Search NASA⌕ Search

SEARCH · Search NASA

Results for “center wavelengths”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Temperature dependence of the properties of DBR mirrors used in surface normal optoelectronic devices

The variation in the center wavelength of distributed Bragg reflectors used in optoelectronic devices, such as surface emitting lasers and Fabry-Perot modulators, is measured as the temperature of the mirrors changes over the range 25 C to 105 C. An analytic expression for the shift in center wavelength with temperature is presented. The mirrors measured are made of InP/InGaAsP, GaAs/AlAs, and Si/SiN(x). The linear shifts in center wavelength are 0.110 +/- 0.003 nm/C, 0.087 +/- 0.003 nm/C, and 0.067 +/- 0.007 nm/C for the InP/InGaAsP, GaAs/AlAs, and Si/SiN mirrors, respectively. Based on these data, the change in penetration depth with temperature is calculated.

Dudley, J. J.↗

MODIS On-orbit Spectral Calibration for the Reflective Solar Bands

The Moderate Resolution Imaging Spectroradiometer (MODIS) makes observations in 36 spectral bands with wavelengths from 0.41 to 14.5 microns. The bands with center wavelengths below 2.2 microns are referred as the reflective solar bands (RSB) with their radiometric calibration performed by a solar diffuser (SD) and a solar diffuser stability monitor (SDSM). This paper focuses on the MODIS spectral calibration performed by its unique on-board calibrator (OBC): the Spectro-Radiometric Calibration Assembly (SRCA). When operated in the spectral mode, the SRCA acts as a monochromator with internal spherical integration source (SIS) that measures the spectral responses for all the reflective solar bands. A wavelength calibrator, a didymium filter with known spectral profile, is utilized to calibrate the wavelength scale for the grating positions during each SRCA spectral calibration activity. The capability of self-wavelength calibration allows the SRCA to track the center wavelength shifts and to monitor the spectral response changes throughout the instruments lifetime. The MODIS spectral calibration, same for both Terra and Aqua missions, is performed every three months on-orbit. An overview of MODIS spectral characterization approach and a summary of the on-orbit results will be presented in this paper.

Xiong, X.↗

VIIRS Reflective Solar Band Radiometric and Stability Evaluation Using Deep Convective Clouds

This work takes advantage of the stable distribution of deep convective cloud (DCC) reflectance measurements to assess the calibration stability and detector difference in Visible Infrared Imaging Radiometer Suite (VIIRS) reflective bands. VIIRS Sensor Data Records (SDRs) from February 2012 to June 2015 are utilized to analyze the long-term trending, detector difference, and half angle mirror (HAM) side difference. VIIRS has two thermal emissive bands with coverage crossing 11 microns for DCC pixel identification. The comparison of the results of these two processing bands is one of the indicators of analysis reliability. The long-term stability analysis shows downward trends (up to approximately 0.4 per year) for the visible and near-infrared bands and upward trends (up to 0.5per year) for the short- and mid-wave infrared bands. The detector difference for each band is calculated as the difference relative to the average reflectance overall detectors. Except for the slightly greater than 1 difference in the two bands at 1610 nm, the detector difference is less than1 for other solar reflective bands. The detector differences show increasing trends for some short-wave bands with center wavelengths from 400 to 600 nm and remain unchanged for the bands with longer center wavelengths. The HAM side difference is insignificant and stable. Those short-wave bands from 400 to 600 nm also have relatively larger HAM side difference, up to 0.25.Comparing the striped images from SDR and the smooth images after the correction validates the analyses of detector difference and HAM side difference. These analyses are very helpful for VIIRS calibration improvement and thus enhance product quality

