Search NASA⌕ Search

SEARCH · Search NASA

Results for “cell and module performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Improved Primary Reference Cell Calibrations for Higher Accuracy Photovoltaic Cell and Module Performance Measurements

The adoption of photovoltaic (PV) modules for clean electricity relies on accurate measurements of their performance, which are essential for estimating their energy production potential. Herein, the calibration chain of PV cells and modules, with particular emphasis on primary reference cell calibrations, is discussed. Also, herein, the direct sunlight method the group has developed for these calibrations is presented and critical improvements and upgrades that lead to calibration uncertainty as low as 0.45% are discussed. The ultimate motivation behind this work is to provide low‐uncertainty performance measurements of PV modules, and lowering the calibration uncertainty of primary reference cells is a key first step toward achieving this goal. As the use of solar electricity continues to grow, the demand for primary reference cell calibrations inevitably increases beyond what the small handful of primary calibration laboratories can provide today. Therefore, this work can serve as a useful guide for implementing primary PV reference cell calibrations using the outdoor method, as well as outlining the critical elements required to make these calibrations highly accurate.

Osterwald, Carl R.↗

NREL's Cell and Module Performance Group's Asymptotic Pmax Protocol for Perovskite Devices

Perovskite photovoltaic devices have demonstrated a very rapid rise in reported efficiencies. Potentially extreme artifacts which tend to manifest themselves as large hysteresis effects, depending an scan rates and directions and light bias exposure history are often seen. This can make characterization difficult and may have resulted in some exaggerated efficiency reports. NREL's Cell and Module Performance (CMP) group's approach to standardized measurements of perovskites is discussed.

14 SOLAR ENERGY↗

Cracked Solar Cell Performance Depends on Module Temperature

When cells in a crystalline silicon photovoltaic module crack, packaging materials hold the fragments together. Changes in module temperature cause cell fragments to move, allowing cracked metallization to lose and regain contact. We intentionally cracked cells in commercial PV modules and characterized the modules’ temperature-dependent electroluminescence (EL) response. Here we show that (1) metallization makes contact across cracks in a way that is temperature dependent and (2) this contact is not a function of temperature, but is hysteretic. We expect that any electro-optical characterization made at a single temperature will be misleading as to the effects of cracked cells at different temperatures. And we expect that a single temperature sweep cannot fully characterize the temperature dependence of electro-optical performance of modules with cracked cells.

crack↗

Electrochemical Energy Storage for an Orbiting Space Station

The system weight of a multi hundred kilowatt fuel cell electrolysis cell energy storage system based upon alkaline electrochemical cell technology for use in a future orbiting space station in low Earth orbit (LEO) was studied. Preliminary system conceptual design, fuel cell module performance characteristics, subsystem and system weights, and overall system efficiency are identified. The impact of fuel cell module operating temperature and efficiency upon energy storage system weight is investigated. The weight of an advanced technology system featuring high strength filament wound reactant tanks and a fuel cell module employing lightweight graphite electrolyte reservoir plates is defined.

Martin, R. E.↗

Controlled Nucleation and Growth Process of Li 2 S 2 /Li 2 S in Lithium-Sulfur Batteries

Lithium-sulfur battery is a promising next-generation energy storage system because of its potentially three to five times higher energy density than that of traditional lithium ion batteries. However, the dissolution and precipitation of soluble polysulfides during cycling initiate a series of key-chain reactions that significantly shorten battery life. Herein, we demonstrate that through a simple but effective strategy, significantly improved cycling performance is achieved for high sulfur loading electrodes through controlling the nucleation and precipitation of polysulfieds on the electrode surface. More than 400 or 760 stable cycling are successfully displayed in the cells with locked discharge capacity of 625 mAh g -1 or 500 mAh g -1 , respectively. The nucleation and growth process of dissolved polysulfides has been electrochemically altered to confine the thickness of discharge products passivated on the cathode surface, increasing the utilization rate of sulfur while avoiding severe morphology changes on the electrode. More importantly, the exposure of new lithium metal surface to the S-containing electrolyte is also greatly reduced through this strategy, largely minimizing the anode corrosion caused by polysulfides. This work interlocks the electrode morphologies and its evolution with electrochemical interference to modulate cell performances by using Li-S system as a platform, providing different but critical directions for this community.

