring the 14 CO 2 absorption signals from the combusted samples with mid-IR lasers. With 2C-CRDS, we previously demonstrated the most sensitive and accurate optical measurements of 14 CO 2 . The current detection sensitivity and quantitation accuracy of the instrument, at a few parts per quadrillion (where a quadrillion = 10 15 ) 14 C/C mole fraction, is competitive against AMS. Here, by applying the 2C-CRDS 14 C sensor to two applications relevant to 14 C-labeled biochemical analysis and pharmaceutical studies, we demonstrate sub-fCi level (where 1 fCi = 10 –15 Ci) quantitation of sample 14 C activity, with a minimum sample-size requirement of 3 mg of carbon. The current measurement throughput, ~25 min/sample, is largely limited by the sampling efficiency of the online combustion and CO 2 processing interface to the 2C-CRDS instrument. The possibility of a significantly improved measurement throughput of a few minutes per sample is suggested by the results of a flow-through 14 CO 2 sampling scheme. In conclusion, this improved measurement efficiency, combined with the relatively low cost and compact size of a 2C-CRDS sensor, could potentially revolutionize high-sensitivity 14 C tracing in biological, pharmaceutical, and clinical studies.

60 APPLIED LIFE SCIENCES↗

Two-color, intracavity pump–probe, cavity ringdown spectroscopy

Here, we report a proof-of-principle demonstration of intracavity pump–probe, cavity ringdown (CRD) detection in a three-mirror, traveling-wave cavity. With cavity-enhanced pump power and probe absorption path length, the technique is a generally applicable, high-sensitivity, high-selectivity detection method. In our experiments, the pump radiation is switched off during every other probe ringdown, which allows uncorrelated measurements of analyte and background cavity decay rates. The net, two-color signal from the difference between the pump-on and pump-off decay rates is immune to empty-CRD drifts and spectral overlaps from non-target molecular transitions. The immunity to the ringdown drifts allows longer signal-averaging and, thus, higher detection sensitivity. The ability to compensate for the background absorption enhances the detection selectivity in spectrally congested regions. Our technique is well-suited for trace-detection in the mid-IR region, where pump–probe schemes based on strong rovibrational transitions can be applied. In this work, two-color CRD detection is implemented on a ladder-type, three-level system based on the N 2 O, ν 3 = 1 ← 0, P(19) (pump) and ν 3 = 2 ← 1, R(18) (probe), rovibrational transitions. By frequency-locking two-quantum cascade lasers to the p-polarization (pump, Finesse = 5280) and s-polarization (probe, Finesse = 67 700) cavity modes, we achieve high intracavity pump power (36 W) and high probe ringdown rates (>2 kHz). The observed two-color spectra are simulated by a density-matrix, three-level system model that is solved under the constraints of the cavity resonance conditions. In addition to its background compensation capability, experimental flexibility in the selection of pump–probe schemes and signal insensitivity to intracavity laser power are further features that enhance the utility of our technique for mid-IR trace-detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser produced plasma diagnostics by cavity ringdown spectroscopy and applications

Laser-produced plasmas have many applications for which detailed characterization of the plume is requested. Cavity ring-down spectroscopy is a versatile absorption method which provides data on the plume and its surroundings, with spatial and temporal resolution. The measured absorption line shapes contain information about angular and velocity distributions within the plume. In various plasmas we have observed molecules or metastable atoms which were not present in the emission spectra.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-, space-, and molecule-resolved multiple plasma reactive species in complex settings using an innovative approach of cavity ringdown spectroscopy (Project Final Report)

The primary research goal of this 2-year project is to demonstrate the feasibility of an innovative approach to measure reactive plasma species in the most challenging settings: right on the surface of water and under water. We propose to use the Brewster angle-cavity ringdown spextroscopy (BA-CRDS). Research objectives include: 1) Measurements of OH and NO in the plasma gas-phase zone (Z1) using different types of LTP sources including continuous and pulsed plasma jets, sheets, torches, etc. 2) Measurements of OH and NO in the multiphase reaction zones, right on the surface of water (Z2) and under water (Z3). 3) RS formation and loss mechanisms and reaction dynamics in the three zones. 4) Generalization of the proposed system to be configurable with other selected innovative techniques for other LTP parameters; invitation of selected PIs to form a strong collaborative team to pursue the follow-up effort (Category-2).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Breath Analysis Using Laser Spectroscopic Techniques: Breath Biomarkers, Spectral Fingerprints, and Detection Limits

