Search NASASearch

SEARCH · Search NASA

Results for “cement plant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Implementing Large-Scale CCS in Complex Geologic Reservoirs: Insights from Three Appalachian Basin Case Studies

This paper presents three design case studies for implementing large-scale geologic carbon storage in the Appalachian Basin region of the midwestern United States. While the Appalachian Basin has a challenging setting for carbon storage, the three case studies detailed in this article demonstrate that there are realistic options for implementing carbon storage in the basin. Carbonate rock formations, depleted hydrocarbon reservoirs, and moderate-porosity sandstones can be utilized as carbon-storage reservoirs in the Appalachian Basin. While these are not typical concepts for CO2 storage, the storage zones have advantages such as defined trapping mechanisms, multiple caprocks, and defined boundaries that are not always present in thick, permeable sandstones being targeted for many carbon-storage projects. The geologic setting, geotechnical parameters, and hydrologic setting for the three case studies are provided, along with the results of reservoir simulations of the CO2 injection-deployment strategies. The geological rock formations available for CO2 storage in the Appalachian Basin are more localized reservoirs with defined boundaries and finite storage capacities. Simulation results showed that accessing carbon-storage resources in these fields may require wellfields with 2–10 injection wells. However, these fields would have the capacity to inject 1–3 million metric tons of CO2 per year and up to 90 million metric tons of CO2 in total. The CO2 storage resources would fulfill decarbonization goals for many of the natural-gas power plants, cement plants, hydrogen plants, and refineries in the Appalachian Basin region.

Sminchak, Joel

Carbon Capture Plant Front-End Engineering Design Study for Cement Manufacturing

The objective of this project was to conduct a Front-End Engineering Design (FEED) study for capturing carbon dioxide (CO₂) from cement plant flue gas using non-aqueous solvents (NAS) with a 95% capture efficiency. The study aimed to develop AACE (Association for the Advancement of Cost Engineering) Class 3 cost estimates for a commercial-scale CO₂ capture system with a capacity of 2.4 million tonnes of CO₂ per year (t-CO₂/yr). The results will provide Cemex and the U.S. Department of Energy with reliable data to support investment decisions, evaluate economic feasibility, and guide future project development and implementation.

20 FOSSIL-FUELED POWER PLANTS

Mitchell FEED Study Summary Report (Unlimited Rights Version) (Rev. D)

Heidelberg Materials (HM), Sargent & Lundy (S&L), and Mitsubishi Heavy Industries (MHI) completed a Front End Engineering Design (FEED) study for deployment of an amine-based CO 2 capture system at the Mitchell Cement Plant in Indiana. The project includes compression of captured CO 2 to a supercritical state for geological sequestration. The flue gases from 7,000 mtpd clinker plant combined with auxiliary boiler flue gases into the capture system. Auxiliary boiler supplies steam for solvent regeneration. The study developed an AACE Class 3 capital cost estimate (+30%/-20%) at approximately 30% design completion to evaluate the technical and economic feasibility of capturing up to 2 million tonnes of CO 2 per year.

42 ENGINEERING

Air Emissions Impacts of Fuel Substitution in the United States Cement Industry

High-heat industrial processes cannot be easily electrified, often rely on comparatively high-emitting solid fuels, and are essential for economic growth. Cement production in particular is critical to supporting construction and the expansion and maintenance of infrastructure systems in countries around the world. Fuels for cement production include petcoke, coal, and waste solvents, and their combustion contributes approximately 40% of the CO 2 emissions from global cement production. Broadening the fuel resources to include agricultural residues and other wastes can reduce emissions and divert waste from landfills. We assess the potential to use 16 different alternative fuels across the 88 integrated cement plants in the United States. The share of alternative fuels in the cement production sector could increase from the current level of 17% to as high as 73%. Fuel substitution can reduce the current fuel-related life-cycle emissions (28.6 ± 5.7 Mton CO 2 /year) by 19–45%. The greatest national-scale human health cobenefits occur when alternative fuels are prioritized at facilities currently using coal and petcoke. NO x emissions outcomes from this strategy are mixed, but SO x and particulate matter emissions reductions drive net human health benefits. These results suggest that targeted fuel substitution in heavy industries can yield outsized emissions benefits.