VIIRS↗

Widely Tunable Mode-Hop-Free External-Cavity Quantum Cascade Laser

The external-cavity quantum cascade laser (EC-QCL) system is based on an optical configuration of the Littrow type. It is a room-temperature, continuous wave, widely tunable, mode-hop-free, mid-infrared, EC-QCL spectroscopic source. It has a single-mode tuning range of 155 cm(exp -1) (approximately equal to 8% of the center wavelength) with a maximum power of 11.1 mW and 182 cm(exp -1) (approximately equal to 15% of the center wavelength), and a maximum power of 50 mW as demonstrated for 5.3 micron and 8.4 micron EC-QCLs, respectively. This technology is particularly suitable for high-resolution spectroscopic applications, multi-species tracegas detection, and spectroscopic measurements of broadband absorbers. Wavelength tuning of EC-QCL spectroscopic source can be implemented by varying three independent parameters of the laser: (1) the optical length of the gain medium (which, in this case, is equivalent to QCL injection current modulation), (2) the length of the EC (which can be independently varied in the Rice EC-QCL setup), and (3) the angle of beam incidence at the diffraction grating (frequency tuning related directly to angular dispersion of the grating). All three mechanisms of frequency tuning have been demonstrated and are required to obtain a true mode-hop-free laser frequency tuning. The precise frequency tuning characteristics of the EC-QCL output have been characterized using a variety of diagnostic tools available at Rice University (e.g., a monochromator, FTIR spectrometer, and a Fabry-Perot spectrometer). Spectroscopic results were compared with available databases (such as HITRAN, PNNL, EPA, and NIST). These enable precision verification of complete spectral parameters of the EC-QCL, such as wavelength, tuning range, tuning characteristics, and line width. The output power of the EC-QCL is determined by the performance of the QC laser chip, its operating conditions, and parameters of the QC laser cavity such as mirror reflectivity or intracavity losses. In order to maximize the output power, an analysis and optimization of the EC laser parameters has been performed. The parameters of the beam emitted from the gain medium, such as divergence angle, beam profile, and astigmatism, have been investigated. The gain medium has been fully characterized before and after each stage of modification. The main modification steps are coating one facet of the gain chip with a high reflectivity mirror and the other facet with an anti-reflection layer. Then the chip is mounted in the EC-QCL. The optomechanical design has been reviewed and improved to provide for precise collimation of the strongly divergent beam of the QCL and the tuning diffraction grating.

Wysocki, Gerard↗

Problems in the use of interference filters for spectrophotometric determination of total ozone

An analysis of the use of ultraviolet narrow-band interference filters for total ozone determination is given with reference to the New Zealand filter spectrophotometer under the headings of filter monochromaticity, temperature dependence, orientation dependence, aging, and specification tolerances and nonuniformity. Quantitative details of each problem are given, together with the means used to overcome them in the New Zealand instrument. The tuning of the instrument's filter center wavelengths to a common set of values by tilting the filters is also described, along with a simple calibration method used to adjust and set these center wavelengths.

Basher, R. E.↗

SeaWiFS Technical Report Series: SeaWiFS Calibration Topics - Volume 39

For Earth-observing satellite instruments, it was standard to consider each instrument band to have a spectral response that is infinitely narrow, i.e., to have a response from a single wavelength. The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) bands, however, have nominal spectral bandwidths of 20 and 40nm. These bandwidths affect the SeaWiFS measurements on orbit. The effects are also linked to the manner in which the instrument was calibrated and to the spectral shape of the radiance that SeaWiFS views. Currently, SeaWiFS is calibrated such that the digital counts from each instrument band are linked to the Earth-exiting radiance at an individual center wavelength. Before launch, SeaWiFS will be recalibrated so that the digital counts from each band will be linked to the Earth-exiting radiance integrated over the spectral response of that band. In this technical memorandum, the effects of the instrument calibration and the source spectral shape on SeaWiFS measurements, including the in-band and out-of-band responses, and the center wavelengths are discussed.

Hooker, Stanford B.↗

Summary of Terra and Aqua MODIS On-orbit Calibration and Characterization Results