Breath analysis, a promising new field of medicine and medical instrumentation, potentially offers noninvasive, real-time, and point-of-care (POC) disease diagnostics and metabolic status monitoring. Numerous breath biomarkers have been detected and quantified so far by using the GC-MS technique. Recent advances in laser spectroscopic techniques and laser sources have driven breath analysis to new heights, moving from laboratory research to commercial reality. Laser spectroscopic detection techniques not only have high-sensitivity and high-selectivity, as equivalently offered by the MS-based techniques, but also have the advantageous features of near real-time response, low instrument costs, and POC function. Of the approximately 35 established breath biomarkers, such as acetone, ammonia, carbon dioxide, ethane, methane, and nitric oxide, 14 species in exhaled human breath have been analyzed by high-sensitivity laser spectroscopic techniques, namely, tunable diode laser absorption spectroscopy (TDLAS), cavity ringdown spectroscopy (CRDS), integrated cavity output spectroscopy (ICOS), cavity enhanced absorption spectroscopy (CEAS), cavity leak-out spectroscopy (CALOS), photoacoustic spectroscopy (PAS), quartz-enhanced photoacoustic spectroscopy (QEPAS), and optical frequency comb cavity-enhanced absorption spectroscopy (OFC-CEAS). Spectral fingerprints of the measured biomarkers span from the UV to the mid-IR spectral regions and the detection limits achieved by the laser techniques range from parts per million to parts per billion levels. Sensors using the laser spectroscopic techniques for a few breath biomarkers, e.g., carbon dioxide, nitric oxide, etc. are commercially available. This review presents an update on the latest developments in laser-based breath analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical re-injection in cavity-enhanced absorption spectroscopy

Non-mode-matched cavity-enhanced absorption spectrometry (e.g., cavity ringdown spectroscopy and integrated cavity output spectroscopy) is commonly used for the ultrasensitive detection of trace gases. These techniques are attractive for their simplicity and robustness, but their performance may be limited by the reflection of light from the front mirror and the resulting low optical transmission. Although this low transmitted power can sometimes be overcome with higher power lasers and lower noise detectors (e.g., in the near-infrared), many regimes exist where the available light intensity or photodetector sensitivity limits instrument performance (e.g., in the mid-infrared). In this article, we describe a method of repeatedly re-injecting light reflected off the front mirror of the optical cavity to boost the cavity's circulating power and deliver more light to the photodetector and thus increase the signal-to-noise ratio of the absorption measurement. We model and experimentally demonstrate the method's performance using off-axis cavity ringdown spectroscopy (OA-CRDS) with a broadly tunable external cavity quantum cascade laser. The power coupled through the cavity to the detector is increased by a factor of 22.5. The cavity loss is measured with a precision of 2 × 10{sup −10} cm{sup −1}/√(Hz;) an increase of 12 times over the standard off-axis configuration without reinjection and comparable to the best reported sensitivities in the mid-infrared. Finally, the re-injected CRDS system is used to measure the spectrum of several volatile organic compounds, demonstrating the improved ability to resolve weakly absorbing spectroscopic features.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface Absorption Polarization Sensors (SAPS), Final Technical Report, Laser Probing of Immobilized SAPS Actuators Component