alternative fuels

Facies Analysis of the Prairie Du Chien Group in the Illinois Basin and Analogous Rocks in Missouri and Kentucky

Funded in 2023 by the U.S. Department of Energy’s Phase II Carbon Storage Assurance Facility Enterprise (CarbonSAFE) initiative, a Heidelberg Materials cement plant in Mitchell, Indiana, is currently being evaluated as a potential Carbon Capture and Storage (CCS) subsurface injection site. The Heidelberg CCS project targets the middle to upper Prairie du Chien Group (Early Ordovician) in southwestern Indiana. Assessment of reservoir feasibility requires collection of field data, seismic surveys, well-log correlation, geologic modeling, characterization well drilling, well testing, and reservoir simulation. However, the proposed Heidelberg CCS site is in a data-limited region, lacking both outcrop analogs and deep wells penetrating the target interval, which makes geologic modelling difficult prior to drilling a characterization well. To directly address this problem, the present study was undertaken to understand the sedimentologic composition and stratigraphic architecture of the Prairie du Chien Group from analogous outcrops and cores in the Illinois Basin and adjacent regions.

Ali, Shah Bilawal [Univ. of Illinois at Urbana-Cha

Standard Analysis Report INV-SAR-81, Revision 0 Chemical and Cement Components 2023 Inventory Estimates for the Interim State Performance Assessment of the Waste Isolation Pilot Plant

This standard analysis report provides the estimates for the chemical (oxyanions and complexing agents) and cement components with a data collection cut-off date of December 31, 2023. These estimates will be included in a Performance Assessment Inventory Report developed for the U.S. Department of Energy (DOE) interim state repository configuration performance assessment (PA) for the 2026 Compliance Recertification Application (CRA).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Coal Ash Beneficial Use at Savannah River Site

The Savannah River Site (SRS) has over 1.4 million cubic meters of coal ash and coal fines left over from coal-burning power plants that operated on site. Currently, the coal ash must be disposed of in an approved landfill or the coal ash-containing basins must be closed in place (i.e. consolidation, appropriate cover and liner system). Potential beneficial uses of the coal ash include geotechnical fill, such as backfill needed in the closure cap of the Z-area Saltstone Disposal Units (SDU), and use in cementitious material applications like thermal beneficiation or cement kiln feed, thereby reducing the environmental footprint of SRS. In this study, samples of coal ash from SRS were obtained and characterized for chemical and physical properties. Coal ash samples did not leach sulfates or heavy metals, so the coal ash is a candidate for geotechnical fill use. The samples also did not increase the acidity of the leachate during leaching tests, so it would not be detrimental to use as geotechnical fill near cementitious materials. The composition and energy potential of the coal ash makes it favorable for use as feed for external/off-site cement kilns or thermal beneficiation plants

01 COAL, LIGNITE, AND PEAT

State of Innovation 2025: Progress in Accelerating Next-Generation Cement and Concrete Technologies