The Moderate Resolution Imaging Spectroradiometer (MODIS) onboard NASA's EOS Terra spacecraft has been in operation for more than seven years since its launch in December 1999 and the MODIS onboard Aqua spacecraft has been in operation for more than 4.5 years since its launch in May 2002. Compared to its heritage sensors, such as AVHRR, CZCS, SeaWiFS, HIRS, and Landsat TM, the MODIS instrument was developed with improved spectral and spatial resolutions, and temporal scale or global coverage frequency. The two MODIS instruments are nearly identical with each collecting data in 36 spectral bands: 20 reflective solar bands (RSB) with center wavelengths from 0.41 to 2.2jm and 16 thermal emissive bands (TEB) from 3.7 to 4.4 microns. MODIS makes the Earth view observations with a scan angle range of +/-55 degree relative to instrument nadir and at three nadir spatial resolutions: 0.25km for bands 1-2.05km for bands 3-7, and 1km for bands 8-36, thus enabling complete global coverage of the Earth in less than 2 days. Both Terra and Aqua MODIS observations have been routinely used to generate a broad range of science data products that are widely distributed and extensively applied for the studies of the Earth's land, oceans, and atmosphere and for the monitoring of climate and environmental changes. It is obvious that the MODIS science data product quality strongly relies on sensor on-orbit performance and its capability of continuously tracking sensor response changes over time. Because of this, each MODIS was built with a comprehensive set of on-board calibrators (OBC) that include a solar diffuser (SD) for the RSB calibration, a blackbody (BB) for the TEB calibration, and a spectro-radiometric calibration assembly (SRCA) for the spatial (RSB and TEB) and spectral (RSB only) characterization. Most importantly, extensive and dedicated sensor calibration and characterization efforts have been constantly made by the MODIS Characterization Support Team (MCST) at NASA/GSFC. In this presentation, we will provide an overview of MODIS sensor operations since 1aunh and the onorbit calibration and characterization methodologies with emphasis on the differences between Terra and Aqua MODIS characteristics. We will summarize both Terra and Aqua MODIS onorbit calibration and characterization results, including their RSB and TEB detector noise characterization, the sensor response changes, and the corrections to the optics degradation. In addition to radiometric calibration performance, we will illustrate both sensors' spectral and spatial characterization results in terms of their band-to-band registrations and spectral band center wavelength shifts.

Xiong, X.↗

Fiber Grating Coupled Light Source Capable of Tunable, Single Frequency Operation

Fiber Bragg grating coupled light sources can achieve tunable single-frequency (single axial and lateral spatial mode) operation by correcting for a quadratic phase variation in the lateral dimension using an aperture stop. The output of a quasi-monochromatic light source such as a Fabry Perot laser diode is astigmatic. As a consequence of the astigmatism, coupling geometrics that accommodate the transverse numerical aperture of the laser are defocused in the lateral dimension, even for apsherical optics. The mismatch produces the quadratic phase variation in the feedback along the lateral axis at the facet of the laser that excites lateral modes of higher order than the TM 00 . Because the instability entails excitation of higher order lateral submodes, single frequency operation also is accomplished by using fiber Bragg gratings whose bandwidth is narrower than the submode spacing. This technique is particularly pertinent to the use of lensed fiber gratings in lieu of discrete coupling optics. Stable device operation requires overall phase match between the fed-back signal and the laser output. The fiber Bragg grating acts as a phase-preserving mirror when the Bragg condition is met precisely. The phase-match condition is maintained throughout the fiber tuning range by matching the Fabry-Perot axial mode wavelength to the passband center wavelength of the Bragg grating.

Michael A Krainak↗

The Ocean Color Instrument Performance Summary

Overview: 1. Calibration equation, GSD, IFOV, FoR, B2B registration 2. Center wavelengths, spectral sampling, OOB 3. SNR, RVS, polarization, linearity 4. Straylight/crosstalk, temperature sensitivity 5. Striping, absolute gain, Gain trending, spectral on-orbit trending (measurements during tilt) 6. SWIR band hysteresis correction, SPCA measurements

PACE↗

Plant Chlorophyll Content Imager with Reference Detection Signals

A portable plant chlorophyll imaging system is described which collects light reflected from a target plant and separates the collected light into two different wavelength bands. These wavelength bands, or channels, are described as having center wavelengths of 700 nm and 840 nm. The light collected in these two channels is processed using synchronized video cameras. A controller provided in the system compares the level of light of video images reflected from a target plant with a reference level of light from a source illuminating the plant. The percent of reflection in the two separate wavelength bands from a target plant are compared to provide a ratio video image which indicates a relative level of plant chlorophyll content and physiological stress. Multiple display modes are described for viewing the video images.