A novel hypothesized detection scheme for the detection of chemical agents was proposed: SAPS ``Surface-Adsorbed Polarization Sensors''. In this technique a thin layer of molecular rotors is adsorbed to a surface. The rotors can be energized by light absorption, but are otherwise locked in position or alternatively rotate slowly. Using polarized light, the adsorbed rotors are turned as an ensemble. Chemical agent (analyte) binding that alters the rotary efficiency would be detected by sensitive polarized absorption techniques. The mechanism of the SAPS detection can be mechanical, chemical, or photochemical: only a change in rotary efficiency is required. To achieve the goal of SAPS detection, new spectroscopic technique, polarized Normal Incidence Cavity Ringdown Spectroscopy (polarized NICRDS), was developed. The technique employs very sensitive and general Cavity Ringdown absorption spectroscopy along with the ability to perform polarized absorption measurements. Polarized absorption offers the ability to measure the angular position of molecular chromophores. In the new experiments a thin layer of SAPS sensors (roughly corresponding to a monolayer coverage on a surface) immobilized in PMMA. The PMMA layer is less than 100~nm thick and is spin-coated onto a flat fused-silica substrate. The new technique was applied to study the photoisomerization-driven rotary motion of a family of SAPS actuators based on a family of substituted dibenzofulvene rotors based upon 9-(2,2,2- triphenylethylidene)fluorene. By varying the substitution to include moieties such as nitro, amino, and cyano the absorption spectrum and the quantum efficiency of photoisomerization can be varied. This SAPS effect was readily detected by polarized NICRDS. The amino substituted SAPS actuator binds H+ to form an ammonium species which was shown to have a much larger quantum efficiency for photoisomerization. A thin layer of immobilized amino actuators were then shown by polarized NICRDS to have a propensity for the angular control of rotary motion to be strongly influenced by the presence of the H+ analyte: the SAPS actuators can readily detect the presence of a H+ analyte at 1 equivalent concentration. Because the total number of SAPS actuators in the probe volume of the film is small, the amount of analyte detectable can be very low. A variety of SAPS actuator structures based on dibenzofulvene rotors are possible that could bind other analytes. It appears that analyte binding that alters the electron density in the dibenzofulvene ring is sufficient to create a detectable change in the rotary efficiency. If the analyte is strongly bound to the rotor, the SAPS actuator behaves in a dosimeter mode. Weak, reversible binding would allow for monitoring of varying concentrations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved measurements of HO 2 radical in a heated plasma flow reactor

Time-resolved, absolute HO 2 number density in diluted H 2 –O 2 –Ar, CH 4 –O 2 -Ar, and C 2 H 4 –O 2 –Ar mixtures excited by a repetitive ns pulse discharge in a heated plasma flow reactor is measured by Cavity Ringdown Spectroscopy (CRDS). The experimental results are obtained at $\textit{T}$ = 300-600 K and $\textit{P}$ = 130 Torr, both during the discharge pulse burst and in the afterglow. In this work, the HO 2 number density is inferred from the CRDS data using a spectral model exhibiting good agreement with previous measurements of absolute HO 2 absorption cross sections. In the room-temperature H 2 –O 2 mixture, as well as in CH 4 –O 2 and C 2 H 4 –O 2 mixtures over the entire temperature range studied, HO2 is generated only during the discharge burst and decays in the afterglow. However, in the H 2 –O 2 mixture at elevated temperatures, $\textit{T}$ = 400-600 K, HO 2 persists in the afterglow up to 10 ms after the discharge burst, comparable with the flow residence time in the reactor. Comparison with kinetic modeling shows that the sustained reactivity after the source of radicals is turned off is due to a chain propagation / hydrogen oxidation process, which dominates the radical recombination reactions. The kinetic modeling predictions are in good agreement with the relative HO 2 number density measured in all three mixtures, although the model underpredicts the absolute number densities in H 2 –O 2 at $\textit{T}$ = 400-600 K by up to a factor of two. Detection of the sustained low-temperature reactivity in H 2 –O 2 , initiated by the radical generation in the plasma, suggests that the plasma excitation may also affect kinetics of oxidation and reforming of fuels exhibiting low-temperature chemistry below hot ignition point.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mid-infrared trace detection with parts-per-quadrillion quantitation accuracy: Expanding frontiers of radiocarbon sensing