The cement and concrete sectors are entering a decisive period as next-generation technologies advance from laboratory research to demonstration, early deployment, and first-of-a-kind commercial plants. Building on the 2024 State of Innovation report, the 2025 outlook highlights both the rapid acceleration of innovation and the urgent need for coordinated action across the value chain. Venture capital activity into the cement and concrete space stabilized following the record surge of 2022-2023, yet landmark financings, such as Sublime Systems' $200 million round and Terra CO2's $124 million Series B, signal continued investor confidence in companies approaching commercialization. Corporate procurement has become a powerful new catalyst, with Microsoft, Amazon, and CRH (Cement Roadstone Holdings) Ventures providing long-term commitments that underpin the first wave of next-generation cementitious products. The sector is shifting from early-stage experimentation toward the scaling of well-capitalized leaders capable of bridging the critical "capitalization gap." Early innovators continue to expand the toolkit through novel binders, electrochemical cements, biogenic limestone, and carbonate mineralization pathways. Going into 2026, cost competitiveness, durability validation, and scalability enabled by resilient supply chains remain the decisive factors for market adoption. At the 2025 Next Generation Cement and Concrete Critical Technologies Meeting, attendees emphasized dual-track funding strategies that integrate federal grants with private capital as key to enabling market breakthrough. State programs and corporate demand are sustaining momentum, while successful companies increasingly demonstrate both economic value and reduced dependence on imported materials. The National Concrete Pavement Technology Center and others underscored that broad integration of next-generation materials will hinge on standards compatibility, verified field performance, and workforce readiness. Colorado continues to serve as a proving ground through pilot programs that combine supplier training, phased implementation, and real-world data to de-risk innovation and provide replicable models for other regions. The 2025 Cement and Concrete Critical Technologies Workshop reinforced that scaling next-generation materials will require alignment among technology innovation, performance validation, and market demand. Stakeholders must move beyond siloed efforts toward collaborative frameworks that coordinate standards, funding, and infrastructure deployment. As a neutral convener and technical validator, the National Laboratory of the Rockies (NLR) plays a pivotal role in bridging innovation and market adoption through collaborative research, technology validation, and entrepreneurship programs. By uniting innovators, incumbents, policymakers, contractors, and investors, NLR and its partners are helping chart a credible pathway toward widespread commercialization in the decade ahead.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

LDR Inorganic Spiked Simulants in Pozzolan-Substituted Cast Stone for Hanford Pretreated Low-Activity Tank Waste

Pretreated Low Activity Waste (PTW/LAW) at the Hanford Site, is currently projected for disposition through a cementitious waste form. The current standard formulation, Cast Stone, uses Class F fly ash, blast furnace slag, and Portland cement. However, the future availability of Class F fly ash is uncertain, as many coal-fired power plants—the source of this byproduct—are being decommissioned or converted to natural gas. This issue has prompted research into identifying and evaluating suitable alternative materials to replace fly ash in the cementitious waste forms used by the Department of Energy (DOE). The Savannah River National Laboratory (SRNL) successfully identified four natural pozzolans for the replacement of Class F fly ash in the current Savannah River Site (SRS) low-level waste (LLW) form, Saltstone.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Evaluation of Pozzolan-substituted Cast Stone for Pretreated Hanford Tank Waste

Portland cement. The future availability of quality Class F fly ash has come into question as coal-fired power plants are being converted to gas or taken offline. Consequently, alternative pozzolanic reagents are being evaluated for fly ash replacement in cementitious matrices for treating radioactive waste and debris. In 2023 and 2024, Savannah River National Laboratory (SRNL) was funded to evaluate natural pozzolans for the replacement of Class F fly in the Savannah River Site (SRS) Saltstone formulation. Based on the promising results and uncertain availability of Class F fly ash in the northwestern US, Hanford Tank Waste Operations & Closure, LLC (H2C) requested SRNL to evaluate the potential for substituting natural pozzolans in the Hanford West Area Pretreated Low Activity Tank Waste (PTW/LAW) Cast Stone formulation1 . Task 1 in this request was to determine the change in Cast Stone volume resulting from stabilization/solidification of 1 L of PTW/LAW tank waste. The densities of three (Hess Pumice, tephra pumice, and clinoptilolite zeolite) pozzolan-substituted Baseline Cast Stone mixes were determined, and volume changes relative to the fly ash-Baseline Mix with a water-to-dry mix = 0.40 were calculated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Quantifications of growth rate and particle size of magnesium silicate hydrate cement using small‐angle X‐ray scattering