25 ENERGY STORAGE↗

Reliable Power Rating of Perovskite PV Modules: Preprint

As the perovskite technology is ramping up into commercialization, reliable and accurate power rating of large-size perovskite modules becomes a prominent aspect for its future deployment in the PV market. It is known that the performance calibration of perovskite PV devices is very challenging due to its complex dynamic response during a conventional current-voltage (IV) measurement. PV researchers have previously proposed several steady-state performance calibration methods to reliably extract PV efficiencies, but mostly focus on small area research-type cells. In this paper, we emphasize the importance of reliable performance calibration on large-size perovskite modules. Extending the NREL Cell and Module Performance (CMP) group’s steady-state performance calibration protocol (i.e., Asymptotic PMAX Scan) for perovskite cells to modules, we justify the necessity of reporting steady-state efficiencies for perovskite cells and discuss the challenges of applying this protocol to modules. We also present our protocol for Maximum Power Point Tracking (MPPT), which is a technique often used for performance calibration of perovskite cells and modules, and show a comparison between MPPT and Asymptotic PMAX. Using MPPT we demonstrate the interplay between metastability and degradation in perovskite modules, and emphasize the necessity to develop preconditioning protocols for stabilizing these devices. Our aim is to promote development of consensus protocols for performance calibration of perovskite modules, and to advance their credible power ratings, which will be beneficial to the growth of perovskite technology in the PV market.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Reliable Power Rating of Perovskite PV Modules

As the perovskite technology is ramping up into commercialization, reliable and accurate power rating of large-size perovskite modules becomes a prominent aspect for its future deployment in the PV market. It is known that the performance calibration of perovskite PV devices is very challenging due to its complex dynamic response during a conventional current-voltage (IV) measurement. PV researchers have previously proposed several steady-state performance calibration methods to reliably extract PV efficiencies, but mostly focus on small area research-type cells. In this paper, we emphasize the importance of reliable performance calibration on large-size perovskite modules. Extending the NREL Cell and Module Performance (CMP) group's steady-state performance calibration protocol (i.e., Asymptotic P MAX Scan) for perovskite cells to modules, we justify the necessity of reporting steady-state efficiencies for perovskite cells and discuss the challenges of applying this protocol to modules. We also present our protocol for Maximum Power Point Tracking (MPPT), which is a technique often used for performance calibration of perovskite cells and modules, and show a comparison between MPPT and Asymptotic P MAX . Using MPPT we demonstrate the interplay between metastability and degradation in perovskite modules, and emphasize the necessity to develop preconditioning protocols for stabilizing these devices. Our aim is to promote development of consensus protocols for performance calibration of perovskite modules, and to advance their credible power ratings, which will be beneficial to the growth of perovskite technology in the PV market.

perovskite↗

Setting the Bar for Device Performance of Photovoltaic Cells and Modules

Cutting-edge photovoltaic (PV) research and development benefits from NREL's world-record accuracy in device performance measurements. NREL is a global leader for PV calibration services to help control manufacturing quality, assess degradation rates, and develop new technologies.

14 SOLAR ENERGY↗

Block V module program

An outlined overview of this module program is given. Tables are given for the following characteristics: module power trend, packing factor trend, cell and circuit characteristics, module physical characteristics, electrical performance, cell efficiency trend, module efficiency trend and module cost trend. The principal improvements are larger modules and higher performance.

Smokler, M. I.↗

Measurements and Characterization (Revised) (Fact Sheet)

Capabilities fact sheet for the National Center for Photovoltaics: Measurements and Characterization that includes scope, core competencies and capabilities, and contact/web information for Analytical Microscopy, Electro-Optical Characterization, Surface Analysis, and Cell and Module Performance.

14 SOLAR ENERGY↗

Impact of Different Thermal Gradients on the Dynamics of Cylindrical Lithium-ion Cells Subject to Accelerated Aging and on Module Performance