Detection sensitivity is a critical characteristic to consider during selection of spectroscopic techniques. However, high sensitivity alone is insufficient for spectroscopic measurements in spectrally congested regions. Two-color cavity ringdown spectroscopy (2C-CRDS), based on intra-cavity pump–probe detection, simultaneously achieves high detection sensitivity and selectivity. This combination enables mid-infrared detection of radiocarbon dioxide ( 14 CO 2 ) molecules in room-temperature CO 2 samples, with 1.4 parts-per-quadrillion (ppq, 10 − 15 ) sensitivity (average measurement precision) and 4.6-ppq quantitation accuracy (average calibrated measurement error for 21 samples from four separate trials) demonstrated on samples with 14 C/C up to ∼ 1.5 × natural abundance ( ∼ 1,800 ppq). These highly reproducible measurements, which are the most sensitive and quantitatively accurate in the mid-infrared, are accomplished despite the presence of orders-of-magnitude stronger, one-photon signals from other CO 2 isotopologues. This is a major achievement in laser spectroscopy. A room-temperature-operated, compact, and low-cost 2C-CRDS sensor for 14 CO 2 benefits a wide range of scientific fields that utilize 14 C for dating and isotope tracing, most notably atmospheric 14 CO 2 monitoring to track CO 2 emissions from fossil fuels. The 2C-CRDS technique significantly enhances the general utility of high-resolution mid-infrared detection for analytical measurements and fundamental chemical dynamics studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ESO Diffuse Interstellar Bands Large Exploration Survey (EDIBLES) - Merging Observations and Laboratory Data

The Diffuse Interstellar Bands (DIBs) are a set of ~500 absorption bands that are detected in the spectra of stars with interstellar clouds in the line of sight. DIBs are found from the NUV to the NIR in the spectra of reddened stars spanning different interstellar environments in our local, and in other galaxies. DIB carriers are a significant part of the interstellar chemical inventory. They are stable and ubiquitous in a broad variety of environments and play a unique role in interstellar physics/chemistry. It has long been realized that the solving of the DIB problem requires a strong synergy between astronomical observations, laboratory astrophysics, and astrophysical modeling of line-of-sights. PAHs are among the molecular species that have been proposed as DIB carriers. We will present an assessment of the PAH-DIB model in view of the progress and the advances that have been achieved over the past years through a series of studies involving astronomical observations of DIBs, laboratory simulation of interstellar analogs for neutrals and ionized PAHs, theoretical calculations of PAH spectra and the modelization of diffuse and translucent interstellar clouds. We will present a summary of what has been learned from these complementary studies, the constraints that can now be derived for the PAHs as DIB carriers in the context of the PAH-DIB model and how these constraints can be applied to the EDIBLES project. The spectra of several neutral and ionized PAHs isolated in the gas phase at low temperature have been measured in the laboratory under experimental conditions that mimic interstellar conditions and are compared with an extensive set of astronomical spectra of reddened, early type stars. The comparisons of astronomical and laboratory data provide upper limits for the abundances of specific neutral PAH molecules and ions along specific lines-of-sight. Something that is not attainable from infrared observations alone. We present the characteristics of the laboratory facilities, MIS and COSmIC, that have been developed for this study and discuss the findings resulting from the comparison of the laboratory data with high resolution, high S/N ratio astronomical observations. MIS stands for Matrix Isolation Spectroscopy, a well-proven technique for isolating cold molecular species in inert solid environments. COSmIC stands for Cosmic Simulation Chamber. It combines a supersonic free jet expansion with discharge plasma and high-sensitivity cavity ringdown spectroscopy and time-of-flight mass spectrometry detection tools for the generation and the detection of cold, isolated gas-phase molecules and ions under experimental conditions that closely mimic interstellar conditions. The column densities of the individual neutral PAH molecules and ions probed in these surveys are derived from the comparison of these unique laboratory data with high resolution, high S/N ratio astronomical observations. The comparisons of astronomical and laboratory data lead to clear and unambiguous conclusions regarding the expected abundances for PAHs of various sizes and charge states in the interstellar environments probed in the surveys. Band profile comparisons between laboratory and astronomical spectra lead to information regarding the molecular structures and characteristics associated with the DIB carriers in the corresponding lines-of-sight. These quantitative surveys of neutral and ionized PAHs in the optical range open the way for unambiguous quantitative searches of PAHs and complex organics in a variety of interstellar and circumstellar environments.