The focus of recent research on cement binders has shifted to alternatives such as magnesium silicate hydrate (M-S-H) to mitigate the environmental impact of conventional concrete production. However, a detailed understanding of the morphology and growth rate of M-S-H, which informs its applicability as a cementing agent, is lacking. These properties are important as they influence cement hydration and consequently the development of macroscopic properties. Here, in this study, the particle size distribution and growth rate of M-S-H synthesized by mixing aqueous stock solutions were analyzed using synchrotron-based small-angle X-ray scattering. The reaction solutions contained dissolved magnesium and silicon with concentrations ranging from 2 to 500 mM, corresponding to saturation indices with respect to M-S-H endmembers, M 0.75 -S-H and M 1.50 -S-H, between 5.8 and 10.3. The precipitation rates of M-S-H align with affinity-based kinetic models and can be described by the following equations: For M 0.75 -S-H: 𝑟 M 0.75 −S−H =10 −9.54±0.70 ⁢(Ω$^{0.59±0.08}_{M_{0.75}⁢\textrm{SH}}$−1), and for M 1.50 -S-H: 𝑟 M 1.50 −S−H =10 −7.56±0.37 ⁢(Ω$^{0.34±0.04}_{M_{1.50}⁢\textrm{SH}}$−1), where 𝑟 is the rate in mol/L/s, and Ω represents the saturation ratio with respect to M-S-H. Moreover, we observed that changing the [Mg]/[Si] ratio affects particle size, a trend that cannot be fully explained by changes in the saturation index alone. These insights are critical for improving the predictability and control of cementation in concrete that utilizes M-S-H-based binders.

M-S-H

Replacement of Fly Ash with Natural Pozzolans in Cementitious Waste Forms

OBJECTIVE Address long-term and emerging issues for Cementitious Waste forms • Future availability of fly ash from coal fired power plants is uncertain • Improve waste form properties • Regionally available ingredients • Reduce cost and embodied Energy • Increase Salt Solution Waste Loading (water : cementitious reagents) in cement waste forms

Hill, Katie A. [Savannah River National Laboratory

Predictive Assessment of the Chemical Composition of Coal Ash in Reserve at U.S. Disposal Sites

In the United States, more than 2 Gt of coal combustion residuals (i.e., coal ash) are stored in hundreds of disposal units. Recent federal regulations mandate the closure or retrofitting of most coal ash impoundments, presenting significant challenges for waste management. These regulatory pressures also present opportunities to reuse coal ash. However, the quality and quantity of discarded coal ash across the U.S. are not well known, even though this information is crucial for spurring its reuse for conventional and new material applications. This study describes a predictive model for the major element composition of coal ash in reserve at disposal sites of major U.S. coal-fired power plants. This model was constructed from coal purchase records of 705 power stations from 1973 to 2022 and was trained on coal ash composition data, showing that coal ash elemental composition is strongly associated with the source of feedstock coal. The model showed regional shifts in the major element contents of ash produced by power plants in the last 50 years, particularly for calcium and iron (expressed as %CaO and %Fe2O3), as power stations changed their source of coal over this time frame. Our approach enables an estimation of chemical composition for ash stored in waste impoundments at individual power stations. Such information can help to delineate the regional market resource potential of supplementary cements for concrete and other material innovations that would utilize coal ash harvested from disposal sites across the U.S.

01 COAL, LIGNITE, AND PEAT

Peridynamic modeling of cementitious materials for nuclear waste management

Radioactive and hazardous waste generated from fuel processing plants, nuclear reactors, and hospitals, requires effective management strategies. Cementitious materials are widely applied for these needs, serving as structural materials, reactive barriers, or waste forms. In these applications cracking poses a significant risk to performance, driven by inconsistent shrinkage of the components and the varying strength and permeability of their interfaces. Traditional modeling approaches face challenges in representing the complex fracture behavior of cementitious materials due to the reliance on spatial derivatives and difficulties with mesh generation. Here, to overcome these limitations, we employ peridynamics, a novel continuum mechanics formulation that uses integrals to describe mechanical equilibrium, avoiding discontinuities associated with traditional methods. Through incorporation of a bi-linear softening model and quasistatics, an experimentally validated model for Portland cement concrete samples was created. Mechanical parameters, including compressive strength and elastic modulus were validated and variation due to aggregate packing was evaluated. Additionally, sensitivity analysis of the peridynamic parameters to the bulk material properties was established. The results lay the groundwork for evaluating the impact of unique conditions of cementitious waste forms that can be assessed to improve the reliability of waste management strategies.