Spiering, Bruce A.↗

Plant chlorophyll content meter

A plant chlorophyll content meter is described which collects light reflected from a target plant and separates the collected light into two different wavelength bands. These wavelength bands, or channels, are described as having center wavelengths of 700 nm and 840 nm. The light collected in these two channels are processed using photo detectors and amplifiers. An analog to digital converter is described which provides a digital representation of the level of light collected by the lens and falling within the two channels. A controller provided in the meter device compares the level of light reflected from a target plant with a level of light detected from a light source, such as light reflected by a target having 100% reflectance, or transmitted through a diffusion receptor. The percent of reflection in the two separate wavelength bands from a target plant are compared to provide a ratio which indicates a relative level of plant physiological stress. A method of compensating for electronic drift is described where a sample is taken when a collection lens is covered to prevent light from entering the device. This compensation method allows for a more accurate reading by reducing error contributions due to electronic drift from environmental conditions at the location where a hand-held unit is used.

Spiering, Bruce A.↗

Temperature Tunable Air-Gap Etalon Filter

We report on experimental measurements of a temperature tuned air-gap etalon filter. The filter exhibits temperature dependent wavelength tuning of 54 pm/C. It has a nominal center wavelength of 532 nm. The etalon filter has a 27 pm optical bandpass and 600 pm free spectral range (finesse approximately 22). The experimental results are in close agreement with etalon theory.

Krainak, Michael A.↗

Ozone and water vapor monitoring using a ground-based lidar system

Measurements of atmospheric ozone and water vapor profiles obtained using a differential absorption lidar (DIAL) technique at Haute Provence Observatory are reported. The DIAL technique is based on the comparison of differences in attenuation in backscattered signals at wavelengths centered on strong absorptions or absorption lines of the species in question, and wavelengths corresponding to weaker or no absorption. The system in use is based on three lasers - a Nd:YAG Q-switched laser frequency doubled to emit at 532 nm, and two tunable narrowline dye lasers used to convert this emission into the IR or UV spectral regions. Ozone concentration profiles have been recorded up to a height of 30 km, and reveal large day-to-day variations in number density which were correlated with a decrease in tropopause height. Measurements of water vapor concentrations show a variability of the mixing ratio at heights up to 2.5 km representative of dynamic processes, and a variability above 2.5 km that is within the measurement error. Day-to-day variations in tropospheric mixing ratio were also observed.

Megie, G.↗

Assessing the Temperature Dependence of Narrow-Band Raman Water Vapor Lidar Measurements: A Practical Approach

Narrow-band detection of the Raman water vapor spectrum using the lidar technique introduces a concern over the temperature dependence of the Raman spectrum. Various groups have addressed this issue either by trying to minimize the temperature dependence to the point where it can be ignored or by correcting for whatever degree of temperature dependence exists. The traditional technique for performing either of these entails accurately measuring both the laser output wavelength and the water vapor spectral passband with combined uncertainty of approximately 0.01 nm. However, uncertainty in interference filter center wavelengths and laser output wavelengths can be this large or larger. These combined uncertainties translate into uncertainties in the magnitude of the temperature dependence of the Raman lidar water vapor measurement of 3% or more. We present here an alternate approach for accurately determining the temperature dependence of the Raman lidar water vapor measurement. This alternate approach entails acquiring sequential atmospheric profiles using the lidar while scanning the channel passband across portions of the Raman water vapor Q-branch. This scanning is accomplished either by tilt-tuning an interference filter or by scanning the output of a spectrometer. Through this process a peak in the transmitted intensity can be discerned in a manner that defines the spectral location of the channel passband with respect to the laser output wavelength to much higher accuracy than that achieved with standard laboratory techniques. Given the peak of the water vapor signal intensity curve, determined using the techniques described here, and an approximate knowledge of atmospheric temperature, the temperature dependence of a given Raman lidar profile can be determined with accuracy of 0.5% or better. A Mathematica notebook that demonstrates the calculations used here is available from the lead author.