astrophysics↗

Note: A modular and robust continuous supersonic expansion discharge source

A direct current discharge has been coupled with a continuous supersonic expansion to provide a source of rotationally cold molecular ions for gas phase spectroscopy. Constructed primarily of machinable ceramic and stainless steel, this source design is modular, customizable, and robust. Its performance has been assessed by recording transitions within the {nu}{sub 2} fundamental band of H{sub 3}{sup +} using cavity ringdown spectroscopy to determine the rotational temperature of ions produced in the free-jet expansion. Temperature and column density were recorded as a function of discharge current as the source was operated over a period of 200 h. Observed temperatures ranged between 50-110 K, and the ion column densities between 8x10{sup 10} and 2x10{sup 12} cm{sup -2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensor for Monitoring Nanodevice-Fabrication Plasmas

The term plasma process diagnostics (PPD) refers to a spectroscopic technique and sensing hardware that have been proposed for monitoring plasma processes used to fabricate electronic devices that feature sizes as small as several nanometers. Nanometer dimensions are characteristic of the quantum level of miniaturization, where single impurity atoms or molecules can drastically change the local properties of the nanostructures. Such changes may be purposely used in nanoscale design but may also be extremely damaging or cause improper operation of the fabricated devices. Determination of temperature and densities of reactants near the developing features is important, since the structural synthesis is affected by characteristics of the local microenvironment. Consequently, sensors capable of nonintrusive monitoring with high sensitivity and high resolution are essential for real-time atomistic control of reaction kinetics and minimizing trace contamination in plasma processes used to fabricate electronic nanodevices. Such process-monitoring sensors are required to be compact, multiparametric, and immune to the harsh environments of processing plasmas. PPD is intended to satisfy these requirements. The specific technique used to implement plasma diagnostics with a PPD sensor would be an advanced version of continuous-wave cavity-ringdown spectroscopy (CW-CRDS) capable of profiling spectral line broadenings in order to derive both Doppler and Stark components. CRDS is based on measurements of the rate of absorption of laser light in an optical resonator. The ultimate sensitivity results from a very long absorption path length within the cavity and immunity to variations in incident laser intensity. The proposed version of this technique would involve the use of multiplexing tunable laser diodes and an actively modulated high-reflectivity optical resonator, thus offering a synergistic combination of simplicity, compactness, high sensitivity, and high resolution. The multiplexing capabilities of diode lasers could be utilized to make the PPD sensor a single, simple, compact, and inexpensive tool for the acquisition of multiparametric data. A PPD sensor would be capable of continuous measurement of such physical parameters as gas temperature, gas velocity, electron number density, and absolute densities of reacting chemical species. A laser beam can be easily adjusted to analyze the immediate vicinity of the growing nanostructures (or features etched down) in real time. The absorption enhancement in an optical cavity would afford the sensitivity needed for measurement of the temperature and densities of species at concentrations significantly lower than measurable by other nonintrusive techniques. It is anticipated that fully developed PPD sensors would enable simultaneous measurement of local temperature and determination of plasma species responsible for the synthesis and functionalization of nanodevices. These sensors would also enable tracking the pathways and origins of damaging contaminants, thereby providing feedback for adjustment of processes to optimize them and reduce contamination. The PPD sensors should also be useful for optimization of conventional microelectronics manufacturing plasma processes. Going beyond plasma processes for fabrication of electronic devices, PPD sensors could be used for monitoring of atoms, molecules, ions, radicals, clusters, and particles in a variety of other settings, including outer space. Because of their high sensitivity, such sensors could also prove useful for detecting traces of illegal drugs and explosives.

Bolshakov, Alexander↗