Aggregates

Solar Heat for Industrial Processes: Integration with Chemical Reactors

The integration of solar thermal systems with chemical reactors has been proposed as part of a larger effort to develop and deploy solar heat for industrial processes (SHIP) technologies. A strong motivation for SHIP processes and technologies is the potential for high thermal efficiency coupled with low-cost thermal energy storage (TES) which can enable commercial deployment of such systems. While there are different ways to categorize SHIP technologies, one important such distinction is between directly irradiated systems and indirect off-sun process driven by a SHIP system. While directly irradiated systems can provide high thermal efficiencies and high fluxes, they usually require complex engineering solutions due to the need for redesigning the established processes and unit operations. In most cases, it is also more challenging to couple such a process to a TES system, losing some of the benefits of SHIP. On the other hand, using a SHIP system to drive an industrial process off-sun can allow better integration with existing process chains, easier TES capabilities, and potential for more applications fitting a specific SHIP technology. However, the integration of SHIP systems with the industrial processes is not fully explored in detail, especially in the case of high-temperature processes such as reforming, cracking, cement manufacturing, and iron/steelmaking. Many of these systems require heating fluxes of >50 kW/m^2, supplied via combustion of hydrocarbons in a fire box and benefitting from radiative heat transfer between the flue gases and the reaction zones. As such, using SHIP systems for such processes is more complex than providing the same thermal input in the form of a heat transfer medium (HTM) entering the reactor, kiln, or furnace. Moreover, in case convective heat transfer using SHIP is envisioned, for example using supercritical CO2 as the HTM from a particle receiver, the thermal integration might be more challenging than initially envisioned: lower heat transfer coefficients and limited approach temperature might require large flow rates, causing a mismatch between the process thermal requirements and the thermal capacity of the SHIP system. In addition, even if the heat exchange between SHIP and reactor is effective, there is still a cold leg HTM at the reaction temperature or slightly below it. Chemical plants usually include a set of heat exchangers, heat recovery steam generators, and even power generation units - in a tightly integrated design - to recover the flue gases which are eventually vented. With SHIP systems mostly operating on a closed HTM loop, bottoming the cold leg is crucial. In this talk, we will present different modeling results for a variety of syngas production reactions, using catalytic and chemical looping processes, and discuss some of the challenges and design considerations for off-sun chemical reactors using SHIP systems.

14 SOLAR ENERGY

Insights from Initial Engineering Designs of Point Source Capture at Industrial Facilities

Initial engineering design studies examining the application of state-of-the-art carbon capture technology at industrial plants contain generally overlooked real-world design considerations for near-term deployment of point source capture (PSC). The implementation of PSC across a wide range of industrial applications presents unique challenges associated with fluctuating CO<sub>2</sub> concentrations, flue gas composition, and utility and land availability. In this article, seven recent industrial retrofit PSC projects are reviewed to investigate the impact of site-specific factors on project design and cost. Across the seven projects, three capture technology classes and four industrial applications are considered, allowing insight into industry-specific opportunities for PSC technology synergy. Common challenges across projects and proposed design solutions are highlighted to propagate ideas and solutions to close the technology gaps and accelerate learning rates.

FEED Studies

Foam and Unreacted Material Reduction in Magnesium Oxysulfate for SRPPF Waste Solidification

A magnesium oxysulfate (MOS) grout formulation has been proposed to solidify the liquid effluent from the Savannah River Plutonium Processing Facility (SRPPF) Aqueous Recovery System (ARS). This formulation uses a combination of light-burnt MgO, anhydrous MgSO 4 , and dead-burnt MgO resulting in a grout with good mixability and acceptable density. The setting time for the grout is within the operational limits of the SRPPF facility and the leachate pH is ~9.4, which is within the assumed pH range of the brine from the Waste Isolation Pilot Plant (WIPP). When first tested at the 1-gallon small-scale and 55-gallon full-scale, there was a significant foam layer that raised concerns of a nonhomogeneous final form. A nonhomogeneous mixture could have variable density throughout the waste form and therefore allow for unequal shielding. To reduce the potential for unequal shielding in the final form, a series of foam reduction tests were carried out and a final formulation of 28 wt% light burnt MgO, 10 wt% MgSO 4 , and 62 wt% dead burnt MgO was used to remove the foam in under two hours while still maintaining a mix that has an acceptable density, mix time, peak temperature, and set time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W