This study investigates the impacts of applying different thermal gradient patterns to cylindrical lithium-ion cells in a module on cell dynamics (temperatures, current flows, state of charge), module performance (evolution of resistance, capacity, and energy versus cycle number), and module lifetime. The thermal gradients were generated using cooling plates (CPs) with three different flow-field designs, namely, straight, perpendicular, and U-turn. The study uses computational fluid dynamics (CFD), the pseudo-two-dimensional (P2D) battery model, capacity loss and increased impedance due to the growth of a solid-electrolyte-interphase, and the electric current distribution from module terminals to cells that depends on the series-parallel electrical connections among the cells. The impact of the thermal gradient (resulting from the CP designs) on the variability in resistance, current, state of charge, and voltage among the cells was analyzed and linked to differences in the module's performance. Applying a thermal gradient to parallel-connected strings of series-connected cells led to variation in the current through each parallel string and an imbalance in the voltage of series-connected cells. Module performance is poorer when the thermal gradient causes a voltage imbalance than when it causes a current imbalance. Module performance becomes the worst when both current variation and voltage imbalance happen together. For instance, the module's lifetime (estimated as reaching 80% of its initial capacity) varied by 5% to 17.5%, depending on the magnitude and pattern of the imposed thermal gradient. As the relative orientation between thermal gradients and cells' electrical connectivity influences the module's performance, appropriate consideration should be given to the choice of the CP, especially if large thermal gradients are allowed.

Battery thermal management↗

Thermally Conductive Backsheets (TCB) for Reduced Operating Temperatures

The performance of photovoltaic (PV) modules is primarily influenced by the plane of array (POA) irradiance and their operating temperature. The lower the module operating temperature, the higher is its performance. Increasing a module’s operating temperature reduces its power output due to an increase in the semiconductor’s intrinsic carrier density, leading to a reduction in the open-circuit voltage and, subsequently, reducing the maximum power point voltage. Reducing the operating temperature lowers the levelized cost of energy (LCOE) via increased energy production (i.e., more kilowatt hour over the life of the asset) and increased service lifetime (years in the field). The module operating temperature is dictated by the weather parameters and the thermal properties of module construction materials. The primary weather parameters influencing the PV module temperature are: the ambient temperature (directly related), irradiance (directly related), and wind speed (inversely related). The primary thermal properties of module construction materials influencing the PV module temperature are: the optical transmissivity and thermal conductivity of superstrate, the thermal conductivity of substrate, the thermal conductivity of encapsulant and the efficiency of the encapsulated solar cells. The primary goal of this study is to reduce the operating temperature of PV modules using thermally conductive backsheet (TCB) substrates developed by the industry. The temperature of PV modules installed in a large multi-MW plant can also be influenced by their physical locations in the plants due to the influence of wind direction. A thermal mapping of PV plants has also been investigated and presented in this study. The most commonly used PV backsheet material has been polyvinyl fluoride (DuPont trade name “Tedlar”)-based backsheet, which typically has three layers: Tedlar–polyethylene terephthalate (PET)–Tedlar (TPT). The primary goal of this project is to reduce the module operating temperature below the benchmark TPT backsheet temperature using newly developed TCBs by the industry. The overall approach of this project involves six focus areas: i) select and procure one TPT and thirteen promising TCBs available in the industry; ii) construct a large number of 1-cell and 9-cell modules using benchmark TPT and selected TCBs [all other construction materials are fixed and they are: glass superstrate, EVA encapsulant, mono-Si cell and junction box]; iii) to identify best performing TCBs, monitor the long-term field operating temperatures of the constructed modules which are installed in three climatic conditions (hot-low wind [Mesa, AZ], hot-high wind [Maricopa County, AZ] and temperate [Cumberland County, NC]; iv) to identify the most durable TCB, perform extended accelerated reliability testing of modules constructed with best three TCBs and benchmark TPT; v) to predict module temperature, develop physical and empirical thermal models with and without thermal properties of all construction materials in the modules, respectively; and vi) to determine the influence of wind speed and direction on the module operating temperature in a plant, and perform thermal mapping of PV modules in two large PV plants [Maricopa County, AZ and Cumberland County, NC]. The key achievements of this project are listed below: Backsheet selection: 14 backsheets were procured after an extensive literature and industry search. Finally, based on the thermal and other selection criteria, 1 TPT and 4 thermally conductive backsheets were selected for this project. Fabrication of mini modules: 50 one-cell modules were fabricated in year 1 for thermal performance evaluation. The module design was changed to nine-cell module at start of year 2 to mimic commercial design. 20 nine-cell modules were fabricated in year 2 for thermal performance evaluation. 28 four-cell modules were fabricated in year 3 for accelerated stress-testing. Thermal conductivity of backsheets: Year 1 TCBs showed at least 8% higher thermal conductivities than TPT. Year 2 and 3 TCBs showed at least 20% higher thermal conductivities than TPT. Installation of mini PV modules at three sites: 6 one-cell modules and 8 nine-cell modules were installed at AZ-1 site [Mesa, AZ]. 12 one-cell modules and 6 nine-cell modules were installed at each of two powerplants (AZ-2 [Maricopa County, AZ] and NC sites). Nominal operating cell temperatures (NOCT) of mini PV modules: NOCT of TCBs were observed to be lower than TPT with differences as high as 2°C. Comparison of thermal performance: The median operating temperature of one-cell modules was found to be reduced by 2°C by using TCB_A modules compared to TPT modules on several days in a month for few months in a year. The median temperature improvement of 4oC was achieved at several instances on a few days, but not all days, in a year using multiple TCBs compared to TPT. The final project milestone of achieving median temperature improvement of 5oC was achieved at several instances on a few days, but not all days, in a year using TCB_A compared to TPT. Empirical thermal model (without the need of construction material properties): Empirical thermal model for one-cell module was developed based on the input data of irradiance, wind speed and ambient temperatures. The primary input data differentiator for temperature differences between TPT and TCBs appears to be the irradiance level (solar gain). Accelerated durability testing: 20 four-cell modules using 4 backsheets (1 TPT and 3 TCBs) were exposed to Damp Heat 1000 hours (8 modules), UV/Thermal cycling (50 cycles)/Humidity freeze (10 cycles) test sequence (8 modules) and UV Weathering for qualification (8 modules). All the modules with four selected backsheets passed the stress tests per the retest guidelines of IEC 61215 standard for the backsheet change. Simplified comparative LCOE analysis: Using backsheet-specific power degradation levels in the accelerated tests (for TCB_A and TPT only), efficiency, service lifetime and assuming same cost for all backsheets, the LCOE of modules using TCB_A is determined to be lower than TPT. Due to lower operating temperature of TCB_A-based modules compared to TPT-based modules, the operating efficiency and service life of TCB_A-based modules are calculated to be higher than TPT-based modules. Temperature mapping of PV power plants: A distinct temperature difference (as high as 4°C) has been observed between the modules located in various parts of a single PV plant.