Raman lidar↗

In situ measurements of light extinction of stratospheric aerosols

The extinction coefficient of ambient aerosol particles was measured using a multiple transverse cell (White Cell) with an effective path length of 100 m. Measurements were performed at seven fixed wavelengths in the visible region using a white light source and an interference filter set with 2 nm bandwidth and center wavelengths of 405.5, 450, 500, 550, 600, 650, and 692.5 nm. The total air flow in the system was 16.7 1/min; the volume of the chamber is close to 10 liters. It takes about one minute to fill the chamber with particles homogeneously, but it needs up to five minutes to get the chamber particle-free. Before measuring the aerosol, the transmission of the particle-free air is determined; then the aerosol passes through the chamber for a period of ten minutes; after this the transmission of particle-free ambient air is measured again for eight minutes. All times are subject to change. At present the measurements are done with a frequency of 1 Hz, but an increase of up to 30 Hz is possible. The lower detection limit of the used White Cell is 3.4 by 10(exp -06) per m. This is sufficient for measuring the extinction coefficient during most tropospheric and some stratospheric conditions. It will be necessary to increase the sensitivity by a factor of ten when measurements under the clearest stratospheric conditions take place.

Metzig, Gunthard↗

Fabrication of Extremely Short Length Fiber Bragg Gratings for Sensor Applications

A new technique and a physical model for writing extremely short length Bragg gratings in optical fibers have been developed. The model describes the effects of diffraction on the spatial spectra and therefore, the wavelength spectra of the Bragg gratings. Using an interferometric technique and a variable aperture, short gratings of various lengths and center wavelengths were written in optical fibers. By selecting the related parameters, the Bragg gratings with typical length of several hundred microns and bandwidth of several nanometers can be obtained. These short gratings can be apodized with selected diffraction patterns and hence their broadband spectra have a well-defined bell shape. They are suitable for use as miniaturized distributed strain sensors, which have broad applications to aerospace research and industry as well.

Wu, Meng-Chou↗

Wide band fiber-optic communications

A number of optical communication lines are now in use at the Kennedy Space Center (KSC) for the transmission of voice, computer data and video signals. At the present time most of these channels utilize a single carrier wavelength centered near 1300 nm. As a result of previous work the bandwidth capacity of a number of these channels is being increased by transmitting another signal in the 1550 nm region on the same fiber. This is accomplished by means of wavelength division multiplexing (WDM). It is therefore important to understand the bandwidth properties of the installed fiber plant. This work developed new procedures for measuring the bandwidth of fibers in both the 1300nm and 1550nm region. In addition, a preliminary study of fiber links terminating in the Engineering Development Laboratory was completed.

Bates, Harry E.↗

Wavelength tunable liquid crystal imaging filters for remote sensing from geosynchronous platforms

Recent advances in liquid crystal technology have enabled us to construct tunable birefringent filters with bandwidths between approximately 0.1 nm and 50 nm. The center wavelength of these filters can be selected electronically, in a few tens of milliseconds, with no moving parts. These liquid crystal tunable filters (LCTF's), together with existing CCD detectors, make possible a new generation of lightweight, rugged, high-resolution imaging spectrophotometers. Such instruments would be particularly interesting for remote sensing applications from geosynchronous platforms. Important advantages exist in the aperture, absence of image shift, power consumption, size, weight, and absence of high drive frequencies, compared to current instruments used or considered for multispectral scene analysis. In the present work, we have reviewed spectral requirements of planned NASA geosynchronous remote sensing missions and identified several applications of the liquid crystal tunable filter technology. We have modeled the LCTF performance in the visible and near-infrared, and carried out a literature study on space-hardening of the filter components, to evaluate the suitability of LCTF's for geosynchronous missions. We have also compared the power consumption, weight, size, reliability, and optical performance of an imaging spectrophotometer using a LCTF monochromator, to other instruments that have been put forward for remote sensing from geosynchronous platforms. We put forward some conceptual designs for LCTF's that seem to offer important reliability, over the mechanical filter wheels presently baselined for the HEPI and ALM experiments. The extremely wide acceptance angle achievable with LCTF's could also avoid the present need for large-aperture interference filters in the ALM (and LIS) experiments. Thermal vacuum testing and radiation damage analysis is required to investigate the space hardening of these new filters for geosynchronous flight.

Foukal, Peter↗