14 SOLAR ENERGY↗

Advancements in Manufacturing of High-Performance Perovskite Solar Cells and Modules Using Printing Technologies

Perovskite photovoltaic technology carries immense opportunity for the solar industries because of its remarkable efficiency and prospect for cost-effective production. However, the successful deployment of perovskite solar modules (PSMs) in the solar market necessitates tackling stability-based obstacles, scalability, and environmental considerations. This paper unveils a comprehensive examination of the cutting-edge advancements in the manufacturing of perovskite solar cells (PSCs) and modules, with an emphasis on high-speed, large-area printing. The paper underscores the substantial progress achieved in printed PSCs and PSMs, demonstrating promising electrical performance and long-term device durability. This review paper categorizes printing techniques compatible with large-area high-speed manufacturing into three distinct families: blade coating, slot die coating, and screen printing, as these common printing practices offer precise control, scalability, cost-effectiveness, high resolution, and efficient material usage. Additionally, this paper presents an in-depth investigation and comparison of superior PSCs and PSMs fabricated by printing on power conversion efficiency (PCE), stability, and scalability.

14 SOLAR ENERGY↗

Measurements of Six-Junction Concentrator Solar Cells

Accurate measurements of six-junction inverted metamorphic concentrator solar cells under AM1.5 direct spectrum are obtained by adjusting the spectrum of a tunable high-intensity solar simulator with custom mirrors. Isotype reference cells and broadband InGaAs QE calibration cells were developed for accurate measurements. Modeling and varying the illumination show that an unavoidable 15% - 17% overillumination on the sixth junction does not result in significant error of these 6J IMM devices. Spectrally adjusted flash measurements are independently confirmed by NREL's Cell and Module Performance team. Concentration measurements of a 6J IMM solar cell resulted in 47.1 ± 3.2% (absolute) efficiency at 143 suns.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Block 2 solar cell module environmental test program

Environmental tests were performed of on 76 solar cell modules produced by four different manufacturers. The following tests were performed: (1) 28 day temperature and humidity; (2) rain and icing; (3) salt fog; (4) sand and dust; (5) vacuum/steam/pressure; (6) fungus; (7) temperature/altitude; and (8) thermal shock. Environmental testing of the solar cell modules produced cracked cells, cracked encapsulant and encapsulant delaminations on various modules. In addition, there was some minor cell and frame corrosion.

Holloway, K. L.↗